HomeMy WebLinkAboutE03.1\A1;10'-0" {\C4;END OF PIPE TO FINISHED FLOOR} {\C4;PIPE LENGTH VARIES} {\C4;PROVIDE DUPLEX RECEPTACLE SURFACE MOUNTED 6" ABOVE THE END OF PIPE. POWER SHALL BE RUN TO OUTLET AFTER VENDOR #5 INSTALLED PROJECTOR MOUNTING BRACKET.} {\C4;1-1/2" I.D. STANDARD THREAD SCH 40 PIPE PAINTED BLACK, SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR. RUN POWER (1/2" MC CABLE), DATA AND VIDEO CABLE DOWN INSIDE PIPE. } AUDIO/VISUAL & SECURITY POWER CIRCUITS IG CIRCUITS 1-1/2" C. TO IG PANEL 1-1/2" C. TO NORMAL POWER PANEL RUN BELOW SLAB TO WALL AND UP TO JOIST SPACE (SEE FLOOR PLAN) DATA {\C4;PROJECTOR MOUNTING HARDWARE PROVIDED AND INSTALLED BY VENDOR #5. PROJECTOR PROVIDED AND INSTALLED BY FORESIGHT.} {\C4;PROJECTOR FLANGE SUPPLIED BY VENDOR #5, INSTALLED BY ELECTRICAL CONTRACTOR. ATTACH TO BAR JOIST USING (2) UNISTRUT P1000 CHANNEL SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR } 4 SCALE: N.T.S. SCALE: N.T.S. 1-1/2" C TURN CONDUIT INTO GOLF STOCK ROOM FOR IDF CABLES 1-1/2" C TURN CONDUIT INTO GOLF STOCK ROOM FOR IDF CABLES CONDUIT BELOW CONCRETE FLOOR SLAB. TYPICAL OF ALL FOUR LINEAR RUNS. 1. CONDUITS MAY CHANGE IN ANY ORDER BUT MUST CONTAIN ONLY THE WIRING SYSTEM SHOWN. 2. IDENTIFY IG & NORMAL WIRING WITH DIFFERENT COLOR WIRES. 3. CONDUIT STUB-UPS SHALL BE UNDER COUNTER SPACE AND NOT IN STANDING SPACE (COORDINATE WITH GENERAL CONTRACTOR). 4. PROVIDE (2) TWO PULLSTRINGS IN EACH OF THE CONDUITS FOR LOW VOLTAGE CABLING. LABEL EACH END OF THE PULLSTRINGS AS DATA BY VENDOR 13. LABEL EACH END OF THE PULL STRINGS IN THE AUDIO/VISUAL & SECURITY CONDUIT AS VENDOR 2 AND THE OTHER AS A/V VENDOR. 5. EXTEND CONDUITS TO ROOF STRUCTURE FOR CONDUITS CONTAINING THE LOW VOLTAGE CABLING. PROVIDE LONG RADIUS 90'S AND BUSH ENDS FOR CABLE PROTECTION. VERIFY EXACT INSTALLATION DETAILS WITH DSG ELEVATION DETAIL SCALE: N.T.S. 10'-3" (123") HOLD 9'-6" (114") HOLD {\C4;END OF PIPE TO FINISHED FLOOR} {\C4;PIPE LENGTH VARIES} {\C4;ELECTRICAL CONTRACTOR TO PROVIDE DUPLEX RECEPTACLE SURFACE MOUNTED TO BACK OF LCD TV BRACKET PROVIDED AND INSTALLED BY VENDOR #5.} {\C4;CEILING FLANGE SUPPLIED BY VENDOR #5, INSTALLED BY ELECTRICAL CONTRACTOR. ATTACH TO BAR JOIST USING (2) UNISTRUT P1000 CHANNEL SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR } {\C4;1-1/2" I.D. STANDARD THREAD SCH 40 PIPE PAINTED BLACK, SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR. RUN POWER (1/2" MC CABLE), DATA AND VIDEO CABLE DOWN INSIDE PIPE. } 1 TYPE UL / UL-NL LUMINAIRE INSTALLATION DETAIL SCALE: N.T.S. SINGLE CIRCUIT WIRING SYSTEM IN JOIST SPACE. PURCHASE FROM VENDOR #18 W ASHER & BOLT W ITH LOOP BY E.C . TYPE "UL" FIXTURE (SEE SCHEDULE) "ACS" WIRING SYSTEM CORD REFLECTOR AND BALLAST SAFETY AIRCRAFT CABLE VENDOR #18 TO PROVIDE HOOK AND CHAIN TO MOUNT FIXTURE AS HIGH AS POSSIBLE E.C. TO PROVIDE BRIDAL RINGS OR TIE STRAPS TO ATTACH THE MODULAR WIRING TO STRUCTURE. RUN WIRING SYSTEM ALONG JOIST SPAN OR AT RIGHT ANGLES TO JOIST UNISTRUT CHANNEL BY E.C. TOP CHORD OF BAR JOIST 17'-0" A.F.F. (TYPICAL IN SALES AREA U.N.O.) BOTTOM CHORD OF BAR JOIST 1. BOLT HOOK TO UNISTRUT. DOUBLE NUT ALL THREADED CONNECTIONS. PROVIDE HOOK AND LOOP TO SUPPORT FIXTURE BY MEANS OF STEEL CHAIN. SUPPORT FIXTURE FROM UNISTRUT, COORDINATE METHOD OF FASTENING UNISTRUT TO TOP CHORD OF JOIST WITH STRUCTURAL ENGINEER PRIOR TO INSTALLATION. DO NOT DRILL OR WELD TO JOIST. ASSEMBLY SHALL SUPPORT FOUR TIMES THE FIXTURE WEIGHT. 2. WHERE FIXTURES OCCUR DIRECTLY BELOW BAR JOIST I.E. MAIN CENTER AISLE, PROVIDE JOIST CLAMP WITH HOOK AND CHAIN FOR FIXTURE MOUNTING TO JOIST. 3. ALL UNISTRUT SHALL BE PAINTED TO MATCH CEILING. REFER TO ARCHITECTURAL DRAWINGS. 4. E.C. SHALL INSTALL ALL LIGHTING IN ACCORDANCE WITH N.E.C. 5. FIXTURE TYPE UL/UL-NL SHALL COME COMPLETE WITH "ACS" MODULAR WIRING AND HOOK. E.C. SHALL WRAP AND TIE EXCESS CORD. 6. LIGHT FIXTURE TYPES "UL & UL/NL" ARE TO BE WIRED WITH "ACS" MODULAR WIRING SINGLE CIRCUIT WIRING SYSTEM. PURCHASE ALL RELATED COMPONENTS FROM VENDOR #18. CONTACT VENDOR FOR COMPLETE PACKAGE LIST PRIOR TO %%UNOTES: SCALE: N.T.S. TRACK MOUNT TO STRUCTURE ABOVE WITH UNISTRUT BY EC CADDY SPEED LINK 1.5mm GALV. CABLE BY VENDOR #18 90 0 0 40 WALL WASH BALLAST MODULE TRACK HEAD 90 0 0 40 2F-15Z-832 CABLE GRIPPER W/ 8-32 INTERNAL THREAD, BY VENDOR #18 CADDY SPEED LINK ERICO 1. LOCATE TRACK LIGHTING AS SHOWN ON ARCHITECT'S REFLECTED CEILING PLAN. 2. MOUNT ALL TRACK LIGHTING AT 16'-0" AFF. AT EXPOSED AREAS, UNLESS OTHERWISE NOTED. 3. ELECTRICAL CONTRACTOR TO VERIFY COUNTS OF LED FIXTURES. LOCATE FIXTURES AS SHOWN ON ARCHITECTURAL DRAWINGS. ELECTRICAL CONTRACTOR TO PROVIDE 5 ADDITIONAL FIXTURES FOR USE BY DICK'S SPORTING GOODS. 4. INITIAL AIMING FOR FIXTURES MOUNTED AT 15'-6" - 16'-0" AFF., AIM LIGHT FIXTURES 40 DEGREES AS DIAGRAMMED, EMPHASIZING THE ADJACENT MERCHANDISE WALL DISPLAY AND BRANDING GRAPHICS. PERFORM FINAL AIMING ADJUSTMENTS AS DIRECTED BY DICK'S SPORTING GOODS AUTHORIZED REPRESENTATIVE. 5. TRACK SUPPORTING CABLES ARE TO BE 4'-0" ON CENTER WITH A SUPPORT LOCATED AT EACH TRACK END (OR PER LOCAL CODE). FACTORY PREDRILLED HOLES ARE NOT DESIGNATED SUPPORT HANGING POINTS AND WILL NOT %%UTRACK NOTES: GENERIC LIGHTING TRACK BY VENDOR #18 9'-3" (111") HOLD 8'-6" (102") HOLD {\C4;END OF PIPE TO FINISHED FLOOR} {\C4;PIPE LENGTH VARIES} {\C4;1-1/2" I.D. STANDARD THREAD SCH 40 PIPE PAINTED BLACK, SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR. RUN POWER (1/2" MC CABLE), DATA AND VIDEO CABLE DOWN INSIDE PIPE. } {\C4;ELECTRICAL CONTRACTOR TO PROVIDE DUPLEX RECEPTACLE SURFACE MOUNTED TO BACK OF LCD TV BRACKET PROVIDED AND INSTALLED BY VENDOR #5.} 8 SCALE: N.T.S. {\C4;CEILING FLANGE SUPPLIED BY VENDOR #5, INSTALLED BY ELECTRICAL CONTRACTOR. ATTACH TO BAR JOIST USING (2) UNISTRUT P1000 CHANNEL SUPPLIED & INSTALLED BY ELECTRICAL CONTRACTOR } Mar 26, 2021 - 17:37:16 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_E3.1.dwg Updated By: rvan E3.1 ELECTRICAL DETAILS PJN CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 25001 Emery Road, Suite #200 Warrensville Heights, Ohio 44128 Phone: 216-292-4696 Fax: 216-292-5874 Email: mail@mchenryassociates.com Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 05/11/21