POINT OF CONNECTION - NEW TO EXISTING
TURNING VANES
INCLINED RISE IN DUCT
IN-LINE 90 DEGREE RISE IN DUCT
RETURN OR EXHAUST AIR DUCT DOWN
DUCTWORK SIZE TRANSITION
RETURN OR EXHAUST AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT UP
SUPPLY OR OUTSIDE AIR DUCT DOWN
HVAC SYMBOLS
20/12
12"Ø
SUPPLY OR OUTSIDE AIR DUCT
90 DEGREE DUCTWORK ELBOW W/ TURNING VANES
ROUND OR RECTANGULAR
RECTANGULAR DUCTWORK BRANCH TAKE-OFF
HIGH EFFIECENY "BUCKLEY" TAP WITH DAMPER
RADIUS DUCTWORK ELBOW -
WITH 45 DEGREE BRANCH INLET
DIFFUSER/GRILLE LABEL:
B - NECK SIZE (INCHES)
A - TYPE/DESIGNATION
C - AIRFLOW (CFM)
RETURN, RELIEF OR EXHAUST AIR DUCT
PATTERN. NO PATTERN SHOWN EQUALS 4-WAY
FIRST NUMBER IS SIDE SHOWN
ROUND DUCTWORK. DIAMETER IN INCHES
RECTANGULAR DUCTWORK. SIZE IN INCHES,
SUPPLY AIR DIFFUSER - SHADING INDICATES
RETURN OR EXHAUST AIR GRILLE
OR AS NOTED
MANUAL VOLUME DAMPER
THERMOSTAT
SD
DRAWING NOTE REFERENCE
OVAL OR FLAT OVAL
ROUND
DUCT SMOKE DETECTOR
H HUMIDISTAT
S SENSOR
F
FIRE DAMPER
C CARBON DIOXIDE SENSOR
UC UNDERCUT DOOR 3/4" FOR AIRFLOW
XX/XXL INTERNALLY LINED DUCT
IN-LINE 90 DEGREE DROP IN DUCT
MOTORIZED DAMPER
MD
ABBREVIATIONS
EWB ENTERING WET BULB
TSTAT THERMOSTAT
UNLESS OTHERWISE NOTED
UNDERWRITERS LABORATORIES, INC.
MAXIMUM OVER CURRENT PROTECTION
MAKE-UP AIR
MECHANICAL
MANHOLE, METAL HALIDE
MANUFACTURER
MINIMUM
MOUNTED
MOTORIZED DAMPER
MOTOR CONTROL CENTER
MTD
MUA
MECH
MFR
MOCP
MIN
MH
MCC
MD
LEAVING WATER TEMPERATURE
LOCKED ROTOR AMPS
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPACITY
MAXIMUM
LIGHTING
LEAVING WET BULB
LEAVING DRY BULB
LOW PRESSURE
LEAVING AIR TEMPERATURE
INTERNALLY LINED
POUNDS
LWB
LWT
MAX
MCA
MBH
LTG
LBS, #
L
LAT
LRA
LDB
LP
H HEIGHT
KILOVOLT-AMPS
KILOWATT-HOUR
KILOWATTS
KVA
KWH
KW
HEAD, HUB DRAIN
HAND-OFF-AUTOMATIC
HORSEPOWER, HEAT PUMP
HUMIDISTAT
HEATER
HEATING
HEATING, VENTILATING & A/C
HYDRANT
DOMESTIC HOT WATER
HERTZ
HVAC
HYD
HW
HZ
HSTAT
HTR
HTG
HOA
HD
HP
ELECTRICAL CONTRACTOR
GALLON
GALVANIZED
GENERAL CONTRACTOR
GROUND FAULT INTERRUPTER
GALLONS PER MINUTE
GALLONS PER HOUR
GALLONS PER DAY
GAUGE
GREASE WASTE
GFI, GFIC
GPD
GPM
GPH
GW
GAL
GALV
GC
GA
DEGREES FAHRENHEIT
FOOT, FEET
ENTERING WATER TEMPERATURE
EXISTING
FIRE ALARM
FIRE DAMPER
FLEXIBLE
FEET PER MINUTE
FULL LOAD AMPS
FLOOR CLEANOUT
FIRE ALARM CONTROL PANEL
EXHAUST
°F
FT
FACP
FLEX
FPM
FCO
FD
FLA
FA
EX
EWT
EXH
EC
VAV VARIABLE AIR VOLUME
W/
W/O
WB
WC
W
VD
VTR
WITH
WET BULB
WATER COLUMN
WITHOUT
VENT THROUGH ROOF
VOLUME DAMPER
WATT, WIDTH
VAC
VA
UON
U/F
U/G
U/S
UL
TYP
VOLT-AMPERE, VALVE
VACUUM
VOLT, VENT
UNDERGROUND
UNDERSLAB
UNDERFLOOR
TYPICAL
SQUARE FEET, SQUARE FOOT
SMOKE DETECTOR, STORM DRAIN
REVOLUTIONS PER MINUTE
SHEET METAL & A/C CONT NAT'L ASSOC.
TOTAL STATIC PRESSURE
STORM WATER
POST INDICATOR VALVE
POUNDS PER SQUARE INCH
PRESSURE RELIEF VALVE
REFLECTED CEILING PLAN
REINFORCING, REINFORCED
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MFR'S ASSOC.
NATIONAL FIRE PROTECTION ASSOC.
NOISE CRITERIA
OUTSIDE STEM AND YOKE
OCCUPATIONAL SAFETY &HEALTH ADMIN.
OPPOSED BLADE DAMPER
OUTSIDE AIR (VENTILATION AIR)
TENANT EXHAUST (TOILET)
AWWA AMERICAN WATER WORKS ASSOC.
RL REFRIGERANT LIQUID
EXTERNAL STATIC PRESSURE
ELECTRICAL
ELEVATION
EQUIPMENT
ENCLOSURE
ENTERING DRY BULB
ENTERING AIR TEMPERATURE
DIRECT EXPANSION
DRAWING
EACH
DIRECT DIGITAL CONTROL
ESP
ENCL
ELEC
EQUIP
EDB
ELEV
EA
EAT
DX
DWG
DDC
DOMESTIC COLD WATER
DOWNSPOUT
DECIBEL
DIAMETER
DEGREES
DRY BULB
DEGREES CELSIUS
DISCONNECT
DIMENSION
DOWN
DS
DIA (OR Ø)
DN
DISC
DIM
CW
°C
dB
DEG
DB
SPEC SPECIFICATION
TE
THRU
TP
TSP
TDH
STD
SUSP
SURF
ST
SQ
TOTAL DYNAMIC HEAD
THROUGH
TOTAL PRESSURE
SUSPEND
STANDARD
SURFACE
SQUARE
SMACNA
SM
SP
SECT
SHT
SF
SD
RS
SA
RPM
RLA
SHEET METAL
STATIC PRESSURE
SECTION
SHEET
REFRIGERANT SUCTION
SUPPLY AIR
RUNNING LOAD AMPS
CONCRETE
CIRCUIT
CENTERLINE
CIRCULATING
COLUMN
CLEANOUT
CEILING
CUBIC FEET PER MINUTE
CUBIC FEET PER HOUR
CKT
L
CLG
COL
CO
C
CC
CIRC
CFM
CFH
ASSY ASSEMBLY
RECIRC
RD
REQ
REV
RHG
RH
REINF
RCP
RA
ROOF DRAIN
REFRIGERANT HOT GAS
REQUIRED
REVISION, REVISE
RELATIVE HUMIDITY
RECIRCULATE
RETURN AIR
PRV
PSI
PH, Ø
PIV
PLBG
PD
PLUMBING
PRESSURE DROP
PHASE
AMERICAN NAT'L STANDARDS INSTITUTE
AIR CONDITIONER, AIR CONDITIONING,
AMERICAN SOCIETY OF TESTING & MATLS
AMERICAN SOCIETY OF MECHANICAL ENGRS
REFRIGERATION & AC ENGINEERS
AIR CONDITIONING & REFRIG INSTITUTE
ABOVE FINISHED GRADE
AMP, AMPERE
AUXILIARY
AMERICAN SOCIETY OF HEATING,
ARCHITECT, ARCHITECTURAL
AMERICAN WELDING SOCIETY
AMERICAN WIRE GAUGE
AIR PRESSURE DROP
ADJUSTABLE
ABOVE FINISHED FLOOR
ABOVE FINISHED CEILING
ARI
ASME
ASTM
AUX
AWG
AWS
ASHRAE
AFG
ARCH
A
ANSI
APD
ADJ
AFF
AFC
AIR COOLED CONDENSING UNIT
AIR COOLED CHILLER
ABOVE
ACCU
ACC
ABV
A/C
OBD
OS&Y
OSHA
OD
OC
OA
NFPA
NTS
N.O.
NIC
OVERFLOW DRAINAGE, OUTSIDE DIAMETER
ON CENTER
NOT TO SCALE
NORMALLY OPEN
NOT IN CONTRACT
NEC
NEMA
N/A
NC
NOT APPLICABLE
ETR EXISTING TO REMAIN
REX REMOVE EXISTING
COP CLEANOUT PLUG
ORD OVERFLOW ROOF DRAIN
RWC RAIN WATER CONDUCTOR
ABOVE CEILING
AL ACOUSTIC LINING
BOTTOM OF PIPE
BUILDING
BRITISH THERMAL UNIT
BOTTOM OF STRUCTURE
BOTTOM OF DUCT
BOILER FEED WATER
BACKDRAFT DAMPER
BUILDING AUTOMATION SYSTEM
BLDG
BOP
BOS
BTU
BOD
BAS
BFW
BDD
BELOW FLOOR
BMS BUILDING MANAGEMENT SYSTEM
DOM DOMESTIC
FP FIRE PROTECTION
FW FILTERED WATER
GRD GROUND
MC MECHANICAL CONTRACTOR
O/H OVERHEAD
OPNG OPENING
REL RELOCATED
SAN SANITARY
D DEPTH
G GAS
CWR/CWS CONDENSING WATER RETURN/SUPPLY
CONNCONNECTION CONNECT,
CA COMBUSTION AIR
TWR/TWS TOWER WATER RETURN/SUPPLY
CHWR/CHWS CHILLED WATER RETURN/SUPPLY
N.C. NORMALLY CLOSED
PB PUSH BUTTON
HHWR/HHWS HEATING HOT WATER RETURN/SUPPLY
HWR DOMESTIC RECIRCULATED HOT WATER
B/F
CTE CONNECT TO EXISTING
FF FINISHED FLOOR
RR REMOVE AND RELOCATE
ID INSIDE DIAMETER
INVERT ELEVATION
INCH, INCHES
IN WC INCHES OF WATER COLUMN
IN
IE
V
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
(ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
A B
C
GENERAL SHEET NOTES
1. EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD
WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY.
CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR
INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS.
2. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT.
3. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT
INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION
PRESENTED AND FIELD CONDITIONS.
4. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS OR DEMOLITION THE CONTRACTOR SHALL
PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERING/MAINTENANCE
PERSONNEL OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS
TO ADJACENT SPACES.
5. PROTECT EQUIPMENT, FIXTURES, PIPING, DUCTWORK, ETC. INDICATED TO REMAIN AGAINST DAMAGE
AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY THE ARCHITECT, ITEMS MAY BE
REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND THEN
CLEANED AND REINSTALLED IN THEIR ORIGINAL LOCATIONS.
6. WHERE PIPE, DUCTWORK, INSULATION, FIXTURES OR EQUIPMENT TO REMAIN IS DAMAGED OR
DISTURBED, REMOVE THE DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF EQUAL CAPACITY AND
QUALITY. WHERE IDENTICAL MATERIALS ARE UNAVAILABLE OR CANNOT BE USED, USE MATERIALS
WHOSE INSTALLED PERFORMANCE EQUALS OR SURPASSES THAT OF THE EXISTING MATERIALS.
7. MAINTAIN AND RESTORE, IF INTERRUPTED BY DEMOLITION OR IN THE PATH OF NEW CONSTRUCTION,
ALL UTILITIES PASSING THROUGH AND SERVING OUTSIDE OF DEMOLITION AREA.
8. MECHANICAL SYSTEMS INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS
DESIGNATED AS EITHER FIRE RATED OR "SMOKE TIGHT". SEAL AROUND ALL PENETRATIONS THROUGH
RATED OR SMOKE TIGHT ASSEMBLIES. COORDINATE W/ARCHITECTURAL PLANS AND GENERAL
CONTRACTOR.
9. SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. CONSTRUCTION MATERIALS ABOVE
CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE
DEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED PER NFPA 70.
10. LIMITED ABOVE CEILING CLEARANCES EXIST. COORDINATE LOCATION AND ELEVATION OF MECHANICAL
WORK WITH ALL DUCTWORK, SPRINKLERS, LIGHT FIXTURES, AND OTHER CEILING BUILT-IN FIXTURES.
CONTACT ENGINEER OR ARCHITECT IMMEDIATELY SHOULD ANY CONFLICT ARISE.
11. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE PERFORMED BY A LANDLORD APPROVED
ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS AND
ROOFTOP EQUIPMENT LOCATIONS WITH LANDLORD AND GENERAL CONTRACTOR.
12. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK.
CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL
STEEL WHICH EXISTS ABOVE THE SPACE.
13. COORDINATE FINAL ROOFTOP UNIT LOCATIONS WITH LANDLORDS STRUCTURAL ENGINEER. ROOFTOP
UNITS AND MAKE-UP AIR UNIT TO BE LOCATED WITHIN STRUCTURAL BAY. PROVIDE 10' CLEARANCE FROM
UNIT OUTSIDE AIR INTAKE TO ANY EXHAUST/VENTS ON ROOF.
14. GENERAL CONTRACTOR TO LABEL ALL ROOFTOP EQUIPMENT WITH TENANT NAME, SPACE NUMBER AND
EQUIPMENT IDENTIFICATION (RTU-1, ETC.), PER MALL SPECIFICATIONS AND STANDARDS.
15. REFER TO MALL CRITERIA MANUAL FOR ADDITIONAL STANDARDS AND REQUIREMENTS.
16. COORDINATE ALL THERMOSTAT AND SENSOR LOCATIONS WITH FURNITURE LAYOUT AND
ARCHITECTURAL PLANS. DEVICES ARE TO BE INSTALLED AND WIRED BY THE HVAC CONTRACTOR,
MOUNT PER ADA REQUIREMENTS.
17. ALL EXPOSED DUCTWORK TO BE PAINTED. REFER TO ARCHITECTURAL PLANS.
18. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION WITH A MAXIMUM INCLUDE
ANGLE OF DIVERGENCE OF 15 DEGREE.
19. DUCT SIZES INDICATED REPRESENT EXTERNAL SHEET METAL DIMENSIONS AND INCLUDE ALLOWANCE
FOR INTERNAL INSULATION.
20. ALL SUPPLY AND MAKE-UP AIR DUCTWORK NOT EXPOSED SHALL BE EXTERNALLY INSULATED.
21. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED
UNLESS NOTED OTHERWISE.
22. PROVIDE A STRAIGHT INLET LENGTH TO THE VAV BOX OF A MINIMUM (4) DUCT DIAMETERS. REFER TO
DETAIL FOR ADDITIONAL INFORMATION.
23. PROVIDE ACCESS HATCHES (24"x24") FOR ALL MECHANICAL EQUIPMENT LOCATED ABOVE A HARD
CEILING. COORDINATE W/ ARCHITECTURAL CEILING PLANS.
24. PITCH POCKETS ARE NOT PERMITTED ON THE ROOF FOR CONDENSATE DRAINS, POWER OR CONTROL
WIRING. ALL CONNECTIONS ARE TO BE MADE INSIDE THE EQUIPMENT CURB OR THROUGH
PRE-MANUFACTURED PIPING CURB.
25. COORDINATE EXACT MOUNTING REQUIREMENTS AND LOCATION OF HOOD WITH HOOD SHOP DRAWINGS
AND OWNER REQUIREMENTS.
26. GREASE EXHAUST DUCT ACCESS PANEL CLEANOUT OPENINGS SHALL BE EQUIPPED WITH TIGHT FITTING
DOORS (EQUAL TO THE THICKNESS OF THE DUCT) AND SHALL HOLD TIGHTLY CLOSED.
27. ALL DUCTWORK, DIFFUSERS AND GRILLES IN POOL AREA SHALL BE ALUMINUM CONSTRUCTION.
28. CONTRACTOR MUST REPLACE ALL AIR FILTERS IN ROOFTOP UNITS WITH NEW CLEAN FILTERS BEFORE
AIR BALANCING AND PRIOR TO FINAL TURNOVER TO TENANT.
END VIEW
18"MIN
18" MIN
SIDE VIEW
DETAIL NOTES
1. PROVIDE SEISMIC/HURRICANE RESTRAINTS WHEN REQUIRED BY CODE. SEISMIC/HURRICANE
RESTRAINTS SHALL BE FURNISHED BY ROOFTOP UNIT MANUFACTURER AND INSTALLED BY
CONTRACTOR. RESTRAINTS SHALL BE INSTALLED AS CLOSE AS POSSIBLE TO EACH CORNER OF ROOF
CURB.
SA
ROOF TOP UNIT
SEAL BETWEEN ALL DUCTS AND ROOF
DECK WITH ACOUSTICAL SEALANT
FLEX CONNECTION
VERTICAL SUPPLY AIR DUCT
SHALL BE FULL SIZE OF UNIT
OPENING, TRANSITION TO DUCT
SIZE INDICATED ON PLAN
DUCT TRANSITIONS SHALL BE
MADE WITH A MAXIMUM ANGLE
OF 15° AND A MINIMUM OF 18" IN
LENGTH
DUCT TRANSITIONS SHALL BE
MADE WITH A MAXIMUM ANGLE
OF 15° AND MINIMUM OF 18" IN
LENGTH
PROVIDE FLEX CONNECTION
BELOW ROOF DECK FOR
SUPPLY AND RETURN AIR DUCT
DROPS
ROOFTOP UNIT
SEAL BETWEEN ALL DUCTS
AND ROOF DECK WITH
ACOUSTICAL SEALANT
DUCT MOUNTED SMOKE DETECTOR
SEISMIC/HURRICANE RESTRAINT
(TYPICAL AT 4 LOCATIONS, REFER
TO DETAIL NOTE 1)
1" INTERNALLY LINED
RETURN AIR DUCTWORK
SCALE: NONE
1
M001
RTU SECTION DETAIL
UNION
HAND TIGHT PLUG
COPPER CONDENSATE DRAIN LINES PAST
CURB TO PREVENT CURB FROM RUST DAMAGE,
DO NOT USE PVC FOR CONDENSATE DRAIN
LINES, KEEP VERTICAL CONDENSATE LINE A
MINIMUM OF 3" FROM CURB
MINIMUM 1/2"
"H" = 1 1/4"
EXTEND TO ROOF WHERE
EXISTING IS PIPED TO ROOF
DRAIN OR REQ'D BY LOCAL
AUTHORITIES, SECTION TO
DRAIN ONLY MAY BE PVC
SCALE: NONE
2
M001
RTU CONDENSATE DETAIL
ISSUE DATE
200311
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
C
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
NOT FOR CONSTRUCTION
PRELIMINARY
12.31.2020
JDF DEVELOPMENT
THE AVENUE
AT BENNETT FARM
OUTLOT BUILDING
CARMEL, INDIANA
5719 LAWTON LOOP E. DR.
#212 INDIANAPOLIS, IN 46216
O :: 317 . 288 . 0681
F :: 317 . 288 . 0753
T E S
tesengineering.com E N G I N E E R I N G
F 440 871 7954
P 440 871 2410
25760 First Street
Cleveland, OH 44145
M001
MECHANICAL
LEGEND, NOTES, DETAILS
05/10/21