Loading...
HomeMy WebLinkAboutHD1.18 A 1 2 3 4 5 6 7 B C D E F A B C D E F G G 4.4 5 1 SCALE: 3/32" = 1'-0" Θ.Θ ΝΕΕΗΒ∆Ρ 1 SCALE: 3/32" = 1'-0" ΝΟ∆Μ ΣΝ Α∆ΚΝς ΝΟ∆Μ ΣΝ Α∆ΚΝς Ρ≅Κ∆Ρ ΦΝΚΕ ΡΣΝΒϑ ΦΝΚΕ ΟΘΝ ΡΓΝΟ Λ≅ΗΜ ΡΣΝΒϑ 'X' 10" 'X' 12" 'X' 18" 'X' 16" 'X' 12" 'X' 14" 'X' 12" 'X' 18x12 'X' 24x24 'X' 34x20 'X' 34x20 'X' 12" 'X' 14" 'X' 12" 'X' 8" 'X' 12" 'X' 14" 'X' 16" 'X' R.A. DUCT 'X' 14" 'XR' DUCT 'X' 12" RTU 'X' ON ROOF 25 TON COOLING 2X 'X' 40x20 'X' R.A. DUCT RTU 'X' ON ROOF 30 TON COOLING 6X EF 'XR' ON ROOF 7X 'XR' ATD 'XRL' ATD 'X' 10" 'X' 12" 'XR' DIFFUSER 1 3 'XRL' ATD 3 'X' DIFFUSER EF 'X' ON ROOF 2X 'X' R.A. DUCT RTU 'X' ON ROOF 30 TON COOLING 5X 'X' 14" 'X' DIFFUSER 'X' 12" EF 'X' ON ROOF 4X 'X' 40x20 'X' R.A. DUCT RTU 'X' ON ROOF 25 TON COOLING ∆Κ∆Υ− ∆Κ∆Υ− 'X' 40x20 'X' R.A. DUCT EF 'X' ON ROOF 5X 'X' ATD 'XR' ATD 2 RTU 'X' ON ROOF 25 TON COOLING 3X 'X' 12" 'X' R.A. DUCT 'X' 12x10 EF 'X' ON ROOF RTU 'X' ON ROOF 5 TON COOLING 9X RTU 'X' ON ROOF 30 TON COOLING 7X 'X' R.A. DUCT RTU 'X' ON ROOF 30 TON COOLING 8X 'X' 40x20 'X' R.A. DUCT RTU 'X' ON ROOF 25 TON COOLING 4X 'X' GRILLE 'X' DIFFUSER 'X' GRILLE 'X' GRILLE 'X' DIFFUSER 'XR' DIFFUSER 1 CAP 1. EXISTING DIFFUSER AND BRANCH DUCTWORK TO BE REMOVED BACK TO SUPPLY DUCT MAIN AND CAPPED AIR TIGHT. {PAINT CAPPED DUCT TO MATCH EXISTING.} { 2. EXISTING AIR TRANSFER DUCT AND GRILLES TO BE REMOVED. 3. EXISTING AIR TRANSFER DUCT AND GRILLES TO BE RELOCATED. REFER TO DRAWING H1.1 FOR NEW LOCATION. }4. EXISTING EXHAUST FAN AND DUCTWORK TO BE REMOVED. MAINTAIN EXISTING ROOF CURB. INSTALL REINFORCED SHEET METAL CAP OVER EXISTING ROOF OPENING, PACK CURB WITH BATT INSULATION AND PROVIDE STRUCTURALLY REINFORCED GALVANIZED STEEL, INSULATED, WEATHER TIGHT CURB CAP. BREAK TOP OF CURB CAP FOR 100% DRAINAGE. {5. EXISTING EXHAUST AIR GRILLE AND SUPPLY DIFFUSER TO BE RELOCATED. REFER TO DRAWING H1.1 FOR NEW LOCATIONS.} H.V.A.C. CODED NOTES: 'X' SUPPLY REGISTER TYP. 'X' RETURN GRILLE TYP. 'X' SUPPLY DIFFUSER TYP. 2 'X' SUPPLY AIR DUCT DROP DOWN TO 1ST FLOOR 'X' SUPPLY AIR DUCT DROP DOWN TO 1ST FLOOR 'X' SUPPLY AIR DUCT DROP DOWN TO 1ST FLOOR 'X' SUPPLY AIR DUCT DROP DOWN TO 1ST FLOOR NO H.V.A.C. WORK IN HATCHED AREA. 4 Θ.Θ EF 'X' ON ROOF 'XRL' GRILLE 'XRL' DIFFUSER 'XRL' GRILLE 'XRL' GRILLE 5 5 5 5 'XRL' 5 DIFFUSER SCALE: 3/32" = 1'-0" H.V.A.C ADD/ALT #8 SCALE: 3/32" = 1'-0" Mar 16, 2021 - 17:29:27 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_Setup.dwg Updated By: rvan mld CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 HD1.1 UPPER LEVEL H.V.A.C. DEMO PLAN 05/11/21