HomeMy WebLinkAboutM001.5SCALE: 1/4" = 1'-0"
1
P101
PLUMBING PLAN
1
A
2 3 4
B
DRAWING NOTES
1
CONNECT TO EXISTING GAS SERVICE. PROVIDE AND INSTALL GAS METER. COORDINATE WITH
UTILITY.
2 CONNECT TO EXISTING 6" SANITARY.
3 CONNECT TO EXISTING 1-12" DOMESTIC WATER.
4 CONNECT TO EXISTING 6" GREASE WASTE AND 1000 GREASE TRAP.
5 CONNECT TO EXISTING 6" FIRE PROTECTION.
6 FIRE PROTECTION RISER
GENERAL SHEET NOTES
1. EXISTING PLUMBING INFORMATION IS BASED ON EXISTING BUILDING DRAWINGS. THE CONTRACTOR
SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. CONTRACTOR SHALL NOTIFY OWNER,
ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM
THAT IS DESCRIBED IN THE DOCUMENTS.
2. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT
INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION
PRESENTED AND FIELD CONDITIONS.
3. PLUMBING INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED
AS EITHER FIRE RATED OR "SMOKE TIGHT". SEAL AROUND ALL PENETRATIONS THROUGH RATED OR
SMOKE TIGHT ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND GENERAL CONTRACTOR.
4. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK.
CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL
STEEL WHICH EXISTS ABOVE THE SPACE.
5. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN WEATHERPROOF PRIOR TO CONCEALMENT.
EXISTING 2" DOMESTIC WATER U/G
2" RPZ ETR
3
6
5
1-1/2"
GW
6" U/G
CO
SAN
CO
6" U/G
4 2
1
ISSUE DATE
200311
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE.
C
PROJECT INFORMATION
CERTIFICATION
ISSUE DATES
NOT FOR CONSTRUCTION
PRELIMINARY
12.31.2020
JDF DEVELOPMENT
THE AVENUE
AT BENNETT FARM
OUTLOT BUILDING
CARMEL, INDIANA
5719 LAWTON LOOP E. DR.
#212 INDIANAPOLIS, IN 46216
O :: 317 . 288 . 0681
F :: 317 . 288 . 0753
T E S
tesengineering.com E N G I N E E R I N G
F 440 871 7954
P 440 871 2410
25760 First Street
Cleveland, OH 44145
P101
PLUMBING
PLAN
Move this and
show toilet room
rough ins...
Note 6 - riser?
05/10/21