IGA535 First Floor System
Start Spacing 19.2" O.C. Framing Connector Summary PlotIDQty Manuf Product Design Method Face Nails Top Nails Member Nails SkewBacker Blks Filler Web Stiff H1 2 Simpson HUS1.81/10 Designed 30- 10dx1.5- 10- 10d - No No No H2 5 Simpson IUS2.37/11.88 Designed 10- 10dx1.5- 2- 10dx1.5 - No No Yes Products PlotIDLength Product Plies Net Qty B26'-2 26' 0" 11 7/8" TJI 110 joist 2 6 B26' 26' 0" 11 7/8" TJI 110 joist 1 20 B22' 22' 0" 11 7/8" TJI 110 joist 1 9 B16' 16' 0" 11 7/8" TJI 110 joist 1 12 B4' 4' 0" 11 7/8" TJI 110 joist 1 2 BBk1 2' 0" 11 7/8" TJI 110 joist 1 15 R34' 34' 0" 11 7/8" TJI 360 joist 1 13 R24' 24' 0" 11 7/8" TJI 360 joist 1 5 R16' 16' 0" 11 7/8" TJI 360 joist 1 10 TS1 18' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 2 TS2-2 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 TS3 8' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 RM1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 18 Total Lengths Length Product 1104' 0" 11 7/8" TJI 110 joist 722' 0" 11 7/8" TJI 360 joist 64' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 288' 0" 1 1/8" x 11 7/8" TJ Rim Board LEVEL NOTES Current Date: 3/24/2021 File Name: 2021-0448DH Drees IGA-535 Sebastian D.jvl Level Name: 1st-Floor Framing Building Code - Design Methodology: IBC 2018 Members with Design Overridden: TJ-Pro Rating (Weighted Average): 43 Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 39, joist = B16'(i4552) Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 56, joist = B26'-2(i4609) FLOOR Floor Container: FC1 Use/Occupancy: ResidentialLivingAreas Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load TJ-Pro Rating Information: Weighted Average: 43 Directly Applied Ceiling: None Decking Attachment: Glue and Nail Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Gold Panel (0/24) T&G SF Perpendicular Partition: No Strapping at max 8' o.c.: None Blocking at max 8' o.c.: No Poured Flooring: No B4 A3 A3 A3 A3 A3A3 A3 A3 CS CS B4 BBO4 BBO13 BBO12 TS1TS1TS3 7' 7 1/2"9' 9"RM1RM1RM1RM1RM1 RM1RM1 RM1 RM1 RM1 RM1 RM1 RM1 Toilet Toilet Toilet BBO11 8" HVAC 9" HVAC 16' 11"15' 8 1/2" 15' 11" 16' 4" 12' 0" 8' 6"3' 10"14' 8 1/4" H1 H1 B26'-2B26'B26'-2B26'B26'-2Tub Tub Shower 9 5/8" 1' 7 3/16" 9 5/8" ToiletTS2-27 1/2"BBk1 38' 2" 63' 7"21' 1"BBk1 B4' B16'B16' R34' R24' B26'B26' B22' H2 R16'20' 4 1/2"24' 11"TS2-2 cantilevered to pickup of girder truss from above. Mechanical Chase Kitchen Island Hatch Legend TJI 110 TJI 210 TJI 230 TJI 360 TJI 560 Joists by Series Architectural Drawings Prepared By: Structural Drawings Prepared By:Drees HomesIGA-535; Sebastian DRev By Date CommentsDrawn By:DHChecked By: Release Date:3-24-21Job # 2021-0448DH Sheet 1 of 1 A complete Javelin ® framing plan requires the Trus Joist Installation Guide See the Trus Joist Installation Guide for Product Trademark Information SYMBOL LEGEND Bearing Length Requirements Point Load (Operator Added) Line Load (Operator Added) Area Load (Operator Added) Beam by Others Detail Callout Label (See Framer's Pocket Guide) Non-Load Bearing Wall Joist Under Wall Above BBO A10'UWALack of proper bracing during construction can result in serious accidents. Observe the following guidelines: WARNING NOTES: WARNING Joists are unstable until braced laterally Bracing Includes: Blocking Hangers Sheathing Rim Board Strut Lines Rim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. DO NOT walk on joists that are lying flat. DO NOT walk on joists until braced. INJURY MAY RESULT. Weyerhaeuser, Microllam, Parallam, TimberStrand, TJI, TJ, and Trus Joist are registered trademarks of Weyerhaeuser NR. ©2014 Weyerhaeuser NR Company. All rights reserved. 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI ® joists must be completely installed and properly nailed. 2. Laterial strength, like braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing of 1x4 (minimum) must be nailed to a braced end wall or sheathed area (as in note 2) and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - such as a worker or one layer of unnailed sheathing. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within 1/2" from true alignment. 4. Sheathing must be completely attached to each TJI® joist before additional loads can be placed on the system. Flat blocking panels between each joist. Nail to top plate with connections equivalent to floor panel schedule. Less than 5"E9 118" TJ ® Rim Board or 1 14" TimberStrand® LSL. Attach to joist with one 10d (0.131" x 3") nail at top and bottom flanges. Nail rim to blocking panel and blocking panel to plate with connections equivalent to floor panel schedule. TJI® Joist WARNING Joists are unstable until laterally braced Safety bracing required during installation 2'-0" Max 2" 2x6(min) or 1-18" x 4-1/2" (min) TJ® rim board nailed to top plate w/8d (0.113" x 2-3/8") nails at 6" o/c at panel edges and in field. Block must be full length between joists and tight to each flange 2416 span rated sheathing (716" min). Attach with 8d (0.113" x 2-38") nails at 6" o.c. along panel edges and field. Use pressure treated plywood for ground level cantilevers 1-18" TJ® rim board to match joist depth Lateral load transfer of detail = 220 PLF. Additional connections may be required to transfer loads from wall above First Floor System Scale: 1/4" = 1'0"These placement plans have been developed for the specificationof products based on project information provided. This service is solelyintended for product application assurance; and, is not intended tocircumvent the need for a design professional as determined by thebuilding code. The designer of record and/or builder/framer is responsibleto assure these drawings are compatible with the overall project.05/24/21