HomeMy WebLinkAboutH2.0ACOUSTIC
ELBOW WITH
VOLUME
MANUAL
TAKE-OFF
TO
TO
45%%127
TAKE-OFF
AIRFOIL
FITTING 30%%127
INCLUDES LINING.
1. DASHED LINE INDICATES 1" INTERIOR
NOTED. DUCT SIZE IS EXTERIOR AND
ACOUSTIC LINING UNLESS OTHERWISE
%%UNOTES:
FLEXIBLE
MAX. LENGTH = 48"
DUCT
BRANCH
DIFFUSER
TO
TRANSITION
MVD
TO
(NOTE #1)
TAKE-OFF
LINED
45%%127
MVD
DOUBLE SINGLE
3
TYPICAL DUCT TAKE-OFF DETAIL
SCALE: NONE
A. SEAL VOID BETWEEN WALL AND ALL DUCT PENETRATIONS AIRTIGHT.
B. ACOUSTIC LINE AIR TRANSFER DUCTS WITH 1/2" ACOUSTIC LINING. DUCT
DIMENSIONS ARE EXTERIOR AND INCLUDE LINING.
C. ALL GRILLES SHALL BE FURNISHED WITH FRAMES COMPATIBLE WITH WALL OR
CEILING CONSTRUCTION
D. REFER TO MECHANICAL FLOOR PLANS FOR MOUNTING HEIGHTS OF ALL WALL
MOUNTED GRILLES.
E. WHEN GRILLE IS ABOVE 10'-0" A.F.F. INSTALL GRILLE SO BLADES ANGLE UP ON
FACE.
F. ALL GRILLES ON SALES FLOOR SHALL BE INSTALLED ABOVE PAINT BREAK LINE
UNLESS INDICATED OTHERWISE ON FLOOR PLAN.
{\LNOTES FOR ALL AIR TRANSFER DUCTS}:
GRILLE
TYP. (2)
%UATD-1 SECTION VIEW
WALL NOTE: INSTALL GRILLE SO BLADES ANGLE UP ON FACE
G-1, WALL DUCT SLEEVE.
AIR TRANSFER DUCT OPENING SHALL MATCH GRILLE SIZE. REFER TO DRAWING H1.0 FOR GRILL SIZES.
%%UATD-1 PLAN VIEW
WALL
GRILLE
TYP. (2)
G-1, WALL
ATD-1
2
AIR TRANSFER DUCT DETAILS
SCALE: NONE
DIFFUSER TYPE
AS NOTED ABOVE
GRILLE, REGISTER, OR
MANUFACTURER
AIR QUANTITY
DIFFUSER 1. DESIGNATIONS ON PLANS AS FOLLOWS:
G-1
MARK
DIFFUSER NECK SIZE OR GRILLE/REGISTER SIZE.
DAMPER
AS NOTED
TITUS
350-RL
AS NOTED SURFACE HORIZ. BAR NA
CFM
& MODEL # SIZE
NECK
TYPE FACE TYPE
FRAME
PATTERN
NO STEEL TRANSFER OFF-WHITE
MATERIAL SERVICE FINISH NOTES
G-1, 12x12
400 CFM
NOTES:
SR-1
300-RL DEFLECTION
AS NOTED
TITUS
AS NOTED SURFACE HORIZ. BAR
DOUBLE
YES STEEL SUPPLY OFF-WHITE
'XR' OR EXISTING TO BE REMOVED
T
GH
CO
S
INDICATED ON FLOOR PLAN AND
DRAWINGS.
CONDUIT PER N.E.C.
EQUIPMENT TAG
UNDERCUT DOOR, REFER TO ARCHITECTURAL
SPECIFICATIONS. ALL WIRING TO BE IN
LOUVERED DOOR, REFER TO ARCHITECTURAL
DRAWINGS. X SQUARE FEET OF FREE AREA.
S ONE INSTALLED (1) HOUR AND TIMER WIRED WALL BY SWITCH. EC. FURNISHED BY MC.
X
X
LD X.XX%%159 F.A.
UC
FD
MD-X
EXISTING, RELOCATED, SHOWN IN
NEW LOCATION
EXISTING TO BE RELOCATED
EXISTING TO BE ABANDONED IN PLACE
AND WIRED BY EC.
THERMOSTAT. FURNISHED BY MC. INSTALLED
INDICATES CODED NOTE
CO-2 SENSOR TO BE FURNISHED BY MC.
INSTALLED AND WIRED BY EC.
NOVAR GLOBAL HUMIDITY SENSOR. REFER TO
ELECTRICAL DWGS FOR DETAILS.
NOVAR INDOOR TEMPERATURE SENSOR.
REFER TO ELECTRICAL DWGS FOR DETAILS.
NOVAR TEMPERATURE SENSOR. REFER TO
ELECTRICAL DWGS FOR DETAILS.
ACCESS DOOR
LOCATED, INSTALLED AND WIRED AS
UNDER ALARM. DETECTOR SHALL BE
DUCT SMOKE DETECTOR TO SHUT DOWN UNIT
'UL' LISTED FIRE DAMPER WITH DUCT
MOTORIZED DAMPER, 120 VOLT
S
'XNL' OR
'XRL' OR
'XA' OR
2
HP HORSE POWER
LOW PRESSURE GAS PIPING
REGULATED 2 PSI GAS PIPING
EXISTING TO REMAIN
FIRE PROTECTION CONTRACTOR
ELECTRICAL CONTRACTOR
MECHANICAL CONTRACTOR
PLUMBING CONTRACTOR
'X' OR
RPG-2#
G
EC
MC
FPC
PC
KILOWATTS
OUTSIDE AIR
LINEAR DIFFUSER
PRESSURE
OPERABLE WEIGHT
ROOF OPENING
RETURN AIR
SUPPLY REGISTER
SUPPLY AIR
ROOFTOP UNIT
STATIC PRESSURE
THOUSAND BTU/HOUR
MANUAL VOLUME DAMPER
UNIT HEATER
THERMOSTAT
GC GENERAL CONTRACTOR
UH
T'STAT
SR
RTU
SA
SP
RO
RA
PRESS.
OP. WT.
OA
MVD
MBH
LD
KW
HTG' HEATING
CEILING DIFFUSER
DIAMETER
CORRIDOR
EXHAUST AIR
DRAWING
EXHAUST
EFFICIENCY
EXHAUST FAN
AIR TRANSFER DUCT
ENERGY EFFICIENCY RATIO
DRUM LOUVER PLENUM DIFFUSER SYSTEM
CABINET UNIT HEATER
CUBIC FEET PER MINUTE
EXTERNAL STATIC PRESSURE
ABOVE FINISHED FLOOR
EXH.
G
E.S.P.
EFF.
GRILLE
EER
EF
EA
DWG
CUH
DIA
DLPD
CORR.
CFM
ATD
CD
AFF
UNDERWRITER'S LABORATORY
TYPICAL
UL
TYP.
TOP OF
DEG DEGREES
B' BOTTOM OF
CONN. CONNECT / CONNECTION
H
LENNOX HUMIDITY SENSOR. REFER TO
ELECTRICAL DWGS FOR DETAILS.
1
HVAC LEGEND
SCALE: NONE
VOLTS
UNIT NO.
FLA MCA MOCP PHASE
LOCATION SERVES UNIT POWER
EXT. SP
O.A.
CFM HP
(IN WC)
CFM
SUPPLY FAN
TOTAL 225
HEATING
NOMINAL
TONS
EER/SEER MBH
COOLING COIL REMARKS
OPEN SALES ROOF
RTU-2XA
RTU-3X OPEN SALES ROOF SALES
RTU-4X OPEN SALES ROOF SALES
RTU-5X
RTU-6X
OPEN SALES ROOF
RTU-7X
OPEN SALES ROOF
RTU-1X OPEN SALES ROOF SALES
3 460
3 460 8,000 5
57 25 470 LGC-300H
3 460
77
3 460
3 460
3 460 30
1, 2, 3
RTU-8X
RTU-9X
OPEN SALES ROOF
OPEN SALES ROOF
SALES
OFFICES
SALES
3 460
3 460
57
57
77
18
77
8,000
8,000
13,000
13,000
13,000
13,000
2,100
25
25
30
30
470
470
470
470
LGC-300H
LGC-300H
LGA-360H
LGA-360H
LGA-060S
LGA-360H
30 LGA-360H
5
77
125
470
470
5
5
10
10
10
10
2
EXISTING
EQUIPMENT
(LENNOX)
REMARKS:
{1. EXISTING ROOFTOP UNITS TO REMAIN.
2. MAINTAIN EXISTING OUTSIDE AIR SETTING.
}3. MAINTAIN EXISTING SMOKE DETECTORS.
4. CONTRACTOR SHALL PERFORM ROUTINE SERVICE INSPECTION OF EXISTING ROOFTOP UNIT TO BE REUSED FOR THIS PROJECT. LUBRICATE
BEARINGS, SERVICE CONTROL SYSTEMS, REPLACE FAN BELTS AS REQUIRED, CLEAN AND COMB EVAPORATOR AND CONDENSER COILS, CLEAN
CONDENSATE DRAIN AND PAN, AND INSTALL NEW FILTERS AFTER COMPLETION OF CONSTRUCTION. ADD REFRIGERANT AS REQUIRED TO MEET
MANUFACTURER'S RECOMMENDED OPERATING CHARGE. EQUIPMENT SHALL BE PLACED IN FULL OPERATION WITH CONTROLS CALIBRATED UPON
COMPLETION OF PROJECT. SUBMIT A WRITTEN REPORT TO OWNER OF ANY MAJOR COMPONENT FAILURES OR ANTICIPATED COMPONENT
FAILURES. REPORT SHALL INCLUDE COST INCLUDING LABOR TO SERVICE ALL ITEMS NOT OTHERWISE LISTED ABOVE.
5. INCLUDE REMARK 4 FOR ROOFTOP UNIT 9X FOR ADD/ALT #8.
1, 2, 3
1, 2, 3, 5
1, 2, 3, 4
1, 2, 3
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
CFM
UNIT NO.
REMARKS:
EF-3X
WATTS
LOCATION SERVES PHASE VOLTS
OR
HP TYPE
EXHAUST FAN SCHEDULE (EXISTING)
TYPE
EXT. BLADE FAN
RPM
DRIVE
(MAKE & MODEL)
DESIGN
EQUIPMENT
STOCK ELEVATOR 115 IN LINE 880
WEIGHT REMARKS
EF-1X ROOF RESTROOMS 115 DOME 750
{1. EXISTING EXHAUST FAN TO REMAIN. MAINTAIN EXISTING CONTROL SEQUENCE.
}
EF-4X ROOF \pxqc;ELECT ROOM 115 DOME 400
EF-5X
SP
ROOF \pxqc;GOLF STOCK 115 DOME 880
EF-2X ROOF JAN. CLOSET 115100 DOME
OPEN SALES ROOF SALES 57 5 460 8,000
5 25 470 LGC-300H
EF-6X STOCKROOM VIDEO 115 IN LINE 400
SALES
SALES
UNIT NO. LOCATION HEATER KW
VOLTS PHASE AMPS
ELECTRICAL
CFM
(MAKE & MODEL)
EQUIPMENT
DESIGN
ARRANGEMENT
MOUNTING REMARKS
CUH-1X STAIR SURFACE, WALL
277 5.0
CUH-2X STAIR SURFACE, WALL
277 5.0 1
CUH-3X STAIR SURFACE, WALL
277 4.8
CUH-4X VESTIBULE SURFACE, WALL
277 4.8
CUH-5X VESTIBULE 277 SURFACE, WALL
4.8
CUH-6X VESTIBULE SURFACE, WALL
277 4.8
CUH-7X VESTIBULE SURFACE, WALL
277 4.8
CUH-8X VESTIBULE SURFACE, WALL
277 4.8 1
REMARKS: {1. EXISTING HEATER TO REMAIN. MAINTAIN EXISTING CONTROL SEQUENCE.
}
HEATER
INPUT
UNIT NO. LOCATION
VOLTS PHASE AMPS
ELECTRICAL
HP
(MAKE & MODEL)
EQUIPMENT
DESIGN REMARKS
UH-1X STOCK 120 100
UH-2X STOCK 120 100 1
REMARKS: {1. EXISTING HEATER TO REMAIN. MAINTAIN EXISTING CONTROL SEQUENCE.
}
H.V.A.C. GENERAL NOTES:
A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING PROCESS AND FIELD VERIFY EXISTING CONDITIONS.
CONTRACTOR SHALL TAKE ALL INTERFERENCES INTO CONSIDERATION. PROVIDE ALL NECESSARY OFFSETS
OR TRANSITIONS WITH EQUIVALENT AREAS TO MATCH DUCT SIZES AS INDICATED ON DRAWINGS.
B. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, DOCUMENTS AND SERVICES
RELATED TO INSTALLATION OF THE WORK.
C. CONTRACTOR IS RESPONSIBLE TO AND SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE LATEST
STATE CODES, TOWNSHIP, AND NFPA, O.S.H.A., AND THE RULES AND REGULATIONS OF ALL CITY, STATE, AND
FEDERAL AUTHORITIES HAVING JURISDICTION. PROVIDE OWNER WITH CERTIFICATES OF INSPECTION.
D. CONTRACTOR SHALL BE LICENSED, TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF
MECHANICAL SYSTEMS, INCLUDING DUCTS, PIPING AND EQUIPMENT. UNCERTIFIED PERSONS MAY PERFORM
MECHANICAL INSTALLATIONS ONLY WHEN UNDER DIRECT SUPERVISION AND RESPONSIBILITY OF A
CERTIFIED INSTALLER OR LICENSED CONTRACTOR. VERIFICATION OF CERTIFICATION AND LICENSES ARE
REQUIRED.
E. THESE DRAWINGS INDICATE THE SIZE AND GENERAL LOCATION OF WORK. SCALED DIMENSIONS SHALL
NOT BE USED. ANY DIMENSIONS NOT SHOWN SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.
FOR EXACT LOCATIONS, HEIGHT, DOOR SWINGS, MOUNTING HEIGHTS, ETC. REFER TO ARCHITECTURAL
DRAWINGS AND DETAILS.
F. PRIOR TO STARTING ANY WORK, PURCHASE OF EQUIPMENT, ETC. COORDINATE THE WORK WITH OTHER
TRADES. CONFER WITH OTHER CONTRACTORS WHOSE WORK MIGHT AFFECT THIS INSTALLATION AND
ARRANGE ALL PARTS OF THIS WORK AND EQUIPMENT OF OTHERS, WITH THE BUILDING CONSTRUCTION AND
WITH ARCHITECTURAL FINISH.
G. CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR ONE YEAR, EFFECTIVE THE DAY THE
PROJECT IS ACCEPTED BY THE OWNER.
H. DO ALL NECESSARY CUTTING AND ROUGH PATCHING. FINISH PAINTING, FINISH PATCHING AND POWER
WIRING IS BY OTHERS.
I. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL MECHANICAL CEILING
EQUIPMENT.
J. HVAC DUCTWORK SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH ASHRAE AND LATEST
SMACNA STANDARDS. PROVIDE TURNING VANES IN ALL ELBOWS. DUCTWORK SHALL HAVE A MINIMUM
PRESSURE CLASSIFICATION OF 2", SEAL CLASS C, WITH A MAXIMUM LEAKAGE RATE OF 5%.
K. PROVIDE A MANUAL BALANCING DAMPER AT ALL SUPPLY AND RETURN BRANCH TAKEOFFS, IN
ACCESSIBLE LOCATION OR WITH ACCESS DOOR.
L. DUCTWORK DIMENSIONS NOTED ON DRAWINGS ARE EXTERIOR DIMENSIONS AND INCLUDE LINING.
M. INSTALL BOTTOM OF HORIZONTAL, EXPOSED DUCTWORK IN SALES AREAS AND STOCK ROOMS UP
WITH-IN IN JOIST SPACE TO MAINTAIN MAXIMUM CLEARANCE.
N. THE BALANCING CONTRACTOR SHALL BALANCE AIR FLOW QUANTITIES TO WITHIN 5% OF THE DESIGN
CONDITIONS LISTED ON PLANS. THIS CONTRACTOR SHALL INCLUDE ONE (1) ADDITIONAL SET OF BELTS AND
SHEAVES AND REBALANCING FOR EACH SYSTEM FOR THE PROJECT. ALL OF THE ABOVE WORK SHALL BE AT
NO ADDITIONAL COST TO THE OWNER.
O. ALL PIPING, DUCTS, VENTS, ETC., EXTENDING THROUGH WALLS AND ROOF SHALL BE FLASHED AND
COUNTER-FLASHED IN A WATERPROOF MANNER.
P. SPRINKLER CONTRACTOR SHALL COORDINATE INSTALLATION OF SPRINKLER PIPING WITH DUCTWORK,
LIGHTS, AND PARTITION LAYOUT. LIGHTS ARE NOT TO BE MOVED, SPRINKLER PIPING SHALL BE ROUTED
AROUND LIGHTS AS REQUIRED.
{Q. MECHANICAL CONTRACTOR SHALL PERFORM ROUTINE SERVICE INSPECTION OF EXISTING ROOFTOP
UNIT TO BE REUSED FOR THIS PROJECT. LUBRICATE BEARINGS, SERVICE CONTROL SYSTEMS, REPLACE FAN
BELTS AS REQUIRED,} CLEAN AND COMB EVAPORATOR AND CONDENSER COILS, CLEAN CONDENSATE DRAIN{
AND PAN AND }INSTALL NEW FILTERS AFTER COMPLETION OF CONSTRUCTION{. }ADD REFRIGERANT AS
REQUIRED TO MEET MANUFACTURER'S RECOMMENDED OPERATING CHARGE. EQUIPMENT SHALL BE
PLACED IN FULL OPERATION WITH CONTROLS CALIBRATED UPON COMPLETION OF PROJECT. SUBMIT A
WRITTEN REPORT TO OWNER OF ANY MAJOR COMPONENT FAILURES OR ANTICIPATED COMPONENT
FAILURES. REPORT SHALL INCLUDE COST INCLUDING LABOR TO SERVICE ALL ITEMS NOT OTHERWISE
LISTED ABOVE.
R. CONTRACTORS BIDDING THIS PROJECT SHALL HAVE PRIOR EXPERIENCE WORKING IN THIS JURISDICTION
AND MUST LIST ON BID FORM ANY LOCAL REQUIREMENTS THAT ARE NOT SHOWN ON THE DRAWINGS.
SUBMISSION OF A BID SHALL BE EVIDENCE THAT THE CONTRACTOR'S BID INCLUDES ALL JURISDICTIONAL
REQUIREMENTS.
S. THIS CONTRACTOR SHALL COMPLETE ALL DEMOLITION OF EXISTING MECHANICAL SYSTEMS AS
INDICATED ON MECHANICAL AND ARCHITECTURAL PLANS OR AS NECESSARY FOR THE PROJECT. REMOVE
FROM SITE AND DISPOSE OF ALL MATERIAL AND DEBRIS FROM THIS WORK IN A CODE AND EPA APPROVED
MANNER.
INPUT
MBH
Mar 26, 2021 - 17:38:37 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_H2.0.dwg Updated By: rvan
mld
CONTRACTOR MUST VERIFY
DIMENSIONS ALL CLEARANCES IN AND FIELD
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
25001 Emery Road, Suite #200
Warrensville Heights, Ohio 44128
Phone: 216-292-4696
Fax: 216-292-5874
Email: mail@mchenryassociates.com
Issued for
Bid-Permit
03-26-21
T F
\pxql;216.520.1551
\pxql;216.520.1567
03-26-21
SM
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
H2.0
H.V.A.C. NOTES AND
SCHEDULES
{NOTE:
SPACE ABOVE CEILINGS IS UTILIZED AS A
RETURN AIR PLENUM. ALL MATERIALS ABOVE
CEILINGS SHALL BE PLENUM RATED.}
05/11/21