HomeMy WebLinkAboutH2.0ACOUSTIC ELBOW WITH VOLUME MANUAL TAKE-OFF TO TO 45%%127 TAKE-OFF AIRFOIL FITTING 30%%127 INCLUDES LINING. 1. DASHED LINE INDICATES 1" INTERIOR NOTED. DUCT SIZE IS EXTERIOR AND ACOUSTIC LINING UNLESS OTHERWISE %%UNOTES: FLEXIBLE MAX. LENGTH = 48" DUCT BRANCH DIFFUSER TO TRANSITION MVD TO (NOTE #1) TAKE-OFF LINED 45%%127 MVD DOUBLE SINGLE 3 TYPICAL DUCT TAKE-OFF DETAIL SCALE: NONE A. SEAL VOID BETWEEN WALL AND ALL DUCT PENETRATIONS AIRTIGHT. B. ACOUSTIC LINE AIR TRANSFER DUCTS WITH 1/2" ACOUSTIC LINING. DUCT DIMENSIONS ARE EXTERIOR AND INCLUDE LINING. C. ALL GRILLES SHALL BE FURNISHED WITH FRAMES COMPATIBLE WITH WALL OR CEILING CONSTRUCTION D. REFER TO MECHANICAL FLOOR PLANS FOR MOUNTING HEIGHTS OF ALL WALL MOUNTED GRILLES. E. WHEN GRILLE IS ABOVE 10'-0" A.F.F. INSTALL GRILLE SO BLADES ANGLE UP ON FACE. F. ALL GRILLES ON SALES FLOOR SHALL BE INSTALLED ABOVE PAINT BREAK LINE UNLESS INDICATED OTHERWISE ON FLOOR PLAN. {\LNOTES FOR ALL AIR TRANSFER DUCTS}: GRILLE TYP. (2) %UATD-1 SECTION VIEW WALL NOTE: INSTALL GRILLE SO BLADES ANGLE UP ON FACE G-1, WALL DUCT SLEEVE. AIR TRANSFER DUCT OPENING SHALL MATCH GRILLE SIZE. REFER TO DRAWING H1.0 FOR GRILL SIZES. %%UATD-1 PLAN VIEW WALL GRILLE TYP. (2) G-1, WALL ATD-1 2 AIR TRANSFER DUCT DETAILS SCALE: NONE DIFFUSER TYPE AS NOTED ABOVE GRILLE, REGISTER, OR MANUFACTURER AIR QUANTITY DIFFUSER 1. DESIGNATIONS ON PLANS AS FOLLOWS: G-1 MARK DIFFUSER NECK SIZE OR GRILLE/REGISTER SIZE. DAMPER AS NOTED TITUS 350-RL AS NOTED SURFACE HORIZ. BAR NA CFM & MODEL # SIZE NECK TYPE FACE TYPE FRAME PATTERN NO STEEL TRANSFER OFF-WHITE MATERIAL SERVICE FINISH NOTES G-1, 12x12 400 CFM NOTES: SR-1 300-RL DEFLECTION AS NOTED TITUS AS NOTED SURFACE HORIZ. BAR DOUBLE YES STEEL SUPPLY OFF-WHITE 'XR' OR EXISTING TO BE REMOVED T GH CO S INDICATED ON FLOOR PLAN AND DRAWINGS. CONDUIT PER N.E.C. EQUIPMENT TAG UNDERCUT DOOR, REFER TO ARCHITECTURAL SPECIFICATIONS. ALL WIRING TO BE IN LOUVERED DOOR, REFER TO ARCHITECTURAL DRAWINGS. X SQUARE FEET OF FREE AREA. S ONE INSTALLED (1) HOUR AND TIMER WIRED WALL BY SWITCH. EC. FURNISHED BY MC. X X LD X.XX%%159 F.A. UC FD MD-X EXISTING, RELOCATED, SHOWN IN NEW LOCATION EXISTING TO BE RELOCATED EXISTING TO BE ABANDONED IN PLACE AND WIRED BY EC. THERMOSTAT. FURNISHED BY MC. INSTALLED INDICATES CODED NOTE CO-2 SENSOR TO BE FURNISHED BY MC. INSTALLED AND WIRED BY EC. NOVAR GLOBAL HUMIDITY SENSOR. REFER TO ELECTRICAL DWGS FOR DETAILS. NOVAR INDOOR TEMPERATURE SENSOR. REFER TO ELECTRICAL DWGS FOR DETAILS. NOVAR TEMPERATURE SENSOR. REFER TO ELECTRICAL DWGS FOR DETAILS. ACCESS DOOR LOCATED, INSTALLED AND WIRED AS UNDER ALARM. DETECTOR SHALL BE DUCT SMOKE DETECTOR TO SHUT DOWN UNIT 'UL' LISTED FIRE DAMPER WITH DUCT MOTORIZED DAMPER, 120 VOLT S 'XNL' OR 'XRL' OR 'XA' OR 2 HP HORSE POWER LOW PRESSURE GAS PIPING REGULATED 2 PSI GAS PIPING EXISTING TO REMAIN FIRE PROTECTION CONTRACTOR ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR 'X' OR RPG-2# G EC MC FPC PC KILOWATTS OUTSIDE AIR LINEAR DIFFUSER PRESSURE OPERABLE WEIGHT ROOF OPENING RETURN AIR SUPPLY REGISTER SUPPLY AIR ROOFTOP UNIT STATIC PRESSURE THOUSAND BTU/HOUR MANUAL VOLUME DAMPER UNIT HEATER THERMOSTAT GC GENERAL CONTRACTOR UH T'STAT SR RTU SA SP RO RA PRESS. OP. WT. OA MVD MBH LD KW HTG' HEATING CEILING DIFFUSER DIAMETER CORRIDOR EXHAUST AIR DRAWING EXHAUST EFFICIENCY EXHAUST FAN AIR TRANSFER DUCT ENERGY EFFICIENCY RATIO DRUM LOUVER PLENUM DIFFUSER SYSTEM CABINET UNIT HEATER CUBIC FEET PER MINUTE EXTERNAL STATIC PRESSURE ABOVE FINISHED FLOOR EXH. G E.S.P. EFF. GRILLE EER EF EA DWG CUH DIA DLPD CORR. CFM ATD CD AFF UNDERWRITER'S LABORATORY TYPICAL UL TYP. TOP OF DEG DEGREES B' BOTTOM OF CONN. CONNECT / CONNECTION H LENNOX HUMIDITY SENSOR. REFER TO ELECTRICAL DWGS FOR DETAILS. 1 HVAC LEGEND SCALE: NONE VOLTS UNIT NO. FLA MCA MOCP PHASE LOCATION SERVES UNIT POWER EXT. SP O.A. CFM HP (IN WC) CFM SUPPLY FAN TOTAL 225 HEATING NOMINAL TONS EER/SEER MBH COOLING COIL REMARKS OPEN SALES ROOF RTU-2XA RTU-3X OPEN SALES ROOF SALES RTU-4X OPEN SALES ROOF SALES RTU-5X RTU-6X OPEN SALES ROOF RTU-7X OPEN SALES ROOF RTU-1X OPEN SALES ROOF SALES 3 460 3 460 8,000 5 57 25 470 LGC-300H 3 460 77 3 460 3 460 3 460 30 1, 2, 3 RTU-8X RTU-9X OPEN SALES ROOF OPEN SALES ROOF SALES OFFICES SALES 3 460 3 460 57 57 77 18 77 8,000 8,000 13,000 13,000 13,000 13,000 2,100 25 25 30 30 470 470 470 470 LGC-300H LGC-300H LGA-360H LGA-360H LGA-060S LGA-360H 30 LGA-360H 5 77 125 470 470 5 5 10 10 10 10 2 EXISTING EQUIPMENT (LENNOX) REMARKS: {1. EXISTING ROOFTOP UNITS TO REMAIN. 2. MAINTAIN EXISTING OUTSIDE AIR SETTING. }3. MAINTAIN EXISTING SMOKE DETECTORS. 4. CONTRACTOR SHALL PERFORM ROUTINE SERVICE INSPECTION OF EXISTING ROOFTOP UNIT TO BE REUSED FOR THIS PROJECT. LUBRICATE BEARINGS, SERVICE CONTROL SYSTEMS, REPLACE FAN BELTS AS REQUIRED, CLEAN AND COMB EVAPORATOR AND CONDENSER COILS, CLEAN CONDENSATE DRAIN AND PAN, AND INSTALL NEW FILTERS AFTER COMPLETION OF CONSTRUCTION. ADD REFRIGERANT AS REQUIRED TO MEET MANUFACTURER'S RECOMMENDED OPERATING CHARGE. EQUIPMENT SHALL BE PLACED IN FULL OPERATION WITH CONTROLS CALIBRATED UPON COMPLETION OF PROJECT. SUBMIT A WRITTEN REPORT TO OWNER OF ANY MAJOR COMPONENT FAILURES OR ANTICIPATED COMPONENT FAILURES. REPORT SHALL INCLUDE COST INCLUDING LABOR TO SERVICE ALL ITEMS NOT OTHERWISE LISTED ABOVE. 5. INCLUDE REMARK 4 FOR ROOFTOP UNIT 9X FOR ADD/ALT #8. 1, 2, 3 1, 2, 3, 5 1, 2, 3, 4 1, 2, 3 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 CFM UNIT NO. REMARKS: EF-3X WATTS LOCATION SERVES PHASE VOLTS OR HP TYPE EXHAUST FAN SCHEDULE (EXISTING) TYPE EXT. BLADE FAN RPM DRIVE (MAKE & MODEL) DESIGN EQUIPMENT STOCK ELEVATOR 115 IN LINE 880 WEIGHT REMARKS EF-1X ROOF RESTROOMS 115 DOME 750 {1. EXISTING EXHAUST FAN TO REMAIN. MAINTAIN EXISTING CONTROL SEQUENCE. } EF-4X ROOF \pxqc;ELECT ROOM 115 DOME 400 EF-5X SP ROOF \pxqc;GOLF STOCK 115 DOME 880 EF-2X ROOF JAN. CLOSET 115100 DOME OPEN SALES ROOF SALES 57 5 460 8,000 5 25 470 LGC-300H EF-6X STOCKROOM VIDEO 115 IN LINE 400 SALES SALES UNIT NO. LOCATION HEATER KW VOLTS PHASE AMPS ELECTRICAL CFM (MAKE & MODEL) EQUIPMENT DESIGN ARRANGEMENT MOUNTING REMARKS CUH-1X STAIR SURFACE, WALL 277 5.0 CUH-2X STAIR SURFACE, WALL 277 5.0 1 CUH-3X STAIR SURFACE, WALL 277 4.8 CUH-4X VESTIBULE SURFACE, WALL 277 4.8 CUH-5X VESTIBULE 277 SURFACE, WALL 4.8 CUH-6X VESTIBULE SURFACE, WALL 277 4.8 CUH-7X VESTIBULE SURFACE, WALL 277 4.8 CUH-8X VESTIBULE SURFACE, WALL 277 4.8 1 REMARKS: {1. EXISTING HEATER TO REMAIN. MAINTAIN EXISTING CONTROL SEQUENCE. } HEATER INPUT UNIT NO. LOCATION VOLTS PHASE AMPS ELECTRICAL HP (MAKE & MODEL) EQUIPMENT DESIGN REMARKS UH-1X STOCK 120 100 UH-2X STOCK 120 100 1 REMARKS: {1. EXISTING HEATER TO REMAIN. MAINTAIN EXISTING CONTROL SEQUENCE. } H.V.A.C. GENERAL NOTES: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING PROCESS AND FIELD VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL TAKE ALL INTERFERENCES INTO CONSIDERATION. PROVIDE ALL NECESSARY OFFSETS OR TRANSITIONS WITH EQUIVALENT AREAS TO MATCH DUCT SIZES AS INDICATED ON DRAWINGS. B. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES RELATED TO INSTALLATION OF THE WORK. C. CONTRACTOR IS RESPONSIBLE TO AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE LATEST STATE CODES, TOWNSHIP, AND NFPA, O.S.H.A., AND THE RULES AND REGULATIONS OF ALL CITY, STATE, AND FEDERAL AUTHORITIES HAVING JURISDICTION. PROVIDE OWNER WITH CERTIFICATES OF INSPECTION. D. CONTRACTOR SHALL BE LICENSED, TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF MECHANICAL SYSTEMS, INCLUDING DUCTS, PIPING AND EQUIPMENT. UNCERTIFIED PERSONS MAY PERFORM MECHANICAL INSTALLATIONS ONLY WHEN UNDER DIRECT SUPERVISION AND RESPONSIBILITY OF A CERTIFIED INSTALLER OR LICENSED CONTRACTOR. VERIFICATION OF CERTIFICATION AND LICENSES ARE REQUIRED. E. THESE DRAWINGS INDICATE THE SIZE AND GENERAL LOCATION OF WORK. SCALED DIMENSIONS SHALL NOT BE USED. ANY DIMENSIONS NOT SHOWN SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS. FOR EXACT LOCATIONS, HEIGHT, DOOR SWINGS, MOUNTING HEIGHTS, ETC. REFER TO ARCHITECTURAL DRAWINGS AND DETAILS. F. PRIOR TO STARTING ANY WORK, PURCHASE OF EQUIPMENT, ETC. COORDINATE THE WORK WITH OTHER TRADES. CONFER WITH OTHER CONTRACTORS WHOSE WORK MIGHT AFFECT THIS INSTALLATION AND ARRANGE ALL PARTS OF THIS WORK AND EQUIPMENT OF OTHERS, WITH THE BUILDING CONSTRUCTION AND WITH ARCHITECTURAL FINISH. G. CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR ONE YEAR, EFFECTIVE THE DAY THE PROJECT IS ACCEPTED BY THE OWNER. H. DO ALL NECESSARY CUTTING AND ROUGH PATCHING. FINISH PAINTING, FINISH PATCHING AND POWER WIRING IS BY OTHERS. I. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL MECHANICAL CEILING EQUIPMENT. J. HVAC DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH ASHRAE AND LATEST SMACNA STANDARDS. PROVIDE TURNING VANES IN ALL ELBOWS. DUCTWORK SHALL HAVE A MINIMUM PRESSURE CLASSIFICATION OF 2", SEAL CLASS C, WITH A MAXIMUM LEAKAGE RATE OF 5%. K. PROVIDE A MANUAL BALANCING DAMPER AT ALL SUPPLY AND RETURN BRANCH TAKEOFFS, IN ACCESSIBLE LOCATION OR WITH ACCESS DOOR. L. DUCTWORK DIMENSIONS NOTED ON DRAWINGS ARE EXTERIOR DIMENSIONS AND INCLUDE LINING. M. INSTALL BOTTOM OF HORIZONTAL, EXPOSED DUCTWORK IN SALES AREAS AND STOCK ROOMS UP WITH-IN IN JOIST SPACE TO MAINTAIN MAXIMUM CLEARANCE. N. THE BALANCING CONTRACTOR SHALL BALANCE AIR FLOW QUANTITIES TO WITHIN 5% OF THE DESIGN CONDITIONS LISTED ON PLANS. THIS CONTRACTOR SHALL INCLUDE ONE (1) ADDITIONAL SET OF BELTS AND SHEAVES AND REBALANCING FOR EACH SYSTEM FOR THE PROJECT. ALL OF THE ABOVE WORK SHALL BE AT NO ADDITIONAL COST TO THE OWNER. O. ALL PIPING, DUCTS, VENTS, ETC., EXTENDING THROUGH WALLS AND ROOF SHALL BE FLASHED AND COUNTER-FLASHED IN A WATERPROOF MANNER. P. SPRINKLER CONTRACTOR SHALL COORDINATE INSTALLATION OF SPRINKLER PIPING WITH DUCTWORK, LIGHTS, AND PARTITION LAYOUT. LIGHTS ARE NOT TO BE MOVED, SPRINKLER PIPING SHALL BE ROUTED AROUND LIGHTS AS REQUIRED. {Q. MECHANICAL CONTRACTOR SHALL PERFORM ROUTINE SERVICE INSPECTION OF EXISTING ROOFTOP UNIT TO BE REUSED FOR THIS PROJECT. LUBRICATE BEARINGS, SERVICE CONTROL SYSTEMS, REPLACE FAN BELTS AS REQUIRED,} CLEAN AND COMB EVAPORATOR AND CONDENSER COILS, CLEAN CONDENSATE DRAIN{ AND PAN AND }INSTALL NEW FILTERS AFTER COMPLETION OF CONSTRUCTION{. }ADD REFRIGERANT AS REQUIRED TO MEET MANUFACTURER'S RECOMMENDED OPERATING CHARGE. EQUIPMENT SHALL BE PLACED IN FULL OPERATION WITH CONTROLS CALIBRATED UPON COMPLETION OF PROJECT. SUBMIT A WRITTEN REPORT TO OWNER OF ANY MAJOR COMPONENT FAILURES OR ANTICIPATED COMPONENT FAILURES. REPORT SHALL INCLUDE COST INCLUDING LABOR TO SERVICE ALL ITEMS NOT OTHERWISE LISTED ABOVE. R. CONTRACTORS BIDDING THIS PROJECT SHALL HAVE PRIOR EXPERIENCE WORKING IN THIS JURISDICTION AND MUST LIST ON BID FORM ANY LOCAL REQUIREMENTS THAT ARE NOT SHOWN ON THE DRAWINGS. SUBMISSION OF A BID SHALL BE EVIDENCE THAT THE CONTRACTOR'S BID INCLUDES ALL JURISDICTIONAL REQUIREMENTS. S. THIS CONTRACTOR SHALL COMPLETE ALL DEMOLITION OF EXISTING MECHANICAL SYSTEMS AS INDICATED ON MECHANICAL AND ARCHITECTURAL PLANS OR AS NECESSARY FOR THE PROJECT. REMOVE FROM SITE AND DISPOSE OF ALL MATERIAL AND DEBRIS FROM THIS WORK IN A CODE AND EPA APPROVED MANNER. INPUT MBH Mar 26, 2021 - 17:38:37 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_H2.0.dwg Updated By: rvan mld CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 25001 Emery Road, Suite #200 Warrensville Heights, Ohio 44128 Phone: 216-292-4696 Fax: 216-292-5874 Email: mail@mchenryassociates.com Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 H2.0 H.V.A.C. NOTES AND SCHEDULES {NOTE: SPACE ABOVE CEILINGS IS UTILIZED AS A RETURN AIR PLENUM. ALL MATERIALS ABOVE CEILINGS SHALL BE PLENUM RATED.} 05/11/21