HomeMy WebLinkAboutED2.01 2 3 4 5 6 7 8 A B C D E F A B C D E F G G 4.4 5 1 FIRST FLOOR POWER DEMOLITION PLAN SCALE: 3/32" = 1'-0" A. THIS CONTRACTOR SHALL PERFORM ALL DEMOLITION OF EXISTING ELECTRICAL SYSTEMS AS INDICATED ON ELECTRICAL AND ARCHITECTURAL PLANS OR NECESSARY FOR THE PROJECT. REMOVE FROM SITE AND PROPERLY DISPOSE OF ALL MATERIAL AND DEBRIS FROM THIS WORK. B. DEMOLITION DRAWINGS ARE GENERAL IN NATURE SHOWING THE SCOPE OF DEMOLITION WORK. CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE QUANTITY OF DEVICES, OUTLETS, CONNECTIONS, ETC. ALL EQUIPMENT AND DEVICES ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE OR ARE NO LONGER REQUIRED FOR FINISHED CONSTRUCTION. ALL EXISTING CONDUIT, WIRE AND DEVICES IN PROJECT AREAS NO LONGER REQUIRED SHALL BE REMOVED AND DISPOSED OF. REMOVE CONDUITS BEYOND NEW SURFACES. REMOVE ALL EXISTING WIRE FROM CONDUIT BACK TO POINT OF COMMON USE OR TO PANELS. LABEL EXISTING CIRCUIT BREAKERS "SPARE" IF NOT REUSED FOR NEW WORK. C. DISCONNECT EXISTING EQUIPMENT IN BUILDING THAT IS TO BE REMOVED UNDER OTHER SECTIONS. REMOVE DATA AND PHONE CABLING SYSTEM AS DIRECTED BY OWNER. NO CABLES SHALL BE REMOVED OR CUT WITHOUT APPROVAL FROM OWNER. ANY EXISTING CABLES TO REMAIN SHALL BE SUPPORTED FROM STRUCTURE BEFORE CEILING REMOVAL. D. PATCH ALL SURFACES TO MATCH SURROUNDING FOR DEVICES TO BE REMOVED FROM EXISTING WALLS TO BE MAINTAINED. EXISTING ROUGH-IN BOXES IN WALL TO REMAIN MAY BE REUSED IF CODE COMPLYING AND APPROVED FOR LOCATION BY ARCHITECT. E. THE OWNER RESERVES THE RIGHT OF SALVAGE FOR ALL EXISTING ELECTRICAL EQUIPMENT PRIOR TO DEMOLITION, THE CONTRACTOR SHALL REVIEW ALL MATERIALS AND DELIVER TO THE OWNER THOSE REQUIRED IN THEIR EXISTING CONDITION. ALL OTHER MATERIAL SHALL BE REMOVED BY THIS CONTRACTOR. F. ALL CIRCUITS WHICH ARE REQUIRED TO REMAIN ACTIVE SHALL BE MAINTAINED OR REWORKED AS REQUIRED. ANY EXISTING CIRCUITS OR CABLING SYSTEMS SERVING AREAS NOT AFFECTED BY DEMOLITION SHALL BE MAINTAINED. ALL CIRCUITS SHALL BE VERIFIED WITH EXISTING DRAWINGS AND ACTUAL FIELD CONDITIONS PRIOR TO BEGINNING DEMOLITION. G. CONTRACTOR MAY OPTION TO REUSE WIRING WHEN FEASIBLE WHERE EQUIPMENT IS BEING REMOVED AND REPLACED IN THE SAME LOCATION. E.C. SHALL REFERENCE NEW WORK DRAWINGS TO SEE IF CIRCUITS ARE REUSED. IF WIRING IS IN ACCEPTABLE CONDITION, IT MAY BE USED TO REFEED NEW OR RELOCATED EQUIPMENT. H. STORE TO REMAIN OPEN DURING DEMOLITION AND CONSTRUCTION. G.C. / E.C. TO GO OVER CONSTRUCTION PHASING SCHEDULE WITH DICK'S SPORTING GOODS CONSTRUCTION MANAGER. I. CONTRACTOR TO MAINTAIN ALL LOW VOLTAGE SYSTEM DEVICES 'X' = INDICATES EXISTING DEVICE TO REMAIN. 'XR' = INDICATES EXISTING DEVICE TO BE REMOVED, INCLUDING ALL CONDUIT AND WIRING BACK TO PANEL OR POINT OF COMMON USAGE. 'XRL' = INDICATES EXISTING DEVICE TO BE REMOVED AND RELOCATED, REWIRE WITH LIKE KIND OR AS SHOWN ON DRAWING. CORRESPONDS WITH 'XRN'. 'XRN' = INDICATES NEW LOCATION OF RELOCATED EQUIPMENT. CORRESPONDS WITH 'XRL'. XRW = INDICATES EXISTING DEVICE TO BE REWORKED. REWORK AS SHOWN OR REPLACE EXISTING DEVICE WITH NEW AND REWIRE AS INDICATED. XRD = INDICATES EXISTING DEVICE TO BE DISCONNECTED AND ALL CONDUIT AND WIRING TO BE REMOVED. CTX = INDICATES CONNECT TO EXISTING CIRCUIT(S). {1. ALL EXISTING ELECTRICAL DEVICES IN THIS AREA ARE EXISTING TO REMAIN 'X'. MAINTAIN ALL EXISTING CONTROLS AND RELATED WIRING BACK TO PANELS OR POINT OF COMMON USAGE. 2. E.C. TO COMPLETELY DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL DEVICES, EQUIPMENT WITHIN THIS AREA, UNLESS NOTED OTHERWISE. ALL DEVICES AND RELATED WIRING, CONDUIT, BOXES SHALL BE REMOVED. REFER TO GENERAL DEMOLITION NOTES FOR FULL SCOPE OF WORK. REFER TO NEW WORK PLANS. 3. THIS AREA IS TO RECEIVE COSMETIC UPDATES. REMOVE AND THEN RE-INSTALL DEVICES TO PERMIT NEW FINISHES. 4. REMOVE AND/OR REWORK ELECTRICAL CIRCUITS WHERE WALLS AND/OR MILLWORK ARE REMOVED AS REQUIRED. 5. NOT USED. 6. E.C. TO COMPLETELY DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL DEVICES, EQUIPMENT WITHIN CASHWRAP COUNTERS IN THIS AREA, UNLESS NOTED OTHERWISE. ALL DEVICES AND RELATED WIRING, CONDUIT, BOXES SHALL BE REMOVED. REFER TO GENERAL DEMOLITION NOTES FOR FULL SCOPE OF WORK. SOME CIRCUITS MAY BE REUSED FROM THIS AREA FOR DEVICES IN NEW CASHWRAP COUNTERS. REFER TO NEW WORK PLANS.} 1 1 4 4 4 4 4 4 4 6 6 6 6 2 2 Mar 26, 2021 - 17:38:09 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_ED2.0,2.1.dwg Updated By: rvan ED2.0 FIRST FLOOR POWER DEMO PLAN PJN CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 25001 Emery Road, Suite #200 Warrensville Heights, Ohio 44128 Phone: 216-292-4696 Fax: 216-292-5874 Email: mail@mchenryassociates.com Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 05/11/21