HomeMy WebLinkAboutD1.1DEMOLITION NOTES SCALE 02
1/16" = 1' - 0"
1. DEMOLITION PLAN SHOWS APPROXIMATE LAYOUT OF EXISTING BUILDING AND IS NOT INTENDED TO REPRESENT
"AS-BUILT" CONDITIONS. G.C. IS REQUIRED TO VISIT SITE AND BECOME FAMILIAR WITH ACTUAL CONDITIONS WHEN
BIDDING THE WORK.
2. PRIOR TO ANY DEMOLITION WORK, CONTRACTOR MUST FIELD VERIFY ALL EXISTING MECHANICAL, PLUMBING AND
ELECTRICAL WORK LOCATED IN THE TENANT SPACE WHICH AFFECTS THE ADJACENT TENANT SPACES. THE LANDLORD
AND THE ADJACENT TENANTS MUST BE NOTIFIED PRIOR TO SHUTDOWN OF ANY SHARED MECHANICAL, PLUMBING AND
ELECTRICAL SYSTEMS. 72 HOUR NOTICE REQUIRED.
3. WALLS, PARTITIONS, DOORS, FRAMES, AND OTHER ITEMS TO BE REMOVED ARE SHOWN DASHED. SERVICES WITHIN
WALLS AND PARTITIONS SHALL ALSO BE REMOVED. EDGES OF WALLS SHOWN TO REMAIN SHALL BE SAWCUT OR
CLEANLY TOOTHED TO ACCEPT NEW CONSTRUCTION. REPAIR AND PATCH EXISTING WALLS SHOWN TO REMAIN WHERE
INTERSECTING WALLS, DOORS, FRAMES, ETC. ARE SHOWN TO BE REMOVED AND WHERE EXISTING CONSTRUCTION WILL
NOW BE EXPOSED IN THE NEW CONSTRUCTION.
4. G.C. TO DISPOSE OF ALL INTERIOR MERCURY LAMPS VIA PROPER DISPOSAL REQUIREMENTS.
5. EXISTING CONSTRUCTION SHOWN TO REMAIN SHALL BE PROTECTED DURING DEMOLITION. DAMAGE TO EXISTING
CONSTRUCTION SHOWN TO REMAIN SHALL BE RESTORED TO MATCH PRE-DAMAGED CONDITION.
6. PROVIDE ALL NECESSARY SHORING, BRACING, AND SUPPORT TO PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE OF
STRUCTURE OR ELEMENT TO BE DEMOLISHED, AND ADJACENT STRUCTURE OR ELEMENT SHOWN TO REMAIN. SHORING
AND BRACING SHALL BE DESIGNED BY CONTRACTOR'S PROFESSIONAL ENGINEER LICENSED IN THE APPLICABLE
JURISDICTION.
7. PROVIDE TEMPORARY WEATHER PROTECTION AND SECURITY DEVICES DURING INTERVAL BETWEEN DEMOLITION AND
REMOVAL OF EXISTING CONSTRUCTION ON EXTERIOR SURFACES AND INSTALLATION OF NEW CONSTRUCTION TO ENSURE
THAT NO WATER LEAKAGE OR DAMAGE OCCURS TO STRUCTURE OR TO INTERIOR AREAS OF EXISTING BUILDING.
8. EXISTING CONCRETE FLOOR SLABS, MASONRY WALLS AND EXISTING STRUCTURAL FRAMING SYSTEMS SHOWN TO BE
REMOVED SHALL BE CLEANLY SAWCUT FROM EXISTING CONSTRUCTION. COMPLETELY REMOVE FOOTINGS,
FOUNDATIONS AND ABOVE GROUND AND UNDERGROUND CONSTRUCTION.
9. WHERE FINISHES ARE SHOWN TO BE REMOVED FROM EXISTING CONSTRUCTION, REPAIR AND PATCH REMAINING
SUBSTRATE AND PREPARE FOR NEW FINISH. REPAIR AND PATCH ALL REMAINING SUBSTRATES THAT WERE ORIGINALLY
CONCEALED BY EXISTING FINISHES, BUT WILL NOW BE EXPOSED IN THE NEW CONSTRUCTION.
10. SALVAGE MATERIAL AS REQUIRED FOR PATCHING AND INFILL (SEE DRAWINGS FOR NEW WORK). SALVAGE MATERIAL
SHALL BE CLEANED AND STORED IN AREAS AWAY FROM THE DEMOLITION OR UNTIL NEEDED.
11. ALL INFILL OR REPLACEMENT WORK SHALL MATCH EXISTING CONDITIONS IN MATERIALS, CONSTRUCTION AND FINISH,
UNLESS SPECIFICALLY NOTED ELSEWHERE IN THE CONSTRUCTION DOCUMENTS.
12. G.C. TO COORDINATE REUSE OF ALL MECHANICAL AND FIRE SPRINKLER SYSTEMS EQUIPMENT WITH THE MECHANICAL
PLUMBING DWGS. AND REMOVE ALL EXISTING OBSOLETE PLUMBING, FIRE SPRINKLER, MECHANICAL, AND ELECTRICAL
EQUIPMENT IN THEIR ENTIRETY THROUGHOUT TENANT SPACE. G.C. TO CONFIRM PARTICULARLY WHERE EXISTING ITEMS
WILL INTERFERE WITH THE INSTALLATION OF NEW CONSTRUCTION, OR WHERE EXISTING ITEMS WILL BE EXPOSED IN THE
NEW CONSTRUCTION. COORDINATE WITH NEW CONSTRUCTION.
13. COLOR OF PATCHING FOR CONCRETE SURFACES TO BE GRAY IN COLOR TO MATCH ADJACENT EXISTING SURFACE.
14. G.C. MUST COORDINATE W/ LANDLORD ON PARKING, MATERIAL STORAGE, TRAILERS, ETC.
G.C. MUST PROVIDE BARRICADES AND WARNING SIGNS AS REQUIRED TO RESTRICT ACCESS BY UNAUTHORIZED PERSONNEL
TO THE AREAS OF THE WORK DURING DEMOLITION / CONSTRUCTION.
15. G.C TO COORD. DEMOLITION OF ALL EXISTING SYSTEMS WITH NEW SYSTEMS AND READ THIS DRAWING IN CONJUNCTION
WITH ALL MECH, ELECT, PLUMBING AND FIRE PROTECTION DWGS. FOR COMPLETE SCOPE OF DEMOLITION WORK, TYP.
16. G.C TO COORD. ALL EXISTING & NEW UTILITIES WITH UTILITY COMPANY PRIOR TO START OF WORK.
DP1
SECOND FLOOR DEMOLITION FLOOR PLAN SCALE
3/32" = 1' - 0"
N
EXISTING TO BE REMOVED
EXISTING WALL TO REMAIN
DEMOLITION LEGEND SCALE 01
3/32" = 1' - 0"
8
A
1 2 3 4 5 6 7
B
C
D
E
F
A
B
C
D
E
F
G G
4.4 5
NOTE:
UNLESS OTHERWISE NOTED, ALL DOORS, FRAMES
AND HARDWARE TO REMAIN. PROVIDE NEW
HARDWARE FOR ALL NEW DOORS AS SCHEDULED,
SEE A5.0 FOR ADDITIONAL INFORMATION.
NO WORK IN THIS AREA
APPROXIMATE AREA OF NEW WORK
LEGEND
DEMO ROOM COMPLETE
EXISTING SHELL WALL
TO REMAIN, TYP. (U.N.O.)
REMOVE ALL GRAPHIC
OVALS AND PERIMETER
WAYFINDING, TYP.
THROUGHOUT SALES FLOOR
EXISTING AISLE FLOORING TO
REMAIN TYP., COORD. W/ SHEET A2.0
EXISTING FIXTURES TO BE
RELOCATED BY STORE
PERSONNEL; COORD. W/ DSG
AND FIXTURE PLAN
NOTE:
ALL EXISTING BASE TO BE REMOVED
THROUGHOUT SALES FLOOR
REMOVE EXISTING PERIMETER
WALL FIXTURES, TYP.
EXISTING IMPACT
DOOR & FRAME TO
BE REMOVED
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING STUD WALLS,
PATCH/REPAIR GYP. BD. AT STAIR
REMOVE EXISTING PAD
FLOORING, COORD. W/
SHEET A2.0
REMOVE EXISTING PAD
FLOORING, COORD. W/
SHEET A2.0
REMOVE EXISTING
ROOM COMPLETE
REMOVE
GLAZING, DOOR
AND FRAME
REMOVE EXISTING
DISPLAY WALL
EXISTING PERIMETER
CARPET TO REMAIN,
TYP. U.N.O.
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
FITTING ROOMS
COMPLETE
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
STUD WALLS
EXISTING 4" GAS
PIPING FROM ROOF,
DOWN THROUGH
2ND FLOOR SLAB
REMOVE EXISTING
DOORS AND
GLAZING SYSTEMS
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
DISPLAY WALL
REMOVE EXISTING
HEAVY TIMBER
DISPLAY WALL &
GRIDS
REMOVE EXISTING
MILLWORK
DISPLAY WALL
REMOVE EXISTING PAD
FLOORING, COORD. W/
SHEET A2.0
REMOVE EXISTING PAD
FLOORING, COORD. W/
SHEET A2.0
REMOVE EXISTING PAD
FLOORING, COORD. W/
SHEET A2.0
REMOVE EXISTING
CARPET, COORD. W/
SHEET A2.0
REMOVE EXISTING
CERAMIC TILE FLOORING,
COORD. W/ SHEET A2.0
EXISTING AISLE FLOORING TO
REMAIN TYP., COORD. W/ SHEET A2.0
EXISTING PERIMETER
CARPET TO REMAIN,
TYP. U.N.O.
EXISTING
PERIMETER LVT
TO REMAIN,
TYP. U.N.O.
EXISTING
PERIMETER LVT
TO REMAIN,
TYP. U.N.O.
EXISTING
PERIMETER LVT
TO REMAIN,
TYP. U.N.O.
REMOVE EXISTING LVT,
COORD. W/ SHEET A2.0
REMOVE EXISTING WALL
REMOVE EXISTING
DOOR & FRAME
REMOVE
EXISTING LVT,
COORD. W/
SHEET A2.0
D1.1
SECOND FLOOR
DEMOLITION
FLOOR PLAN
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
Issued for
Bid-Permit
03-26-21
TWK
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
05/11/21