HomeMy WebLinkAboutA3.1N
SECOND FLOOR REFLECTED CEILING PLAN SCALE FP1
3/32" = 1' - 0"
8
A
1 2 3 4 5 6 7
B
C
D
E
F
A
B
C
D
E
F
G G
4.4 5
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E E E E E E E
E E E E E E E
E E E E E
E
E
E E
E
E E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E E E E
E E E E E
E E
E E
E E E
E E E
E E E
E E E E
E E E E
E E E E
E E E E
E E E E E
E E E E E
E
E E
E
E E
E E
R
E E E E
E E E E E
E
E
E E E E
E
E
E
E
E
E
E
E
E E E
E E E
E E E E
E
E
R R
R R R
R
E E E
SYMBOL LEGEND SCALE _
NO SCALE
NEW 2'-0" x 2'-0" LED FIXTURE
(ACT) 2'-0" x 2'-0" SUSPENDED ACOUSTICAL
CEILING TILE (REFER TO PLAN FOR HEIGHTS)
GENERAL NOTES:
1. ALL SPRINKLER LINES THROUGHOUT ENTIRE STORE SHALL BE AS HIGH AS POSSIBLE, AND COMPLYING
WITH LIFE SAFETY CODES - COORDINATE ROUTING WITH HVAC.
2. SEE ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING.
3. G.C. TO COORDINATE ALL LOCATIONS OF HVAC DIFFUSERS, GRILLES, ETC. SO AS TO AVOID LIGHTING
FIXTURE LOCATIONS.
4. PAINT ALL EXPOSED CEILING AREAS IN A FLAT FINISH. ALL EXPOSED DUCTWORK, WIRING, CABLES,
ELECTRICAL BOXES, ETC., IN THESE AREAS PAINTED TO MATCH ADJACENT SURFACES.
5. PAINT ALL WALL INTERIOR LOUVERS TO MATCH ADJACENT WALL COLOR.
(ACT) 2'-0" x 4'-0" SUSPENDED ACOUSTICAL
CEILING TILE (REFER TO PLAN FOR HEIGHTS)
SURFACE MOUNTED EXIT SIGN
(REFER TO ELECTRICAL)
EXISTING RECESSED DOWNLIGHT
(REFER TO ELECTRICAL)
5/8" GYPSUM BOARD CEILING PAINTED
P-10 UNLESS OTHERWISE NOTED
(REFER TO PLAN FOR HEIGHTS)
PENDANT MOUNTED EXIT SIGN
(REFER TO ELECTRICAL)
---
xxx
xxx
CEILING HEIGHT
CEILING SURFACE
CEILING FINISH or LOCATION
1' x 4' SURFACE MOUNTED WRAP AROUND
FIXTURE (REFER TO ELECTRICAL)
EXISTING 2'-0" x 4'-0" FLUORESCENT
FIXTURE TO REMAIN
NEW 2'-0" x 4'-0" LED FIXTURE
EXISTING HI-BAY LIGHTS
TO REMAIN, TYP. U.N.O.
NEW LAMINATE BEAMS IN BOTH
FITTING ROOMS, TYP. REFER
TO INTERIOR ELEVATIONS
NOTE:
REMOVE EXISTING TRACK HEADS AND REPLACE WITH NEW
PROTOTYPICAL LED TRACK HEADS. QUANTITY AND LOCATIONS
AS INDICATED ON THIS DRAWING.
RE-USE EXISTING LENGTH OF TRACK WHERE POSSIBLE.
SUPPLEMENT WITH NEW TRACK AS REQUIRED TO ALIGN WITH
THE FINAL LIGHTING LAYOUT SHOWN ON THIS DRAWING.
RELOCATED TRACK AND TRACK HEADS TO
MATCH EXISTING SPACING AND DISTANCE FROM
WALL, TYP. THROUGHOUT PERIMETER OF STORE
NEW LED STRIP FIXTURE, REFER TO
ELECTRICAL DRAWINGS
GENERAL CEILING PLAN NOTES SCALE _
NO SCALE
(ACT) ACOUSTICAL CEILING TILE INFILL,
MATCH EXISTING SIZE AND TYPE OF CEILING
TRACK LIGHTS AT DISPLAY WINDOWS
(REFER TO ELECTRICAL)
--
ROOF DECK
PAINT (P-89)
TV POLE MOUNTED; B.O. @ 9'-6" AFF
4 EXISTING
GOOSENECK LIGHTS
AT OPENING TO
SECOND FLOOR
6'-0"
TYP.
NO CEILING -
OPEN TO ABOVE
NOTE:
ALL EXISTING LIGHTS TO REMAIN UNLESS OTHERWISE NOTED
10'-31
4"
EQ 4'-0" 4'-0" EQ
5'-0" 5'-0" 5'-0"
INFILL EXISTING
ACT CEILING WITH
GRID AND TILE
EXISTING ACT CEILING TO REMAIN,
REPLACE STAINED OR DAMAGED TILES
PAINT ALL SIDES
OF EXISTING
BULKHEAD P-164
EXISTING 2'-0" x 2'-0" LED FIXTURE
--
EXIST. DECK
EXPOSED
8'-0"
ACT
PAINT METAL DECK TO MATCH
ADJACENT DECK COLOR AT
FORMER ROOM LOCATION
PAINT METAL DECK TO MATCH
ADJACENT DECK COLOR AT
FORMER ROOM LOCATION
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
TYP.
6'-0"
6'-0" TYP.
TYP.
6'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
7'-0"
TYP.
9'-0"
TYP.
DECORATIVE PENDANT LIGHTS,
BOTTOM MOUNTED AT 8'-2" AFF,
HUNG FROM UNISTRUT TIGHT TO
PORTAL STRUCTURE ABOVE
DECORATIVE PENDANT LIGHTS,
BOTTOM MOUNTED AT 8'-2" AFF,
HUNG FROM UNISTRUT TIGHT TO
PORTAL STRUCTURE ABOVE
--
EXIST. DECK
EXPOSED
--
EXIST. DECK
EXPOSED
--
EXIST. DECK
EXPOSED
--
EXIST. DECK
EXPOSED
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
TRACK LIGHTS AT
DISPLAY GRAPHICS,
REFER TO ELECTRICAL
EXISTING HI-BAY LIGHT FIXTURE TO REMAIN
EXISTING HI-BAY LIGHT FIXTURE TO BE RELOCATED
R
(N)
EXISTING TRACK WITH NEW LED TRACK LIGHTS;
MOUNT TO MATCH EXISTING HEIGHTS (REFER
TO ELECTRICAL FOR LIGHTING TYPES)
DECORATIVE PENDANT LIGHT FIXTURE
(REFER TO ELECTRICAL) MOUNTED AT 8'-2" A.F.F.
NEW OR RELOCATED TRACK W/ NEW LED TRACK
LIGHTS; MOUNT TO MATCH EXISTING HEIGHTS
(REFER TO ELECTRICAL FOR LIGHTING TYPES)
(N)
NEW TRACK &
HEADS, TYP. AT
ALL PORTALS &
FITTING ROOMS
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N)
(N) (N)
(N)
(N)
(N)
(N)
NEW LAMINATE BEAMS IN BOTH
FITTING ROOMS, TYP. REFER
TO INTERIOR ELEVATIONS
1-SINGLE PANEL ILLUMINATED
MIRROR IN EACH FIT. RM; SEE
ELEC DWGS & COORDINATE
INSTALLATION WITH VENDOR #1.
1-SINGLE PANEL ILLUMINATED
MIRROR IN EACH FIT. RM; SEE
ELEC DWGS & COORDINATE
INSTALLATION WITH VENDOR #1.
NO CEILING -
OPEN TO ABOVE
PAINT ALL SIDES
OF EXISTING
BULKHEAD P-164
INFILL EXISTING
ACT CEILING WITH
GRID AND TILE
2'-0"
5'-0"
A3.1
SECOND FLOOR
RCP
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
Issued for
Bid-Permit
03-26-21
TWK
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
05/11/21