HomeMy WebLinkAboutA2.4NOTE:
FOR LOZIER PRODUCTS, GC
NEEDS TO ADD 3" TO
DIMENSIONS PER RUN
(1-1/2" EA. END) TO
ACCOUNT FOR LAST UPRITE.
COORDINATE DIMENSIONS
WITH VENDOR #1
9'-91
2"
GYP. BD. ABOVE BLOCKING
1'-13
4"
METAL STUDS
TO PROVIDE 2"X4"
CONT. WOOD BLK'G
SURFACE MOUNTED
TO STUDS
4'-13
4"
7'-13
4"
9'-73
4"
G.C. TO PROVIDE
2"X4" CONT. WOOD
BLK'G SURFACE
MOUNTED TO STUDS
A
BLK'G DETAIL
LOZIER
SCALE
NTS E
BLK'G DETAIL
PLYWOOD
SCALE
NTS
G.C. TO PROVIDE
CONTINUOUS 5/8"
PLYWOOD BLOCKING
MOUNTED OVER STUDS
UP TO 10'-8" U.N.O. IN
ELEVATIONS
10'-8"
U.N.O.
F
BLK'G DETAIL
PLYWOOD
SCALE
NTS
G.C. TO PROVIDE
CONTINUOUS 5/8"
PLYWOOD BLOCKING
MOUNTED BETWEEN
STUDS UP TO 10'-0" U.N.O.
IN ELEVATIONS
10'-0"
U.N.O.
** NOTE:
PROVIDE BLOCKING SPANNING BETWEEN AT LEAST
2 STUD CAVITIES BEHIND PILASTER LOCATIONS.
T
BLK'G DETAIL
FITTING ROOM BENCH
SCALE
NTS
1'-5"
G.C. TO PROVIDE
2"x6" WD BLOCKING
BETWEEN WALL
STUDS TYP.
INTERIOR OF
FITTING ROOMS
Y
BLK'G DETAIL
FITTING ROOM HOOKS
SCALE
NTS Z
BLK'G DETAIL
FITTING ROOM MIRROR
SCALE
NTS
G.C. TO PROVIDE
2"x6" WD BLOCKING
BETWEEN WALL
STUDS TYP.
5'-8"
4'-0"
G.C. TO PROVIDE
2"x6" WD BLOCKING
BETWEEN WALL
STUDS TYP.
5'-9"
1'-3"
1'-13
4"
METAL STUDS
TO PROVIDE 2"X4"
CONT. WOOD BLK'G
SURFACE MOUNTED
TO STUDS
4'-13
4"
7'-13
4"
9'-73
4"
G.C. TO PROVIDE 2"X4"
CONT. WOOD BLK'G
SURFACE MOUNTED TO
EXISTING GYP. BD.
B
BLOCKING DETAIL
LOZIER
SCALE
NTS
NOTE:
FOR LOZIER PRODUCTS, GC
NEEDS TO ADD 3" TO
DIMENSIONS PER RUN
(1-1/2" EA. END) TO
ACCOUNT FOR LAST UPRITE.
COORDINATE DIMENSIONS
WITH VENDOR #1
NOTE:
GC TO PROVIDE 5/8" GYP.
BOARD OVER PLYWOOD
(PAINT AS SCHEDULED)
F1
BLK'G DETAIL
PLYWOOD-SIMULATOR
SCALE
NTS
G.C. TO PROVIDE
CONTINUOUS 3/4"
PLYWOOD BLOCKING
MOUNTED BETWEEN
STUDS UP TO 11'-0"
11'-0"
8'-31
2"
PROVIDE
2x6 WD BLOCKING
BETWEEN WALL
STUDS TYP.
7'-0"
***LOCATION OF BLOCKING M MUST COORDINATE
WITH LOCATION OF TV - REFER TO F-1 PLAN***
M
BLK'G DETAIL
WALL MOUNTED TV
SCALE
NTS
MELAMINE
OVER GYP. BD.
A3
BLK'G DETAIL
LOZIER - 7'
SCALE
NTS
1'-13
4"
G.C. TO PROVIDE
2"X4" CONTINUOUS
WOOD BLOCKING
SURFACE
MOUNTED TO
STUDS
3'-103
4"
6'-73
4"
6'-91
2"
GYP. BD. ABOVE BLOCKING
TYPE A3
NOTE:
FOR LOZIER PRODUCTS, GC
NEEDS TO ADD 3" TO
DIMENSIONS PER RUN
(1-1/2" EA. END) TO
ACCOUNT FOR LAST UPRITE.
COORDINATE DIMENSIONS
WITH VENDOR #1
G.C. TO PROVIDE
2"X4" CONTINUOUS
WOOD BLOCKING
SURFACE MOUNTED
TO GYP. BD.
1'-13
4"
3'-103
4"
6'-73
4"
6'-91
2"
GYP. BD. ABOVE BLOCKING
B3
BLK'G DETAIL
LOZIER - 7'
SCALE
NTS
NOTE:
FOR LOZIER PRODUCTS, GC
NEEDS TO ADD 3" TO
DIMENSIONS PER RUN
(1-1/2" EA. END) TO
ACCOUNT FOR LAST UPRITE.
COORDINATE DIMENSIONS
WITH VENDOR #1
11'-0"
G.C. TO PROVIDE 2x6
WD BLOCKING
BETWEEN WALL
STUDS TYP.
G1
BLK'G DETAIL
SIMULATOR WALL
SCALE
NTS
FOR ALTERNATE
REFER TO SHEET A12.14a
FOR COORDINATION
FOR ALTERNATE
REFER TO SHEET A12.14a
FOR COORDINATION
A2.4
BLOCKING DETAILS
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
Issued for
Bid-Permit
03-26-21
TWK
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
05/11/21