Loading...
HomeMy WebLinkAbout82640-W1 SEALED 2106478-12TDE DANSCO ENGINEERING, LLC P.O. Box 3400 Apollo Beach, FL 33572 Telephone (813) 645-0166 Facsimile (813) 645-9698 The truss drawing(s) attached have been prepared by Dansco Engineering, LLC under my direct supervision and control based on the parameters provided by Stark Truss Inc. Job: 2106478-12T 18 truss design(s) 82640-W1 04/16/2021 Samuel A. Greenberg, P.E. Indiana Reg. #19700485 Indiana Residential Building Code 2020 based on IRC 2018 with Indiana specific amendments. 675 IAC 14-4.4-81 Section R802.10.1; truss design drawings, R802.10.1; truss design drawings shall be provided to the building official as required by the General Administrative Rules (675 IAC 12) for Class 1 structures or by local ordinance for Class 2 structures. Note: Gable end frames with stud lengths exceeding 4’ require permanent bracing. On structural gables, where studs may be made from two or more boards as they cross diagonals, the 4’ length is the distance from the top chord to bottom chord. The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI 1-2014 Chapter 2. Warning !—Verify design parameters and read notes before use. These designs are based only upon parameters shown, and are for individual building components to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer – not truss designer or truss engineer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to ensure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction and BCSI 1-03 Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses from Truss Plate Institute, 583 D’Onofrio Drive, Madison, WI 53719 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =4x4 =3x6 =4x4 =3x5 =4x4 =6x8 =3x5 =4x4 =3x6 =4x4 12 15 11 16 10 17 9 18 19 8 71 62 13 14 53 4 T1 T1 W1 W1 B1 W3 W2 W4 W5 W4 W3 W2 0-7-12 14-3-12 0-7-12 -0-7-12 3-4-2 6-10-0 3-4-2 10-2-2 3-5-14 13-8-0 3-5-14 3-5-14 3-2-13 13-8-0 3-2-13 3-2-13 3-7-3 6-10-0 3-7-3 10-5-31-7-116-2-6Scale = 1:36.9 Plate Offsets (X, Y):[8:Edge,0-3-8], [10:0-4-0,0-4-4] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.31 Vert(LL)-0.03 10-11 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.45 Vert(CT)-0.05 10-11 >999 240 TCDL 10.0 Rep Stress Incr NO WB 0.52 Horz(CT)0.01 8 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 157 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (lb/size)8=3139/0-6-0, (min. 0-2-11), 12=2947/0-6-0, (min. 0-2-9) Max Horiz 12=-188 (LC 10) Max Uplift 8=-710 (LC 13), 12=-670 (LC 12) Max Grav 8=3448 (LC 2), 12=3239 (LC 2) 1 1FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-13=-2886/593, 3-13=-2797/602, 3-4=-2373/554, 4-5=-2373/554, 5-14=-2722/586, 6-14=-2811/577, 2-12=-2689/572,6-8=-2619/557 BOT CHORD 12-15=-188/259, 11-15=-188/259, 11-16=-483/2305, 10-16=-483/2305, 10-17=-427/2250, 9-17=-427/2250 WEBS 3-11=-126/561, 2-11=-446/2401, 3-10=-569/214, 4-10=-520/2356, 5-10=-489/198, 5-9=-106/461, 6-9=-432/2331 NOTES 1)2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Web connected as follows: 2x4 - 1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided todistribute only loads noted as (F) or (B), unless otherwise indicated. 3)Unbalanced roof live loads have been considered for this design. 4)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 5)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 6)Unbalanced snow loads have been considered for this design.7)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 670 lb uplift at joint 12 and 710 lb uplift at joint 8. 10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 11)Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 788 lb down and 163 lb up at 1-1-4, 788 lb down and 163 lb up at 3-1-4, 788 lb down and 163 lb up at 5-1-4, 788 lb down and 163 lb up at 7-1-4, 788 lb down and 163 lb up at 9-1-4, and 788 lb down and 163 lb up at 11-1-4, and 794 lb down and 160 lb up at 13-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1)Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15 Uniform Loads (lb/ft) Vert: 1-2=-51, 2-4=-51, 4-6=-51, 6-7=-51, 8-12=-20 Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 G01 2 22106478-12T Common Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:KUt3LmHo1F8YOYn5qWEnCfzoZQA-njueMbMKpjrBhgSiPvSDmlYV40V4mnlLO2VVj3zQSdI Continued on page 2 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. Concentrated Loads (lb) Vert: 11=-722, 10=-722, 15=-722, 16=-722, 17=-722, 18=-722, 19=-728 Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 G01 2 22106478-12T Common Girder Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 2 ID:KUt3LmHo1F8YOYn5qWEnCfzoZQA-njueMbMKpjrBhgSiPvSDmlYV40V4mnlLO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x4 =3x4 =3x4 =3x4 =3x4 =3x4 28 27 26 25 24 23 22 21 20 19 18 17 16 151 2 14 3 13 3229 4 12 5 11 30 31 6 10 7 9 8 T1 T1 W1 W1 B1 B2 ST5 ST5 ST4 ST3 ST2 ST1 ST4 ST3 ST2 ST1 0-7-12 -0-7-12 0-7-12 21-5-12 10-5-0 20-10-0 10-5-0 10-5-0 20-10-01-7-118-7-0Scale = 1:45 Plate Offsets (X, Y):[8:0-2-0,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.23 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.13 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.16 Horz(CT)0.00 16 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 111 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud *Except* ST5:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 20-10-0. (lb) -Max Horiz 28=-256 (LC 14) Max Uplift All uplift 100 (lb) or less at joint(s) 18, 19, 24, 26 except 16=-170 (LC 13), 17=-196 (LC 12), 20=-120 (LC 17), 23=-119 (LC 16), 27=-211 (LC 13), 28=-191 (LC 12) Max Grav All reactions 250 (lb) or less at joint(s) 16, 18, 19, 20, 21, 22,23, 24, 26, 28 except 17=266 (LC 15), 27=283 (LC 14) 3 3FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 6-7=-157/307, 9-10=-157/307 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) -0-7-12 to 2-4-4, Exterior(2N) 2-4-4 to 10-5-0, Corner(3R) 10-5-0 to 13-5-0, Exterior(2N) 13-5-0 to 21-5-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads.7)All plates are 1.5x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 24, 26, 19, 18 except (jt=lb) 28=190, 16=169, 23=119, 27=211, 20=119, 17=195. 13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 GE01 4 12106478-12T Common Supported Gable Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:n5OAqoGdNMBhQa0pQQL?FZzoZZD-M8CVkaJSWoTdqCk7jnuW96w05oYNZWdui4Gr6kzQSdL WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x4 =3x4 =4x4 =3x4 =3x4 20 19 18 17 16 15 14 13 12 111 102 3 9 222148 5 7 6 W1 T1 T1 W1 B1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 0-7-12 14-3-12 0-7-12 -0-7-12 6-10-0 6-10-0 6-10-0 13-8-0 13-8-01-7-116-2-6Scale = 1:35.6 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.17 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.09 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.15 Horz(CT)0.00 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 66 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 13-8-0. (lb) -Max Horiz 20=-192 (LC 14) Max Uplift All uplift 100 (lb) or less at joint(s) 14, 15, 17, 18 except 12=-200 (LC 13), 13=-197 (LC 12), 19=-213 (LC 13), 20=-220 (LC 12) Max Grav All reactions 250 (lb) or less at joint(s) 12, 14, 15, 16, 17, 18, 20 except 13=271 (LC 15), 19=288 (LC 14) 4 4FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 5-6=-127/281, 6-7=-127/281 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) -0-7-12 to 2-4-4, Exterior(2N) 2-4-4 to 6-10-0, Corner(3R) 6-10-0 to 9-10-0, Exterior(2N) 9-10-0 to 14-3-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consultqualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)All plates are 1.5x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 18, 15, 14 except (jt=lb) 20=220, 12=200, 19=213,13=197. 13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 GE02 2 12106478-12T Common Supported Gable Job Reference (optional) Run: 8.31 S Jul 27 2019 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:83B3tVKlCuq_WLunCzxAyczoZZ8-njueMbMKpjrBhgSiPvSDmlYXG0bhmtWLO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =3x4 =3x4 =4x6 =4x6 =5x6 =8x8 =4x6 =4x6 =3x4 =3x4 59 58 57 56 55 54 53 52 5150 49 48 47 46 45 44 43 42 41 4039 38 37 36 35 34 33 32 31 1 3023294285276267258249231022112112206360191361621814171516 W1 T2 T1 T2 T3 W1B1B1B2B2 ST13ST12ST11ST10ST9ST8ST7ST6ST5ST4ST3ST2ST1 ST12 ST11 ST10 ST9 ST8 ST7 ST6 ST5 ST4 ST3 ST2 ST1 0-7-12 -0-7-12 25-2-0 25-2-0 25-2-0 50-4-0 50-4-01-4-69-9-0Scale = 1:82.7 Plate Offsets (X, Y):[45:0-4-0,0-4-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.05 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.04 Vert(CT)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.18 Horz(CT)0.00 31 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 323 lb FT = 20% LUMBER TOP CHORD 2x6 SPF No.2 BOT CHORD 2x6 SPF No.2 WEBS 2x6 SPF No.2 OTHERS 2x4 SPF Stud *Except* ST13,ST12,ST11:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 1 Row at midpt 16-45, 15-46, 17-44 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS All bearings 50-4-0. (lb) -Max Horiz 59=129 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 31, 33, 34, 35, 36, 37, 38, 39, 41, 42, 43, 44, 46, 47, 48, 49, 51, 52, 53, 54, 55, 56, 57, 59 except 32=-169 (LC 17), 58=-215 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 31, 32, 33, 34, 35, 36,37, 38, 39, 41, 42, 43, 44, 45, 46, 47, 48, 49, 51, 52, 53, 54, 55,56, 57, 58, 59 5 5FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 13-61=-105/256, 14-61=-93/259, 14-15=-118/289, 15-16=-127/310, 16-17=-127/302, 17-18=-118/260 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CCorner(3E) -0-7-12 to 4-4-10, Exterior(2N) 4-4-10 to 25-2-0, Corner(3R) 25-2-0 to 30-2-6, Exterior(2N) 30-2-6 to 50-1-4 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design.6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)All plates are 2x4 MT20 unless otherwise indicated. 8)Gable requires continuous bottom chord bearing. 9)Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web). 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 59, 31, 46, 47, 48, 49, 51, 52, 53, 54, 55, 56, 57, 44, 43, 42,41, 39, 38, 37, 36, 35, 34, 33 except (jt=lb) 58=214, 32=169. 13)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 GE03 4 12106478-12T Common Supported Gable Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:zsul7Hl7Hq8HdkWw4c09?BzoD3?-FvR0ZxNya0z2Ip1uyczSJy4kuQxjVKIUdiE2FVzQSdH WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =3x4 =4x4 =4x4 =3x4 =4x4 12 11 19 10 20 9 8 1 72635 17 18 4 T1 T1 W1 W1 B1 W3 W2 W2ST1ST1 0-7-12 -0-7-12 0-7-12 8-4-12 0-7-0 0-7-0 0-7-0 7-9-0 3-3-8 3-10-8 3-3-8 7-2-0 0-2-0 0-7-0 0-2-0 7-4-0 0-5-0 7-9-0 0-5-0 0-5-0 3-3-8 3-10-8 3-3-8 7-2-01-3-62-6-14Scale = 1:31.9 Plate Offsets (X, Y):[8:Edge,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.40 Vert(LL)0.06 10-11 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.30 Vert(CT)0.05 10-11 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT)0.00 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 29 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-6-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)9=304/0-4-0, (min. 0-1-8), 11=304/0-4-0, (min. 0-1-8) Max Horiz 11=21 (LC 15) Max Uplift 9=-186 (LC 13), 11=-186 (LC 12) Max Grav 9=374 (LC 24), 11=374 (LC 23) 6 6FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-129/318, 3-17=-183/394, 4-17=-140/403, 4-18=-140/402, 5-18=-183/394, 5-6=-129/317 BOT CHORD 11-12=-300/133, 11-19=-300/133, 10-19=-300/133, 10-20=-300/133, 9-20=-300/133, 8-9=-300/133 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-7-12 to 2-4-4, Interior (1) 2-4-4 to 3-10-8, Exterior(2R) 3-10-8 to 7-2-0, Interior (1) 7-2-0 to 8-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 5)Unbalanced snow loads have been considered for this design. 6)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 7)All plates are 1.5x4 MT20 unless otherwise indicated. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 11 and 186 lb uplift at joint 9. 11)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 GE04 2 12106478-12T Common Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:UCPgDmmv1m1W?GNxWJ6O4vzoZZs-njueMbMKpjrBhgSiPvSDmlYTg0YPmumLO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 7.21 12 =3x4 =1.5x4 =4x4 =3x4 1 3 4 2 T1 T1 B1 ST1 0-5-12 6-6-12 2-9-10 6-0-15 3-3-6 3-3-6 6-6-121-11-140-0-41-8-3Scale = 1:20.8 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.16 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.13 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.10 Horiz(TL)0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 16 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-7-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 6-6-12. (lb) -Max Horiz 1=-49 (LC 12) Max Uplift All uplift 100 (lb) or less at joint(s) 1, 3, 9 except 4=-108 (LC 17) Max Grav All reactions 250 (lb) or less at joint(s) 1, 3, 9 except 4=555 (LC23) 7 7FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-128/340, 2-3=-130/365 BOT CHORD 1-4=-284/179, 3-4=-284/179 WEBS 2-4=-448/233 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb) 4=108. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 LAY01 2 12106478-12T Lay-In Gable Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:BnNJU7ssija9Vl8Wd2GoY5zoZb1-FvR0ZxNya0z2Ip1uyczSJy4iBQvJVLYUdiE2FVzQSdH WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x5 =3x5 =4x4 =3x4 =3x4 =4x6 =3x4 =4x4 =3x5 =3x4 11 10 9 8 7 1 2 6 53 12 15 1413 4 T1 T2 W1 W6 B1 B2 W4 W3 W4 W3W2 W5 0-7-12 -0-7-12 5-0-12 15-5-12 5-0-12 10-5-0 5-0-2 20-5-14 5-4-4 5-4-4 6-8-6 20-5-14 6-9-0 13-9-8 7-0-8 7-0-81-7-111-10-78-7-0Scale = 1:45.1 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL)-0.06 10-11 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.39 Vert(CT)-0.12 10-11 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.78 Horz(CT)0.02 7 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 102 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS (lb/size)7=714/0-1-6, (min. 0-1-8), 11=756/0-6-0, (min. 0-1-8) Max Horiz 11=255 (LC 15) Max Uplift 7=-151 (LC 17), 11=-173 (LC 16) Max Grav 7=807 (LC 2), 11=856 (LC 2) 8 8FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-12=-828/253, 12-13=-754/262, 4-13=-734/279, 4-14=-716/274, 14-15=-736/257, 5-15=-810/248, 2-11=-277/160 BOT CHORD 10-11=-178/731, 9-10=-54/520, 8-9=-54/520, 7-8=-135/635 WEBS 4-8=-152/326, 4-10=-164/362, 3-11=-783/107, 5-7=-825/157 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-7-12 to 2-4-4, Interior (1) 2-4-4 to 10-5-0, Exterior(2R) 10-5-0 to 13-5-0, Interior (1) 13-5-0 to 20-4-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 7. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 173 lb uplift at joint 11 and 151 lb uplift at joint 7. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 T01 36 12106478-12T Common Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:h4zOuDAc_VcftdAscRHlYHzoZeV-IXKF8GLi2PjK3WtVrBx_EX?JZcAn1GRBAOlyBdzQSdJ WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x4 =3x5 =4x4 =3x4 =3x4 =4x6 =3x4 =4x4 =3x5 =3x4 10 9 8 7 6 1 5 42 1411 1312 3 T1 T2 W1 W6 B1 B2 W4 W3 W4 W3W2 W5 5-4-4 5-4-4 5-0-12 15-5-12 5-0-12 10-5-0 5-0-2 20-5-14 6-8-6 20-5-14 6-9-0 13-9-8 7-0-8 7-0-81-7-111-10-71-7-118-7-0Scale = 1:43 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL)-0.06 9-10 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.39 Vert(CT)-0.12 9-10 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.81 Horz(CT)0.02 6 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 101 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS (lb/size)6=715/0-1-6, (min. 0-1-8), 10=715/ Mechanical, (min. 0-1-8) Max Horiz 10=245 (LC 13) Max Uplift 6=-151 (LC 17), 10=-153 (LC 16) Max Grav 6=808 (LC 2), 10=808 (LC 2) 9 9FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-833/253, 11-12=-759/262, 3-12=-737/279, 3-13=-717/273, 13-14=-737/256, 4-14=-811/247 BOT CHORD 9-10=-177/736, 8-9=-53/521, 7-8=-53/521, 6-7=-135/636 WEBS 3-7=-153/326, 3-9=-164/367, 2-10=-812/145, 4-6=-827/156 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-1-12 to 3-1-12, Interior (1) 3-1-12 to 10-5-0, Exterior(2R) 10-5-0 to 13-5-0, Interior (1) 13-5-0 to 20-4-2 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)Refer to girder(s) for truss to truss connections. 7)Provide mechanical connection (by others) of truss to bearing plate at joint(s) 6. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 10 and 151 lb uplift at joint 6. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 T02 14 12106478-12T Common Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:QWQjNCzVaUjt47KFeRxvP_zoZau-IXKF8GLi2PjK3WtVrBx_EX?JZcAn1GyBAOlyBdzQSdJ WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x5 =3x5 =4x4 =5x6 =4x6 =3x4 =4x4 =3x5 =3x5 11 10 9 8 1 7 62 53 12 15 13 14 4 T1 T1 W1 W1 B2B1 W4 W3 W4 W3W2 W2 0-7-12 -0-7-12 0-7-12 21-5-12 5-0-12 10-5-0 5-0-12 15-5-12 5-4-4 5-4-4 5-4-4 20-10-0 6-9-0 13-9-8 7-0-8 20-10-0 7-0-8 7-0-81-7-118-7-0Scale = 1:45.1 Plate Offsets (X, Y):[10:0-2-12,0-3-4] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL)-0.06 8-9 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(CT)-0.12 8-9 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.80 Horz(CT)0.02 8 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 103 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud *Except* W4:2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)8=767/0-6-0, (min. 0-1-8), 11=767/0-6-0, (min. 0-1-8) Max Horiz 11=256 (LC 15) Max Uplift 8=-176 (LC 17), 11=-176 (LC 16) Max Grav 8=869 (LC 2), 11=869 (LC 2) 10 10FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 3-12=-850/261, 12-13=-777/271, 4-13=-756/287, 4-14=-752/283, 14-15=-772/266, 5-15=-846/257, 2-11=-277/160,6-8=-277/160 BOT CHORD 10-11=-170/751, 9-10=-25/541, 8-9=-108/676 WEBS 4-9=-163/361, 4-10=-168/362, 3-11=-804/109, 5-8=-802/110 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-CExterior(2E) -0-7-12 to 2-4-4, Interior (1) 2-4-4 to 10-5-0, Exterior(2R) 10-5-0 to 13-5-0, Interior (1) 13-5-0 to 21-5-12 zone; cantilever left and right exposed ; end vertical leftand right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 176 lb uplift at joint 11 and 176 lb uplift at joint 8. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 T03 2 12106478-12T Common Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:bdatgz6P_s5JvpgMoFdVMJzoZaj-IXKF8GLi2PjK3WtVrBx_EX?JZcAc1G6BAOlyBdzQSdJ WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =3x4 =4x4 =1.5x4 =1.5x4 =4x4 =1.5x4 =1.5x4 =1.5x4 =3x4 =4x4 12 11 15 10 16 9 8 1 72635 13 14 4 T1 T1 W1 W1 B1 W3 W2 W2 3-0-0 3-5-4 0-7-12 -0-7-12 0-7-12 8-4-12 0-7-0 0-7-0 0-7-0 7-9-0 3-3-8 3-10-8 3-3-8 7-2-0 0-2-0 0-7-0 0-2-0 7-4-0 0-5-0 7-9-0 0-5-0 0-5-0 3-3-8 3-10-8 3-3-8 7-2-01-3-60-9-60-11-22-6-14Scale = 1:41.1 Plate Offsets (X, Y):[8:Edge,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.40 Vert(LL)0.06 10-11 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.30 Vert(CT)0.05 10-11 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.07 Horz(CT)0.00 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MR BCDL 10.0 Weight: 26 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 WEBS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-6-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)9=304/0-4-0, (min. 0-1-8), 11=304/0-4-0, (min. 0-1-8) Max Horiz 11=21 (LC 15) Max Uplift 9=-186 (LC 13), 11=-186 (LC 12) Max Grav 9=374 (LC 24), 11=374 (LC 23) 11 11FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-129/318, 3-13=-183/394, 4-13=-140/403, 4-14=-140/402, 5-14=-183/394, 5-6=-129/317 BOT CHORD 11-12=-300/133, 11-15=-300/133, 10-15=-300/133, 10-16=-300/133, 9-16=-300/133, 8-9=-300/133 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-7-12 to 2-4-4, Interior (1) 2-4-4 to 3-10-8, Exterior(2R) 3-10-8 to 7-2-0, Interior (1) 7-2-0 to 8-4-12 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design.5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 11 and 186 lb uplift at joint 9. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 T04 2 12106478-12T Common Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:UCPgDmmv1m1W?GNxWJ6O4vzoZZs-njueMbMKpjrBhgSiPvSDmlYTg0YPmumLO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =4x6 =6x6 =4x6 =4x6 =5x6 =5x6 =8x8 =5x6 =4x6 =4x6 =6x6 =4x6 26 25 24 23 22 21 20 19 18 17 16 151142 1333227124 5 11106 3128972930 8 T2 T1 T2 T1 W1 W1B1B1B2B2 W10 W9 W9 W4 W5 W6 W7 W8 W2 W8 W7 W6 W5 W4 W2W3W3 0-7-12 50-11-12 0-7-12 -0-7-12 3-0-2 3-0-2 3-0-2 50-4-0 3-3-6 6-3-8 3-3-6 47-3-14 6-3-8 18-10-8 6-3-8 12-7-0 6-3-8 37-9-0 6-3-8 44-0-8 6-3-8 25-2-0 6-3-8 31-5-8 6-3-8 25-2-0 6-3-8 18-10-8 6-3-8 12-7-0 6-3-8 37-9-0 6-3-8 44-0-8 6-3-8 31-5-8 6-3-8 6-3-8 6-3-8 50-4-01-4-69-9-0Scale = 1:83.6 Plate Offsets (X, Y):[2:0-0-11,0-2-0], [14:0-0-11,0-2-0], [16:0-3-0,0-2-0], [21:0-4-0,0-4-8], [26:0-3-0,0-2-0] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.27 Vert(LL)-0.20 21-22 >999 360 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.67 Vert(CT)-0.41 21-22 >999 240 TCDL 10.0 Rep Stress Incr YES WB 0.72 Horz(CT)0.14 16 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 329 lb FT = 20% LUMBER TOP CHORD 2x6 SPF No.2 *Except* T1:2x6 SP 2400F 2.0E BOT CHORD 2x6 SP 2400F 2.0E *Except* B2:2x6 SPF No.2 WEBS 2x4 SPF Stud *Except* W1:2x6 SP 2400F 2.0E, W10,W9,W7:2x4 SPFNo.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-7-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-9-1 oc bracing. WEBS 1 Row at midpt 7-21, 9-21 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)16=1810/0-6-0, (min. 0-1-11), 26=1810/0-6-0, (min. 0-1-11) Max Horiz 26=-123 (LC 21) Max Uplift 16=-504 (LC 13), 26=-504 (LC 12) Max Grav 16=2047 (LC 2), 26=2048 (LC 2) 12 12FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-657/201, 3-27=-3764/1057, 4-27=-3741/1065, 4-5=-3938/1121, 5-6=-3857/1131, 6-28=-3504/1062, 7-28=-3385/1064, 7-29=-2910/938, 8-29=-2847/956, 8-30=-2847/956, 9-30=-2910/938, 9-31=-3385/1064, 10-31=-3504/1062, 10-11=-3857/1131, 11-12=-3938/1121, 12-32=-3741/1065, 13-32=-3764/1056, 13-14=-657/201, 2-26=-525/242, 14-16=-525/242 BOT CHORD 25-26=-706/2612, 24-25=-920/3571, 23-24=-919/3682, 22-23=-919/3682, 21-22=-783/3269, 20-21=-768/3269, 19-20=-916/3682, 18-19=-916/3682, 17-18=-933/3571, 16-17=-739/2612 WEBS 8-21=-388/1439, 7-21=-908/339, 9-21=-908/339, 4-25=-459/200, 6-22=-582/230, 7-22=-79/495, 3-26=-2522/733, 9-20=-80/495, 10-20=-582/230, 12-17=-459/200, 13-16=-2522/733, 13-17=-246/1100, 3-25=-246/1100 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) -0-7-12 to 4-4-10, Interior (1) 4-4-10 to 25-2-0, Exterior(2R) 25-2-0 to 30-2-6, Interior (1) 30-2-6 to 50-11-12 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)This truss has been designed for greater of min roof live load of 12.0 psf or 2.00 times flat roof load of 15.4 psf on overhangs non-concurrent with other live loads. 6)All plates are 4x4 MT20 unless otherwise indicated. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 504 lb uplift at joint 16 and 504 lb uplift at joint 26. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 T05 7 12106478-12T Common Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:MTglbjX6_ii?JIa1II5eH5zoZNF-FvR0ZxNya0z2Ip1uyczSJy4gSQnsVBsUdiE2FVzQSdH WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =3x5 =3x6 =3x6 =5x6 =3x6 =3x6 =3x5 1 11 20 19 1817 16 1514 13 12 2625 2 10 3 9 8457 6 T2 T1 T2 T1 B1 B1B2 ST4 ST3 ST2 ST1 ST3 ST2 ST1 0-10-7 39-4-8 18-9-13 38-6-1 19-8-4 19-8-4 39-4-86-7-00-0-46-3-4Scale = 1:66.8 Plate Offsets (X, Y):[15:0-2-0,0-1-8], [17:0-2-0,0-1-8] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.55 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.47 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.36 Horiz(TL)0.01 20 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 120 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 39-4-8. (lb) -Max Horiz 1=118 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 1, 11, 13, 16, 19 except12=-201 (LC 17), 14=-130 (LC 17), 18=-131 (LC 16), 20=-202(LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 1, 11, 13, 19 except 12=609 (LC 36), 14=419 (LC 23), 16=507 (LC 2), 18=419 (LC 22), 20=609 (LC 35) 13 13FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-25=-367/358, 2-25=-163/431, 2-3=-82/379, 3-4=-32/358, 4-5=-21/402, 5-6=0/391, 6-7=0/391, 7-8=-13/402, 8-9=-24/358, 9-10=-70/379, 10-26=-145/431, 11-26=-154/358 BOT CHORD 1-20=-340/342, 19-20=-340/192, 18-19=-340/192, 17-18=-340/192, 16-17=-340/192, 15-16=-340/192, 14-15=-340/192, 13-14=-340/192, 12-13=-340/192, 11-12=-340/192 WEBS 6-16=-434/91, 5-18=-325/180, 2-20=-405/221, 7-14=-325/180, 10-12=-405/221 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-12 to 4-0-0, Interior (1) 4-0-0 to 19-9-0, Exterior(2R) 19-9-0 to 23-9-0, Interior (1) 23-9-0 to 39-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 1.5x4 MT20 unless otherwise indicated. 6)Gable requires continuous bottom chord bearing. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 16, 19, 13, 11 except (jt=lb) 18=130, 20=202, 14=130, 12=201. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V01 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:k0f7p6G?sbbDj0zKTy0f_OzoaKH-njueMbMKpjrBhgSiPvSDmlYRK0VmmqELO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =3x5 =1.5x4 =1.5x4 =1.5x4 =1.5x4 =4x4 =5x6 =1.5x4 =1.5x4 =1.5x4 =1.5x4 =3x5 1 7 12 11 10 9 8 221723 2 6 18 21 3 52019 4 T1 T1 B1 B1 ST3 ST2 ST1 ST2 ST1 0-10-7 31-4-8 14-9-13 30-6-1 15-8-4 15-8-4 31-4-85-3-00-0-44-11-4Scale = 1:54.8 Plate Offsets (X, Y):[10:0-3-0,0-3-0] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.56 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.46 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.28 Horiz(TL)0.01 12 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 89 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 31-4-8. (lb) -Max Horiz 1=93 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 1, 7, 9, 10, 11 except 8=-199(LC 17), 12=-199 (LC 16) Max Grav All reactions 250 (lb) or less at joint(s) 1, 7 except 8=600 (LC 36), 9=286 (LC 23), 10=627 (LC 2), 11=286 (LC 22), 12=600 (LC 35) 14 14FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-17=-317/424, 2-17=-150/510, 2-18=-77/393, 3-18=-66/461, 3-19=-20/417, 4-19=-14/477, 4-20=-15/477, 5-20=-21/417, 5-21=-67/461, 6-21=-78/393, 6-23=-151/510, 22-23=-152/438, 7-22=-159/424 BOT CHORD 1-12=-416/296, 11-12=-416/197, 10-11=-416/197, 9-10=-416/197, 8-9=-416/197, 7-8=-416/197 WEBS 4-10=-519/146, 3-11=-255/139, 2-12=-396/218, 5-9=-255/139, 6-8=-396/218 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-12 to 3-2-6, Interior (1) 3-2-6 to 15-9-0, Exterior(2R) 15-9-0 to 18-10-10, Interior (1) 18-10-10 to 31-5-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)All plates are 1.5x4 MT20 unless otherwise indicated. 6)Gable requires continuous bottom chord bearing. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 10, 11, 9 except (jt=lb) 12=199, 8=198. 9)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V02 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:bM3S69vk?eykMCt5IBqV9jzoZb_-njueMbMKpjrBhgSiPvSDmlYRA0VvmrULO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =3x5 =1.5x4 =1.5x4 =3x4 =4x4 =1.5x4 =1.5x4 =1.5x4 =3x5 1 9 8 7 6 5 191420 1815 2 41617 3 T1 T1 B1 B2 ST2 ST1 ST1 0-10-7 23-4-8 10-9-13 22-6-1 11-8-4 11-8-4 23-4-83-11-00-0-43-7-4Scale = 1:42.8 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.55 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.46 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.11 Horiz(TL)0.01 9 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 61 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS All bearings 23-4-8. (lb) -Max Horiz 1=72 (LC 16) Max Uplift All uplift 100 (lb) or less at joint(s) 1, 5, 7 except 6=-199 (LC 13), 9=-209 (LC 12) Max Grav All reactions 250 (lb) or less at joint(s) 1, 5 except 6=609 (LC23), 7=318 (LC 2), 9=643 (LC 22) 15 15FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-313/315, 14-15=-137/331, 2-15=-128/404, 2-16=-54/281, 3-16=-51/341, 3-17=-44/344, 4-17=-47/312, 4-18=-113/400, 18-20=-122/331, 19-20=-123/329, 5-19=-130/325 BOT CHORD 1-9=-314/292, 8-9=-314/163, 7-8=-314/163, 6-7=-314/163, 5-6=-314/163 WEBS 3-7=-330/112, 2-9=-447/229, 4-6=-430/224 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-12 to 3-0-12, Interior (1) 3-0-12 to 11-9-0, Exterior(2R) 11-9-0 to 14-9-0, Interior (1) 14-9-0 to 22-7-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except (jt=lb) 9=209, 6=198.8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V03 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:bM3S69vk?eykMCt5IBqV9jzoZb_-njueMbMKpjrBhgSiPvSDmlYRK0Vvmu9LO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 412 =4x4 =5x6 =1.5x4 =4x4 1 4 3 9 10 2 T1 T1 B1 ST1 0-10-7 15-4-8 6-9-13 14-6-1 7-8-4 7-8-4 15-4-82-7-00-0-42-3-4Scale = 1:30.8 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.71 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.62 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.18 Horiz(TL)0.01 4 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MSH BCDL 10.0 Weight: 36 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 9-3-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-10-1 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)1=107/15-4-8, (min. 0-1-13), 3=57/15-4-8, (min. 0-1-13), 4=866/15-4-8, (min. 0-1-13) Max Horiz 1=48 (LC 16) Max Uplift 1=-24 (LC 12), 3=-77 (LC 35), 4=-243 (LC 12) Max Grav 1=121 (LC 2), 3=180 (LC 23), 4=986 (LC 22) 16 16FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-307/604, 2-9=-297/681, 2-10=-290/639, 3-10=-299/604 BOT CHORD 1-4=-573/354, 3-4=-573/354 WEBS 2-4=-740/552 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Corner(3E) 0-0-12 to 3-0-12, Exterior(2N) 3-0-12 to 7-9-0, Corner(3R) 7-9-0 to 10-9-0, Exterior(2N) 10-9-0 to 14-7-3 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10; Min. flat roof snow load governs. Rain surcharge applied to all exposed surfaces with slopes less than 0.500/12 in accordance with IBC 1608.3.4. 5)Unbalanced snow loads have been considered for this design. 6)Gable requires continuous bottom chord bearing. 7)Gable studs spaced at 4-0-0 oc. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 24 lb uplift at joint 1, 77 lb uplift at joint 3 and 243 lb uplift at joint 4. 10)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V04 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:yKsL9sytpAb0Tzl35kPgsnzoZav-njueMbMKpjrBhgSiPvSDmlYOr0TPmt2LO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x5 =1.5x4 =4x4 =3x5 1 3 4 129 1110 2 T1 T1 B1 ST1 0-5-3 11-4-4 5-2-15 10-11-1 5-8-2 5-8-2 11-4-43-9-110-0-43-5-15Scale = 1:27.8 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.52 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.40 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.23 Horiz(TL)0.01 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 31 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)1=-13/11-4-4, (min. 0-1-8), 3=-13/11-4-4, (min. 0-1-8), 4=830/11-4-4, (min. 0-1-8) Max Horiz 1=99 (LC 13) Max Uplift 1=-79 (LC 23), 3=-79 (LC 22), 4=-239 (LC 16) Max Grav 1=47 (LC 35), 3=60 (LC 16), 4=939 (LC 2) 17 17FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-9=-226/372, 9-10=-216/397, 2-10=-211/481, 2-11=-209/481, 11-12=-215/397, 3-12=-225/372 BOT CHORD 1-4=-389/280, 3-4=-389/280 WEBS 2-4=-730/381 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-6 to 3-0-6, Interior (1) 3-0-6 to 5-8-8, Exterior(2R) 5-8-8 to 8-8-8, Interior (1) 8-8-8 to 11-4-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design.5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 1, 79 lb uplift at joint 3 and 239 lb uplift at joint 4. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V05 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:SjdYVPDIz1e6vxTKbgAr2pzoZQE-njueMbMKpjrBhgSiPvSDmlYRp0WrmsGLO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 812 =3x4 =4x4 =1.5x4 =3x4 1 3 4 2 T1 T1 B1 ST1 0-5-3 7-4-4 3-2-15 6-11-1 3-8-2 3-8-2 7-4-42-5-110-0-42-1-15Scale = 1:22.9 Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.18 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.18 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.08 Horiz(TL)0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 19 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF Stud BRACING TOP CHORD Structural wood sheathing directly applied or 7-5-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide.REACTIONS (lb/size)1=40/7-4-4, (min. 0-1-8), 3=40/7-4-4, (min. 0-1-8), 4=441/7-4-4, (min. 0-1-8) Max Horiz 1=62 (LC 15) Max Uplift 1=-4 (LC 23), 3=-15 (LC 12), 4=-110 (LC 16) Max Grav 1=88 (LC 22), 3=88 (LC 23), 4=498 (LC 2) 18 18FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-4=-349/224 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) 0-0-6 to 3-0-6, Interior (1) 3-0-6 to 3-8-8, Exterior(2R) 3-8-8 to 6-5-7, Interior (1) 6-5-7 to 7-4-10 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design.5)Gable requires continuous bottom chord bearing. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 1, 15 lb uplift at joint 3 and 110 lb uplift at joint 4. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V06 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:SjdYVPDIz1e6vxTKbgAr2pzoZQE-njueMbMKpjrBhgSiPvSDmlYX60aHmudLO2VVj3zQSdI WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. DE JOB# 82640-W1 Dansco Engineering LLC Date: 04/16/2021 WARNING – VERIFY DESIGN PARAMETERS AND READ NOTES BEFORE FABRICATION AND INSTALLATION!!! This truss design is adequate for the design parameters shown. Review and approval of design parameters is the responsibility of the building designer, not the truss designer or truss engineer. Permanent bracing requirements against out-of-plane buckling are noted/shown for individual truss members (and for the truss as a whole) subjected to gravity and wind loads. Additional permanent bracing design shall be the responsibility of the design professional of record. Temporary and erection bracing shall be the responsibility of the contractor. Reference ANSI/TPI-1, “National Design Standard for Metal Plate Connected Wood Truss Construction” and TPI/WTCA BCSI-06, “Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining and Bracing of Metal Plate Connected Wood Trusses” for additional information. 8 12 =3x4 =3x4 =3x4 1 3 2 T1 T1 B1 0-5-3 3-4-4 1-2-15 2-11-1 1-8-2 1-8-2 3-4-4 1-1-11 0-0-40-9-15Scale = 1:18.7 Plate Offsets (X, Y):[2:0-2-0,Edge] Loading (psf)Spacing 2-0-0 CSI DEFL in (loc)l/defl L/d PLATES GRIP TCLL (roof)20.0 Plate Grip DOL 1.15 TC 0.07 Vert(LL)n/a -n/a 999 MT20 197/144 Snow (Pf/Pg)15.4/20.0 Lumber DOL 1.15 BC 0.07 Vert(TL)n/a -n/a 999 TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL)0.00 3 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-MP BCDL 10.0 Weight: 7 lb FT = 20% LUMBER TOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 BRACING TOP CHORD Structural wood sheathing directly applied or 3-5-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing beinstalled during truss erection, in accordance with StabilizerInstallation guide. REACTIONS (lb/size)1=119/3-4-4, (min. 0-1-8), 3=119/3-4-4, (min. 0-1-8) Max Horiz 1=26 (LC 15) Max Uplift 1=-27 (LC 16), 3=-27 (LC 17) Max Grav 1=134 (LC 2), 3=134 (LC 2) 19 19FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design.2)Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=30ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) exterior zone and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3)TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.;Ce=1.0; Cs=1.00; Ct=1.10 4)Unbalanced snow loads have been considered for this design. 5)Gable requires continuous bottom chord bearing.6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 27 lb uplift at joint 1 and 27 lb uplift at joint 3. 8)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss Truss Type Qty Ply DWH - Gramercy Townhomes Building #10 V07 2 12106478-12T Valley Job Reference (optional) Run: 8.4 S 0 Apr 7 2020 Print: 8.420 S Dec 30 2020 MiTek Industries, Inc. Thu Apr 15 14:34:20 Page: 1 ID:SjdYVPDIz1e6vxTKbgAr2pzoZQE-njueMbMKpjrBhgSiPvSDmlYYq0b?mvsLO2VVj3zQSdI