HomeMy WebLinkAboutM002.0Indianapolis Design Center
352 South County Road 300 E
Danville, IN 46122
317-745-9984
These placement plans have been prepared with the specifications of TrussJoist
products based on project information provided. This service is solely intended
for product application assurance; and, is not intended to circumvent the need
for a design professional as determined by the building codes. The designer
of record and/or builder/framer is responsible to assure these drawings are
compatible with the overall project. These documents are not intended to replace
the building plan (which should be used to determine bearing placement).
Please insure measurements of the foundation match those provided at the time
of design. Builder is responsible to place load bearing members in load path.
Architectural Drawings Prepared By: Structural Drawings Prepared By:
84 Lumber Franklin
Kevin Beher
Pyatt Builders
TG93
Rev. By Date Comments
Drawn By:
DW
Checked By: Date:
CM 04/07/2021
Chelsea
24316
Sheet
1 of 1
Main Floor System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified.
11 7/8" TJI Joists
24" O.C. Spacing
Framing Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes
H2 6 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No
H3 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No
H4 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes
Products
PlotID Length Product Plies Net Qty
FJ1 18' 0" 11 7/8" TJI 110 joist 1 6
FJ2 16' 0" 11 7/8" TJI 110 joist 1 3
FJ3 12' 0" 11 7/8" TJI 110 joist 1 4
FJ4 10' 0" 11 7/8" TJI 110 joist 1 1
FJ5 4' 0" 11 7/8" TJI 110 joist 1 8
FJ6 36' 0" 11 7/8" TJI 360 joist 1 2
FJ7 26' 0" 11 7/8" TJI 360 joist 1 2
FJ8 18' 0" 11 7/8" TJI 360 joist 1 9
FJ9 16' 0" 11 7/8" TJI 360 joist 1 2
FJ10 22' 0" 11 7/8" TJI 560 joist 1 4
FJ11 16' 0" 11 7/8" TJI 560 joist 1 1
BM1 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2
BM2 20' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2
BM3 6' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 2
BM4 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6
BM5 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
Ca1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 13
Accessories
PlotID Length Product Plies Net Qty
9 1/8" 7/8" x 2 5/16" Web Stiffeners 1 6
1' 0" 5/8" or 3/4" Backer Blocks 1 14
9 1/8" 5/8" x 2 5/16" Web Stiffeners 1 2
1' 0" 7/8" or 1" net Backer Blocks 1 4
23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 40
Blocking
PlotID Length Product Plies Net Qty
Bk1 2' 0" 11 7/8" TJI 110 joist 1 17
LEVEL NOTES
Current Date: 4/7/2021
File Name: tg93_24316.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2006
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 45
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 33, joist = FJ7(i2834)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 62, joist = FJ1(i2789)
FLOOR
Floor Container: FC1
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 45
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
11 7/8" TJI Joists
24" O.C. Spacing
B1
A3
A3
A3
A3
A3
A3
A3
A3
H2
H2
H2
H2
H2
H2
B3W
B1
B4
E1
BBO6
BBO5
BM4
BM4
BM3
BM2
Steel Beam
BM4
(4) 2x6 Beam Jacks
BM1
BBO12
BBO13
PBO2 PBO3
FJ4
FJ6
FJ10
FJ10
FJ10
FJ10
FJ6
FJ8
FJ8
FJ8
FJ8
FJ8
FJ8
FJ8
FJ8
FJ8
FJ1
FJ1
FJ2
FJ2
FJ1
FJ1
FJ1
FJ3
FJ3
FJ3
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Ca1
Bk1
FJ5
FJ5
FJ5
FJ5
FJ5
FJ1
FJ3
FJ5
H2
H2
Bk1
4 7/8"
VO1
VO2
VO3
VO4
H2 H2
1' 0"
1' 9 1/8"
1' 2 7/8"
FJ5
FJ5
FJ7
FJ7
BM5
Ca1
H3
H3
H3
H3
H3
H2
H4
H2
FJ9
FJ11
FJ9
FJ2
Bk1
6' 0"
5' 7"
1' 0" 2' 0" 1' 0"
1' 1 1/4"
9"
5' 2 1/2" 2' 0" 8' 8 1/2"
1' 0 5/16"
5' 9 7/8"
2' 4 1/2"
8 9/16"
H1
H1
Flush beam depth greater than floor joist depth. Verify
all loading and framing conditions prior to construction.
An additional 8 PSF area dead load has been added
to account for tile load in the MBA on this floor.
There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
05/03/21