Loading...
HomeMy WebLinkAboutE07.1BATTING CAGE WORKSTATION 55" TV 8 A 1 2 3 4 5 6 7 B C D E F A B C D E F G G 4.4 5 1 SCALE: 3/32" = 1'-0" Ο≅ΧΧΚ∆ ΡΟΝΘΣΡ ΑΗϑ∆Ρ ΝΤΣΧΝΝΘ Θ∆Β ΡΟΝΘΣ Φ≅Λ∆Ρ Σ≅ΒϑΚ∆ Β≅ΛΟΗΜΦ Θ.Θ Θ≅ΒΠΤ∆Σ ΡΟΝΘΣΡ ΝΟ∆Μ ΣΝ Α∆ΚΝς ΝΟ∆Μ ΣΝ Α∆ΚΝς ΟΘΝΛΝΣΗΝΜ≅Κ ΝΕΕΗΒ∆Ρ ςΝΛ∆Μ ΦΝΚΕ ≅ΟΟΚ ΦΝΚΕ ΡΣΝΒϑ ΕΗΣΜ∆ΡΡ ΡΓΝΟ Λ∆Μ ΦΝΚΕ ≅ΟΟΚ ΦΝΚΕ ΟΘΝ ΡΓΝΟ Λ∆Μ ΦΝΚΕ ≅ΟΟΚ ΦΝΚΕ ΟΘΝ ΡΓΝΟ ΤΜΝΒΒΤΟΗ∆Χ ΤΜΝΒΒΤΟΗ∆Χ ΚΗΒ∆ΜΡ∆Χ ΚΗΒ∆ΜΡ∆Χ Σ∆≅Λ ΡΟΝΘΣΡ Σ∆≅Λ ΡΟΝΘΣΡ Σ∆≅Λ ΡΟΝΘΣΡ ΕΗΣ ΘΛ ΕΗΣ ΘΛ Λ≅ΗΜ ΡΣΝΒϑ Λ∆Μ ΦΝΚΕ ≅ΟΟΚ FIXED CAMERA PUBLIC VIEW MONITOR WITH NO BUILT-IN CAMERA DEAD DROP PUBLIC VIEW MONITOR W/ BUILT-IN CAMERA COMPACT DEACTIVATOR W/ VERTICAL MOUNT DEACTIVATOR (UNDER-COUNTER MOUNT) EAS PEDESTAL - DUAL SYNERGY EAS PEDESTAL - QUAD SYNERGY CAMERA - PENDANT MOUNTED CAMERA - 360 DEG IDCP IDPS C OH P P GB KB T R S M M PVM PVM (NO CAMERA) D MD 360 DEG PEDESTAL POWER PACK QTY SYMB DESCRIPTION 2 1 - - 1 4 3 12 4 1 4 - 10 - - 2 - - 3 - - - - 3 - - 1 PHOTOELECTRIC BEAM - RECEIVER PHOTOELECTRIC BEAM - TRANSMITTER KNOX BOX ZONE EXPANSION MODULE DAYTIME ANNUNICATOR KEYPAD - ALPHANUMERIC KEYSWITCH HI/LO AIR PRESSURE SUPERVISION HI/LO TEMPERATURE SENSOR TAMPER SWITCH WATER SENSOR GLASSBREAK PANIC LIGHT PANIC BUTTON ROTATING BEACON STROBE SIREN/SOUNDER/STROBE DOOR HORN SPEAKER DOOR MONITOR ALARM - KEYSWITCH CURTAIN MOTION OVERHEAD DOOR CONTACT / ROOF HATCH DOOR CONTACT - SAFE DOOR CONTACT - MAIN ENTRANCE GATEWAY PRINTER POINT OF CONNECTION CELLULAR DIALER INTRUSION DETECTION POWER SUPPLY INTRUSION DETECTION CONTROL PANEL C C M S W TS T AP KP KS DTA ZEM MOTION DETECTOR - WIDE RANGE - LOADING DOCK MOTION DETECTOR - WIDE RANGE - ALL AREAS (EXCEPT LD) DOOR MOTION CONTACT DETECTOR - ALL - 360 DOORS DEG CEILING (EXCEPT MOUNTED MAIN ENTRANCE) SYMB DESCRIPTION CR ES 2 2 CARD ELECTRIC READER STRIKE SEE DRAWING E7.0 FOR NOTES AND DETAILS. 1. ALL EXTERIOR EMERGENCY EGRESS DOORS TO HAVE DAYTIME ANNUNCIATOR AND SOUNDER INCLUDING RECEIVING AREA DOORS. 2. WALL MOUNT PASSIVE INFRARED - @ 8'-6" AFF 3. ENSURE THAT ALL EXTERIOR DOORS ARE COVERED BY MOTION DETECTORS. 4. THE FOLLOWING GENERAL GUIDELINES SHALL BE FOLLOWED FOR WIRING INSTALLATION: a. WIRING SHALL BE APPROPRIATELY COLOR-CODED WITH PERMANENT WIRE MARKERS. COPPER CONDUCTORS SHALL BE USED. b. ALL CABLES, WHERE SUBJECT TO MECHANICAL DAMAGE, WIRING SHALL BE ENCLOSED IN METAL CONDUIT OR SURFACE METALLIC RACEWAY. (CHECK LOCAL CODES AND/OR AHJ AUTHORITIES FOR LOCAL REQUIREMENTS.) c. WIRE SIZE FOR FIRE INITIATING DEVICE CIRCUITS SHALL NOT BE SMALLER THAN 16 AWG SOLID, 14 AWG FOR SIGNALING LINE CIRCUITS (SLC). d. IDC OR SLC WIRES SHALL NOT BE ENCLOSED IN CONDUIT OR RACEWAYS CONTAINING "AC" WIRES. INSIDE CONTROL PANEL, "AC" WIRES MUST BE APPROPRIATELY SEPARATED. e. WHERE EMI MAY INTERFERE WITH THE PROPER OPERATION OF THE INITIATING CIRCUITS, TWISTED/SHIELDED CABLE SHALL BE USED. 5. SEE E6.0 FOR SPECIAL SYSTEMS BACKBOARD DIAGRAM 6. FINAL LOCATION FOR CAMERAS SHALL BE VERIFIED BY LOSS PREVENTION DISTRICT MANAGER: ANDREA GUTHRIE (724) 273-3050 7. E.C. SHALL PROVIDE 3/4"C (WITH PULL WIRE) FROM EACH SECURITY DEVICE TO ABOVE ACCESSIBLE CEILING. IF DEVICE IS LOCATED IN AN AREA WITHOUT CEILING, THIS E.C. SHALL STUB UP 3/4"C TO STRUCTURAL JOIST. ALL SECURITY WIRING SHALL BE PROVIDED AND INSTALLED BY SECURITY VENDOR #2. ALL WORK SHALL BE COORDINATED WITH SECURITY VENDOR PRIOR TO ROUGH-IN. TYPICAL THIS DWG. 8. SURFACE MOUNTING OF SECURITY SYSTEM WIRING IS PROHIBITED. ALL WIRING TO BE IN CONDUIT AND CONCEALED IN WALLS. EXPOSED WIRING MAY BE RUN ABOVE CEILINGS AND IN JOIST SPACE. 9. CELLULAR BACKUP REQUIRED FOR ALL SECURITY SYSTEMS. 10. E.C. SHALL INSTALL 7847I HONEYWELL INTERNET \A1;"TIS" WILL NOT CONNECT TO NOVAR/EMS. LIGHT WILL TURN ON ANY BURGLAR ALARM. SEE TIS WORK PLAN FOR CONNECTION DETAILS. ∂ ∂ ∂ ∂ ∂ ∂ ∂ ∂ ∂ ∂ \A1;E.C. SHALL PROVIDE 3/4" CONDUIT (WITH PULL WIRE) FROM EACH SECURITY DEVICE TO ABOVE ACCESSIBLE CEILING. IF DEVICE IS LOCATED IN AN AREA WITHOUT CEILING, THE E.C. SHALL STUB UP 3/4" CONDUIT TO STRUCTURAL JOIST. ALL SECURITY WIRING SHALL BE PROVIDED AND INSTALLED BY SECURITY VENDOR. ALL WORK SHALL BE COORDINATED WITH SECURITY VENDOR PRIOR TO ROUGH-IN. TYPICAL THIS %%UNOTE: 5 I 5 5I I 5 1 PHONE, 2 DATA IN FLOOR UNDER FIXTURE 2 3 2 DATA, 18" 1 HDMI 1 CAT 6 PROVIDE (2) 4" SQUARE J-BOXES WITH SINGLE GANG MUD RINGS AND 1"C DOWN WALL. (1) J-BOX REQUIRED FOR HDMI TO CAT6 CONVERTER. (1) J-BOX REQUIRED FOR IDF DATA CABLING AND DATA CABLE TO THE TV. J-BOXES TO BE BETWEEN THE BLOCKING AND CONCEALED BEHIND TV. SEE DETAIL 5/E3.1 COAX CABLE TO MDF AND (1) DATA CABLE TO MDF/IDF BY VENDOR #13 PROVIDE (2) 4" SQUARE J-BOXES WITH SINGLE GANG MUD RINGS AND 1"C DOWN WALL. (1) J-BOX REQUIRED FOR HDMI TO CAT6 CONVERTER. (1) J-BOX REQUIRED FOR IDF DATA CABLING AND 1 DATA ALL HITTRAX ELECTRICAL CONDUIT / BOXES ARE TO BE PAINTED MATTE BLACK. DEVICES ARE TO BE BLACK. 4 DATA OUTLET FOR ALL-IN-ONE PC (1 DATA) 3 Mar 16, 2021 - 17:29:27 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_Setup.dwg Updated By: rvan PJN CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 25001 Emery Road, Suite #200 Warrensville Heights, Ohio 44128 Phone: 216-292-4696 Fax: 216-292-5874 Email: mail@mchenryassociates.com Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 E7.1 2ND FLR TELEPHONE / DATA SYSTEM PLAN 05/11/21