HomeMy WebLinkAboutA2.4NOTE: FOR LOZIER PRODUCTS, GC NEEDS TO ADD 3" TO DIMENSIONS PER RUN (1-1/2" EA. END) TO ACCOUNT FOR LAST UPRITE. COORDINATE DIMENSIONS WITH VENDOR #1 9'-91 2" GYP. BD. ABOVE BLOCKING 1'-13 4" METAL STUDS TO PROVIDE 2"X4" CONT. WOOD BLK'G SURFACE MOUNTED TO STUDS 4'-13 4" 7'-13 4" 9'-73 4" G.C. TO PROVIDE 2"X4" CONT. WOOD BLK'G SURFACE MOUNTED TO STUDS A BLK'G DETAIL LOZIER SCALE NTS E BLK'G DETAIL PLYWOOD SCALE NTS G.C. TO PROVIDE CONTINUOUS 5/8" PLYWOOD BLOCKING MOUNTED OVER STUDS UP TO 10'-8" U.N.O. IN ELEVATIONS 10'-8" U.N.O. F BLK'G DETAIL PLYWOOD SCALE NTS G.C. TO PROVIDE CONTINUOUS 5/8" PLYWOOD BLOCKING MOUNTED BETWEEN STUDS UP TO 10'-0" U.N.O. IN ELEVATIONS 10'-0" U.N.O. ** NOTE: PROVIDE BLOCKING SPANNING BETWEEN AT LEAST 2 STUD CAVITIES BEHIND PILASTER LOCATIONS. T BLK'G DETAIL FITTING ROOM BENCH SCALE NTS 1'-5" G.C. TO PROVIDE 2"x6" WD BLOCKING BETWEEN WALL STUDS TYP. INTERIOR OF FITTING ROOMS Y BLK'G DETAIL FITTING ROOM HOOKS SCALE NTS Z BLK'G DETAIL FITTING ROOM MIRROR SCALE NTS G.C. TO PROVIDE 2"x6" WD BLOCKING BETWEEN WALL STUDS TYP. 5'-8" 4'-0" G.C. TO PROVIDE 2"x6" WD BLOCKING BETWEEN WALL STUDS TYP. 5'-9" 1'-3" 1'-13 4" METAL STUDS TO PROVIDE 2"X4" CONT. WOOD BLK'G SURFACE MOUNTED TO STUDS 4'-13 4" 7'-13 4" 9'-73 4" G.C. TO PROVIDE 2"X4" CONT. WOOD BLK'G SURFACE MOUNTED TO EXISTING GYP. BD. B BLOCKING DETAIL LOZIER SCALE NTS NOTE: FOR LOZIER PRODUCTS, GC NEEDS TO ADD 3" TO DIMENSIONS PER RUN (1-1/2" EA. END) TO ACCOUNT FOR LAST UPRITE. COORDINATE DIMENSIONS WITH VENDOR #1 NOTE: GC TO PROVIDE 5/8" GYP. BOARD OVER PLYWOOD (PAINT AS SCHEDULED) F1 BLK'G DETAIL PLYWOOD-SIMULATOR SCALE NTS G.C. TO PROVIDE CONTINUOUS 3/4" PLYWOOD BLOCKING MOUNTED BETWEEN STUDS UP TO 11'-0" 11'-0" 8'-31 2" PROVIDE 2x6 WD BLOCKING BETWEEN WALL STUDS TYP. 7'-0" ***LOCATION OF BLOCKING M MUST COORDINATE WITH LOCATION OF TV - REFER TO F-1 PLAN*** M BLK'G DETAIL WALL MOUNTED TV SCALE NTS MELAMINE OVER GYP. BD. A3 BLK'G DETAIL LOZIER - 7' SCALE NTS 1'-13 4" G.C. TO PROVIDE 2"X4" CONTINUOUS WOOD BLOCKING SURFACE MOUNTED TO STUDS 3'-103 4" 6'-73 4" 6'-91 2" GYP. BD. ABOVE BLOCKING TYPE A3 NOTE: FOR LOZIER PRODUCTS, GC NEEDS TO ADD 3" TO DIMENSIONS PER RUN (1-1/2" EA. END) TO ACCOUNT FOR LAST UPRITE. COORDINATE DIMENSIONS WITH VENDOR #1 G.C. TO PROVIDE 2"X4" CONTINUOUS WOOD BLOCKING SURFACE MOUNTED TO GYP. BD. 1'-13 4" 3'-103 4" 6'-73 4" 6'-91 2" GYP. BD. ABOVE BLOCKING B3 BLK'G DETAIL LOZIER - 7' SCALE NTS NOTE: FOR LOZIER PRODUCTS, GC NEEDS TO ADD 3" TO DIMENSIONS PER RUN (1-1/2" EA. END) TO ACCOUNT FOR LAST UPRITE. COORDINATE DIMENSIONS WITH VENDOR #1 11'-0" G.C. TO PROVIDE 2x6 WD BLOCKING BETWEEN WALL STUDS TYP. G1 BLK'G DETAIL SIMULATOR WALL SCALE NTS FOR ALTERNATE REFER TO SHEET A12.14a FOR COORDINATION FOR ALTERNATE REFER TO SHEET A12.14a FOR COORDINATION A2.4 BLOCKING DETAILS Drawn By: Project No.: Date Issue SPORTING GOODS CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 Issued for Bid-Permit 03-26-21 TWK C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 05/11/21