HomeMy WebLinkAboutCarrigan Site plan layoutMSP
INV AC UM
VICINITY MAP
ADDRESS:9646 CEDAR POINT DRIVE,
CARMEL, IN 46032
39.927377, -86.179933
APN: 291-310-301-057-000-018
CUSTOMER INFORMATION
NAME:JOHN CARRIGAN
DATE:4/27/21
SCALE:AS NOTED REV:A
AHJ:IL-CITY OF CARMEL
UTILITY:IPL
PRN NUMBER:GRN-24699
DESIGNER /CHECKED
BY: BC/BH
PAPER SIZE:17X11
SHEET CATALOG
INDEX NO. DESCRIPTION
T-1 COVER PAGE
M-1 MOUNTING DETAIL
M-2 STRUCTURAL DETAIL
E-1 SINGLE LINE DIAGRAM
PL-1 WARNING PLACARDS
SS SPEC SHEET(S)
SITE PLAN LAYOUT
(E) MAIN SERVICE
PANEL(INTERIOR)
(E) UTILITY METER
(EXTERIOR)
(N) PV INVERTER
(EXTERIOR)
CONDUIT RUN
PROPERTY LINE
PHOTOVOLTAIC
ARRAY ON THE ROOF
1'-6" FIRE SETBACK
·ELECTRIC CODE:NEC 2017
·FIRE CODE:IFC 2018
·BUILDING CODE:IBC 2018
·RESIDENTIAL CODE:IRC 2018
APPLICABLE CODES
JOHN CARRIGAN - 6.800kW DC, 6.000kW AC
COVER PAGE
T-1
SCALE:1"=30'-0"
1.MODULES ARE LISTED UNDER UL 1703 AND
CONFORM TO THE STANDARDS.
2.INVERTERS ARE LISTED UNDER UL 1741 AND
CONFORM TO THE STANDARDS.
3.DRAWINGS ARE DIAGRAMMATIC, INDICATING
GENERAL ARRANGEMENT OF THE PV SYSTEM AND
THE ACTUAL SITE CONDITION MIGHT VARY.
4.WORKING CLEARANCES AROUND THE NEW PV
ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN
ACCORDANCE WITH NEC 110.26.
5.ALL GROUND WIRING CONNECTED TO THE MAIN
SERVICE GROUNDING IN MAIN SERVICE PANEL/
SERVICE EQUIPMENT.
6.ALL CONDUCTORS SHALL BE 600V, 75°C
STANDARD COPPER UNLESS OTHERWISE NOTED.
7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE
FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
8.THE SYSTEM WILL NOT BE INTERCONNECTED BY
THE CONTRACTOR UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND/OR THE UTILITY.
9.ROOF ACCESS POINT SHALL BE LOCATED IN
AREAS THAT DO NOT REQUIRE THE PLACEMENT
OF GROUND LADDERS OVER OPENINGS SUCH AS
WINDOWS OR DOORS, AND LOCATED AT STRONG
POINTS OF BUILDING CONSTRUCTION WHERE THE
ACCESS POINT DOES NOT CONFLICT WITH
OVERHEAD OBSTRUCTIONS SUCH AS TREES,
WIRES OR SIGNS.
10.PV ARRAY COMBINER/JUNCTION BOX
PROVIDES TRANSITION FROM ARRAY WIRING TO
CONDUIT WIRING
GENERAL NOTES
TOTAL AREA OF ROOF (SQ.FT) 2612
TOTAL ARRAY AREA (SQ.FT) 386.2639
TOTAL AREA OF ARRAY COVERED
IN THE ROOF (%)
14.79
(N) AC DISCONNECT
(EXTERIOR)
3'FIRE SETBACK
CEDAR POINT DR
SCOPE OF WORK
GENERAL SYSTEM INFORMATION:
SYSTEM SIZE:
6800W DC, 6000W AC
MODULES:
(20)HANWHA Q.PEAK DUO BLK-G6 340
INVERTER:
(1)SOLAREDGE TECHNOLOGIES SE6000H-US
ENERGY HUB INVERTER (240V)
OPTIMIZER:
(20)SOLAREDGE P340 POWER OPTIMIZER
DRIVE WAY
186'-4"
128'
187'-3"
59'
40'
32'-7"
30'-10"
FENCE
FENCE
05/10/21