7 Foundation Details
REVISION TABLENUMBER DATE REVISED BYDESCRIPTION SHEET: SCALE:DRAWINGS PROVIDED BY: DATE: 05/05/2021Hoosier Building4326 South Scatterfield RoadAnderson, IN 46013Property Address :14541 Brackney LaneCarmel, IN 46032Property Owner:Mark MyersCHIEF ARCHITECT, INC. MAKES NO WARRANTY THAT THESE DRAWINGS COMPLY WITH ANY BUILDING CODES AND PROVIDED TO YOU "AS IS". PLEASE REFER TO YOUR END USER SOFTWARE LICENSE AGREEMENTFOR MORE INFORMATION ABOUT THE TERMS AND CONDITIONSPURSUANT TO THESE DRAWINGS. © Chief Architect 2006 8" thick Stem Wall Poured Conrete 2500 PSI or better 1/2 Inch Rebar POURED CONCRETE FOOTING Footing to be 8" x 20" 2500 PSI or better VERTICAL REINFORCING STEEL AS REQUIRED 1/2- Inch BARS on 36" Centers T-Style Foundation Footing to be 20" x 8" thick - Double 1/2 Rebar reinforced Stem wall to be 8" thick with reinforced rebar every 36" on center. 5 Inch Slab - 2500 PSI or better Includes Steel mesh reinforcement 1/2 Inch Rebar Compacted Engineered Fill PORCH FOUNDATION DETAILS Foundation Depth to be 32" or deeper 05/10/21