Loading...
HomeMy WebLinkAboutM004.024" OC SPACING 24" OC SPACING 24" OC SPACING Hatch Legend 2' STEP CLG 5-00-00 21-08-00 17-04-00 10-00-00 54-00-00 54-00-00 20-00-00 15-10-00 35-10-00 8-00-00 15-02-00 12-08-00 35-10-00 6-00-00 E01 C01 C02 A01 A04 D02 D01 B01 J08 J05 J04 J01 (10) A02 (3) A03 (7) A02 (3) B02 (7) J07 (6) J06 (2) J03 (5) J02 1-04-00 2-00-00 1-08-00 IMPORTANT THIS DRAWING IS FOR FIELD PLACEMENT OF INDIVIDUAL COMPONENTS ONLY,AND DOES NOT CONSTITUTE AN ENGINEERED DOCUMENT. NOTE PROPER BEARING AND BEARING DESIGN INCLUDING ANCHORAGE,IS THE RESPONSIBILITY OF THE BUILDING DESIGNER,ARCHITECT AND /OR BUILDING ENGINEER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR REACTIONS,MINIMUM REQUIRED BEARING SIZE,UPLIFT,AND ADDITIONAL LOADS. 84 COMPONENTS DOES NOT ASSUME RESPONSIBILITY IN THESE AREAS OF CONCERN. BRACING ERECTION,TEMPORARY,AND PERMANENT BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR AND /OR BUILDING DESIGNER. REFER TO INDIVIDUAL TRUSS DESIGNS FOR ADDITIONAL BRACING REQUIREMENTS. REFER TO BCSI-B1 SUMMARY SHEET. THE STRUCTURAL BUILDING COMPONENTS ASSOCIATION COMMENTARY,AND RECOMMENDATIONS FOR HANDLING,INSTALLING &BRACING METAL PLATE CONNECTED WOOD TRUSSES. www.sbcindustry.com INSTALLATION DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONS CALL 84 COMPONENTS. PROPER INSTALLATION,AND HANDLING OF COMPONENTS IS THE RESPONSIBILITY OF THE ERECTING CONTRACTOR. 84 COMPONENTS MUST BE NOTIFIED OF ANY PROBLEMS,AND AFFORDED THE OPPORTUNITY TO REVIEW,AND MAKE NECESSARY CORRECTIONS,OR NO BACK CHARGES WILL BE ACCEPTED OR APPROVED. WARNING WARNINGS,AND INSTRUCTIONS FOR ERECTION OF COMPONENTS ARE INCLUDED IN THE DELIVERY PACKAGE. KEEP THIS INFORMATION ON THE JOB SITE. THESE DOCUMENTS WILL ALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE AND IMPROPER INSTALLATION OF COMPONENTS MAY RESULT IN FAILURE,BODILY INJURY,LOSS OF PROPERTY,AND /OR LIFE. RoofArea: Overhang Length: Eave Length: HipLength: ValleyLength: Ridge Length: SHEETNUMBER: R1.1 RoofTruss PlacementPlan SCALE: NTS Job#: 24339 PO#: Date: 4/23/2021 Drawn By: DS Designed By: DS Checked By: ROOF LOADS: TCLL: 20.0 lb/ft² TCDL: 10.0 lb/ft² BCLL: 0.0 lb/ft² BCDL:10.0 lb/ft² Building Code: IRC 2012 Wind Speed: 115 mph On-Center Spacing: 24" U.N.O. 2353.78 SF 170.92 LF 161.7 LF 0 LF 0 LF 64.17 LF ROOF DATA THIS LAYOUTIS INTENDED FOR THE PURPOSE OF TRUSS LOCATION AND PLACEMENTONLY. REFER TO THE BUILDINGPLANS FOR ACTUAL BUILDINGCONSTRUCTION. TG89 6995 PICKETT PL CARMEL , IN ROOF TRUSS PLACEMENTPLAN 24339 1850 N Graham Road Franklin, Indiana 46131 Office:(317) 346-4274 Fax: (317) 346-0916 05/04/21