Loading...
HomeMy WebLinkAboutCarrigan Site plan layoutMSP INV AC UM VICINITY MAP ADDRESS:9646 CEDAR POINT DRIVE, CARMEL, IN 46032 39.927377, -86.179933 APN: 291-310-301-057-000-018 CUSTOMER INFORMATION NAME:JOHN CARRIGAN DATE:4/27/21 SCALE:AS NOTED REV:A AHJ:IL-CITY OF CARMEL UTILITY:IPL PRN NUMBER:GRN-24699 DESIGNER /CHECKED BY: BC/BH PAPER SIZE:17X11 SHEET CATALOG INDEX NO. DESCRIPTION T-1 COVER PAGE M-1 MOUNTING DETAIL M-2 STRUCTURAL DETAIL E-1 SINGLE LINE DIAGRAM PL-1 WARNING PLACARDS SS SPEC SHEET(S) SITE PLAN LAYOUT (E) MAIN SERVICE PANEL(INTERIOR) (E) UTILITY METER (EXTERIOR) (N) PV INVERTER (EXTERIOR) CONDUIT RUN PROPERTY LINE PHOTOVOLTAIC ARRAY ON THE ROOF 1'-6" FIRE SETBACK ·ELECTRIC CODE:NEC 2017 ·FIRE CODE:IFC 2018 ·BUILDING CODE:IBC 2018 ·RESIDENTIAL CODE:IRC 2018 APPLICABLE CODES JOHN CARRIGAN - 6.800kW DC, 6.000kW AC COVER PAGE T-1 SCALE:1"=30'-0" 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING GENERAL NOTES TOTAL AREA OF ROOF (SQ.FT) 2612 TOTAL ARRAY AREA (SQ.FT) 386.2639 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%) 14.79 (N) AC DISCONNECT (EXTERIOR) 3'FIRE SETBACK CEDAR POINT DR SCOPE OF WORK GENERAL SYSTEM INFORMATION: SYSTEM SIZE: 6800W DC, 6000W AC MODULES: (20)HANWHA Q.PEAK DUO BLK-G6 340 INVERTER: (1)SOLAREDGE TECHNOLOGIES SE6000H-US ENERGY HUB INVERTER (240V) OPTIMIZER: (20)SOLAREDGE P340 POWER OPTIMIZER DRIVE WAY 186'-4" 128' 187'-3" 59' 40' 32'-7" 30'-10" FENCE FENCE 05/10/21