Loading...
HomeMy WebLinkAboutE01.03x1 3x1 3x1 3x2 4x1 4x1 4x1 4x1 4x1 4x1 4x2 4x2 3x2 4x1 4x1 4x1 4x1 3x2 4x1 4x1 3x1 3x1 R R R R R R 49" TV 1 2 3 4 5 6 7 8 A B C D E F A B C D E F G G 4.4 5 1PLAN FIRST FLOOR LIGHTING SCALE: 3/32" = 1'-0" SWITCH LEG DESIGNATION S S S b c d A / 2 LEGEND LIGHT FIXTURE TYPE CIRCUIT # b SWITCH LEG OS b,c {NOTES:} 1. SWITCH LEG DESIGNATIONS ARE MATCHED BETWEEN CONTROL DEVICES AND LIGHT FIXTURES LOCATED IN THE SAME ROOM UNLESS NOTED OTHERWISE. CONTACT ENGINEER IF CLARIFICATION IS REQUIRED. 2. SUBSCRIPT 'a' DENOTES FIXTURE TO RECEIVE AN ADDITIONAL UNSWITCHED HOT LEG ROUTED AROUND ALL CONTROLS THAT MUST ALWAYS REMAIN ON TO EACH EMERGENCY BATTERY PACK OR EXIT SIGN. WHERE NOT NOTED AS "NL," FIXTURE'S NORMAL OPERATION SHALL BE ON CONTROLLED LEG OF CIRCUIT. 3. ALL LIGHT FIXTURES ARE FED FROM PANEL "Y" UNLESS OTHERWISE NOTED. EM EMERGENCY W/ BATTERY BACKUP NLLIGHT NIGHT 1. ALL EXISTING LIGHTING IN HATCHED AREA IS EXISTING TO REMAIN 'X'. MAINTAIN ALL EXISTING CONTROLS AND RELATED WIRING BACK TO PANELS OR POINT OF COMMON USAGE. { }2. INSTALL NEW TRACK HEADS, TYPE 'DWW', ON EXISTING TRACK IN ARRANGEMENT SHOWN. { }3. NEW LOCATION OF RELOCATED TRACK. RECONFIGURE TRACK FOR ARRANGEMENT SHOWN. CONTACT VENDOR #18 FOR ADDITIONAL MOUNTING HARDWARE, CONNECTORS, TRACK SECTIONS, ETC. AS REQUIRED TO COMPLETE INSTALLATION. INSTALL ALL NEW TRACK HEADS ON THIS TRACK, TYPE 'DWW'. { }4. NEW LOCATION OF RELOCATED TRACK OR NEW TRACK. RECONFIGURE EXISTING TRACK FOR ARRANGEMENT SHOWN. CONTACT VENDOR #18 FOR ADDITIONAL MOUNTING HARDWARE, CONNECTORS, TRACK SECTIONS, ETC. AS REQUIRED TO COMPLETE INSTALLATION. INSTALL ALL NEW PROTOTYPE TRACK HEADS ON THIS TRACK, TYPES AS NOTED. 5. ELECTRICAL CONTRACTOR SHALL WIRE MIRROR LIGHTING PER MANUFACTURER'S INSTRUCTIONS. JUNCTION BOX SHALL BE CONCEALED BEHIND MIRROR.{ }6. INSTALL NEW TRACK HEADS, TYPE 'GF1', ON EXISTING TRACK IN ARRANGEMENT SHOWN. { }7. COORDINATE EXACT LOCATION OF PENDANT FIXTURES IN THE FITTING ROOMS WITH THE DICK'S SPORTING GOODS REPRESENTATIVE PRIOR TO ROUGH-IN. { }8. ELECTRICAL CONTRACTOR SHALL WIRE MIRROR LIGHTING PER MANUFACTURER'S INSTRUCTIONS. JUNCTION BOX SHALL BE CONCEALED BEHIND MIRROR. WIRE MIRROR TO EXISTING CIRCUIT PREVIOUSLY FEEDING WALL SCONCE IN THIS FITTING ROOM. { }9. MOUNT TYPE 'LG1' AND 'LG1EM' FIXTURES IN STOCK ROOM @ 15'-0" AFF BETWEEN SHELVING. E.C. SHALL PROVIDE UNISTRUT AT STUCTURE ABOVE TO CHAIN-HANG FIXTURES AT HEIGHT INDICATED. PROVIDE CHAIN AND ALL NECESSARY MOUNTING HARDWARE. POWER SHALL BE ROUTED FROM JUNCTION BOX AT UNISTRUT DOWN THROUGH MC CABLE ZIP-TIED TO CHAIN TO FIXTURE. (TYPICAL) { }10. STOCKROOM OCCUPANCY SENSOR TO BE INSTALLED DIRECTLY TO END OF FIXTURE VIA KNOCKOUT ON THE FIXTURE HOUSING. { }11. COORDINATE EXACT LOCATION OF PENDANT FIXTURES IN THE FITTING ROOMS WITH THE DICK'S SPORTING GOOD REPRESENTATIVE PRIOR TO ROUGH-IN. POWER SHALL BE ROUTED TO FIXTURE THROUGH PORTAL WALLS FROM THE BELOW CONDUIT ROUTED TO PORTAL. 12. ELECTRICAL CONTRACTOR SHALL WIRE EMERGENCY BATTERY OF FIXTURE TO NON-CONTROLLED SIDE OF A. ALL GENERAL LIGHTING CIRCUITS SHOWN ON THIS LIGHTING PLAN ARE FROM EXISTING PANEL 'A1' LOCATED IN POWER WALL IN REAR OF STORE UNLESS NOTED OTHERWISE AND ALL CIRCUITS SHOWN ON TRACK LIGHTING PLAN ARE FROM PANELS ''. B. ALL CIRCUITS SHOWN ON DRAWING ARE FOR REFERENCE ONLY. E.C. IS TO FIELD VERIFY NUMBER OF SPARE CIRCUIT BREAKERS AND SPACES IN EXISTING PANELS AND REUSE FOR NEW CIRCUITS SHOWN ON DRAWING. E.C. IS TO VERIFY LOADS ON PANELS AFTER DEMO OF EXISTING CIRCUITS AND ADDING NEW CIRCUITS TO PANELS. PROVIDE NEW CIRCUIT BREAKERS OR REUSE EXISTING IN PANELS. MATCH PANEL TYPES AND U.L. RATINGS. C. E.C. SHALL FIELD VERIFY ALL EXISTING CIRCUITS SHOWN TO BE REUSED HAVE AMPLE LOAD CAPACITY FOR WORK INDICATED. E.C. SHALL VERIFY THAT EXISTING CONDITIONS ARE AS SHOWN ON DRAWINGS. IF A DISCREPANCY EXISTS THAT WILL AFFECT THE WORK, IT SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE OWNER AND ENGINEER. D. ALL LIGHT FIXTURES ARE CONTROLLED BY ENERGY MANAGEMENT SYSTEM. E. ELECTRICAL CONTRACTOR SHALL VERIFY THE PROPER MOUNTING HEIGHT OF THE EMERGENCY FIXTURES WITH THE LOCAL FIRE MARSHALL PRIOR TO INSTALLATION. F. REFER TO DRAWING E2.0 FOR ROOM/AREA NAMES. G. SEE LIGHT FIXTURE SCHEDULE ON DRAWING E4.0. H. ALL BRANCH CIRCUITS MORE THAN 100 FEET IN LENGTH FOR 120 VOLT CIRCUITS AND 200 FEET FOR 277 VOLT CIRCUITS SHALL BE MINIMUM #10 AWG. I. REFER TO THIS DRAWING FOR EXACT LOCATION AND MOUNTING HEIGHT OF ALL LIGHT FIXTURES. COORDINATE WITH ARCHITECTS REFLECTED CEILING PLAN PRIOR TO ROUGH-IN. J. ALL CONDUITS RUN IN EXPOSED CEILING AREAS SHALL BE RUN WITH STRUCTURE TIGHT TO UNDER SIDE OF ROOF DECKING IN ACCORDANCE WITH N.E.C. ARTICLE 300.4(E). K. PROVIDE ADDITIONAL EXIT SIGNS TO MATCH EXISTING IN PROJECT AREA AS DIRECTED BY THE LOCAL AUTHORITY 'XRN' 'XRN' 'XRN' 'XRN' 'XRN' 'XRN' \pxqc;ALL LIGHTING FIXTURES SHOWN ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE 4 'XRN' GFLW 4 'XRN' GFLW 4 'XRN' GFLW 4 'XRN' GFLW 4 'XRN' GFLW 4 'XRN' GFLW 4 'XRN' GFLW 4 'XRN' GFLW 2 'XRW' 2 'XRW' 3 'XRN' 3 'XRN' 2 'XRW' 3 'XRN' 3 'XRN' 3 'XRN' 2 'XRW' 4 'XRN' DWW 4 'XRN' DWW2 'XRW' 4 'XRN' DWW 2 'XRW' 4 'XRN' DWW 2 'XRW' 4 'XRN' DWW 4 'XRN' DWW 2 'XRW' 2 'XRW' 'XRN' 3 4 'XRN' GFLW 3 'XRN' 4 'XRN' DWW 1 6 'XRW' AEM/ A1-3a A/A1-3 A/A1-3 AEM/ A1-3a A/A1-3 6 'XRW' (TYP.) 9 LG1EM/A1-3a,b b M2 LG1/A1-3b LG1/A1-3c LG1/A1-3c c M2 S2/AA1-1a LG1EM/A1-3a,d d M2 LG1/A1-3d LG1/A1-3d 6 'XRW' 6 'XRW' 6 'XRW' S2/AA1-1a S2/AA1-1a J J R5/'CTX'a 12 8 11 12 FR/'CTX' 'XRW' R5/'CTX'a J J R5/'CTX'a 12 8 11 12 FR/'CTX' 'XRW' R5/'CTX'a 4 'XRN' GFLW Mar 26, 2021 - 17:36:33 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_E1.0,1.1.dwg Updated By: rvan E1.0 FIRST FLOOR LIGHTING PLAN PJN CONTRACTOR MUST VERIFY DIMENSIONS ALL CLEARANCES IN AND FIELD Drawn By: Project No.: Date Issue SPORTING GOODS Design and construction documents as instruments of service are given in confidence and remain the property of MCG Architects. The use of this design and these construction documents for purposes other than the specific project named herein is strictly prohibited without expressed written consent of MCG Architects, Incorporated. STORE # 183 21042.10 C MCG ARCHITECTS 2021 ALL RIGHTS RESERVED **With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the General Contractor to purchase and install complete as shown and referenced. The General Contractor is required to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant (Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.** 25001 Emery Road, Suite #200 Warrensville Heights, Ohio 44128 Phone: 216-292-4696 Fax: 216-292-5874 Email: mail@mchenryassociates.com Issued for Bid-Permit 03-26-21 T F \pxql;216.520.1551 \pxql;216.520.1567 03-26-21 SM CLAY TERRACE 14350 CLAY TERRACE BLVD. CARMEL, IN 46032 05/11/21