HomeMy WebLinkAboutE07.03x1 3x1
3x1
3x2
4x1 4x1 4x1
4x1 4x1 4x1
4x2 4x2 3x2
4x1 4x1
4x1 4x1
3x2
4x1
4x1
3x1
3x1
49" TV
1 2 3
4 5
6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
G G
4.4 5
1
SCALE: 3/32" = 1'-0"
ΕΝΝΣς∆≅Θ
Θ∆Β∆ΗΥΗΜΦ
Λ≅ΗΜ ΡΣΝΒϑ
ΒΓϑΣ.Υ∆ΡΣΗΑΤΚ∆
Λ− ΜΗϑ∆ ΓΞΑΘΗΧ
Λ∆Μ ≅ΧΗΧ≅Ρ
Λ∆Μ Τ−≅−
ς− ΜΗϑ∆ ΓΞΑΘΗΧ
ΟΘΝΛΝΣΗΝΜ≅Κ
ΕΝΝΣς∆≅Θ ΡΣΝΒϑ
ςΝΛ∆Μ Τ−≅−
Β≅ΚΗ≅
ΕΝΝΣς∆≅Θ ΡΣΝΒϑ
ΥΘΡΣ
ςΝΛ∆Μ ≅ΧΗΧ≅Ρ
ς ΒΓ≅ΛΟΗΝΜ ς− ΧΡΦ ΑΘ≅ΜΧ
ςΝΛ∆Μ ΝΤΣΧΝΝΘ
Λ∆Μ ΝΤΣΧΝΝΘ
Λ∆Μ ΝΤΣΧΝΝΘ
ΞΝΤΣΓ ΝΤΣΧΝΝΘ
ΟΘΝΛΝΣΗΝΜ≅Κ
ΒΓϑΣ.Υ∆ΡΣΗΑΤΚ∆
ΒΓϑΣ.Υ∆ΡΣΗΑΤΚ∆
ΒΓϑΣ.Υ∆ΡΣΗΑΤΚ∆
ΒΓϑΣ.Υ∆ΡΣΗΑΤΚ∆
ΞΝΤΜΦ ≅ΣΓΚ∆Σ∆
ΑΝΝΣΡ
ΒΝΚΧ ς∆≅ΣΓ∆Θ ≅ΒΒ
ΑΝΟΗΡ
Λ− ΧΡΦ ΑΘ≅ΜΧ
A. MOUNT ALL WALL PHONES AT 48" AFF., UNLESS OTHERWISE NOTED
B. MOUNT ALL DESK PHONES AT 18" AFF., UNLESS OTHERWISE NOTED
C. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
D. ALL DATA CABLING SHALL BE WIRED FROM THE MDF OR IDF TO THE END
POINT BY VENDOR #13. VENDOR #13 SHALL PROVIDE THE DATA CABLING.
E. AUDIO/VISUAL- VENDOR #13 TO TAKE FEED FROM AUDIO/VISUAL VENDOR
#5 PAGING/AUDIO EQUIPMENT AND MAKE FINAL CONNECTION AT PAGE PAL
EQUIPMENT PRIOR LEAVING THE JOB SITE. THIS EQUIPMENT IS LOCATED AT
THE AV/MDF ROOM. VENDOR #13'S INSTALLATION TECH SHALL VERIFY WITH
STORE MANAGER THAT PAGING AND PHONE SYSTEMS OPERATE AS
REQUIRED.
F. VENDOR LIST-
TELEPHONE/DATA - VENDOR #13
PAGING/AUDIO/VISUAL - VENDOR #5
SECURITY - VENDOR #19
BUILDING MANAGEMENT - VENDOR #18
G. SURFACE MOUNTING OF LOW VOLTAGE WIRING IS PROHIBITED. ALL
WIRING TO BE IN CONDUIT AND CONCEALED IN WALLS. EXPOSED WIRING MAY
BE RUN ABOVE CEILINGS AND IN JOIST SPACE.
H. 3/4"C WITH 4" BY 4" J-BOX WITH SINGLE GANG MUD RING AT EACH DATA
LOCATION SHOWN. (TYPICAL OFFICE AREA AND SERVICE COUNTERS)
I. 3/4"C OFFSET AT 4" BY 4" J-BOX WITH SINGLE GANG MUD RING AT EACH
DATA LOCATION SHOWN. (TYPICAL SALES FLOOR)
J. ROUTE CONDUIT FROM DECK TO TOP OF VESTIBULE FOR SPEAKER WIRE
AND TRAFSYS.
K. ALL CONDUITS FOR LOW VOLTAGE WIRING SHALL BE PROVIDED WITH
BUSHINGS AND PULL STRINGS.
L. VENDOR #13 SHALL COORDINATE THE TELEPHONE COMPANY UTILITY
DEMARK LOCATION WITH THE ELECTRICAL CONTRACTOR PRIOR TO BID.
VENDOR #13 IS RESPONSIBLE FOR COMPLETE INSTALLATION OF 25 PAIR
TELEPHONE CABLE TO DICK'S SPORTING GOODS TELEPHONE BACKBOARD
FROM THE UTILITY DEMARK.
M. AP LOCATIONS SHOWN ARE FOR REFERENCE ONLY. OBTAIN EXACT
LOCATIONS FROM NEW STORE SUPPORT.
N. ALL COAX CABLES AND SPEAKER CABLES TO ROUTE TO AV RACK IN
DATA/AV ROOM. CAT6 CABLES CAN GO TO MDF OR IDF, WHICHEVER IS
NEAREST.
O. ALL TV LOCATIONS GET A COAX AND A CAT6 CABLE.
P. CONFIRM TRAFSYS COUNTER REQUIREMENTS WITH EQUIPMENT
INSTALLER. REQUIREMENTS ARE DETERMINED BY DOOR SIZE AND HEIGHT.
Q. ONE (1) #18/2 SPEAKER CABLE TO BE RUN BETWEEN DATA AND AV RACKS
FOR PAGING BY VENDOR #13.
R. ONE (1) 6-STRANDED MULTIMODE FIBER AND ONE (1) 25-PAIR CABLE TO BE
RUN BETWEEN MDF AND IDF BY VENDOR #13. CABLES TO BE TERMINATED
ON A 66 BLOCK OR VOICE PATCH PANEL.
S. ONE (1) 25-PAIR CABLE TO BE RUN BETWEEN MDF AND DMARK ON
TELEPHONE BACKBOARD BY VENDOR #13.
T. 4G ANTENNAE CABLE TO BE ROUTED TO ANTENNAE INSTALLED ON ROOF.
MOUNT ANTENNAE ON CONDUIT. CABLE TO BE ROUTED THROUGH RAIN
HEAD AT TOP OF CONDUIT TO DATA RACK IN DATA/AV ROOM. EQUIPMENT
SUPPLIED BY NEW STORE SUPPORT.
U. ALL ELEVATOR / ESCALATOR CABLES SHALL BE ROUTED TO DEMARK.
TERMINATE TO RELEVANT TELEPHONE NUMBERS AT DEMARK. LEAVE 30'
SERVICE LOOP AT ELEVATOR AND ESCALATOR LOCATIONS FOR
TERMINATION BY ELEVATOR AND ESCALATOR INSTALLERS.
V. ONE (1) CAT6 CABLE TO BE RUN BETWEEN DEMARK AND 2-WAY
COMMUNICATOR SYSTEM MAIN UNIT BY VENDOR #13. CONFIRM MAIN UNIT
LOCATION WITH VENDOR #2.
W. ALL WIRING SHALL BE ROUTED OVERHEAD IN JOIST SPACE UNLESS
NOTED OTHERWISE ON PLANS TO BE ROUTED BELOW GRADE (OR IN JOIST
1. VERIFY QUANTITY AND LOCATION OF INDYME WIRELESS CALL BOXES WITH DICK'S
SPORTING GOODS DESIGN TEAM AND VENDOR #5. COORDINATE INDYME ANTENNAE LOCATION
WITH VENDOR #13 AND VENDOR #5. PROVIDE CABLE TO INDYME SERVER AT AV/MDF ROOM.
2. ELECTRICAL CONTRACTOR TO CONFIRM LOCATIONS OF ALL IN SLAB ELECTRICAL/DATA WITH
DICK'S SPORTING GOODS' DESIGN TEAM 1 WEEK PRIOR TO ROUGH-IN.
3. DO NOT PROVIDE SEPARATE FLOORBOX FOR THIS FLOOR DATA OUTLET. INSTALL OUTLET IN
SECOND GANG OF THE 2 GANG FLOORBOX BEING INSTALLED AT THE SAME LOCATION FOR
POWER, REFERENCE E2.O. 1 GANG IS FOR A DUPLEX RECEPTACLE, THE OTHER GANG IS FOR
THE INDICATED DATA OUTLET.
4. PROVIDE JUNCTION BOX IN JOIST SPACE ABOVE HITTRAX BATTING CAGE FOR DATA WIRING
TO HITTRAX EQUIPMENT. PROVIDE 3/4" CONDUIT PAINTED MATTE BLACK ROUTED DOWN FROM
JUNCTION BOX TO HITTRAX EQUIPMENT DATA BOX. PROVIDE 2-CHANNEL NON-METALLIC BLACK
WIREMOLD ON EXTERIOR CAGE FROM FROM DATA BOX TO PC. COORDINATE JUNCTION BOX
AND CONDUIT / WIREMOLD ROUTING WITH G.C. / HITTRAX EQUIPMENT INSTALLER. LOW
VOLTAGE WIRING PROVIDED BY DSG LOW VOLTAGE VENDOR.
5. VERIFY QUANTITY AND LOCATION OF INDYME WIRELESS CALL BOXES WITH DICK'S
SPORTING GOODS DESIGN TEAM AND VENDOR #5. COORDINATE INDYME ANTENNAE LOCATION
WITH VENDOR #13 AND VENDOR #5. PROVIDE CABLE TO INDYME SERVER AT AV/MDF ROOM.
SEE DRAWING E7.1 FOR NOTES AND DETAILS.
5 I 5
5I I 5
3/4" CONDUIT WITH SINGLE GANG BOX AND COVER PLATE CENTER OF DOORWAY TOP OF DOOR. DS-150
IDF
XX
I
1
2 DATA
1 PHONE
D
2 DATA
1 PHONE
D
IDF
XX
2 DATA
D
2 DATA
1 PHONE
D
IDF
XX
3 DATA
1 PHONE
2 DATA
2 DATA
1 PHONE
D
IDF
XX
2 DATA
D
IDF
XX
2 DATA
1 PHONE
IDF
XX
2 DATA
1 PHONE
2 DATA
COAX CABLE TO AV ROOM AV EQUIPMENT RACK & (1) DATA CABLE TO MDF BY VENDOR #13. SEE DETAIL 8/E3.1A. (TYPICAL)
2 DATA
2 DATA
1 PHONE
IDF
XX
IDF
XX
5
I 5
Mar 26, 2021 - 17:37:44 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_E7.0,7.1.dwg Updated By: rvan
E7.0
1ST FLR TELEPHONE /
DATA SYSTEM PLAN
PJN
CONTRACTOR MUST VERIFY
DIMENSIONS ALL CLEARANCES IN AND FIELD
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
25001 Emery Road, Suite #200
Warrensville Heights, Ohio 44128
Phone: 216-292-4696
Fax: 216-292-5874
Email: mail@mchenryassociates.com
Issued for
Bid-Permit
03-26-21
T F
\pxql;216.520.1551
\pxql;216.520.1567
03-26-21
SM
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
05/11/21