Loading...
HomeMy WebLinkAboutE100.0FAN/LIGHT, VENT \PTO EXT. FAN, VENT \PTO EXT. TO BELOW FAN, VENT TO EXT.FIRST FLOOR ELECTRICAL PLAN1/4" = 1'-0" FAN/LIGHT, VENT \PTO EXT.WP\PGFI FAN, VENT \PTO EXT. DED.DED. DED. \pxsm1;WP GFI DISP S TV PH S S S R SSS S 220V S GFI WP/GFI 3SRRR S SSGFI DW R GFI S GFI GFI S GFI 3S R S R S S S GFIGFI R SSS S S GFIGFIGFI GFIGFIGFIGFI GFI GFI 3S 3S3S S R 3S TV S SR WP/GFIS R R R R R R 3S 3SPH S/C S/C S CH CH CH CH CH CHCH GDOGDO S S4 GFI WP/GFI RR SS3 S3 RR Electrical Schedule TableSymbol Type Additional Notes S/CS R 220VDWGFIGDOPHTVWP/GFIS3SDETECTOR - SMOKE/CARBON MONOXIDE COMBINATIONDETECTOR - SMOKEFAN - CEILING W/ LIGHTFAN - EXHAUSTFAN - EXHAUST W/ LIGHTFAN - EXHAUST-VENT TO EXTERIORLIGHT - CEILINGLIGHT - RECESSEDLIGHT - WALLOUTLET - 220VOUTLET - DISHWASHEROUTLET - DUPLEXOUTLET - DUPLEX-SPLIT WIREDOUTLET - GFIOUTLET - GARAGE DOOROUTLET - PHONEOUTLET - TVOUTLET - WATERPROOF-GFISWITCH - LIGHTSWITCH - THREE WAY UL APPROVED CEILING MOUNTED SMOKE /CO DETECTOR TO BE HARD WIRED WITH BATTERY BACK-UP (INSTALL PER R314.4)110V W/ BATTERY BACKUP\PINTERCONNECTEDFAN BOX PER NEC. PROVIDE 4-WIRE CABLE FROM SWITCH(ES) (CLG FAN OPTIONAL)50 CFM MIN INTERMITTENT FAN EXHAUST TO EXTERIORCAT 5ERG-6 \pxql,t1;{\T0.9;ALL ELECTRICAL INSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE (N.E.C.). ALL MATERIAL AND EQUIPMENT SHALL BEAR THE LABEL OF APPROVAL OF THE UNDERWRITERS LABORATORIES, INC. AND MEET THE REQUIREMENTS OF THE N.E.C..\P\P1. STAIRWAYS WITHIN DWELLING UNITS SHALL HAVE AN ILLUMINATION LEVEL ON THE TREAD RUNS OF NOT LESS THAN 1 FOOTCANDLE. PROVIDE LIGHTING CONTROL AT EACH LEVEL. EXTERIOR STAIRWAYS SERVING A DWELLING UNIT SHALL HAVE A LIGHT IN THE IMMEDIATE VICINITY OF THE STAIR LANDING CLOSEST TO THE DWELLING UNIT. \P\P2. GFI PROTECTION SHALL BE PROVIDED FOR ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS:\P - BATHROOMS\P - GARAGE\P - OUTDOORS: BALCONIES, DECKS, AND PORCHES (INCLUDING INSIDE SCREENED ENCLOSURES)\P - UNFINISHED BASEMENT AREAS AND CRAWL SPACES, EXCEPT FOR LAUNDRY CIRCUIT AND SINGLE RECEPTACLE DEDICATED TO SUMP PUMPS\P - RECEPTACLES INTENDED TO SERVE KITCHEN COUNTER TOP SURFACES\P - RECEPTACUTILITY NOTESIndiana Division11590 North Meridian Street, Suite 530Carmel, Indiana 46032PLAN NAME SHEET PRODUCTION MANAGER DATE / DESCRIPTION NPC PLAN NUMBERLAWSON PLAN ID GARAGE HANDING REV # NOTE: SCALES NOTED ON DRAWINGS RELATE TO FULL SIZE PLOTS ON 22x34 SHEETS - 11x17 SHEETS REPRESENT 1/2 SCALE PLOTS INITIAL RELEASE DATE:CURRENT RELEASE DATE: (c) Copyright Pulte Home Corporation - 2021 Zach Bittner3/30/2015 GARAGE RIGHT 2596-Geneva 1836.0000 LOT 13 03/18/2021 PLOTTED: March 31, 2021 / Nick Musial / 2596-IN-MEPP.DWG First FloorElectrical Plans6.10 05/17/21