Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center 352 South County Road 300 E Danville, IN 46122 317-745-9984 These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intended for product application assurance; and, is not intended to circumvent the need for a design professional as determined by the building codes. The designer of record and/or builder/framer is responsible to assure these drawings are compatible with the overall project. These documents are not intended to replace the building plan (which should be used to determine bearing placement). Please insure measurements of the foundation match those provided at the time of design. Builder is responsible to place load bearing members in load path. Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber Franklin Kevin Beher Pyatt Builders TG93 Rev. By Date Comments Drawn By: DW Checked By: Date: CM 04/07/2021 Chelsea 24316 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record. Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. Spacing Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 2 Simpson MIU2.37/11 Designed 20- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes H2 6 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No H3 5 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - No No No H4 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes Products PlotID Length Product Plies Net Qty FJ1 18' 0" 11 7/8" TJI 110 joist 1 6 FJ2 16' 0" 11 7/8" TJI 110 joist 1 3 FJ3 12' 0" 11 7/8" TJI 110 joist 1 4 FJ4 10' 0" 11 7/8" TJI 110 joist 1 1 FJ5 4' 0" 11 7/8" TJI 110 joist 1 8 FJ6 36' 0" 11 7/8" TJI 360 joist 1 2 FJ7 26' 0" 11 7/8" TJI 360 joist 1 2 FJ8 18' 0" 11 7/8" TJI 360 joist 1 9 FJ9 16' 0" 11 7/8" TJI 360 joist 1 2 FJ10 22' 0" 11 7/8" TJI 560 joist 1 4 FJ11 16' 0" 11 7/8" TJI 560 joist 1 1 BM1 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 BM2 20' 0" 1 3/4" x 11 7/8" 2.0E Microllam LVL 2 2 BM3 6' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 2 BM4 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6 BM5 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 13 Accessories PlotID Length Product Plies Net Qty 9 1/8" 7/8" x 2 5/16" Web Stiffeners 1 6 1' 0" 5/8" or 3/4" Backer Blocks 1 14 9 1/8" 5/8" x 2 5/16" Web Stiffeners 1 2 1' 0" 7/8" or 1" net Backer Blocks 1 4 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 40 Blocking PlotID Length Product Plies Net Qty Bk1 2' 0" 11 7/8" TJI 110 joist 1 17 LEVEL NOTES Current Date: 4/7/2021 File Name: tg93_24316.jvl Level Name: Second Floor System Building Code - Design Methodology: IBC 2006 Members with Design Overridden: TJ-Pro Rating (Weighted Average): 45 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 33, joist = FJ7(i2834) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 62, joist = FJ1(i2789) FLOOR Floor Container: FC1 Use/Occupancy: ResidentialLivingAreas Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Operator Added Additional Loads Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average: 45 Directly Applied Ceiling: Gypsum 1/2" Decking Attachment: Glue and Nail Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF Perpendicular Partition: No Strapping at max 8' o.c.: None Blocking at max 8' o.c.: No Poured Flooring: No 11 7/8" TJI Joists 24" O.C. Spacing B1 A3 A3 A3 A3 A3 A3 A3 A3 H2 H2 H2 H2 H2 H2 B3W B1 B4 E1 BBO6 BBO5 BM4 BM4 BM3 BM2 Steel Beam BM4 (4) 2x6 Beam Jacks BM1 BBO12 BBO13 PBO2 PBO3 FJ4 FJ6 FJ10 FJ10 FJ10 FJ10 FJ6 FJ8 FJ8 FJ8 FJ8 FJ8 FJ8 FJ8 FJ8 FJ8 FJ1 FJ1 FJ2 FJ2 FJ1 FJ1 FJ1 FJ3 FJ3 FJ3 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Ca1 Bk1 FJ5 FJ5 FJ5 FJ5 FJ5 FJ1 FJ3 FJ5 H2 H2 Bk1 4 7/8" VO1 VO2 VO3 VO4 H2 H2 1' 0" 1' 9 1/8" 1' 2 7/8" FJ5 FJ5 FJ7 FJ7 BM5 Ca1 H3 H3 H3 H3 H3 H2 H4 H2 FJ9 FJ11 FJ9 FJ2 Bk1 6' 0" 5' 7" 1' 0" 2' 0" 1' 0" 1' 1 1/4" 9" 5' 2 1/2" 2' 0" 8' 8 1/2" 1' 0 5/16" 5' 9 7/8" 2' 4 1/2" 8 9/16" H1 H1 Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior to construction. An additional 8 PSF area dead load has been added to account for tile load in the MBA on this floor. There are different joist series of the same depth specified on this floor system. Verify when installing that the proper TJI® joists are used in the appropriate area. 05/03/21