Loading...
HomeMy WebLinkAboutE05.0XRW XRW XRW XRW XRW XRW X X X X X X X X X X N N N N N VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION COUNT ROOM HEAD CASHIER STR MGR/DEPT MGR DISTRICT MGR OUTLETS POS TRANSMITTER - 1ST FLOOR POS TRANSMITTER - 1ST FLOOR POS TRANSMITTER - 2ND FLOOR POS TRANSMITTER - 2ND FLOOR TEMPORARY CASH WRAPS TEMPORARY CASH WRAPS ALL-IN-ONE PC HITTRAX IG POWER LICENSE ALL-IN-ONE PC NOTES: X N XRW IG 208/120 3P 4W 60A = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION KVA 0.50 0.50 0.50 0.50 0.50 0.50 0.54 0.36 0.54 0.36 0.20 0.20 0.20 0.20 0.40 0.40 0.18 0.18 0.40 0.50 0.40 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 35.91 60A M.C.B. 10 KAIC SURFACE PH A 1.00 1.00 0.94 0.54 0.60 0.40 0.18 4.66 KVA LOADS PH B 1.00 1.00 0.54 0.56 0.60 0.40 0.50 4.60 PH C 1.00 0.68 0.72 0.30 0.40 0.18 0.40 3.68 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 0.50 0.50 0.50 0.50 0.50 0.18 0.40 0.18 0.18 0.18 0.36 0.10 0.40 0.40 0.00 0.00 0.00 0.00 0.00 0.00 0.00 12.94 Demand Load Amps = ELECTRICAL ROOM 60 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION NIKE DISPLAY SPECIAL SYSTEMS PHONE BD. ADT CELL BACK-UP SPECIAL SYSTEMS HONE BD. EMPLOYE TIME CLOCK FLOOR BOX FLOOR BOX SPACE SPACE SPACE SPACE SPACE SPACE SPACE 35.9 XRW XRW XRW XRW XRW X XRW X X X XRW X X X X X X X XRW,C X X X X XRW X X X X X X X X X X X VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION CHANDELIER LIGHTING CHANDELIER LIGHTING CHANDELIER LIGHTING CHANDELIER LIGHTING ALT 5 LIGHTS LUNCH ROOM OUTLETS LUNCH ROOM OUTLETS LUNCH ROOM OUTLETS LUNCH ROOM OUTLETS STORE MANAGER OUTLETS DEPT. MANAGER COPIER CHANDELIER LIGHTING CHANDELIER LIGHTING STOCKROOM OUTLETS COLUMN LIGHTS COLUMN LIGHTS BUILDING SIGNS BUILDING SIGNS BUILDING SIGNS BUILDING SIGNS NOTES: X N XRW C 208/120 3P 4W 225A PROVIDE SOLID NEUTRAL BUS & GROUND BAR. = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION = INDICATES CONTROLLED CIRCUIT BREAKER KVA 1.20 1.20 1.20 1.20 1.20 1.20 1.00 0.72 0.72 0.72 0.70 1.20 1.20 0.72 0.75 0.75 0.60 0.60 0.60 0.60 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 81.61 100A M.C.B. 10 KAIC SURFACE PH A 1.20 2.20 1.92 1.22 1.20 1.29 1.10 10.13 KVA LOADS PH B 1.70 1.00 1.54 1.22 2.20 1.25 1.10 10.01 PH C 2.20 1.56 1.44 0.95 1.26 1.10 0.75 9.26 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 0.00 0.50 1.00 1.00 0.00 0.36 0.72 0.54 0.72 0.50 0.50 0.25 0.00 1.00 0.54 0.54 0.50 0.50 0.50 0.50 0.15 29.40 Demand Load Amps = ELECTRICAL ROOM 100 LOAD DESCRIPTION SPARE LODGE SHOWCASE LIGHTING VESTIBULE LIGHTS VESTIBULE LIGHTS SPARE RESTROOMS GFI OUTLETS HEAD CASHIER OUTLETS COUNT ROOM OUTLETS DEPT. MANAGER OUTLETS GOLF TV GOLF TV HUNTING TV HUNTING TV VESTIBULE LIGHTS REELS SHOWCASE LIGHTING REELS SHOWCASE LIGHTING ELEVATOR LIGHTS FITTING ROOM LIGHTING FITTING ROOM LIGHTING ALT 6 LIGHTS 94.7 X X X X X X X X X X X X X X XRW,C XRW,C XRW,C XRW,C XRW,C X X X X X X X X X X X X X X X X X X X X X VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION BIKES/SKIS OUTLETS TEAM SPORTS OUTLETS TRACK CUSTOMER LTG TRACK CUSTOMER LTG TRACK CUSTOMER LTG TRACK CUSTOMER LTG COKE MACHINE SPORTS TV'S TRACK CUSTOMER LTG SALES OUTLETS SIGNAGE SIGNAGE SIGNAGE SIGNAGE ATHLETIC FOOTWEAR TV ATHLETIC FOOTWEAR TV MAIN EQUIPMENT RACK OUTLETS MAIN EQUIPMENT RACK OUTLETS FOOTWEAR TV'S FOOTWEAR TV'S BIKES/EXERCISE TV NOTES: X N XRW C 208/120 3P 4W 125A PROVIDE SOLID NEUTRAL BUS & GROUND BAR. = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION = INDICATES CONTROLLED CIRCUIT BREAKER KVA 1.00 1.08 0.76 0.97 0.65 1.08 0.75 0.75 0.97 1.08 0.60 0.60 0.60 0.60 0.50 0.50 0.50 0.50 0.50 0.50 1.00 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 94.01 125A M.C.B. 10 KAIC SURFACE PH A 1.54 2.05 1.75 2.27 1.68 1.50 1.30 12.09 KVA LOADS PH B 2.52 1.55 1.75 1.79 1.10 1.50 0.68 10.89 PH C 1.62 2.08 1.60 1.57 1.00 1.30 1.72 10.89 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 0.54 1.44 0.86 1.08 0.90 1.00 1.00 1.00 0.63 1.19 1.19 0.97 1.08 0.50 0.50 1.00 1.00 0.80 0.80 0.18 0.72 33.87 Demand Load Amps = MAIN ELECTRICAL ROOM 125 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION BIKE/STOCK OUTLETS LOSS PREVENTION WIREMOLD TRACK CUSTOMER LTG STOCK ROOM OUTLETS LOSS PREVENTION OUTLETS FOOTWEAR TV'S FOOTWEAR TV'S MALL ENTRY TV'S F6 AND L3 TRACK CUSTOMER LTG TRACK CUSTOMER LTG TRACK CUSTOMER LTG TRACK CUSTOMER LTG TRACK CUSTOMER LTG FITTING ROOM LIGHTS ADD ALT 5 LIGHTS TEAM SPORTS TV TEAM SPORTS TV DOCK RECEPTACLES RECEPTACLES LOSS PREVENTION NIKE DISPLAY 102.9 X X X X X X X X X X X X X XRW,C XRW X X X X X XRW XRW,C X X X X X X X X X X X X X X X XRW,C VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING SPARE EMPLOYEE LIGHTING SPARE SPARE NOTES: X N XRW C A2 480/277 3P 4W 225A PROVIDE SOLID NEUTRAL BUS & GROUND BAR. = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION = INDICATES CONTROLLED CIRCUIT BREAKER KVA 2.10 1.70 1.26 1.70 0.91 2.33 2.79 2.79 3.24 1.86 2.79 1.86 2.79 3.26 1.58 0.00 0.72 0.00 0.00 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 105.07 M.L.O. 18 KAIC SURFACE PH A 5.57 4.50 5.12 5.35 5.10 2.90 4.69 33.21 KVA LOADS PH B 4.43 3.09 5.25 4.59 5.12 1.32 1.76 25.54 PH C 4.02 3.24 6.05 5.02 6.50 1.92 1.87 28.60 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 2.33 2.33 2.33 3.24 1.40 2.33 2.79 2.46 3.26 2.11 2.73 2.23 3.24 2.33 3.24 1.32 1.32 1.20 2.59 1.76 1.87 87.35 Demand Load Amps = ELECTRICAL ROOM 225 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING GUN CASE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING 131.3 X X X X X X X X X X X X X X X X X X X X X X XRW,C X X X X X X X X X X X X X X X X X X X VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION EXTERIOR LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EXTERIOR LIGHTING EXTERIOR LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING NOTES: X N XRW C A1 480/277 3P 4W 225A = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION = INDICATES CONTROLLED CIRCUIT BREAKER KVA 1.86 0.50 3.60 1.74 0.75 0.75 1.86 2.33 2.33 0.93 1.86 3.26 2.33 2.33 2.43 3.18 3.26 2.33 3.26 2.79 0.46 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 99.67 M.L.O. 18 KAIC PRE-FABRICATED DIST. CENTER PH A 2.12 3.14 3.72 3.26 3.73 3.55 3.70 23.22 KVA LOADS PH B 1.64 3.54 5.12 4.19 5.95 3.56 4.65 28.65 PH C 5.28 3.33 5.59 6.05 5.79 2.63 2.32 30.99 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 0.26 1.14 1.68 1.40 2.79 2.58 1.86 2.79 3.26 2.33 2.33 2.79 1.40 3.62 3.36 0.37 0.30 0.30 0.44 1.86 1.86 82.86 Demand Load Amps = ELECTRICAL ROOM 150 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION EMPLOYEE LIGHTING DISPLAY CASE LTG 2ND FLOOR CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING CUSTOMER LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING EMPLOYEE LIGHTING STAIR LTG STAIR LTG STAIR LTG EXTERIOR LTG EXTERIOR LTG EXTERIOR LTG 124.6 X X X X X X X X X X X X X X X X X X X X X XRW,C X X X X X VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING NIGHT/EMERG LIGHTING SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPACE SPACE SPACE SPACE SPACE SPACE SPACE NOTES: X N XRW C AA1 480/277 3P 4W 100A = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION = INDICATES CONTROLLED CIRCUIT BREAKER KVA 2.83 2.83 2.83 1.70 2.26 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 25.02 M.L.O. 18 KAIC PRE-FABRICATED DIST. CENTER PH A 3.25 2.83 0.90 0.00 0.00 0.00 0.00 6.98 KVA LOADS PH B 4.03 1.70 0.90 0.00 0.00 0.00 0.00 6.63 PH C 2.83 3.46 0.90 0.00 0.00 0.00 0.00 7.19 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 1.20 1.20 0.00 0.00 0.00 1.20 0.90 0.90 0.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.80 Demand Load Amps = ELECTRICAL ROOM 100 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION VESTIBULE LIGHTS VESTIBULE LIGHTS SPARE SPARE SPARE EXTERIOR LIGHTS VESTIBULE LIGHTS VESTIBULE LIGHTS VESTIBULE LIGHTS SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 31.3 X X X X X X X XRW XRW XRW X X X X X X X X X X X X X XRW X X X VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION RECEPTACLES GOLF SECURITY TV GOLF FLOOR OUTLETS RECEPTACLES WORKROOM SALES FLOOR OUTLETS SALES FLOOR OUTLETS SALES FLOOR OUTLETS SALES FLOOR OUTLETS SALES FLOOR OUTLETS LINE WINDER HUNT/FISH OUTLETS HUNT/FISH OUTLETS CAMPING FLOOR OUTLETS DEPTH FINDER MAIN EQPT RACK OUTLETS GOLF EQPT RACK OUTLETS LODGE EQPT RACK OUTLETS NOTES: X N XRW 208/120 3P 4W 150A = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION KVA 1.69 0.36 0.18 0.25 0.36 0.00 0.90 0.90 0.54 0.90 0.72 0.18 0.72 0.72 0.36 1.20 0.50 0.50 0.50 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 53.68 150A M.C.B. 10 KAIC SURFACE PH A 2.05 1.72 0.72 0.54 0.18 0.36 0.50 6.07 KVA LOADS PH B 0.36 0.97 1.80 0.90 1.62 1.20 0.50 7.35 PH C 0.18 0.90 0.90 0.72 1.72 1.00 0.50 5.92 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 0.36 0.00 0.00 0.72 0.72 0.54 0.72 0.90 0.00 0.00 0.00 0.00 0.00 0.90 0.00 0.00 0.00 0.00 0.00 0.00 19.34 Demand Load Amps = ELECTRICAL ROOM 150 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION HITTRAX POWER SPARE SPARE CHECKOUTS CHECKOUTS GOLF OUTLETS GOLF OUTLETS GOLF OUTLETS SPARE SPARE SPARE SPARE SPARE CAMPING OUTLETS SPARE SPARE SPARE SPARE SPARE SPARE 42.7 XRW X X X X X X XRW XRW X X X X XRW X X X XRW X X X X X X X X X XRW X VOLTAGE: PH & WIRES: BUSSING AMPS: LOAD DESCRIPTION DOOR OPERATOR DOOR OPERATOR DOOR OPERATOR DOOR OPERATOR DOOR SENSORMATIC DOOR OPERATOR DOOR OPERATOR SALES FLOOR OUTLETS SALES FLOOR OUTLETS SALES FLOOR OUTLETS SALES FLOOR OUTLETS SALES FLOOR OUTLETS EXTERIOR OUTLETS NIKE DISPLAY LIGHTING FLOOR BUFFER BOWLING PRESS & SHARPENER SPARE NOTES: X N XRW 208/120 3P 4W 225A = INDICATES EXISTING CIRCUIT TO REMAIN = INDICATES NEW CIRCUIT BREAKER TO BE INSTALLED MATCHING EXISTING PANEL LISTING = INDICATES EXISTING CIRCUIT BREAKER SHALL BE USED FOR NEW CIRCUIT OR MADE SPARE FOLLOWING DEMOLITION KVA 0.18 0.60 0.60 0.50 0.50 0.36 1.00 0.50 0.50 0.72 0.72 0.54 0.72 1.08 0.00 1.00 1.00 1.00 0.75 0.00 CONNECTED AMPS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 MAINS: AIC RATING: MOUNTING: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 CCT 1 3 5 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 68.78 150A M.C.B. 10 KAIC SURFACE PH A 0.78 1.22 2.08 1.36 1.08 0.36 1.20 8.08 KVA LOADS PH B 1.20 1.58 0.86 1.62 1.08 1.36 1.25 8.95 PH C 1.20 1.44 0.86 0.72 1.58 1.20 0.75 7.75 CCT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 CONNECTED KVA: AMP 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 LOCATION: FEEDER AMPACITY: REMARKS: P 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 KVA 0.60 0.60 0.60 0.72 0.36 0.36 0.36 0.90 0.00 0.54 0.36 0.50 0.36 0.36 0.20 0.20 0.50 0.75 24.78 Demand Load Amps = ELECTRICAL ROOM 150 EXISTING PANEL TO BE MODIFIED AS SHOWN LOAD DESCRIPTION RECEPTACLES RECEPTACLES EXTERIOR OUTLETS EXERCISE FLOOR OUTLETS EXERCISE FLOOR OUTLETS EXERCISE FLOOR OUTLETS EXERCISE FLOOR OUTLETS EXTERIOR OUTLETS TEAM SPORTS FLOOR OUTLETS NOVAR EMS-1 NOVAR EMS-2 MESSAGING TELEPHONE SERVER 62.3 X X X XRW XRW XRW XRW X X X X XRW X X XRW XRW XRW X X X XRW Mar 26, 2021 - 17:37:36 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_E5.0.dwg Updated By: rvan E5.0 PANEL SCHEDULES PJN CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 25001 Emery Road, Suite #200 Warrensville Heights, Ohio 44128 Phone: 216-292-4696 Fax: 216-292-5874 Email: mail@mchenryassociates.com Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 05/11/21