FP1
FIRST FLOOR LIFE SAFETY PLAN SCALE
3/32" = 1' - 0"
3.
FIRE EXTINGUISHER NOTES
INFORMATION BASED ON INTERNATIONAL FIRE CODE REQUIREMENTS
AND NFPA 10 FOR AN ORDINARY (MODERATE HAZARD) OCCUPANCY
2.
1. LOCATIONS AND QUANTITIES AS PROPOSED ARE BASED
ON NFPA 10. VERIFY & COORDINATE FINAL QUANTITIES,
LOCATIONS, AND INSTALLATION WITH LOCAL
JURISDICTION.
TOTAL FIRE EXTINGUISHERS TO BE DETERMINED BY THE
FIRE MARSHALL. ALL FIRE EXTINGUISHERS SHALL HAVE A
GROSS WEIGHT NOT TO EXCEED 40 lbs. AND ARE TO BE
MOUNTED ON MOUNTING BRACKETS SO THAT TOP OF
UNIT IS NO MORE THAN 5'-0" A.F.F.
PLACE SALES FLOOR F.E.'s ON REAR SIDE OF COLUMNS AS
SHOWN (or as allowed by fixture placement per DSG's F-1 plan.
11,250 S.F. MAX. Floor area for each fire extinguisher.
75' MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER
1,500 SQ. FT. PER UNIT OF A
Minimum rated extinguisher - 2a-10b:c
FIRE EXTINGUISHER SIZE AND PLACEMENT FOR CLASS A
HAZARDS.
FIRE EXTINGUISHER SIZE AND PLACEMENT FOR CLASS B
HAZARDS.
ORDINARY (MODERATE) HAZARD - Size 10b extinguisher
rating requires 30'-0" max. travel distance to extinguisher.
Size 20B Extinguisher rating requires 50'-0" max. travel distance
to extinguisher.
FIRE EXTINGUISHER SIZE AND PLACEMENT FOR CLASS C HAZARDS.
Required where energized electrical equipment can be
encountered that would require a nonconducting extinguishing
medium.
FIRE EXTINGUISHERS
VI. Exit Capacity:
A. Minimum number of exits: (Table 1021.4)
First Floor Total Occupant Load = 533 occupants = 3 exits, min.
Second Floor Total Occupant Load = 456 occupants = 2 exits, min.
B. Number of exits provided: First Floor = 6
Second Floor = 2
C. Minimum exit width required (Table 1005.1):
D. Exit width provided:
1. Stairways: 2 stairs = 68" provided
2. First floor doors: 552" of egress width provided
3. Second floor doors: 68" of egress width provided
VII. Arrangement of Exits:
A. Separation of Exits: At least 2 exits shall be placed a distance apart equal
to not less than half the length of the maximum overall diagonal dimension
of the area being served . One third the length for sprinklered buildings.
B. Maximum travel distance: 250 feet.
VIII. Other life safety considerations:
1. Doors: 0.15 inches per person (w/ Sprinkler System)
1st floor - 534 occupants x 0.15 = 80.0" of required door width
2nd floor - 456 occupants x 0.15 = 68.4" of required door width
2. Stairs: 0.20 inches per person
2nd floor - 456 occupants x 0.20 = 91.2" of required width
A. Minimum corridor width: 44" .
B. Dead end corridor: 20' maximum. Exception #2. 50' maximum in Group M
where building is equipped throughout with an automatic sprinkler system.
C. Door clear width: 32" minimum.
4. Floor Finishes - Class II - Floor finish materials must
comply with DOC FF-1 'pill test' (804.4.1).
3. Rooms/ Enclosed Spaces: Class C
2. Exit Access Cooridors - Class C
1. Vertical Exits/ Passageways - Class B
D. Interior finishes (Table 803.9):
Total Occupants: 989 / 2 = 495 Men & 495 Women
a. 1 required, 1 existing
4. Service sinks:
a. 2 total required (1 for each 1000 occupants), 2 existing - (1) dual height hi/low
fixture + (1) single drinking fountain.
3. Drinking fountains:
b. 1 lavatories required; (3 existing)
a. 2 toilets required; (6 existing)
2. Female:
b. 1 lavatories required; (2 existing)
1. Male: a. 2 toilets required; (2 existing)
B. Minimum fixtures required:
A. Occupant load:
Note Section 1005.1: 50% x 80.0"=40.0" for remaining exits if main
exit (largest capacity) is blocked 150 + 150 = 300"
(remaining doors must add up to a minimum 50% of egress width
capacity as required by code.)
IX. Plumbing Fixture analysis:
b. 1 urinal required; (1 existing)
NOTE:
EXISTING FIRE EXTINGUISHERS TO REMAIN IN EXISTING LOCATIONS, UNLESS REQUIRED
TO BE RELOCATED FOR NEW FIXTURES OR PARTITIONS. GC TO COORDINATE WITH NEW
WORK AND RELOCATE OR PROVIDE SUPPLEMENTAL EXTINGUISHERS AS REQUIRED. GC
SHALL COORDINATE WITH THE FIRE MARSHAL AND LOCAL BUILDING OFFICIALS.
PLAN REVIEW DATA SCALE 2
N.T.S.
I. Code Data:
II. Occupancy Group:
A. Mercantile (M)
B. Storage (S-1) Section 311
C. Business (B) Section 304
III. Construction Type:
IV. Fire Suppression System:
A. Fully sprinklered (903.2.7)
B. Manual Fire alarm system not required for Group M occupancies (907.2.7) less than
500 occupants above grade exit discharge or where building is equipped throughout with
an automatic sprinkler system installed in accordance with Section 903.3.1.1
A. 2014 Indiana Building Code
B. 2012 Indiana Plumbing Code
C. 2014 Indiana Mechanical Code
D. 2014 Indiana Fire Code
E. 2014 Indiana Fuel Gas Code
F. Indiana Energy Conservation Code
G. 2010 ADA Standards
SECTION 1003 - GENERAL MEANS OF EGRESS
A. First Floor:
(REFER TO TABLE 1004.1.1 for maximum floor area allowances per occupant.)
Sales floor = 60 s.f. GROSS/OCCUPANT
Storage/receiving = 300 s.f. GROSS/OCCUPANT
Office area= 100 s.f. GROSS/OCCUPANT
( 30,745 s.f. ) = 512 OCCUPANTS
( 5,379 s.f. ) = 18 OCCUPANTS
( 345 s.f. ) = 3 OCCUPANTS
36,469 TOTAL s.f. 533 OCCUPANTS TOTAL
V. Occupant Load (Table 1004.1.1)
SECTION 1003 - GENERAL MEANS OF EGRESS
B. Second Floor:
(REFER TO TABLE 1004.1.1 for maximum floor area allowances per occupant.)
Sales floor = 60 s.f. GROSS/OCCUPANT
Storage/receiving = 300 s.f. GROSS/OCCUPANT
Office area= 100 s.f. GROSS/OCCUPANT
Total (First and Second floor) Occupants = 989
( 25,531 s.f. ) = 426 OCCUPANTS
( 4,185 s.f. ) = 14 OCCUPANTS
( 1,512 s.f. ) = 16 OCCUPANTS
31,288 TOTAL s.f. 456 OCCUPANTS TOTAL
1 2 3 4 5 6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
G G
4.4 5
4x1
4x1 4x1
4x1
4x1
4x1
4x1
ACCESSORY
WALL
DSG-NK-EWP12
SOCKS
4x2
4x1
4x1 4x1
4x1
4x2 4x2 4x2
4x1
4x1 4x1
4x1
4x2 4x2 4x2
4x1
4x1
4x2 4x2 4x2
4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1
4x1 4x1
ACCESSORY
TOWER
ACCESSORY
FIXTURE
TRAINING TABLE
TRAINING BENCH
RUNNING EQUIP.
COUNTER
ALL-IN-ONE PC
48x48 PLATFORM
48x48 PLATFORM
FUSION
FUSION
NIKE
PEDESTAL
NIKE
PEDESTAL
NIKE
PEDESTAL
TRAINING TABLE
TRAINING BENCH
NIKE
PEDESTAL
NIKE
PEDESTAL
48x48 PLATFORM
FUSION
FUSION
NIKE
PEDESTAL
NIKE
PEDESTAL
NIKE
PEDESTAL
FOOTWEAR
BENCH
NIKE
PEDESTAL
NIKE
48x48 PLATFORM PEDESTAL
FOOTWEAR
BENCH
48x48 PLATFORM
NIKE SOCK
FIXTURE
24"
PEDESTAL
24"
PEDESTAL
18"
PEDESTAL
18"
PEDESTAL
TREADMILL WALL
DISPLAY
ACCESSORY
TOWER
48" PEDESTAL
36" x 18"
PEDESTAL
48" PEDESTAL
36" x 18"
PEDESTAL
18"
PEDESTAL
18"
PEDESTAL
FOOTWEAR
BENCH
FOOTWEAR
BENCH
24"
PEDESTAL
24"
PEDESTAL
ACCESSORY
FIXTURE
TIERED
BLEACHER TABLE
TIERED
BLEACHER TABLE
ACCESSORY
TOWER
24"
PEDESTAL
24"
PEDESTAL
ACCESSORY
FIXTURE
FOOTWEAR
BENCH
3 SECTION
GONDOLA
SHOE END CAP
ACC END CAP
3 SECTION
GONDOLA
SHOE END CAP
ACC END CAP
3 SECTION
GONDOLA
SHOE END CAP
ACC END CAP
3 SECTION
GONDOLA
SHOE END CAP
ACC END CAP
3 SECTION
GONDOLA
SHOE END CAP
ACC END CAP
3 SECTION
GONDOLA
SHOE END CAP
ACC END CAP
TREADMILL
48x48 PLATFORM
ACCESSORY
FIXTURE
24"
PEDESTAL
24"
PEDESTAL
48x48 PLATFORM
B 1A
G 1A
B 1A
FOOTWEAR
BENCH
4x1
4x1
4x1
4x1
4x1
4x1 4x1
4x1
4x1
4x1
4x2 4x2 4x2
48" PEDESTAL
36" x 18"
PEDESTAL
48" PEDESTAL
36" x 18"
PEDESTAL
24"
PEDESTAL
24"
PEDESTAL
18"
PEDESTAL
18"
PEDESTAL
24"
PEDESTAL
24"
PEDESTAL
DSG
4x8
DSG
4x8
TABLE
DSG-NT52G-NF
TABLE
DSG-NT52G-NF
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
36/120/19
P
36/120/19
P
4x1 4x1 4x1 4x1 3x1 3x1 3x1
3x1 3x1 4x1 4x1 3x1
18 x 48
3x1
3x1
3x1
3x1
3x1 3x1
3x1
3x2
4x1 4x1
4x1 4x1
4x2
4x1 4x1 4x1
4x1 4x1
4x1 4x1 4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x1
4x2 4x2
4x2 4x2
4x2 4x2
4x1
4x1 4x1
4x1 4x1 4x1 4x1 4x1 4x1 4x1 4x1
GRAPHIC BY NIKE
GRAPHIC BY NIKE
GRAPHIC BY NIKE
SOCKS
BRAILLE
ELEVATOR
36/120/19
P
GR-143
ELEVATOR
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
36/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
36/120/19
P
48/120/19
P
36/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
36/120/19
P
36/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
36/120/19
P
36/120/19
P
36/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222 LF-222
LF-201
LF-201
60/
19 19
60/
19-19
60/
60/
19 19
60/
19-19
60/
60/
19 19
60/
19-19
60/
LF-222
4x1 4x1 4x1
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
60/
19 19
60/
19-19
60/
48/120/19
P
4x1 4x1 4x1
4x1 4x1 4x1
4x2 4x2 3x2
4x1 4x1
4x1 4x1
3x2
4x1
4x1
3x1
3x1
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
36/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
48/120/19
P
36/120/19
P
LF-222
LF-222
LF-222 LF-222
LF-201
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222
LF-222
2
49" TV
LF-201
4WY16-G
SR48A-NF
DSG
36/120/19
P
EXIT #2
150" EGRESS
WIDTH
EXIT #1
150" EGRESS
WIDTH
EXIT #3
150" EGRESS
WIDTH
EXIT #4
34" EGRESS
WIDTH
EXIT #5
34" EGRESS
WIDTH
EXIT #6
34" EGRESS
WIDTH
150'-0" TRAVEL DISTANCE 150'-1" TRAVEL DISTANCE
113'-8" TRAVEL DISTANCE
263'-1
1
2
"
OVERALL DISTANCE OF DIAGONAL
MAXIMUM TRAVELDISTANCE =150'-9
1
2
"
(GREATER THAN
1
3
OF DIAGONAL DISTANCE)
Note: Mixed Occupancies for the purpose
of later defined Non-Seperated Uses
Allowing No Rated Separation of Stock
Rooms. (508.3)
A. II-B (Table 601)
B. Fire Resistance Requirements
C. As Listed:
Fire Resistance rating reqt's for Exterior
walls based on fire separation distance:
Less than 5'
Greater than 5' less than 10'
Greater than 10' , less than 30'
Table 705.8: Max. area of exterior wall openings
Unlimited with separation greater than 30'.
Greater than 25' - Unlimited
Greater than 20' - Unlimited
Greater than 15' - 75%
Greater than 10' - 45%
Greater than 5' - 25%
Greater than 3' - 15%
Required Provided
1. Exterior bearing walls reqt's. below
2. Exterior non-bearing walls
3. Interior bearing walls
4. Combustible materials
5. Structural frame
6. Floors
7. Roofs
8. Shaft enclosures (708.2) 0 hour
0 hour
0 hour
0 hour
allowed
0 hour
reqt's. below
0 HOUR
0 HOUR
0 HOUR
FRT WD. USED
N/A
0 HOUR
0 HOUR
0 HOUR
Greater than 30'
Less than 3' - NOT PERMITTED
LS1.0
FIRST FLOOR
LIFE SAFETY PLAN
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
Issued for
Bid-Permit
03-26-21
TWK
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
1
1
1
1
05-10-21 1 Bulletin 1
05/11/21