HomeMy WebLinkAboutE01.03x1 3x1
3x1
3x2
4x1 4x1 4x1
4x1 4x1 4x1
4x2 4x2 3x2
4x1 4x1
4x1 4x1
3x2
4x1
4x1
3x1
3x1
R R R R
R
R
49" TV
1 2 3
4 5
6 7 8
A
B
C
D
E
F
A
B
C
D
E
F
G G
4.4 5
1PLAN FIRST FLOOR LIGHTING
SCALE: 3/32" = 1'-0"
SWITCH LEG DESIGNATION
S S S
b c d
A / 2
LEGEND
LIGHT FIXTURE TYPE
CIRCUIT #
b
SWITCH LEG
OS b,c
{NOTES:}
1. SWITCH LEG DESIGNATIONS ARE MATCHED BETWEEN CONTROL DEVICES AND LIGHT FIXTURES
LOCATED IN THE SAME ROOM UNLESS NOTED OTHERWISE. CONTACT ENGINEER IF CLARIFICATION
IS REQUIRED.
2. SUBSCRIPT 'a' DENOTES FIXTURE TO RECEIVE AN ADDITIONAL UNSWITCHED HOT LEG ROUTED
AROUND ALL CONTROLS THAT MUST ALWAYS REMAIN ON TO EACH EMERGENCY BATTERY PACK
OR EXIT SIGN. WHERE NOT NOTED AS "NL," FIXTURE'S NORMAL OPERATION SHALL BE ON
CONTROLLED LEG OF CIRCUIT.
3. ALL LIGHT FIXTURES ARE FED FROM PANEL "Y" UNLESS OTHERWISE NOTED.
EM
EMERGENCY W/ BATTERY BACKUP
NLLIGHT NIGHT
1. ALL EXISTING LIGHTING IN HATCHED AREA IS EXISTING TO
REMAIN 'X'. MAINTAIN ALL EXISTING CONTROLS AND
RELATED WIRING BACK TO PANELS OR POINT OF COMMON
USAGE.
{
}2. INSTALL NEW TRACK HEADS, TYPE 'DWW', ON EXISTING
TRACK IN ARRANGEMENT SHOWN.
{
}3. NEW LOCATION OF RELOCATED TRACK. RECONFIGURE
TRACK FOR ARRANGEMENT SHOWN. CONTACT VENDOR #18
FOR ADDITIONAL MOUNTING HARDWARE, CONNECTORS,
TRACK SECTIONS, ETC. AS REQUIRED TO COMPLETE
INSTALLATION. INSTALL ALL NEW TRACK HEADS ON THIS
TRACK, TYPE 'DWW'.
{
}4. NEW LOCATION OF RELOCATED TRACK OR NEW TRACK.
RECONFIGURE EXISTING TRACK FOR ARRANGEMENT
SHOWN. CONTACT VENDOR #18 FOR ADDITIONAL MOUNTING
HARDWARE, CONNECTORS, TRACK SECTIONS, ETC. AS
REQUIRED TO COMPLETE INSTALLATION. INSTALL ALL NEW
PROTOTYPE TRACK HEADS ON THIS TRACK, TYPES AS
NOTED.
5. ELECTRICAL CONTRACTOR SHALL WIRE MIRROR
LIGHTING PER MANUFACTURER'S INSTRUCTIONS. JUNCTION
BOX SHALL BE CONCEALED BEHIND MIRROR.{
}6. INSTALL NEW TRACK HEADS, TYPE 'GF1', ON EXISTING
TRACK IN ARRANGEMENT SHOWN.
{
}7. COORDINATE EXACT LOCATION OF PENDANT FIXTURES
IN THE FITTING ROOMS WITH THE DICK'S SPORTING GOODS
REPRESENTATIVE PRIOR TO ROUGH-IN.
{
}8. ELECTRICAL CONTRACTOR SHALL WIRE MIRROR
LIGHTING PER MANUFACTURER'S INSTRUCTIONS. JUNCTION
BOX SHALL BE CONCEALED BEHIND MIRROR. WIRE MIRROR
TO EXISTING CIRCUIT PREVIOUSLY FEEDING WALL SCONCE
IN THIS FITTING ROOM.
{
}9. MOUNT TYPE 'LG1' AND 'LG1EM' FIXTURES IN STOCK
ROOM @ 15'-0" AFF BETWEEN SHELVING. E.C. SHALL
PROVIDE UNISTRUT AT STUCTURE ABOVE TO CHAIN-HANG
FIXTURES AT HEIGHT INDICATED. PROVIDE CHAIN AND ALL
NECESSARY MOUNTING HARDWARE. POWER SHALL BE
ROUTED FROM JUNCTION BOX AT UNISTRUT DOWN
THROUGH MC CABLE ZIP-TIED TO CHAIN TO FIXTURE.
(TYPICAL)
{
}10. STOCKROOM OCCUPANCY SENSOR TO BE INSTALLED
DIRECTLY TO END OF FIXTURE VIA KNOCKOUT ON THE
FIXTURE HOUSING.
{
}11. COORDINATE EXACT LOCATION OF PENDANT FIXTURES
IN THE FITTING ROOMS WITH THE DICK'S SPORTING GOOD
REPRESENTATIVE PRIOR TO ROUGH-IN. POWER SHALL BE
ROUTED TO FIXTURE THROUGH PORTAL WALLS FROM THE
BELOW CONDUIT ROUTED TO PORTAL.
12. ELECTRICAL CONTRACTOR SHALL WIRE EMERGENCY
BATTERY OF FIXTURE TO NON-CONTROLLED SIDE OF
A. ALL GENERAL LIGHTING CIRCUITS SHOWN ON THIS
LIGHTING PLAN ARE FROM EXISTING PANEL 'A1' LOCATED IN
POWER WALL IN REAR OF STORE UNLESS NOTED
OTHERWISE AND ALL CIRCUITS SHOWN ON TRACK
LIGHTING PLAN ARE FROM PANELS ''.
B. ALL CIRCUITS SHOWN ON DRAWING ARE FOR
REFERENCE ONLY. E.C. IS TO FIELD VERIFY NUMBER OF
SPARE CIRCUIT BREAKERS AND SPACES IN EXISTING
PANELS AND REUSE FOR NEW CIRCUITS SHOWN ON
DRAWING. E.C. IS TO VERIFY LOADS ON PANELS AFTER
DEMO OF EXISTING CIRCUITS AND ADDING NEW CIRCUITS
TO PANELS. PROVIDE NEW CIRCUIT BREAKERS OR REUSE
EXISTING IN PANELS. MATCH PANEL TYPES AND U.L.
RATINGS.
C. E.C. SHALL FIELD VERIFY ALL EXISTING CIRCUITS
SHOWN TO BE REUSED HAVE AMPLE LOAD CAPACITY FOR
WORK INDICATED. E.C. SHALL VERIFY THAT EXISTING
CONDITIONS ARE AS SHOWN ON DRAWINGS. IF A
DISCREPANCY EXISTS THAT WILL AFFECT THE WORK, IT
SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF
THE OWNER AND ENGINEER.
D. ALL LIGHT FIXTURES ARE CONTROLLED BY ENERGY
MANAGEMENT SYSTEM.
E. ELECTRICAL CONTRACTOR SHALL VERIFY THE PROPER
MOUNTING HEIGHT OF THE EMERGENCY FIXTURES WITH
THE LOCAL FIRE MARSHALL PRIOR TO INSTALLATION.
F. REFER TO DRAWING E2.0 FOR ROOM/AREA NAMES.
G. SEE LIGHT FIXTURE SCHEDULE ON DRAWING E4.0.
H. ALL BRANCH CIRCUITS MORE THAN 100 FEET IN LENGTH
FOR 120 VOLT CIRCUITS AND 200 FEET FOR 277 VOLT
CIRCUITS SHALL BE MINIMUM #10 AWG.
I. REFER TO THIS DRAWING FOR EXACT LOCATION AND
MOUNTING HEIGHT OF ALL LIGHT FIXTURES. COORDINATE
WITH ARCHITECTS REFLECTED CEILING PLAN PRIOR TO
ROUGH-IN.
J. ALL CONDUITS RUN IN EXPOSED CEILING AREAS SHALL
BE RUN WITH STRUCTURE TIGHT TO UNDER SIDE OF ROOF
DECKING IN ACCORDANCE WITH N.E.C. ARTICLE 300.4(E).
K. PROVIDE ADDITIONAL EXIT SIGNS TO MATCH EXISTING
IN PROJECT AREA AS DIRECTED BY THE LOCAL AUTHORITY
'XRN'
'XRN' 'XRN'
'XRN' 'XRN'
'XRN'
\pxqc;ALL LIGHTING FIXTURES SHOWN ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE
4
'XRN'
GFLW
4
'XRN'
GFLW
4
'XRN'
GFLW
4
'XRN'
GFLW
4
'XRN'
GFLW 4
'XRN'
GFLW 4
'XRN'
GFLW
4
'XRN'
GFLW
2
'XRW'
2
'XRW'
3
'XRN'
3
'XRN'
2
'XRW'
3
'XRN'
3
'XRN'
3
'XRN'
2
'XRW'
4
'XRN'
DWW
4
'XRN'
DWW2
'XRW'
4
'XRN'
DWW
2
'XRW'
4
'XRN'
DWW
2
'XRW'
4
'XRN'
DWW
4
'XRN'
DWW
2
'XRW'
2
'XRW'
'XRN' 3
4
'XRN'
GFLW
3
'XRN'
4
'XRN'
DWW
1
6
'XRW'
AEM/
A1-3a
A/A1-3 A/A1-3
AEM/
A1-3a
A/A1-3
6
'XRW'
(TYP.)
9
LG1EM/A1-3a,b
b M2
LG1/A1-3b
LG1/A1-3c
LG1/A1-3c
c M2
S2/AA1-1a
LG1EM/A1-3a,d
d M2
LG1/A1-3d LG1/A1-3d
6
'XRW'
6
'XRW'
6
'XRW'
S2/AA1-1a
S2/AA1-1a
J J
R5/'CTX'a
12
8
11
12
FR/'CTX'
'XRW'
R5/'CTX'a
J J
R5/'CTX'a
12
8
11
12
FR/'CTX'
'XRW'
R5/'CTX'a
4
'XRN'
GFLW
Mar 26, 2021 - 17:36:33 DWG Name: D:\Jobs\MCG\Dick's Sporting Goods\IN Carmel\Remodel\01-Bid Permit\12810B_E1.0,1.1.dwg Updated By: rvan
E1.0
FIRST FLOOR
LIGHTING PLAN
PJN
CONTRACTOR MUST VERIFY
DIMENSIONS ALL CLEARANCES IN AND FIELD
Drawn By:
Project No.:
Date Issue
SPORTING GOODS
Design and construction documents as
instruments of service are given in
confidence and remain the property of
MCG Architects. The use of this design
and these construction documents for
purposes other than the specific project
named herein is strictly prohibited
without expressed written consent of
MCG Architects, Incorporated.
STORE # 183
21042.10
C MCG ARCHITECTS 2021
ALL RIGHTS RESERVED
**With exception of the National Account Vendors that DSG is purchasing directly from as noted on the vendor
matrix, all work, materials, and systems shown in these plans and specifications is the sole responsibility of the
General Contractor to purchase and install complete as shown and referenced. The General Contractor is required
to coordinate, schedule and supervise all National Account Vendors as well as their subcontractors. The Tenant
(Dick's Sporting Goods) has no scope of work and/or responsibility shown in these plans and/or specifications.**
25001 Emery Road, Suite #200
Warrensville Heights, Ohio 44128
Phone: 216-292-4696
Fax: 216-292-5874
Email: mail@mchenryassociates.com
Issued for
Bid-Permit
03-26-21
T F
\pxql;216.520.1551
\pxql;216.520.1567
03-26-21
SM
CLAY TERRACE
14350 CLAY TERRACE BLVD.
CARMEL, IN 46032
05/11/21