Loading...
HomeMy WebLinkAboutD1.0DEMOLITION LEGEND SCALE 01 N.T.S. DEMOLITION NOTES SCALE 02 N.T.S. 1. DEMOLITION PLAN SHOWS APPROXIMATE LAYOUT OF EXISTING BUILDING AND IS NOT INTENDED TO REPRESENT "AS-BUILT" CONDITIONS. G.C. IS REQUIRED TO VISIT SITE AND BECOME FAMILIAR WITH ACTUAL CONDITIONS WHEN BIDDING THE WORK. 2. PRIOR TO ANY DEMOLITION WORK, CONTRACTOR MUST FIELD VERIFY ALL EXISTING MECHANICAL, PLUMBING AND ELECTRICAL WORK LOCATED IN THE TENANT SPACE WHICH AFFECTS THE ADJACENT TENANT SPACES. THE LANDLORD AND THE ADJACENT TENANTS MUST BE NOTIFIED PRIOR TO SHUTDOWN OF ANY SHARED MECHANICAL, PLUMBING AND ELECTRICAL SYSTEMS. 72 HOUR NOTICE REQUIRED. 3. WALLS, PARTITIONS, DOORS, FRAMES, AND OTHER ITEMS TO BE REMOVED ARE SHOWN DASHED. SERVICES WITHIN WALLS AND PARTITIONS SHALL ALSO BE REMOVED. EDGES OF WALLS SHOWN TO REMAIN SHALL BE SAWCUT OR CLEANLY TOOTHED TO ACCEPT NEW CONSTRUCTION. REPAIR AND PATCH EXISTING WALLS SHOWN TO REMAIN WHERE INTERSECTING WALLS, DOORS, FRAMES, ETC. ARE SHOWN TO BE REMOVED AND WHERE EXISTING CONSTRUCTION WILL NOW BE EXPOSED IN THE NEW CONSTRUCTION. 4. G.C. TO DISPOSE OF ALL INTERIOR MERCURY LAMPS VIA PROPER DISPOSAL REQUIREMENTS. 5. EXISTING CONSTRUCTION SHOWN TO REMAIN SHALL BE PROTECTED DURING DEMOLITION. DAMAGE TO EXISTING CONSTRUCTION SHOWN TO REMAIN SHALL BE RESTORED TO MATCH PRE-DAMAGED CONDITION. 6. PROVIDE ALL NECESSARY SHORING, BRACING, AND SUPPORT TO PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT STRUCTURE OR ELEMENT SHOWN TO REMAIN. SHORING AND BRACING SHALL BE DESIGNED BY CONTRACTOR'S PROFESSIONAL ENGINEER LICENSED IN THE APPLICABLE JURISDICTION. 7. PROVIDE TEMPORARY WEATHER PROTECTION AND SECURITY DEVICES DURING INTERVAL BETWEEN DEMOLITION AND REMOVAL OF EXISTING CONSTRUCTION ON EXTERIOR SURFACES AND INSTALLATION OF NEW CONSTRUCTION TO ENSURE THAT NO WATER LEAKAGE OR DAMAGE OCCURS TO STRUCTURE OR TO INTERIOR AREAS OF EXISTING BUILDING. 8. EXISTING CONCRETE FLOOR SLABS, MASONRY WALLS AND EXISTING STRUCTURAL FRAMING SYSTEMS SHOWN TO BE REMOVED SHALL BE CLEANLY SAWCUT FROM EXISTING CONSTRUCTION. COMPLETELY REMOVE FOOTINGS, FOUNDATIONS AND ABOVE GROUND AND UNDERGROUND CONSTRUCTION. 9. WHERE FINISHES ARE SHOWN TO BE REMOVED FROM EXISTING CONSTRUCTION, REPAIR AND PATCH REMAINING SUBSTRATE AND PREPARE FOR NEW FINISH. REPAIR AND PATCH ALL REMAINING SUBSTRATES THAT WERE ORIGINALLY CONCEALED BY EXISTING FINISHES, BUT WILL NOW BE EXPOSED IN THE NEW CONSTRUCTION. 10. SALVAGE MATERIAL AS REQUIRED FOR PATCHING AND INFILL (SEE DRAWINGS FOR NEW WORK). SALVAGE MATERIAL SHALL BE CLEANED AND STORED IN AREAS AWAY FROM THE DEMOLITION OR UNTIL NEEDED. 11. ALL INFILL OR REPLACEMENT WORK SHALL MATCH EXISTING CONDITIONS IN MATERIALS, CONSTRUCTION AND FINISH, UNLESS SPECIFICALLY NOTED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS. 12. G.C. TO COORDINATE REUSE OF ALL MECHANICAL AND FIRE SPRINKLER SYSTEMS EQUIPMENT WITH THE MECHANICAL PLUMBING DWGS. AND REMOVE ALL EXISTING OBSOLETE PLUMBING, FIRE SPRINKLER, MECHANICAL, AND ELECTRICAL EQUIPMENT IN THEIR ENTIRETY THROUGHOUT TENANT SPACE. G.C. TO CONFIRM PARTICULARLY WHERE EXISTING ITEMS WILL INTERFERE WITH THE INSTALLATION OF NEW CONSTRUCTION, OR WHERE EXISTING ITEMS WILL BE EXPOSED IN THE NEW CONSTRUCTION. COORDINATE WITH NEW CONSTRUCTION. 13. COLOR OF PATCHING FOR CONCRETE SURFACES TO BE GRAY IN COLOR TO MATCH ADJACENT EXISTING SURFACE. 14. G.C. MUST COORDINATE W/ LANDLORD ON PARKING, MATERIAL STORAGE, TRAILERS, ETC. G.C. MUST PROVIDE BARRICADES AND WARNING SIGNS AS REQUIRED TO RESTRICT ACCESS BY UNAUTHORIZED PERSONNEL TO THE AREAS OF THE WORK DURING DEMOLITION / CONSTRUCTION. 15. G.C TO COORD. DEMOLITION OF ALL EXISTING SYSTEMS WITH NEW SYSTEMS AND READ THIS DRAWING IN CONJUNCTION WITH ALL MECH, ELECT, PLUMBING AND FIRE PROTECTION DWGS. FOR COMPLETE SCOPE OF DEMOLITION WORK, TYP. 16. G.C TO COORD. ALL EXISTING & NEW UTILITIES WITH UTILITY COMPANY PRIOR TO START OF WORK. EXISTING TO BE REMOVED EXISTING WALL TO REMAIN NOTE: UNLESS OTHERWISE NOTED, ALL DOORS, FRAMES AND HARDWARE TO REMAIN. PROVIDE NEW HARDWARE FOR ALL NEW DOORS AS SCHEDULED, SEE A5.0 FOR ADDITIONAL INFORMATION. NO WORK IN THIS AREA APPROXIMATE AREA OF NEW WORK LEGEND DP1 FIRST FLOOR DEMOLITION FLOOR PLAN SCALE 3/32" = 1' - 0" N 1 2 3 4 5 6 7 8 A B C D E F A B C D E F G G 4.4 5 DEMO ROOM COMPLETE REMOVE EXISTING L-SHAPED WALL REMOVE ALL GRAPHIC OVALS AND PERIMETER WAYFINDING, TYP. THROUGHOUT SALES FLOOR REMOVE EXISTING FITTING ROOM COMPLEX COMPLETE NO WORK TO BE DONE IN SHADED AREA, U.N.O. REMOVE EXISTING DISPLAY WALL REMOVE UA WALLS AND ESCALATOR LETTERING EXISTING SHELL WALL TO REMAIN, TYP. (U.N.O.) EXISTING AISLE FLOORING TO REMAIN TYP., COORD. W/ SHEET A2.0 EXISTING FIXTURES TO BE RELOCATED BY STORE PERSONNEL; COORD. W/ DSG AND FIXTURE PLAN REMOVE EXISTING CHECKOUT COUNTERS, COORD. DEMO WITH ELEC DWGS REMOVE CART CORRAL NOTE: ALL EXISTING BASE TO BE REMOVED THROUGHOUT SALES FLOOR REMOVE EXISTING PERIMETER WALL FIXTURES, TYP. EXISTING HITTRAX BATTING CAGE TO BE RELOCATED TO THE SECOND FLOOR, COORDINATE DEMO OF POWER AND DATA W/ ELEC DWGS EXISTING FLOOR MEDALLIONS TO REMAIN, TYP. OF 3 EXISTING DOOR FRAME TO REMAIN. REMOVE AND RELOCATE EXISTING IMPACT DOORS TO NEW LOCATION. COORD. W/ A1.0 REMOVE EXISTING DISPLAY WALL REMOVE EXISTING DISPLAY WALL REMOVE EXISTING DISPLAY WALL REMOVE EXISTING DOOR FRAME REMOVE EXISTING STUD WALLS, PATCH/REPAIR GYP. BD. AT STAIR EXISTING PERIMETER CARPET TO REMAIN, TYP. U.N.O. REMOVE EXISTING PAD FLOORING, COORD. W/ SHEET A2.0 REMOVE EXISTING PAD FLOORING, COORD. W/ SHEET A2.0 REMOVE EXISTING PAD FLOORING, COORD. W/ SHEET A2.0 REMOVE EXISTING PAD FLOORING, COORD. W/ SHEET A2.0 REMOVE EXISTING FITTING ROOM COMPLEX COMPLETE REMOVE EXISTING L-SHAPED WALL REMOVE CHANGING ROOM WALLS, FLOORING, DOOR & FRAME, & ACCESSORIES EXISTING WALL TO REMAIN, PROTECT DURING DEMOLITION REMOVE CART CORRAL REMOVE CART CORRAL EXISTING VESTIBULE FLOORING TO BE REMOVED AND REPLACED WITH NEW FLOORING EXISTING VESTIBULE FLOORING TO BE REMOVED AND REPLACED WITH NEW FLOORING EXISTING VESTIBULE FLOORING TO BE REMOVED AND REPLACED WITH NEW FLOORING REMOVE EXISTING CHECKOUT COUNTERS, COORD. DEMO WITH ELEC DWGS REMOVE EXISTING CHECKOUT COUNTERS, COORD. DEMO WITH ELEC DWGS REMOVE EXISTING STUD WALL REMOVE EXISTING ROOMS COMPLETE REMOVE EXISTING ROOMS COMPLETE REMOVE EXISTING CAST IRON PIPE COMPLETE, BACK TO POINT OF ORIGIN. REMOVE DOOR AND FRAME REMOVE DOOR AND FRAME REMOVE EXISTING DISPLAY WALL EXISTING PERIMETER CARPET TO REMAIN, TYP. U.N.O. EXISTING PERIMETER CARPET TO REMAIN, TYP. U.N.O. ±15'-6" DEMO FLOORING ±22'-8" DEMO FLOORING REMOVE EXISTING FLOORING IN THIS AREA AS NOTED REMOVE EXISTING FLOORING IN THIS AREA AS NOTED ±20'-0" DEMO FLOORING REMOVE EXISTING FLOORING IN THIS AREA AS NOTED EXISTING PIPE ABOVE TO REMAIN FOR HOSE BIBB REMOVE EXISTING LVT AISLE FLOORING, COORD. W/ SHEET A2.0 REMOVE EXISTING UA FLOORING, COORD. W/ SHEET A2.0 REMOVE EXISTING UA FLOORING, COORD. W/ SHEET A2.0 REMOVE UA WALLS AND ESCALATOR LETTERING REMOVE UA WALLS AND ESCALATOR LETTERING D1.0 FIRST FLOOR DEMOLITION FLOOR PLAN Drawn By: Project No.: Date Issue SPORTING GOODS CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 Issued for Bid-Permit 03-26-21 TWK C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 05/11/21