FIXED CAMERA
PUBLIC VIEW MONITOR WITH NO BUILT-IN CAMERA
DEAD DROP
PUBLIC VIEW MONITOR W/ BUILT-IN CAMERA
COMPACT DEACTIVATOR W/ VERTICAL MOUNT
DEACTIVATOR (UNDER-COUNTER MOUNT)
EAS PEDESTAL - DUAL SYNERGY
EAS PEDESTAL - QUAD SYNERGY
CAMERA - PENDANT MOUNTED
CAMERA - 360 DEG
IDCP
IDPS
C
OH
P
P
GB
KB
T
R
S
M
M
PVM
PVM
(NO CAMERA)
D
MD
360 DEG
PEDESTAL POWER PACK
QTY SYMB DESCRIPTION
2
1
-
-
1
4
3
12
4
1
4
-
10
-
-
2
-
-
3
-
-
-
-
3
-
-
1
PHOTOELECTRIC BEAM - RECEIVER
PHOTOELECTRIC BEAM - TRANSMITTER
KNOX BOX
ZONE EXPANSION MODULE
DAYTIME ANNUNICATOR
KEYPAD - ALPHANUMERIC
KEYSWITCH
HI/LO AIR PRESSURE SUPERVISION
HI/LO TEMPERATURE SENSOR
TAMPER SWITCH
WATER SENSOR
GLASSBREAK
PANIC LIGHT
PANIC BUTTON
ROTATING BEACON
STROBE
SIREN/SOUNDER/STROBE
DOOR HORN
SPEAKER
DOOR MONITOR ALARM - KEYSWITCH
CURTAIN MOTION
OVERHEAD DOOR CONTACT / ROOF HATCH
DOOR CONTACT - SAFE
DOOR CONTACT - MAIN ENTRANCE
GATEWAY
PRINTER
POINT OF CONNECTION
CELLULAR DIALER
INTRUSION DETECTION POWER SUPPLY
INTRUSION DETECTION CONTROL PANEL
C
C
M
S
W
TS
T
AP
KP
KS
DTA
ZEM
MOTION DETECTOR - WIDE RANGE - LOADING DOCK
MOTION DETECTOR - WIDE RANGE - ALL AREAS (EXCEPT LD)
DOOR MOTION CONTACT DETECTOR - ALL - 360 DOORS DEG CEILING (EXCEPT MOUNTED MAIN ENTRANCE)
SYMB DESCRIPTION
CR
ES
2 2 CARD ELECTRIC READER STRIKE
SEE DRAWING E7.0 FOR NOTES AND DETAILS.
1. ALL EXTERIOR EMERGENCY EGRESS DOORS TO HAVE
DAYTIME ANNUNCIATOR AND SOUNDER INCLUDING
RECEIVING AREA DOORS.
2. WALL MOUNT PASSIVE INFRARED - @ 8'-6" AFF
3. ENSURE THAT ALL EXTERIOR DOORS ARE COVERED BY
MOTION DETECTORS.
4. THE FOLLOWING GENERAL GUIDELINES SHALL BE
FOLLOWED FOR WIRING INSTALLATION:
a. WIRING SHALL BE APPROPRIATELY COLOR-CODED WITH
PERMANENT WIRE MARKERS. COPPER CONDUCTORS SHALL
BE USED.
b. ALL CABLES, WHERE SUBJECT TO MECHANICAL DAMAGE,
WIRING SHALL BE ENCLOSED IN METAL CONDUIT OR
SURFACE METALLIC RACEWAY. (CHECK LOCAL CODES
AND/OR AHJ AUTHORITIES FOR LOCAL REQUIREMENTS.)
c. WIRE SIZE FOR FIRE INITIATING DEVICE CIRCUITS SHALL
NOT BE SMALLER THAN 16 AWG SOLID, 14 AWG FOR
SIGNALING LINE CIRCUITS (SLC).
d. IDC OR SLC WIRES SHALL NOT BE ENCLOSED IN
CONDUIT OR RACEWAYS CONTAINING "AC" WIRES. INSIDE
CONTROL PANEL, "AC" WIRES MUST BE APPROPRIATELY
SEPARATED.
e. WHERE EMI MAY INTERFERE WITH THE PROPER
OPERATION OF THE INITIATING CIRCUITS,
TWISTED/SHIELDED CABLE SHALL BE USED.
5. SEE E6.0 FOR SPECIAL SYSTEMS BACKBOARD DIAGRAM
6. FINAL LOCATION FOR CAMERAS SHALL BE VERIFIED BY
LOSS PREVENTION DISTRICT MANAGER:
ANDREA GUTHRIE (724) 273-3050
7. E.C. SHALL PROVIDE 3/4"C (WITH PULL WIRE) FROM EACH
SECURITY DEVICE TO ABOVE ACCESSIBLE CEILING. IF
DEVICE IS LOCATED IN AN AREA WITHOUT CEILING, THIS
E.C. SHALL STUB UP 3/4"C TO STRUCTURAL JOIST. ALL
SECURITY WIRING SHALL BE PROVIDED AND INSTALLED BY
SECURITY VENDOR #2. ALL WORK SHALL BE COORDINATED
WITH SECURITY VENDOR PRIOR TO ROUGH-IN. TYPICAL
THIS DWG.
8. SURFACE MOUNTING OF SECURITY SYSTEM WIRING IS
PROHIBITED. ALL WIRING TO BE IN CONDUIT AND
CONCEALED IN WALLS. EXPOSED WIRING MAY BE RUN
ABOVE CEILINGS AND IN JOIST SPACE.
9. CELLULAR BACKUP REQUIRED FOR ALL SECURITY
SYSTEMS.
10. E.C. SHALL INSTALL 7847I HONEYWELL INTERNET
\A1;"TIS" WILL NOT CONNECT TO NOVAR/EMS. LIGHT WILL TURN ON ANY BURGLAR ALARM. SEE TIS WORK PLAN FOR CONNECTION DETAILS.
∂
∂
∂
∂
∂
∂
∂
∂
∂
∂
\A1;E.C. SHALL PROVIDE 3/4" CONDUIT (WITH PULL WIRE) FROM
EACH SECURITY DEVICE TO ABOVE ACCESSIBLE CEILING. IF
DEVICE IS LOCATED IN AN AREA WITHOUT CEILING, THE E.C.
SHALL STUB UP 3/4" CONDUIT TO STRUCTURAL JOIST. ALL
SECURITY WIRING SHALL BE PROVIDED AND INSTALLED BY
SECURITY VENDOR. ALL WORK SHALL BE COORDINATED WITH
SECURITY VENDOR PRIOR TO ROUGH-IN. TYPICAL THIS
%%UNOTE:
5 I 5
5I I 5
1 PHONE, 2 DATA IN FLOOR UNDER FIXTURE
2 3
2 DATA, 18"
1 HDMI
1 CAT 6
PROVIDE (2) 4" SQUARE J-BOXES WITH SINGLE GANG MUD
RINGS AND 1"C DOWN WALL.
(1) J-BOX REQUIRED FOR HDMI TO CAT6 CONVERTER.
(1) J-BOX REQUIRED FOR IDF DATA CABLING AND DATA
CABLE TO THE TV. J-BOXES TO BE BETWEEN THE BLOCKING
AND CONCEALED BEHIND TV. SEE DETAIL 5/E3.1
COAX CABLE TO MDF AND (1) DATA CABLE TO MDF/IDF BY VENDOR #13
PROVIDE (2) 4" SQUARE J-BOXES WITH SINGLE
GANG MUD RINGS AND 1"C DOWN WALL.
(1) J-BOX REQUIRED FOR HDMI TO CAT6
CONVERTER.
(1) J-BOX REQUIRED FOR IDF DATA CABLING AND
1 DATA
ALL HITTRAX ELECTRICAL CONDUIT / BOXES ARE TO BE PAINTED MATTE BLACK. DEVICES ARE TO BE BLACK.
4
DATA OUTLET FOR ALL-IN-ONE PC (1 DATA)
3
Mar 16, 2021 - 17:29:27 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_Setup.dwg Updated By: rvan
PJN
CONTRACTOR MUST VERIFY
DIMENSIONS ALL CLEARANCES IN AND FIELD
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
25001 Emery Road, Suite #200
Warrensville Heights, Ohio 44128
Phone: 216-292-4696
Fax: 216-292-5874
Email: mail@mchenryassociates.com
Issued for
Bid-Permit
03-26-21
T F
\pxql;216.520.1551
\pxql;216.520.1567
03-26-21
SM
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
E7.1
2ND FLR TELEPHONE /
DATA SYSTEM PLAN
05/11/21