Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center 352 South County Road 300 E Danville, IN 46122 317-745-9984 These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the need for a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement). Please insure measurements of the foundation match those provided at the time of design. Builder is responsible to place load bearing members in load path. Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber Franklin Kevin Beher Pyatt Builders TG92 Rev. By Date Comments Drawn By: DW Checked By: Date: CM 04/05/2021 Chelsea 24298 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record. Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. Spacing Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H101 7 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No Products PlotID Length Product Plies Net Qty FJ201 22' 0" 11 7/8" TJI 110 joist 1 2 FJ202 18' 0" 11 7/8" TJI 110 joist 1 4 FJ203 16' 0" 11 7/8" TJI 110 joist 1 3 FJ204 12' 0" 11 7/8" TJI 110 joist 1 2 FJ205 10' 0" 11 7/8" TJI 110 joist 1 1 FJ206 4' 0" 11 7/8" TJI 110 joist 1 2 FJ207 36' 0" 11 7/8" TJI 360 joist 1 2 FJ208 20' 0" 11 7/8" TJI 360 joist 1 2 FJ209 18' 0" 11 7/8" TJI 360 joist 1 9 FJ210 16' 0" 11 7/8" TJI 360 joist 1 4 FJ211 22' 0" 11 7/8" TJI 560 joist 1 5 FJ212 18' 0" 11 7/8" TJI 560 joist 1 1 BM201 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 BM202 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 2 2 BM203 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca201 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 12 Accessories PlotID Length Product Plies Net Qty 1' 0" 5/8" or 3/4" Backer Blocks 1 14 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 39 Blocking PlotID Length Product Plies Net Qty Bk201 2' 0" 11 7/8" TJI 110 joist 1 21 LEVEL NOTES Current Date: 4/5/2021 File Name: tg92_24298.jvl Level Name: Second Floor System Building Code - Design Methodology: IBC 2006 Members with Design Overridden: TJ-Pro Rating (Weighted Average): 43 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 31, joist = FJ207(i3382) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 62, joist = FJ202(i3363) FLOOR Floor Container: FC2 Use/Occupancy: ResidentialLivingAreas Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Operator Added Additional Loads Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average: 43 Directly Applied Ceiling: Gypsum 1/2" Decking Attachment: Glue and Nail Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF Perpendicular Partition: No Strapping at max 8' o.c.: None Blocking at max 8' o.c.: No Poured Flooring: No E1 B4 B4 B1 B1 A3 A3 A3 A3 A3 A3 A3 H2 H2 H2 H2 H2 H2 B1 B1 PBO1 BM202 PBO2 BBO4 PBO3 BBO5 BBO8 BBO10 BM201 BM203 FJ204 FJ201 FJ201 FJ202 FJ202 FJ202 FJ203 FJ203 FJ205 FJ202 FJ209 FJ209 FJ209 FJ209 FJ209 FJ209 FJ209 FJ212 FJ209 FJ210 FJ210 FJ210 FJ210 FJ207 FJ207 FJ209 Ca201 Ca201 Ca201 Ca201 Ca201 Ca201 Ca201 Ca201 Ca201 Bk201 VO1 VO2 VO3 VO4 FJ211 Bk201 FJ211 FJ208 Bk201 FJ208 1' 0" 2' 0" 1' 0" 1' 0" 2' 0" FJ206 Ca201 Ca201 FJ206 H101 H101 FJ204 Bk201 8 7/8" FJ203 H101 H101 H101 H101 10 7/8" 1' 1 1/8" 1' 3 1/8" Bk201 Ca201 Ca201 5' 9 15/16" 1' 1 3/8" 11" 1' 6 9/16" 1' 7 1/2" 11 1/4" 6' 0" 5' 7" 2' 4 1/2" FJ211 FJ211 FJ211 H101 Steel Beam An additional 8 PSF area dead load has been added to account for tile load in the MBA on this floor. Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior to construction. There are different joist series of the same depth specified on this floor system. Verify when installing that the proper TJI® joists are used in the appropriate area. (4) 2x6 Beam Jacks 05/03/21