Loading...
HomeMy WebLinkAboutM004.0Truss Connector Total ListManufProduct QtyUSP JUS267USP RT7A*120C01A01E02E01B01B03(7) JUS26 D04 M02 M02M03M02V17V12V07V06V05V04V03V02V01V14V18V15V11V08V16V13V10(2) C02(10) A02(6) A03 (9) A04 (2) M01(7) B02(2) D01 (2) D02 (3) D03(7) M03(6) M0430-04-0015-08-00 14-08-0011-00 11-0011-00 86-08-001-04-005-00-00 23-06-08 17-09-08 12-00-00 21-06-00 5-06-0011-0011-0011-0011-0011-0011-0030-04-0010-04-00 20-00-0011-0011-0011-00IMPORTANT THISDRAWINGISFOR FIELD PLACEMENT OF INDIVIDUALCOMPONENTSONLY,AND DOESNOT CONSTITUTE ANENGINEERED DOCUMENT..RoofArea: OverhangLength: Eave Length: HipLength: ValleyLength: Ridge Length: SHEETNUMBER:R1.1RoofTrussPlacementPlanSCALE: NTSJob#:24389-24389APO#:Date:4/27/2021Drawn By: MMDesigner: MMChk'd By:ROOF LOADS:TCLL: 20.0 lb/ft²TCDL: 10.0 lb/ft²BCLL: 0.0 lb/ft²BCDL:10.0 lb/ft²Building Code: IRC 2012Wind Speed: 115 mphOn-Center Spacing: 24"U.N.O.5808.47 SF272.23 LF385.75 LF2.75 LF240.57 LF246.88 LFROOFDATATHISLAYOUTISINTENDED FORTHE PURPOSE OF TRUSSLOCATION AND PLACEMENTONLY.REFERTO THE BUILDINGPLANSFORACTUAL BUILDINGCONSTRUCTION.TG177 RF B14227 Larson DrCarmel, Indiana46033ROOFTRUSSPLACEMENTPLAN24389-24389A1850 N Graham RoadFranklin, Indiana 46131Office:(317) 346-4274Fax: (317) 346-0916NOTE PROPER BEARINGAND BEARINGDESIGN INCLUDINGANCHORAGE,ISTHE RESPONSIBILITY OF THE BUILDINGDESIGNER,ARCHITECT AND / OR BUILDINGENGINEER. REFER TOINDIVIDUAL TRUSSDESIGNSFOR REACTIONS,MINIMUMREQUIRED BEARINGSIZE,UPLIFT,AND ADDITIONAL LOADS.84 COMPONENTSDOESNOT ASSUME RESPONSIBILITY IN THESEAREASOF CONCERN.BRACING ERECTION,TEMPORARY,AND PERMANENT BRACINGISTHERESPONSIBILITY OF THE CONTRACTOR AND / OR BUILDINGDESIGNER. REFER TO INDIVIDUAL TRUSSDESIGNSFORADDITIONAL BRACINGREQUIREMENTS. REFER TO BCSI-B1SUMMARY SHEET. THE STRUCTURAL BUILDINGCOMPONENTSASSOCIATION COMMENTARY,AND RECOMMENDATIONSFORHANDLING,INSTALLING&BRACINGMETAL PLATE CONNECTEDWOOD TRUSSES. www.sbcindustry.comINSTALLATION DO NOT CUT,DRILL,OR ALTER TRUSSES. ANY QUESTIONSCALL84 COMPONENTS. PROPER INSTALLATION,AND HANDLINGOFCOMPONENTSISTHE RESPONSIBILITY OF THE ERECTINGCONTRACTOR. 84 COMPONENTSMUST BE NOTIFIED OF ANYPROBLEMS,AND AFFORDED THE OPPORTUNITY TO REVIEW,ANDMAKE NECESSARY CORRECTIONS,OR NO BACK CHARGESWILLBE ACCEPTED OR APPROVED.WARNINGWARNINGS,AND INSTRUCTIONSFOR ERECTIONOF COMPONENTSARE INCLUDED IN THE DELIVERY PACKAGE. KEEPTHISINFORMATION ON THE JOB SITE. THESE DOCUMENTSWILLALSO BE NEEDED FOR JOB SITE INSPECTION. MISUSE ANDIMPROPER INSTALLATION OF COMPONENTSMAY RESULT INFAILURE,BODILY INJURY,LOSSOF PROPERTY,AND / OR LIFE. 05/20/21