HomeMy WebLinkAboutCarrigan Mount locationsAERIAL VIEW
ADDRESS:9646 CEDAR POINT DRIVE,
CARMEL, IN 46032
39.927377, -86.179933
APN: 291-310-301-057-000-018
CUSTOMER INFORMATION
NAME:JOHN CARRIGAN
DATE:4/27/21
SCALE:AS NOTED REV:A
AHJ:IL-CITY OF CARMEL
UTILITY:IPL
PRN NUMBER:GRN-24699
DESIGNER /CHECKED
BY: BC/BH
PAPER SIZE:17X11
MOUNTING DETAIL
M-1
ALUMINIUM RAILS
SCALE:1/16" = 1'-0"
SITE INFORMATION - WIND SPEED: 115 MPH AND SNOW LOAD: 20 PSF
SR.
NO
AZIMUTH PITCH
NO. OF
MODULES
ARRAY AREA
(SQ. FT.)
ROOF TYPE ATTACHMENT
ROOF
EXPOSURE
FRAME TYPE
FRAME
SIZE
FRAME
SPACING
MAX RAIL
SPAN
OVER
HANG
MP-01 180° 42° 20 386.3
COMPOSITION
SHINGLE
QUICK BOLT
L-FOOT
ATTIC RAFTERS 2 X 4 2'-0" 4'-0" 1'-6"
ARRAY MP-01
2 X 4 RAFTERS @
2'-0"SPACING
NOTE:PENETRATIONS ARE STAGGERED
INSTALLATION NOTES
1.STRUCTURAL ROOF MEMBER LOCATIONS ARE
ESTIMATED AND SHOULD BE LOCATED AND VERIFIED
BY THE CONTRACTOR WHEN LAG BOLT PENETRATION
OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS
REQUIRED.
2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL
BE COMPLETED AND SEALED WITH APPROVED SEALANT
PER CODE BY A LICENSED CONTRACTOR.
3.LAGS MUST HAVE A MINIMUM 2.5" THREAD
EMBEDMENT INTO THE STRUCTURAL MEMBER.
4.ALL PV RACKING ATTACHMENTS SHALL BE
STAGGERED BY ROW BETWEEN THE ROOF FRAMING
MEMBERS AS NECESSARY.
5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE
THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL
GREATER THAN 40'.
6.ALL CONDUCTORS AND CONDUITS ON THE ROOF
SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE
(INCLUDING CABLES UNDERNEATH MODULES AND
RACKING).
7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY
PLUMBING, MECHANICAL OR BUILDING ROOF VENTS.
ROOF ACCESS PATHWAYS AND SETBACKS:
1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUP
R-3BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FOR
GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS
1204.2.1.1 THROUGH 1204.2.1.3.
EXCEPTIONS:
1.THESE REQUIREMENTS SHALL NOT APPLY TO
STRUCTURES DESIGNED AND CONSTRUCTED IN
ACCORDANCE WITH THE INTERNATIONAL RESIDENTIAL
CODE.
2.THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS
WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS
HORIZONTAL OR LESS.
1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THAN
TWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATE
ROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE,
SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER
THAN ONE PATHWAY SHALL BE PROVIDED ON THE
STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH
ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT
FEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAY
FROM LOWEST ROOF EDGE TO RIDGE SHALL BE
PROVIDED ON THE SAME ROOF PLANE AS THE
PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE
OR STRADDLING THE SAME AND ADJACENT ROOF
PLANES
1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAIC
ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN
VIEW TOTAL ROOF AREA,
A SETBACK OF NOT LESS THAN 18 INCHES (457
MM)WIDE IS REQUIRED ON BOTH SIDES OF A
HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS
OCCUPYING MORE THAN 33 PERCENT OF THE PLAN
VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS
THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON
BOTH SIDES OF A HORIZONTAL RIDGE.
1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS.
PANELS AND MODULES INSTALLED ON GROUP R-3
BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF
A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND
RESCUE OPENING. A PATHWAY OF NOT LESS THAN 36
INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE
EMERGENCY ESCAPE AND RESCUE OPENING
1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE.
WHERE AN AUTOMATIC SPRINKLER SYSTEM IS
INSTALLED WITHIN THE DWELLING IN ACCORDANCE
WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE
SHALL CONFORM TO ONE OF THE FOLLOWING:
1.FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT
OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A
SETBACK OF NOT LESS THAN 18 INCHES (457 MM)
WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL
RIDGE.
2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN
66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A
SETBACK OF NOT LESS THAN 36 INCHES (914 MM)
WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL
RIDGE
4'