Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
M003.0
16023 Swingley Ridge Rd Chesterfield, MO 63017 314-434-1200 MiTek USA, Inc. Re: The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by 84 Components - 0783. April 23,2021 Liu, Xuegang Pages or sheets covered by this seal: I45792423 thru I45792452 My license renewal date for the state of Indiana is July 31, 2022. TG139 TG139 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A01 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792423 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:49:56 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-joif6Wh2UE3Tqa35BqVanB8LtqoQwGyBsYgRb8zO65v Scale = 1:62.3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 3x6 5x6 3x6 3x6 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A02 Truss Type Common Qty 2 Ply 1 TG139 Job Reference (optional) I45792424 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:49:58 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-fBqPXBjI0sJA4uDUIFX2scDbMdJmO7OUKs9Yf1zO65t Scale = 1:62.8 1 2 3 4 5 6 7 8 9 10 11 16 15 14 23 24 25 13 26 12 3x6 5x6 3x6 5x6 3x8 MT18HS 4x8 3x4 3x4 1.5x4 3x4 3x4 1.5x4 3x8 MT18HS 5x6 9-3-7 9-3-7 17-7-0 8-3-9 25-10-9 8-3-9 35-2-0 9-3-7 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A03 Truss Type Common Qty 1 Ply 1 TG139 Job Reference (optional) I45792425 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:49:59 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-8NOnlXkxn9S1h2ngsz3HPpmm61e?7addYWv5BTzO65s Scale = 1:63.3 1 2 3 4 5 6 7 8 9 10 15 14 13 22 23 24 12 25 11 5x6 3x6 5x6 3x6 3x8 MT18HS 5x6 3x4 3x4 1.5x4 4x8 3x4 3x4 1.5x4 3x8 MT18HS 9-3-7 9-3-7 17-7-0 8-3-9 25-10-9 8-3-9 35-2-0 9-3-7 5-11-9 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A04 Truss Type Roof Special Qty 2 Ply 1 TG139 Job Reference (optional) I45792426 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:00 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-cZx9ytkZYTauJBMtQgaWx1Ix6R0Gs_xnnAefkvzO65r Scale = 1:61.7 1 2 3 4 5 6 7 8 9 10 11 12 18 17 16 15 14 13 5x6 3x6 5x6 3x6 3x4 2x4 2x4 3x4 6x8 5x6 3x4 6x8 6x8 3x4 6x8 1.5x4 1.5x4 9-3-7 9-3-7 16-2-0 6-10-9 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A05 Truss Type Roof Special Qty 1 Ply 1 TG139 Job Reference (optional) I45792427 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:02 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-Yy3wNZmp44qcZVWFX5c_1SOH_EitKuP4FT7loozO65p Scale = 1:62.2 1 2 3 4 5 6 7 8 9 10 11 17 16 15 14 13 12 5x6 3x6 3x6 5x6 3x4 2x4 2x4 3x4 6x8 6x8 3x4 5x6 6x8 6x8 3x4 1.5x4 1.5x4 9-3-7 9-3-7 16-2-0 6-10-9 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A06 Truss Type Common Qty 7 Ply 1 TG139 Job Reference (optional) I45792428 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:03 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-08dIavnRrOyTAf5R5o7DZfwRUe053OcDT7tJKEzO65o Scale = 1:62.2 1 2 3 4 5 6 7 8 9 14 13 12 21 22 23 11 24 10 5x6 3x6 3x6 3x8 MT18HS 5x6 3x4 3x4 5x6 1.5x4 4x8 3x4 3x4 1.5x4 3x8 MT18HS 9-3-7 9-3-7 17-7-0 8-3-9 25-10-9 8-3-9 35-2-0 9-3-7 5-11-9 5-11-9 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss A07 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792429 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:06 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-QjJQDwpK7JK216q0mxhwBIY2bsCjGnRf955zxZzO65l Scale = 1:61.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 3x6 3x6 3x6 5x6 3x6 5x6 5x6 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss B01 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792430 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:08 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-N6QBdcrafwamHQzPuMjOGjeNkfqRki0ydPa40RzO65j Scale = 1:55.9 1 2 3 4 5 7 9 11 13 14 15 16 17 18 19 20 21 22 23 6 8 10 12 33 32 31 30 29 28 27 26 25 24 4x4 3x6 4x4 3x6 4x4 4x6 4x4 3x4 5x6 7-7-8 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss B02 Truss Type Common Qty 3 Ply 1 TG139 Job Reference (optional) I45792431 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:09 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-rI_ZryrCQEiduaYbS3EdpwAX2301T6y6s3KdYuzO65i Scale = 1:48.9 1 2 3 4 5 6 7 8 9 10 4x8 4x4 6x10 4x6 1.5x4 1.5x4 4x8 4x4 11-3-8 11-3-8 22-7-0 11-3-8 -1-0-0 1-0-0 5-9-8 5-9-8 11-3-8 5-6-0 16-9-8 5-6-0 22-7-0 5-9-8 23-7-0 1-0-0 0-8-11 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss B03 Truss Type COMMON GIRDER Qty 1 Ply 2 TG139 Job Reference (optional) I45792432 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:12 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-FtgiT_u4j94Bl1HA7BoKQZos5G7pgNMYY1YH9DzO65f Scale = 1:50.2 1 2 3 4 5 6 7 8 9 14 13 12 11 10 23 24 25 26 27 28 29 30 31 32 8x8 4x6 5x9 8x8 4x6 10x10 4x4 8x8 4x6 4x8 4x4 8x8 4x6 4x8 3-10-3 3-10-3 7-6-14 3-8-10 11-3-8 3-8-10 15-0-2 3-8-10 18-8-13 3-8-10 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss B03 Truss Type COMMON GIRDER Qty 1 Ply 2 TG139 Job Reference (optional) I45792432 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:12 2021 Page 2 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-FtgiT_u4j94Bl1HA7BoKQZos5G7pgNMYY1YH9DzO65f NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1526 lb down and 116 lb up at 0-6-4, 1386 lb down and 120 lb up at 2-6-4, 1386 lb down and 120 lb up at 4-6-4, 1387 lb down and 121 lb up at 6-6-4, 1522 lb down and 121 lb up at 8-6-4, 1522 lb down and 121 lb up at 10-6-4, 1522 lb down and 121 lb up at 12-6-4, 1522 lb down and 121 lb up at 14-6-4, 1522 lb down and 121 lb up at 16-6-4, and 1522 lb down and 121 lb up at 18-6-4, and 1522 lb down and 121 lb up at 20-6-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-5=-60, 5-9=-60, 15-19=-20 Concentrated Loads (lb) Vert: 10=-1387(F) 23=-1391(F) 24=-1386(F) 25=-1386(F) 26=-1387(F) 27=-1387(F) 28=-1387(F) 29=-1387(F) 30=-1387(F) 31=-1387(F) 32=-1387(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss C01 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792433 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:13 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-j3E4hKujUTC2NBsMhvJZzmLFvgbVP_QhmhIrhfzO65e Scale = 1:38.4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 4x4 3x4 4x8 5x6 4x8 3x4 20-8-0 20-8-0 -1-0-0 1-0-0 10-4-0 10-4-0 20-8-0 10-4-0 21-8-0 1-0-0 0-6-8 5-8-8 0-6-8 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss C02 Truss Type Common Qty 3 Ply 1 TG139 Job Reference (optional) I45792434 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:15 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-gSLq6?wz04TmcV0loKL12BQZYU5XtrT_E?nxmXzO65c Scale = 1:38.1 1 2 3 4 5 6 7 8 15 16 4x6 5x9 4x4 1.5x4 1.5x4 4x6 10-4-0 10-4-0 20-8-0 10-4-0 -1-0-0 1-0-0 6-6-4 6-6-4 10-4-0 3-9-12 14-1-12 3-9-12 20-8-0 6-6-4 21-8-0 1-0-0 0-6-8 5-8-8 0-6-8 6.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-5], [6:Edge,0-1-5], [8:0-4-8,0-3-4] LOADING (psf) TCLL 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss D01 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792435 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:16 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-8evCJLxbnObdEfbxM1sGbPzmyudIcKy8TfWVI_zO65b Scale = 1:42.5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 28 27 26 25 24 23 22 21 20 19 18 4x4 3x6 4x4 5x6 3x6 4x4 17-8-0 17-8-0 -1-0-0 1-0-0 8-10-0 8-10-0 17-8-0 8-10-0 18-8-0 1-0-0 0-8-11 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss D02 Truss Type COMMON Qty 2 Ply 1 TG139 Job Reference (optional) I45792436 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:18 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-411zk1yrI?rLTykKTSukgq24zhAc4DOQwz?bMszO65Z Scale = 1:41.7 1 2 3 4 5 6 7 8 9 10 5x6 4x4 4x4 5x9 1.5x4 1.5x4 5x6 4x4 8-10-0 8-10-0 17-8-0 8-10-0 -1-0-0 1-0-0 5-7-9 5-7-9 8-10-0 3-2-7 12-0-7 3-2-7 17-8-0 5-7-9 18-8-0 1-0-0 0-8-11 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss D03 Truss Type Common Girder Qty 1 Ply 3 TG139 Job Reference (optional) I45792437 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:19 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-YDbLxNzU3JzC56JW19QzD1bDM5Yspaya9dl9vJzO65Y Scale = 1:40.7 1 2 3 4 5 6 9 8 7 16 17 18 19 20 21 22 23 8x8 8x8 8x8 4x6 4x6 4x8 4x6 4x8 4-10-2 4-10-2 8-10-0 3-11-14 12-9-14 3-11-14 17-8-0 4-10-2 -1-0-0 1-0-0 4-10-2 4-10-2 8-10-0 3-11-14 12-9-14 3-11-14 17-8-0 4-10-2 0-8-11 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss D03 Truss Type Common Girder Qty 1 Ply 3 TG139 Job Reference (optional) I45792437 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:20 2021 Page 2 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-0Q9j9j_6qc53jGujbtxClF7O6Vu5Y1CjNHUiRlzO65X LOAD CASE(S) Standard 1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (plf) Vert: 1-4=-60, 4-6=-60, 10-13=-20 Concentrated Loads (lb) Vert: 16=-1387(F) 17=-1387(F) 18=-1387(F) 19=-1387(F) 20=-1387(F) 21=-1387(F) 22=-1387(F) 23=-1387(F) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss E01 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792438 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:21 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-Ucj5M3?kbwDwKQTv9aSRISgb?vKaHcptcxEGzBzO65W Scale = 1:27.0 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 3x6 4x4 3x6 10-7-0 10-7-0 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-11 4-3-0 0-8-11 8.00 12 Plate Offsets (X,Y)-- [12:0-3-12,0-1-8], [20:0-3-12,0-1-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss E02 Truss Type Common Qty 2 Ply 1 TG139 Job Reference (optional) I45792439 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:22 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-zoGUaP?MMELnya25iIzgqgDlvIdW03d0rbzpVezO65V Scale = 1:27.2 1 2 3 4 5 6 7 8 3x6 4x4 3x6 4x4 1.5x4 4x4 5-3-8 5-3-8 10-7-0 5-3-8 -1-0-0 1-0-0 5-3-8 5-3-8 10-7-0 5-3-8 11-7-0 1-0-0 0-8-11 4-3-0 0-8-11 8.00 12 Plate Offsets (X,Y)-- [2:0-2-4,0-0-3], [6:0-3-3,0-0-3] LOADING (psf) TCLL (Roof Snow=20.0) TCDL 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss J01 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792440 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:23 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-R_qsnk0_7XTdakdHG?UvNtlxbi?zlV2A4FjM24zO65U Scale = 1:14.2 1 2 3 4 6 5 1.5x4 2x4 1.5x4 1.5x4 1.5x4 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-14 2-3-6 4.50 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss J02 Truss Type Monopitch Qty 8 Ply 1 TG139 Job Reference (optional) I45792441 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:23 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-R_qsnk0_7XTdakdHG?UvNtludiy8lVhA4FjM24zO65U Scale = 1:14.2 1 2 3 4 1.5x4 3x4 1.5x4 -1-0-0 1-0-0 5-0-0 5-0-0 0-4-14 2-3-6 1-11-14 0-3-8 2-3-6 4.50 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss J03 Truss Type Monopitch Qty 5 Ply 1 TG139 Job Reference (optional) I45792442 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:24 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-vBOE_41curbUBtCUqj?8w5I5N6I4UtLJIuSwaWzO65T Scale = 1:29.0 1 2 3 4 7 6 5 8 9 10 5x6 4x4 3x4 4x4 3x6 5x6 3x6 5-7-2 5-7-2 11-2-4 5-7-2 -1-1-12 1-1-12 5-7-2 5-7-2 11-2-4 5-7-2 1-1-5 0-7-10 5-3-2 0-3-8 0-10-12 5-3-2 4.50 12 Plate Offsets (X,Y)-- [7:0-1-7,0-2-8] LOADING (psf) TCLL (Roof Snow=20.0) 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss J04 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792443 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:25 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-NNycCQ2Ef9jLp1ngOQWNSIrHpWgfDPcSXYCT6yzO65S Scale = 1:31.4 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 21 22 11 2x4 4x4 4x6 3x6 11-2-4 11-2-4 -1-1-12 1-1-12 11-2-4 11-2-4 0-3-12 0-7-10 5-3-2 0-9-1 0-9-1 5-3-2 4.50 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss J05 Truss Type GABLE Qty 1 Ply 1 TG139 Job Reference (optional) I45792444 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:26 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-rZW_Pm3tQSrCRBMsx72c?WNSAw0vys9cmCx1ePzO65R Scale = 1:32.3 1 2 3 4 5 6 11 10 9 8 7 12 3x4 3x4 4x6 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 3x4 -1-1-12 1-1-12 5-3-4 5-3-4 1-5-1 4-11-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss J06 Truss Type Monopitch Qty 4 Ply 1 TG139 Job Reference (optional) I45792445 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:27 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-Jm4Nd63VBmz32Lw3VrZrXjwd?JMNhI8l_shaBrzO65Q Scale = 1:28.8 1 2 3 5 4 6 7 8 5x6 3x4 2x4 3x4 3x4 5-3-4 5-3-4 -1-1-12 1-1-12 5-3-4 5-3-4 1-6-1 0-7-15 4-11-4 0-3-8 0-10-12 4-11-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V01 Truss Type Valley Qty 2 Ply 1 TG139 Job Reference (optional) I45792446 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:28 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-nyelqS47y45wgVVF3Y444xTq2jjuQmwvDWQ7jHzO65P Scale = 1:7.7 1 2 3 2x4 3x4 2x4 0-0-6 0-0-6 3-0-0 2-11-10 1-6-0 1-6-0 3-0-0 1-6-0 0-0-4 1-0-0 0-0-4 8.00 12 Plate Offsets (X,Y)-- [2:0-2-0,Edge] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V02 Truss Type Valley Qty 2 Ply 1 TG139 Job Reference (optional) I45792447 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:29 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-F8C72o5ljNDnIf4RdGbJd8?_W73v9Dw2SAAhFkzO65O Scale = 1:14.7 1 2 3 4 2x4 4x4 1.5x4 2x4 0-0-6 0-0-6 6-0-0 5-11-10 3-0-0 3-0-0 6-0-0 3-0-0 0-0-4 2-0-0 0-0-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V03 Truss Type Valley Qty 2 Ply 1 TG139 Job Reference (optional) I45792448 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:30 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-kLlVF86NUhLewofeAz6Y9MY6fXNrugwChqvEnAzO65N Scale = 1:20.2 1 2 3 4 2x4 4x4 2x4 1.5x4 0-0-6 0-0-6 9-0-0 8-11-10 4-6-0 4-6-0 9-0-0 4-6-0 0-0-4 3-0-0 0-0-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V04 Truss Type Valley Qty 2 Ply 1 TG139 Job Reference (optional) I45792449 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:31 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-CXJtSU6?E?UVXyEqkhdniZ5DLxgCd6cLvUfoKczO65M Scale = 1:25.7 1 2 3 4 3x4 4x4 3x4 1.5x4 0-0-6 0-0-6 12-0-0 11-11-10 6-0-0 6-0-0 12-0-0 6-0-0 0-0-4 4-0-0 0-0-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V05 Truss Type Valley Qty 2 Ply 1 TG139 Job Reference (optional) I45792450 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:32 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-gjtGgp7d?IcM96p0IO90EndUzK3HMZrU88OLs2zO65L Scale = 1:31.6 1 2 3 4 5 3x4 8 7 6 4x4 3x4 1.5x4 1.5x4 1.5x4 1.5x4 1.5x4 0-0-6 0-0-6 15-0-0 14-11-10 7-6-0 7-6-0 15-0-0 7-6-0 0-0-4 5-0-0 0-0-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V06 Truss Type Valley Qty 2 Ply 1 TG139 Job Reference (optional) I45792451 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:33 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-8wRet98GmckDnGOCs6gFn_AeekOJ50leNo8uOVzO65K Scale = 1:38.1 1 2 3 4 5 3x4 8 9 7 10 6 4x4 3x4 1.5x4 5x6 1.5x4 1.5x4 1.5x4 0-0-6 0-0-6 18-0-0 17-11-10 9-0-0 9-0-0 18-0-0 9-0-0 0-0-4 6-0-0 0-0-4 8.00 12 Plate Offsets (X,Y)-- [7:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 16023 Swingley Ridge Rd Chesterfield, MO 63017 Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Job TG139 Truss V07 Truss Type Valley Qty 1 Ply 1 TG139 Job Reference (optional) I45792452 84 Components (Franklin), Franklin, IN - 46131, 8.430 s Mar 22 2021 MiTek Industries, Inc. Thu Apr 22 16:50:34 2021 Page 1 ID:N0l3JHUmdsj?3wJct1f8Q6y91Up-c6?05V9uXws4OQzPPpBUKCjpA8kgqSIncStSxxzO65J Scale = 1:44.4 1 2 3 4 5 6 7 13 12 11 10 9 8 3x4 4x4 3x4 3x6 0-0-6 0-0-6 21-0-0 20-11-10 10-6-0 10-6-0 21-0-0 10-6-0 0-0-4 7-0-0 0-0-4 8.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- PRODUCT CODE APPROVALS LATERAL BRACING LOCATION Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. The first dimension is the plate width measured perpendicular to slots. Second dimension is the length parallel to slots. Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated. Failure to Follow Could Cause Property Damage or Personal Injury (Drawings not to scale) © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 edge of truss. / 16 " from outside 1 0 - ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. W4-6 W3-6 W3-7 W2-7 W1-7 C1-8 C7-8 C6-7 C5-6 C4-5 C3-4 C1-2 C2-3 TOP CHORD TOP CHORD 8 7 6 5 4 1 2 3 BOTTOM CHORDS TOP CHORDS BEARING 4 x 4 PLATE SIZE This symbol indicates the required direction of slots in connector plates. / 16 " 1 For 4 x 2 orientation, locate plates 0- 1 " / 4 3 PLATE LOCATION AND ORIENTATION Symbols Numbering System General Safety Notes * Plate location details available in MiTek 20/20 software or upon request. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 6-4-8 WEBS Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. dimensions shown in ft-in-sixteenths Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.16 0.14 0.14 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 7 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 70 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 20-11-4. (lb) - Max Horz 1=-129(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 13, 8 except 12=-107(LC 10), 9=-106(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 7 except 11=372(LC 20), 12=447(LC 17), 13=319(LC 17), 9=447(LC 18), 8=319(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-12=-273/156, 5-9=-273/156 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) All plates are 1.5x4 MT20 unless otherwise indicated. 4) Gable requires continuous bottom chord bearing. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 13, 8 except (jt=lb) 12=107, 9=106. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.21 0.15 0.09 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 56 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 17-11-4. (lb) - Max Horz 1=110(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-124(LC 10), 6=-123(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=330(LC 20), 8=505(LC 17), 6=507(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-314/175, 4-6=-314/174 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=124, 6=123. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.15 0.08 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 5 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 45 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 14-11-4. (lb) - Max Horz 1=91(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 1 except 8=-102(LC 10), 6=-102(LC 11) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=259(LC 1), 8=337(LC 17), 6=337(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-256/146, 4-6=-256/145 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 8=102, 6=102. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.52 0.26 0.07 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=11-11-4, 3=11-11-4, 4=11-11-4 Max Horz 1=71(LC 9) Max Uplift 1=-39(LC 10), 3=-48(LC 11) Max Grav 1=236(LC 1), 3=236(LC 1), 4=410(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-272/62 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.26 0.14 0.03 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 24 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=8-11-4, 3=8-11-4, 4=8-11-4 Max Horz 1=-52(LC 6) Max Uplift 1=-28(LC 10), 3=-35(LC 11) Max Grav 1=172(LC 1), 3=172(LC 1), 4=299(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.10 0.05 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=5-11-4, 3=5-11-4, 4=5-11-4 Max Horz 1=-32(LC 6) Max Uplift 1=-18(LC 10), 3=-22(LC 11) Max Grav 1=108(LC 1), 3=108(LC 1), 4=187(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-P 0.01 0.04 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.00 (loc) - - 3 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 6 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=2-11-4, 3=2-11-4 Max Horz 1=-13(LC 8) Max Uplift 1=-5(LC 10), 3=-5(LC 11) Max Grav 1=81(LC 1), 3=81(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.16 0.12 0.10 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.01 -0.02 -0.00 0.01 (loc) 4-5 4-5 7 4-5 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 25 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 5=0-1-8, 7=0-1-8 Max Horz 5=100(LC 10) Max Uplift 7=-72(LC 10) Max Grav 5=289(LC 1), 7=177(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 5, 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 5, 7. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.17 0.07 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 -0.00 -0.00 (loc) 2 2 7 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 33 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 5-3-4. (lb) - Max Horz 11=140(LC 7) Max Uplift All uplift 100 lb or less at joint(s) 11, 7, 8, 9 except 10=-148(LC 7) Max Grav All reactions 250 lb or less at joint(s) 11, 7, 8, 9, 10 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) Gable requires continuous bottom chord bearing. 6) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 7, 8, 9 except (jt=lb) 10=148. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.14 0.07 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 1 1 19 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 61 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x6 SP DSS *Except* 10-12: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 11-12. REACTIONS. All bearings 11-2-4. (lb) - Max Horz 2=165(LC 11) Max Uplift All uplift 100 lb or less at joint(s) 2, 12, 11, 13, 14, 15, 16, 17, 18, 19 Max Grav All reactions 250 lb or less at joint(s) 2, 12, 11, 13, 14, 15, 16, 17, 18, 19 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 12, 11, 13, 14, 15, 16, 17, 18, 19. 12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 2, 12, 11, 13, 14, 15, 16, 17, 18, 19. 13) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 14) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. April 23,2021 TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.25 0.29 0.36 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.03 -0.05 0.02 0.01 (loc) 6-7 6-7 9 6 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 54 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 *Except* 2-7: 2x6 SP DSS OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 7=0-1-8, 9=0-1-8 Max Horz 7=114(LC 9) Max Uplift 7=-59(LC 8), 9=-79(LC 12) Max Grav 7=575(LC 19), 9=520(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-678/18, 5-8=-26/331, 4-8=-26/331, 2-7=-533/83 BOT CHORD 5-6=-90/591 WEBS 3-5=-600/100, 2-6=0/598, 4-9=-524/80 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 7, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7, 9. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7, 9. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.38 0.27 0.00 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.04 -0.07 0.01 0.02 (loc) 4-7 4-7 2 4-7 l/defl >999 >868 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 15 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied, except end verticals. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 2=0-3-8, 4=0-1-8 Max Horz 2=69(LC 11) Max Uplift 2=-48(LC 8), 4=-28(LC 12) Max Grav 2=362(LC 19), 4=255(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 4. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 CSI. TC BC WB Matrix-P 0.19 0.09 0.04 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.00 (loc) 1 1 5 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 16 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 5=5-0-0, 2=5-0-0, 6=5-0-0 Max Horz 2=68(LC 9) Max Uplift 5=-40(LC 19), 2=-39(LC 8), 6=-49(LC 12) Max Grav 5=10(LC 12), 2=267(LC 19), 6=390(LC 19) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-6=-313/96 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5, 2, 6. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.25 0.23 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.02 -0.03 0.01 (loc) 8-11 8-15 2 l/defl >999 >999 n/a L/d 240 240 n/a PLATES MT20 Weight: 37 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 -t 1-6-0, Right 2x4 SPF No.2 -t 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 2=0-3-8, 6=0-3-8 Max Horz 2=-81(LC 8) Max Uplift 2=-43(LC 10), 6=-43(LC 11) Max Grav 2=483(LC 1), 6=483(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-362/49, 4-6=-362/49 BOT CHORD 2-8=0/301, 6-8=0/301 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-R 0.13 0.02 0.02 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 11 10 12 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 48 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. All bearings 10-7-0. (lb) - Max Horz 20=95(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13 Max Grav All reactions 250 lb or less at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18, 19, 15, 14, 13. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 6-7-5 0-8-11 8.00 12 Plate Offsets (X,Y)-- [2:Edge,0-3-13], [6:0-0-0,0-3-13], [8:0-4-0,0-4-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.27 0.42 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.07 -0.13 0.03 0.04 (loc) 7-8 7-8 6 8-9 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 287 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 WEDGE Left: 2x6 SP No.2 , Right: 2x6 SP No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 6=0-3-8, 2=0-3-8 Max Horz 2=123(LC 28) Max Uplift 6=-505(LC 11), 2=-500(LC 10) Max Grav 6=6580(LC 2), 2=6571(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-8898/666, 3-4=-6455/533, 4-5=-6456/532, 5-6=-8858/673 BOT CHORD 2-9=-570/7306, 8-9=-570/7306, 7-8=-509/7275, 6-7=-509/7275 WEBS 4-8=-517/6847, 5-8=-2569/294, 5-7=-185/2904, 3-8=-2610/285, 3-9=-178/2959 NOTES- 1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 6=505, 2=500. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1522 lb down and 121 lb up at 2-0-12, 1522 lb down and 121 lb up at 4-0-12, 1522 lb down and 121 lb up at 6-0-12, 1522 lb down and 121 lb up at 8-0-12, 1522 lb down and 121 lb up at 10-0-12, 1522 lb down and 121 lb up at 12-0-12, and 1522 lb down and 121 lb up at 14-0-12, and 1387 lb down and 121 lb up at 16-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of Continued others. on page 2 April 23,2021 0-3-8 6-7-5 0-8-11 0-3-8 8.00 12 Plate Offsets (X,Y)-- [10:0-4-8,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.18 0.55 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.08 -0.17 0.01 0.03 (loc) 10-13 10-13 2 10-13 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 69 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 -t 1-6-0, Right 2x4 SPF No.2 -t 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 2=0-3-8, 8=0-3-8 Max Horz 2=-126(LC 8) Max Uplift 2=-61(LC 10), 8=-61(LC 11) Max Grav 2=764(LC 1), 8=764(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-795/77, 4-5=-690/88, 5-6=-690/88, 6-8=-795/77 BOT CHORD 2-10=-62/663, 8-10=-7/662 WEBS 5-10=-46/541 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 0-3-8 6-7-5 0-8-11 0-3-8 8.00 12 Plate Offsets (X,Y)-- [2:0-3-15,0-0-3], [16:0-3-15,0-0-3], [23:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.08 0.03 0.06 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 -0.00 0.00 (loc) 16 16 16 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 97 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 -t 1-6-14, Right 2x4 SPF No.2 -t 1-6-14 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 17-8-0. (lb) - Max Horz 2=-126(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 24, 25, 26, 27, 28, 22, 21, 20, 19, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 23, 24, 25, 26, 27, 28, 16, 22, 21, 20, 19, 18 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 24, 25, 26, 27, 28, 22, 21, 20, 19, 18. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.26 0.83 0.21 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.17 -0.36 0.03 0.04 (loc) 8-11 8-14 6 8-11 l/defl >999 >687 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 72 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 2=0-3-8, 6=0-3-8 Max Horz 2=74(LC 12) Max Uplift 2=-77(LC 12), 6=-77(LC 13) Max Grav 2=922(LC 19), 6=922(LC 20) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1362/110, 3-4=-1009/75, 4-5=-1009/75, 5-6=-1362/111 BOT CHORD 2-8=-97/1146, 6-8=-24/1146 WEBS 4-8=-9/660, 5-8=-441/153, 3-8=-441/152 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 6. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 6.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-1], [2:0-2-9,Edge], [16:0-2-9,Edge], [16:Edge,0-1-1], [24:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.07 0.03 0.05 DEFL. Vert(LL) Vert(CT) Horz(CT) in 0.00 0.00 0.00 (loc) 16 16 16 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 99 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 20-8-0. (lb) - Max Horz 2=74(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18 Max Grav All reactions 250 lb or less at joint(s) 2, 24, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 25, 26, 27, 28, 29, 30, 23, 16, 22, 21, 20, 19, 18. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 22-7-0 3-10-3 3-10-3 3-10-3 7-6-14 3-8-10 11-3-8 3-8-10 15-0-2 3-8-10 18-8-13 3-8-10 22-7-0 3-10-3 0-8-11 8-3-0 0-8-11 8.00 12 Plate Offsets (X,Y)-- [1:Edge,0-4-13], [4:0-0-8,0-1-8], [6:0-0-8,0-1-8], [9:Edge,0-4-13], [11:0-3-8,0-4-8], [13:0-3-8,0-4-8] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 NO IRC2018/TPI2014 CSI. TC BC WB Matrix-MSH 0.97 0.57 0.68 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.15 -0.29 0.08 0.09 (loc) 11-12 11-12 9 12-13 l/defl >999 >926 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 289 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x6 SP DSS WEBS 2x4 SPF No.2 *Except* 5-12: 2x4 SPF 1650F 1.5E SLIDER Left 2x6 SP DSS -t 2-3-0, Right 2x6 SP DSS -t 2-3-0 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-1-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=0-3-8 (req. 0-7-1), 9=0-3-8 (req. 0-6-9) Max Horz 1=-144(LC 24) Max Uplift 1=-713(LC 10), 9=-632(LC 11) Max Grav 1=9035(LC 1), 9=8403(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-3=-11137/897, 3-4=-9784/797, 4-5=-7766/670, 5-6=-7767/670, 6-7=-10066/794, 7-9=-11617/893 BOT CHORD 1-14=-779/9051, 13-14=-779/9051, 12-13=-645/8141, 11-12=-587/8377, 10-11=-679/9441, 9-10=-679/9441 WEBS 5-12=-673/8366, 6-12=-3432/349, 6-11=-270/3846, 7-11=-1346/169, 7-10=-124/1922, 4-12=-3249/353, 4-13=-276/3591, 3-13=-1245/170, 3-14=-125/1743 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-6-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 4) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) WARNING: Required bearing size at joint(s) 1, 9 greater than input bearing size. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=713, 9=632. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. Continued on page 2 April 23,2021 8-3-0 0-8-11 8.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [8:0-4-7,Edge], [10:0-5-0,0-3-4] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.19 0.90 0.27 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.22 -0.44 0.03 0.03 (loc) 10-17 10-17 8 10-13 l/defl >999 >617 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 87 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 -t 1-6-0, Right 2x4 SPF No.2 -t 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 2=0-3-8, 8=0-3-8 Max Horz 2=159(LC 9) Max Uplift 2=-74(LC 10), 8=-74(LC 11) Max Grav 2=963(LC 1), 8=963(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-1034/113, 4-5=-915/103, 5-6=-915/103, 6-8=-1034/113 BOT CHORD 2-10=-111/924, 8-10=-19/922 WEBS 5-10=-1/634, 6-10=-325/172, 4-10=-324/172 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 7) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 7-7-8 10-3-8 2-8-0 14-11-8 4-8-0 22-7-0 7-7-8 -1-0-0 1-0-0 5-3-8 5-3-8 5-9-8 0-6-0 11-3-8 5-6-0 16-9-8 5-6-0 22-7-0 5-9-8 23-7-0 1-0-0 0-8-11 8-3-0 0-8-11 8.00 12 Plate Offsets (X,Y)-- [2:0-3-3,0-0-3], [22:0-3-3,0-0-3], [31:0-3-0,0-3-0] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.16 0.28 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.02 -0.03 0.01 0.02 (loc) 32-33 32-33 2 33-36 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 139 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF 1650F 1.5E BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF No.2 OTHERS 2x4 SPF No.2 SLIDER Left 2x4 SPF No.2 -t 1-6-0, Right 2x4 SPF No.2 -t 1-6-0 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. Except: 6-0-0 oc bracing: 11-32 JOINTS 1 Brace at Jt(s): 10, 6 REACTIONS. All bearings 12-3-8 except (jt=length) 2=0-3-8. (lb) - Max Horz 2=159(LC 9) Max Uplift All uplift 100 lb or less at joint(s) 2, 22, 32, 30, 29, 28, 27, 26, 25, 24 Max Grav All reactions 250 lb or less at joint(s) 22, 31, 30, 29, 28, 27, 26, 25, 24, 22 except 2=499(LC 18), 32=657(LC 18), 32=455(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-415/77, 4-6=-483/114, 6-8=-506/126, 8-10=-530/141, 10-12=-585/169 BOT CHORD 2-33=-69/425, 32-33=-69/425, 12-32=-505/167 WEBS 4-33=0/262 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable studs spaced at 1-4-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 22, 32, 30, 29, 28, 27, 26, 25, 24, 22. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. 12) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. April 23,2021 35-2-0 35-2-0 17-7-0 17-7-0 35-2-0 17-7-0 0-6-8 9-4-0 0-6-8 6.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.08 0.04 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in n/a n/a 0.01 (loc) - - 27 l/defl n/a n/a n/a L/d 999 999 n/a PLATES MT20 Weight: 217 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 14-40, 13-41, 15-39 REACTIONS. All bearings 35-2-0. (lb) - Max Horz 1=118(LC 16) Max Uplift All uplift 100 lb or less at joint(s) 41, 42, 44, 45, 46, 47, 48, 49, 50, 51, 52, 39, 38, 36, 35, 34, 33, 32, 31, 30, 29, 28, 1 Max Grav All reactions 250 lb or less at joint(s) 40, 41, 42, 44, 45, 46, 47, 48, 49, 50, 51, 52, 39, 38, 36, 35, 34, 33, 32, 31, 30, 29, 28, 1, 27 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 41, 42, 44, 45, 46, 47, 48, 49, 50, 51, 52, 39, 38, 36, 35, 34, 33, 32, 31, 30, 29, 28, 1. 11) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021 12-5-6 6-5-14 17-7-0 5-1-10 22-8-10 5-1-10 29-2-7 6-5-14 35-2-0 5-11-9 0-6-8 9-4-0 0-6-8 6.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-13], [9:0-0-0,0-1-13] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.45 0.74 0.33 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.25 -0.43 0.11 0.09 (loc) 12-14 12-14 9 12-14 l/defl >999 >983 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 141 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-12, 4-12 REACTIONS. (size) 1=Mechanical, 9=Mechanical Max Horz 1=115(LC 12) Max Uplift 1=-101(LC 12), 9=-101(LC 13) Max Grav 1=1542(LC 2), 9=1542(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2754/210, 2-4=-2531/174, 4-5=-1809/165, 5-6=-1809/165, 6-8=-2531/174, 8-9=-2754/210 BOT CHORD 1-14=-247/2399, 12-14=-119/1956, 10-12=-28/1956, 9-10=-132/2399 WEBS 6-12=-704/177, 6-10=-7/559, 5-12=-68/1339, 8-10=-325/170, 4-12=-704/177, 4-14=-7/559, 2-14=-325/170 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=101, 9=101. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 19-2-0 3-0-0 25-10-9 6-8-9 27-1-1 1-2-8 35-2-0 8-0-15 5-11-9 5-11-9 10-9-15 4-10-6 12-5-6 1-7-7 16-2-0 3-8-10 17-7-0 1-5-0 19-2-0 1-7-0 22-8-10 3-6-10 27-1-1 4-4-8 29-2-7 2-1-6 35-2-0 5-11-9 0-6-8 9-4-0 0-6-8 2-0-0 6.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-13], [11:Edge,0-1-13], [12:0-3-14,0-2-13], [14:0-6-0,0-4-4], [15:0-2-12,0-2-8], [17:0-2-10,0-3-2] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.44 0.61 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.17 -0.34 0.15 0.10 (loc) 14-15 12-23 11 14-15 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 174 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-16,7-13: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 1=Mechanical, 11=Mechanical Max Horz 1=115(LC 16) Max Uplift 1=-101(LC 12), 11=-101(LC 13) Max Grav 1=1407(LC 1), 11=1407(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2539/213, 2-4=-2257/171, 4-5=-2258/185, 5-6=-2181/210, 6-7=-2211/180, 7-8=-2282/167, 8-10=-2257/172, 10-11=-2539/214 BOT CHORD 1-17=-250/2196, 14-15=-19/1763, 11-12=-136/2196 WEBS 15-17=-143/2093, 6-14=-125/1037, 12-14=-36/2109, 10-12=-336/174, 2-17=-335/174, 4-17=-296/39, 6-15=-141/1028, 8-12=-316/81 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=101, 11=101. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 19-2-0 3-0-0 25-10-9 6-8-9 35-2-0 9-3-7 5-11-9 5-11-9 12-4-11 6-5-2 12-5-6 0-0-11 16-2-0 3-8-10 17-7-0 1-5-0 19-2-0 1-7-0 22-8-9 3-6-9 29-2-7 6-5-14 35-2-0 5-11-9 36-2-0 1-0-0 0-6-8 9-4-0 0-6-8 2-0-0 6.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-13], [11:Edge,0-1-9], [13:0-3-8,0-3-0], [15:0-6-0,0-4-4], [16:0-2-12,0-2-8], [18:0-2-7,0-3-1] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.46 0.62 0.52 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.17 -0.34 0.15 0.10 (loc) 15-16 18-21 11 15-16 l/defl >999 >999 n/a >999 L/d 360 240 n/a 240 PLATES MT20 Weight: 175 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E *Except* 5-17,7-14: 2x4 SPF No.2 WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. REACTIONS. (size) 1=Mechanical, 11=0-3-8 Max Horz 1=-128(LC 17) Max Uplift 1=-100(LC 12), 11=-118(LC 13) Max Grav 1=1406(LC 1), 11=1468(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2538/213, 2-4=-2256/171, 4-5=-2255/183, 5-6=-2178/207, 6-7=-2207/177, 7-8=-2279/164, 8-10=-2251/170, 10-11=-2531/211 BOT CHORD 1-18=-243/2194, 15-16=-11/1761, 11-13=-120/2187 WEBS 8-13=-318/79, 16-18=-135/2091, 6-15=-122/1034, 13-15=-28/2105, 10-13=-331/172, 2-18=-335/174, 4-18=-296/36, 6-16=-140/1028 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=100, 11=118. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 5-11-9 12-5-6 6-5-14 17-7-0 5-1-10 22-8-10 5-1-10 29-2-7 6-5-14 35-2-0 5-11-9 36-2-0 1-0-0 0-6-8 9-4-0 0-6-8 6.00 12 Plate Offsets (X,Y)-- [1:0-0-0,0-1-9], [9:Edge,0-1-9] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.48 0.75 0.33 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.25 -0.43 0.12 0.09 (loc) 11-13 11-13 9 13-15 l/defl >999 >978 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 142 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 6-13, 4-13 REACTIONS. (size) 1=Mechanical, 9=0-3-8 Max Horz 1=-128(LC 17) Max Uplift 1=-100(LC 12), 9=-118(LC 13) Max Grav 1=1541(LC 2), 9=1593(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2752/210, 2-4=-2529/174, 4-5=-1808/165, 5-6=-1808/165, 6-8=-2525/172, 8-9=-2747/208 BOT CHORD 1-15=-241/2397, 13-15=-112/1954, 11-13=-21/1953, 9-11=-117/2391 WEBS 6-13=-702/176, 6-11=-5/554, 5-13=-68/1338, 8-11=-321/169, 4-13=-704/177, 4-15=-7/559, 2-15=-325/170 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Refer to girder(s) for truss to truss connections. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 1=100, 9=118. 10) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 -1-0-0 1-0-0 5-11-9 5-11-9 12-5-6 6-5-14 17-7-0 5-1-10 22-8-10 5-1-10 29-2-7 6-5-14 35-2-0 5-11-9 36-2-0 1-0-0 0-6-8 9-4-0 0-6-8 6.00 12 Plate Offsets (X,Y)-- [2:0-0-0,0-1-9], [10:Edge,0-1-9] LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-AS 0.48 0.75 0.33 DEFL. Vert(LL) Vert(CT) Horz(CT) Wind(LL) in -0.25 -0.43 0.12 0.09 (loc) 14-16 14-16 10 14-16 l/defl >999 >978 n/a >999 L/d 360 240 n/a 240 PLATES MT20 MT18HS Weight: 144 lb FT = 20% GRIP 197/144 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E WEBS 2x4 SPF No.2 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 BRACING- TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied. WEBS 1 Row at midpt 7-14, 5-14 REACTIONS. (size) 2=0-3-8, 10=0-3-8 Max Horz 2=-121(LC 17) Max Uplift 2=-118(LC 12), 10=-118(LC 13) Max Grav 2=1592(LC 2), 10=1592(LC 2) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2746/207, 3-5=-2524/172, 5-6=-1806/164, 6-7=-1806/164, 7-9=-2524/172, 9-10=-2746/207 BOT CHORD 2-16=-238/2390, 14-16=-111/1952, 12-14=-21/1952, 10-12=-117/2390 WEBS 6-14=-68/1337, 7-14=-702/176, 7-12=-5/554, 9-12=-321/169, 5-14=-702/176, 5-16=-5/554, 3-16=-321/169 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=118, 10=118. 9) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum sheetrock be applied directly to the bottom chord. April 23,2021 5x6 3x6 5x6 35-2-0 35-2-0 -1-0-0 1-0-0 17-7-0 17-7-0 35-2-0 17-7-0 36-2-0 1-0-0 0-6-8 9-4-0 0-6-8 6.00 12 LOADING (psf) TCLL (Roof Snow=20.0) TCDL BCLL BCDL 20.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-S 0.09 0.04 0.13 DEFL. Vert(LL) Vert(CT) Horz(CT) in -0.00 0.00 0.01 (loc) 28 28 28 l/defl n/r n/r n/a L/d 120 90 n/a PLATES MT20 Weight: 219 lb FT = 20% GRIP 197/144 LUMBER- TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF 1650F 1.5E OTHERS 2x4 SPF No.2 WEDGE Left: 2x4 SPF No.2 , Right: 2x4 SPF No.2 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 15-42, 14-43, 16-41 REACTIONS. All bearings 35-2-0. (lb) - Max Horz 2=-121(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 43, 44, 46, 47, 48, 49, 50, 51, 52, 53, 54, 41, 40, 2, 38, 37, 36, 35, 34, 33, 32, 31, 30 Max Grav All reactions 250 lb or less at joint(s) 28, 42, 43, 44, 46, 47, 48, 49, 50, 51, 52, 53, 54, 41, 40, 2, 38, 37, 36, 35, 34, 33, 32, 31, 30 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=4.2psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; Enclosed; MWFRS (envelope) gable end zone and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-16; Pf=20.0 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 1-4-0 oc. 9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 43, 44, 46, 47, 48, 49, 50, 51, 52, 53, 54, 41, 40, 2, 38, 37, 36, 35, 34, 33, 32, 31, 30. 12) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. April 23,2021