Loading...
HomeMy WebLinkAboutA3.1N SECOND FLOOR REFLECTED CEILING PLAN SCALE FP1 3/32" = 1' - 0" 8 A 1 2 3 4 5 6 7 B C D E F A B C D E F G G 4.4 5 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E R E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E R R R R R R E E E SYMBOL LEGEND SCALE _ NO SCALE NEW 2'-0" x 2'-0" LED FIXTURE (ACT) 2'-0" x 2'-0" SUSPENDED ACOUSTICAL CEILING TILE (REFER TO PLAN FOR HEIGHTS) GENERAL NOTES: 1. ALL SPRINKLER LINES THROUGHOUT ENTIRE STORE SHALL BE AS HIGH AS POSSIBLE, AND COMPLYING WITH LIFE SAFETY CODES - COORDINATE ROUTING WITH HVAC. 2. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. 3. G.C. TO COORDINATE ALL LOCATIONS OF HVAC DIFFUSERS, GRILLES, ETC. SO AS TO AVOID LIGHTING FIXTURE LOCATIONS. 4. PAINT ALL EXPOSED CEILING AREAS IN A FLAT FINISH. ALL EXPOSED DUCTWORK, WIRING, CABLES, ELECTRICAL BOXES, ETC., IN THESE AREAS PAINTED TO MATCH ADJACENT SURFACES. 5. PAINT ALL WALL INTERIOR LOUVERS TO MATCH ADJACENT WALL COLOR. (ACT) 2'-0" x 4'-0" SUSPENDED ACOUSTICAL CEILING TILE (REFER TO PLAN FOR HEIGHTS) SURFACE MOUNTED EXIT SIGN (REFER TO ELECTRICAL) EXISTING RECESSED DOWNLIGHT (REFER TO ELECTRICAL) 5/8" GYPSUM BOARD CEILING PAINTED P-10 UNLESS OTHERWISE NOTED (REFER TO PLAN FOR HEIGHTS) PENDANT MOUNTED EXIT SIGN (REFER TO ELECTRICAL) --- xxx xxx CEILING HEIGHT CEILING SURFACE CEILING FINISH or LOCATION 1' x 4' SURFACE MOUNTED WRAP AROUND FIXTURE (REFER TO ELECTRICAL) EXISTING 2'-0" x 4'-0" FLUORESCENT FIXTURE TO REMAIN NEW 2'-0" x 4'-0" LED FIXTURE EXISTING HI-BAY LIGHTS TO REMAIN, TYP. U.N.O. NEW LAMINATE BEAMS IN BOTH FITTING ROOMS, TYP. REFER TO INTERIOR ELEVATIONS NOTE: REMOVE EXISTING TRACK HEADS AND REPLACE WITH NEW PROTOTYPICAL LED TRACK HEADS. QUANTITY AND LOCATIONS AS INDICATED ON THIS DRAWING. RE-USE EXISTING LENGTH OF TRACK WHERE POSSIBLE. SUPPLEMENT WITH NEW TRACK AS REQUIRED TO ALIGN WITH THE FINAL LIGHTING LAYOUT SHOWN ON THIS DRAWING. RELOCATED TRACK AND TRACK HEADS TO MATCH EXISTING SPACING AND DISTANCE FROM WALL, TYP. THROUGHOUT PERIMETER OF STORE NEW LED STRIP FIXTURE, REFER TO ELECTRICAL DRAWINGS GENERAL CEILING PLAN NOTES SCALE _ NO SCALE (ACT) ACOUSTICAL CEILING TILE INFILL, MATCH EXISTING SIZE AND TYPE OF CEILING TRACK LIGHTS AT DISPLAY WINDOWS (REFER TO ELECTRICAL) -- ROOF DECK PAINT (P-89) TV POLE MOUNTED; B.O. @ 9'-6" AFF 4 EXISTING GOOSENECK LIGHTS AT OPENING TO SECOND FLOOR 6'-0" TYP. NO CEILING - OPEN TO ABOVE NOTE: ALL EXISTING LIGHTS TO REMAIN UNLESS OTHERWISE NOTED 10'-31 4" EQ 4'-0" 4'-0" EQ 5'-0" 5'-0" 5'-0" INFILL EXISTING ACT CEILING WITH GRID AND TILE EXISTING ACT CEILING TO REMAIN, REPLACE STAINED OR DAMAGED TILES PAINT ALL SIDES OF EXISTING BULKHEAD P-164 EXISTING 2'-0" x 2'-0" LED FIXTURE -- EXIST. DECK EXPOSED 8'-0" ACT PAINT METAL DECK TO MATCH ADJACENT DECK COLOR AT FORMER ROOM LOCATION PAINT METAL DECK TO MATCH ADJACENT DECK COLOR AT FORMER ROOM LOCATION 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" TYP. 6'-0" 6'-0" TYP. TYP. 6'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. 7'-0" TYP. 9'-0" TYP. DECORATIVE PENDANT LIGHTS, BOTTOM MOUNTED AT 8'-2" AFF, HUNG FROM UNISTRUT TIGHT TO PORTAL STRUCTURE ABOVE DECORATIVE PENDANT LIGHTS, BOTTOM MOUNTED AT 8'-2" AFF, HUNG FROM UNISTRUT TIGHT TO PORTAL STRUCTURE ABOVE -- EXIST. DECK EXPOSED -- EXIST. DECK EXPOSED -- EXIST. DECK EXPOSED -- EXIST. DECK EXPOSED TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL TRACK LIGHTS AT DISPLAY GRAPHICS, REFER TO ELECTRICAL EXISTING HI-BAY LIGHT FIXTURE TO REMAIN EXISTING HI-BAY LIGHT FIXTURE TO BE RELOCATED R (N) EXISTING TRACK WITH NEW LED TRACK LIGHTS; MOUNT TO MATCH EXISTING HEIGHTS (REFER TO ELECTRICAL FOR LIGHTING TYPES) DECORATIVE PENDANT LIGHT FIXTURE (REFER TO ELECTRICAL) MOUNTED AT 8'-2" A.F.F. NEW OR RELOCATED TRACK W/ NEW LED TRACK LIGHTS; MOUNT TO MATCH EXISTING HEIGHTS (REFER TO ELECTRICAL FOR LIGHTING TYPES) (N) NEW TRACK & HEADS, TYP. AT ALL PORTALS & FITTING ROOMS (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) (N) NEW LAMINATE BEAMS IN BOTH FITTING ROOMS, TYP. REFER TO INTERIOR ELEVATIONS 1-SINGLE PANEL ILLUMINATED MIRROR IN EACH FIT. RM; SEE ELEC DWGS & COORDINATE INSTALLATION WITH VENDOR #1. 1-SINGLE PANEL ILLUMINATED MIRROR IN EACH FIT. RM; SEE ELEC DWGS & COORDINATE INSTALLATION WITH VENDOR #1. NO CEILING - OPEN TO ABOVE PAINT ALL SIDES OF EXISTING BULKHEAD P-164 INFILL EXISTING ACT CEILING WITH GRID AND TILE 2'-0" 5'-0" A3.1 SECOND FLOOR RCP Drawn By: Project No.: Date Issue SPORTING GOODS CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 Issued for Bid-Permit 03-26-21 TWK C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 05/11/21