HomeMy WebLinkAboutC109C803
JOB#: SCB.002
DATE: 11/06/20
DRAWN BY: RCW
(317) 251-1738 (FAX) 251-1923
INDIANAPOLIS, INDIANA 46220
6555 CARROLLTON AVENUE
www.rw-engineering.com
CIVIL ENGINEERS - LAND SURVEYORS - DEVELOPMENT CONSULTANTS
CONSTRUCTION DETAILS
11585 N. PENNSYLVANIA STREET
PENNWOOD PROFESSIONAL
CARMEL, INDIANA
17
OFFICE PARK
MANHOLE & INLETS
STORM SEWER
Date: 01/06/15 Aqua-Swirl Concentrator Model AS-3 BYP PCS Standard Detail
Scale:
Document:
Drawn By:
AS-3 PCS STD
1:20
JCW
U.S. Patent No. 6524473 and other Patent Pending
™
Phone (888) 344-9044 Fax (423) 826-2112
www.aquashieldinc.com
STORMWATER TREATMENT SOLUTIONS
Plan View
Outlet
Internal Baffles
Octagonal Base Plate
A
Pipe coupling
by Contractor.
12" [305 mm]
long Stub-out
by Manufacturer.
Ø42"
[Ø1067 mm]
54"
[1372 mm]
STORMWATER TREATMENT SOLUTIONS
Phone (888) 344-9044
www.aquashieldinc.com
™
Slide riser over top ring
and bolt in 4 places
Riser
68"
[1727 mm]
104"
[2642 mm]
Gravel Backfill shall extend at
least 3.5 feet outward from
Swirl Concentrator and for the
full height of the Swirl
Concentrator (including riser)
extending laterally to
undisturbed soils. (See MH
Detail Below)
Swirl Inlet/Outlet
Bedding
Undisturbed Soil
Backfill
6"
[152 mm]
18"
[457 mm]
Section A-A
Grade (Rim)
30"
[762 mm]
Rim elevations to match finished
grade.
Manhole Frame and
Cover by Manufacturer.
(See Details) 5"
[127 mm] MH Frame
Varies
Varies
Aqua-Swirl Polymer Coated Steel (PCS)
Stormwater Treatment System
4 1/2"
[114 mm]
Concrete
Gravel Backfill Place small amount of
concrete to support and
level manhole frame. DO
NOT allow manhole frame
to rest upon HDPE riser.
Soil
1/2"
[13 mm]
1/2"
[13 mm]
Manhole Frame & Cover Detail
NTS
For Non-Traffic Areas Only
Cover
Frame
Riser
Concrete
Gravel Backfill
Soil
1/2"
[13 mm]
Bollards shall be placed around access
riser(s) in non-traffic areas to prevent
inadvertent loading by maintenance
vehicles.
Inlet
54"
[1372 mm]
A
21"
[533 mm] PCS Max
Internal
Baffles
2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343
* Please see accompanied Aqua-Swirl
specification notes.
* See Site Plan for actual system orientation.
** Orientation may vary from 90°, 180°, or
custom angles to meet site conditions.
Note: As an alternative, 42-inch OD, HS-20/25
rated precast concrete rings may be substituted.
14-inch thickness must be maintained.
180°**
™
Phone (888) 344-9044 Fax (423) 826-2112
2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343
STORMWATER TREATMENT SOLUTIONS
www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-4 BYP PCS Standard Detail
AS-4 PCS STD
01/06/15
Scale:
Drawn By:
Document:
Date:
JCW
1:20
U.S. Patent No. 6524473 and other Patent Pending
27"
[686 mm] PCS Max
A
66"
[1676 mm]
66"
[1676 mm]
Outlet
Pipe coupling
by Contractor.
12" [305 mm]
long Stub-out
by Manufacturer.
Octagonal Base Plate
STORMWATER TREATMENT SOLUTIONS
Phone (888) 344-9044
www.aquashieldinc.com
™
Internal
Baffles
Slide riser over top ring
Riser and bolt in 4 places
68"
[1727 mm]
104"
[2642 mm]
to
107"
[2718 mm]
Swirl Inlet/Outlet
Bedding
Undisturbed Soil
Backfill
6"
[152 mm]
18"
[457 mm]
Section A-A
Plan View
Grade (Rim)
30"
[762 mm]
Rim elevations to match finished
grade.
Manhole Frame and
Cover by Manufacturer.
(See Details) 5"
[127 mm] MH Frame
Varies
Varies
Gravel Backfill shall extend at
least 3.5 feet outward from
Swirl Concentrator and for the
full height of the Swirl
Concentrator (including riser)
extending laterally to
undisturbed soils. (See MH
Detail Below)
4 1/2"
[114 mm]
Concrete
Gravel Backfill Place small amount of
concrete to support and
level manhole frame. DO
NOT allow manhole frame
to rest upon HDPE riser.
Soil
1/2"
[13 mm]
1/2"
[13 mm]
Manhole Frame & Cover Detail
NTS
For Non-Traffic Areas Only
Cover
Frame
Riser
Concrete
Gravel Backfill
Soil
1/2"
[13 mm]
Bollards shall be placed around access
riser(s) in non-traffic areas to prevent
inadvertent loading by maintenance
vehicles.
Aqua-Swirl Polymer Coated Steel (PCS)
Stormwater Treatment System
Ø54"
[Ø1372 mm]
A
Inlet
Internal Baffles
* Please see accompanied Aqua-Swirl
specification notes.
* See Site Plan for actual system orientation.
** Orientation may vary from 90°, 180°, or
custom angles to meet site conditions.
Note: As an alternative, 42-inch OD, HS-20/25
rated precast concrete rings may be substituted.
14-inch thickness must be maintained.
180°**
05/13/21