Loading...
HomeMy WebLinkAboutA3.0N FIRST FLOOR REFLECTED CEILING PLAN SCALE FP1 3/32" = 1' - 0" 1 2 3 4 5 6 7 8 A B C D E F A B C D E F G G 4.4 5 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E R R R R R R 49" TV SYMBOL LEGEND SCALE _ NO SCALE NEW 2'-0" x 2'-0" LED FIXTURE (ACT) 2'-0" x 2'-0" SUSPENDED ACOUSTICAL CEILING TILE (REFER TO PLAN FOR HEIGHTS) GENERAL NOTES: 1. ALL SPRINKLER LINES THROUGHOUT ENTIRE STORE SHALL BE AS HIGH AS POSSIBLE, AND COMPLYING WITH LIFE SAFETY CODES - COORDINATE ROUTING WITH HVAC. 2. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. 3. G.C. TO COORDINATE ALL LOCATIONS OF HVAC DIFFUSERS, GRILLES, ETC. SO AS TO AVOID LIGHTING FIXTURE LOCATIONS. 4. PAINT ALL EXPOSED CEILING AREAS IN A FLAT FINISH. ALL EXPOSED DUCTWORK, WIRING, CABLES, ELECTRICAL BOXES, ETC., IN THESE AREAS PAINTED TO MATCH ADJACENT SURFACES. 5. PAINT ALL WALL INTERIOR LOUVERS TO MATCH ADJACENT WALL COLOR. (ACT) 2'-0" x 4'-0" SUSPENDED ACOUSTICAL CEILING TILE (REFER TO PLAN FOR HEIGHTS) SURFACE MOUNTED EXIT SIGN (REFER TO ELECTRICAL) EXISTING RECESSED DOWNLIGHT (REFER TO ELECTRICAL) 5/8" GYPSUM BOARD CEILING PAINTED P-10 UNLESS OTHERWISE NOTED (REFER TO PLAN FOR HEIGHTS) PENDANT MOUNTED EXIT SIGN (REFER TO ELECTRICAL) --- xxx xxx CEILING HEIGHT CEILING SURFACE CEILING FINISH or LOCATION 1' x 4' SURFACE MOUNTED WRAP AROUND FIXTURE (REFER TO ELECTRICAL) EXISTING 2'-0" x 4'-0" FLUORESCENT FIXTURE TO REMAIN EXISTING HI-BAY LIGHT FIXTURE TO REMAIN NEW 2'-0" x 4'-0" LED FIXTURE EXISTING HI-BAY LIGHT FIXTURE TO BE RELOCATED R NEW LED STRIP FIXTURE, REFER TO ELECTRICAL DRAWINGS GENERAL CEILING PLAN NOTES SCALE _ NO SCALE (ACT) ACOUSTICAL CEILING TILE INFILL, MATCH EXISTING SIZE AND TYPE OF CEILING TRACK LIGHTS AT DISPLAY WINDOWS (REFER TO ELECTRICAL) EXISTING 2'-0" x 2'-0" LED FIXTURE NOTE: REMOVE EXISTING TRACK HEADS AND REPLACE WITH NEW PROTOTYPICAL LED TRACK HEADS. QUANTITY AND LOCATIONS AS INDICATED ON THIS DRAWING. RE-USE EXISTING LENGTH OF TRACK WHERE POSSIBLE. SUPPLEMENT WITH NEW TRACK AS REQUIRED TO ALIGN WITH THE FINAL LIGHTING LAYOUT SHOWN ON THIS DRAWING. NOTE: ALL EXISTING LIGHTS TO REMAIN UNLESS OTHERWISE NOTED NOTE: DSG TO CONFIRM NEW TV LOCATIONS AND QUANTITIES AT 3 CASHWRAP AREAS DECORATIVE PENDANT; BOTTOM MOUNTED AT 8'-2" AFF 10'-0" ACT -- EXIST. DECK EXPOSED TV POLE MOUNTED; B.O. @ 8'-6" AFF RELOCATED TRACK AND TRACK HEADS TO MATCH EXISTING SPACING AND DISTANCE FROM WALL, TYP. THROUGHOUT PERIMETER OF STORE 6'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. SINGLE PANEL ILLUMINATED MIRRORS; SEE ELEC DWGS & COORDINATE INSTALLATION WITH VENDOR #1. -- GYP. BD. PAINT (P-163) PAINT ALL SIDES OF ESCALATOR TRACK LIGHTS AT GYP. BD. & CEILING (P-164) DISPLAY GRAPHICS, REFER TO ELECTRICAL DECORATIVE PENDANT LIGHTS, BOTTOM MOUNTED AT 8'-2" AFF, HUNG FROM UNISTRUT TIGHT TO PORTAL STRUCTURE ABOVE 10'-0" GYP. BD. BULKHEAD P-10 NO CEILING - OPEN TO ABOVE 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. -- EXIST. DECK EXPOSED -- EXIST. DECK EXPOSED NO CEILING - OPEN TO ABOVE DECORATIVE PENDANT LIGHTS, BOTTOM MOUNTED AT 8'-2" AFF, HUNG FROM UNISTRUT TIGHT TO PORTAL STRUCTURE ABOVE EQ 10'-0" 10'-0" EQ EQ EQ TV POLE MOUNTED; B.O. @ 8'-6" AFF TV POLE MOUNTED; B.O. @ 8'-6" AFF TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL 3'-31 2" 9'-0" 6'-2 1 2" 6'-6" 5'-2 1 2" 6'-11 1 2" 8'-0" ACT PAINT METAL DECK TO MATCH ADJACENT DECK COLOR AT FORMER ROOM LOCATION 7'-0" TYP. 7'-0" TYP. -- GYP. BD. PAINT (P-163) PAINT ALL SIDES OF ESCALATOR GYP. BD. & CEILING (P-164) 3-EXISTING ARCHED CANOPY & LIGHTS TO REMAIN 3-EXISTING ARCHED CANOPY & LIGHTS TO REMAIN EXISTING HI-BAY LIGHTS TO REMAIN, TYP. U.N.O. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 8'-0" TYP. EXISTING DECORATIVE PENDANT LIGHTS TO REMAIN IN VESTIBULE EXISTING DECORATIVE PENDANT LIGHTS TO REMAIN IN VESTIBULE EXISTING DECORATIVE PENDANT LIGHTS TO REMAIN IN VESTIBULE 1-SINGLE PANEL ILLUMINATED MIRROR IN EACH FIT. RM; SEE ELEC DWGS & COORDINATE INSTALLATION WITH VENDOR #1. -- EXIST. DECK EXPOSED PAINT METAL DECK TO MATCH ADJACENT DECK COLOR AT FORMER ROOM LOCATION PAINT METAL DECK TO MATCH ADJACENT DECK COLOR AT FORMER ROOM LOCATION (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) EXISTING TRACK WITH NEW LED TRACK LIGHTS; MOUNT TO MATCH EXISTING HEIGHTS (REFER TO ELECTRICAL FOR LIGHTING TYPES) DECORATIVE PENDANT LIGHT FIXTURE (REFER TO ELECTRICAL) MOUNTED AT 8'-2" A.F.F. NEW OR RELOCATED TRACK W/ NEW LED TRACK LIGHTS; MOUNT TO MATCH EXISTING HEIGHTS (REFER TO ELECTRICAL FOR LIGHTING TYPES) NEW TRACK & HEADS, TYP. AT ALL PORTALS & FITTING ROOMS NEW EXIT SIGN, SEE ELEC NEW EXIT SIGN, SEE ELEC NEW LAMINATE BEAMS IN BOTH FITTING ROOMS, TYP. REFER TO INTERIOR ELEVATIONS NEW LAMINATE BEAMS IN BOTH FITTING ROOMS, TYP. REFER TO INTERIOR ELEVATIONS 3-EXISTING ARCHED CANOPY & LIGHTS TO REMAIN A3.0 FIRST FLOOR RCP Drawn By: Project No.: Date Issue SPORTING GOODS CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 Issued for Bid-Permit 03-26-21 TWK C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 05/11/21