Loading...
HomeMy WebLinkAboutM004.024" OC SPACING Truss Connector Total List ManufProduct Qty USP HUS2619 USP RT7A*100 24" OC SPACING Hatch Legend 2' STEP CLG 6-00-00 20-08-00 33-00-00 59-08-00 13-02-00 35-02-00 11-04-00 59-08-00 19-10-00 10-07-00 5-05-00 35-10-00 7-10-00 17-08-00 10-04-00 35-10-00 8-02-00 J01 J04 A07 (11) HUS26 (8) HUS26 A05 A04 A04 A03 A02 A02 A01 E01 B01 B03 C01 D01 D03 J05 J06 V01 V02 V03 V04 V05 V06 V01 V02 V03 V04 V05 V06 V07 (8) J02 (5) J03 (7) A06 (2) E02 (3) B02 (3) C02 (2) D02 (3) J06 3 PLY 2 PLY 5-11-08 6-11-00 IMPORTANT THIS DRAWINGIS FOR FIELD PLACEMENT OF INDIVIDUAL COMPONENTS ONLY,AND DOES NOT CONSTITUTE AN ENGINEERED DOCUMENT. NOTE PROPER BEARINGANDBEARINGDESIGN INCLUDING ANCHORAGE,IS THE RESPONSIBILITY OF THE BUILDING DESIGNER,ARCHITECT AND /OR BUILDINGENGINEER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS,MINIMUM REQUIRED BEARINGSIZE,UPLIFT,AND ADDITIONAL LOADS. 84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN THESE AREAS OF CONCERN. BRACING ERECTION,TEMPORARY,AND PERMANENT BRACINGIS THE RESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDING DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR ADDITIONAL BRACINGREQUIREMENTS. REFER TO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTS ASSOCIATION COMMENTARY,AND RECOMMENDATIONS FOR HANDLING,INSTALLING&BRACINGMETALPLATECONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONS CALL 84 COMPONENTS. PROPER INSTALLATION,AND HANDLINGOFCOMPONENTS IS THE RESPONSIBILITY OF THE ERECTINGCONTRACTOR.84 COMPONENTS MUST BE NOTIFIED OF ANY PROBLEMS,AND AFFORDED THE OPPORTUNITY TO REVIEW,AND MAKE NECESSARY CORRECTIONS,OR NO BACK CHARGES WILL BE ACCEPTED OR APPROVED. WARNING WARNINGS,AND INSTRUCTIONS FOR ERECTION OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE. KEEP THIS INFORMATION ON THE JOB SITE. THESE DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTS MAY RESULT IN FAILURE,BODILY INJURY,LOSS OF PROPERTY,AND /OR LIFE. RoofArea: Overhang Length: Eave Length: HipLength: ValleyLength: Ridge Length: SHEETNUMBER: R1.1 RoofTruss PlacementPlan SCALE: NTS Job#: 24243 PO#: Date: 4/15/2021 Drawn By: Designed By: Checked By: ROOF LOADS: TCLL: 20.0 lb/ft² TCDL: 10.0 lb/ft² BCLL: 0.0 lb/ft² BCDL:10.0 lb/ft² Building Code: IRC 2012 Wind Speed: 115 mph On-Center Spacing: 24" U.N.O. 2307.99 SF 113.08 LF 212.09 LF 0 LF 80.03LF 88.31 LF ROOF DATA THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION. TG139 6947 PICKETT PLACE CARMEL , IN ROOF TRUSS PLACEMENTPLAN 24243 1850 N Graham Road Franklin, Indiana 46131 Office:(317) 346-4274 Fax: (317) 346-0916 05/03/21