HomeMy WebLinkAboutM004.024" OC
SPACING
24" OC
SPACING
24" OC
SPACING
Hatch Legend
2' STEP CLG
5-00-00 21-08-00 17-04-00 10-00-00
54-00-00
54-00-00
20-00-00 15-10-00
35-10-00
8-00-00 15-02-00 12-08-00
35-10-00
6-00-00
E01
C01
C02
A01
A04
D02
D01
B01
J08
J05
J04
J01
(10) A02 (3) A03 (7) A02
(3) B02
(7) J07
(6) J06
(2) J03
(5) J02
1-04-00
2-00-00
1-08-00
IMPORTANT
THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL
COMPONENTS ONLY,AND DOES NOT CONSTITUTE AN
ENGINEERED DOCUMENT.
NOTE
PROPER BEARING AND BEARING DESIGN INCLUDING
ANCHORAGE,IS THE RESPONSIBILITY OF THE BUILDING
DESIGNER,ARCHITECT AND /OR BUILDING ENGINEER. REFER
TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS,MINIMUM
REQUIRED BEARING SIZE,UPLIFT,AND ADDITIONAL LOADS.
84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN
THESE AREAS OF CONCERN.
BRACING
ERECTION,TEMPORARY,AND PERMANENT BRACING IS THE
RESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDING
DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR
ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1
SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS
ASSOCIATION COMMENTARY,AND RECOMMENDATIONS FOR
HANDLING,INSTALLING &BRACING METAL PLATE CONNECTED
WOOD TRUSSES. www.sbcindustry.com
INSTALLATION
DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONS
CALL 84 COMPONENTS. PROPER INSTALLATION,AND
HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE
ERECTING CONTRACTOR. 84 COMPONENTS MUST BE
NOTIFIED OF ANY PROBLEMS,AND AFFORDED THE
OPPORTUNITY TO REVIEW,AND MAKE NECESSARY
CORRECTIONS,OR NO BACK CHARGES WILL BE ACCEPTED
OR APPROVED.
WARNING
WARNINGS,AND INSTRUCTIONS FOR ERECTION
OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE.
KEEP THIS INFORMATION ON THE JOB SITE. THESE
DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE
INSPECTION. MISUSE AND IMPROPER INSTALLATION OF
COMPONENTS MAY RESULT IN FAILURE,BODILY INJURY,LOSS
OF PROPERTY,AND /OR LIFE.
RoofArea:
Overhang Length:
Eave Length:
HipLength:
ValleyLength:
Ridge Length:
SHEETNUMBER:
R1.1
RoofTruss
PlacementPlan
SCALE: NTS
Job#: 24339
PO#:
Date: 4/23/2021
Drawn By: DS
Designed By: DS
Checked By:
ROOF LOADS:
TCLL: 20.0 lb/ft²
TCDL: 10.0 lb/ft²
BCLL: 0.0 lb/ft²
BCDL:10.0 lb/ft²
Building Code: IRC 2012
Wind Speed: 115 mph
On-Center Spacing: 24" U.N.O.
2353.78 SF
170.92 LF
161.7 LF
0 LF
0 LF
64.17 LF
ROOF DATA
THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION.
TG89
6995 PICKETT PL
CARMEL , IN
ROOF TRUSS PLACEMENTPLAN
24339
1850 N Graham Road
Franklin, Indiana 46131
Office:(317) 346-4274
Fax: (317) 346-0916
05/04/21