HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG160Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 04/20/2021Tribeca
24449
Sheet
1 of 1
Main Floor System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. Spacing 11 7/8" TJI Joists
24" O.C. Spacing
Framing Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H1 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes
H2 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 2 No Yes
H3 1 Simpson SUR410 Designed 14- SD9112 - 6- SD9112 45 (R) - No No No
H4 4 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes
H5 1 Simpson SUL1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (L) - No No Yes
H6 1 Simpson SUR1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (R) - No No Yes
Products
PlotID Length Product Plies Net Qty
FJ1 18' 0" 11 7/8" TJI 110 joist 1 8
FJ2 10' 0" 11 7/8" TJI 110 joist 1 2
FJ3 4' 0" 11 7/8" TJI 110 joist 1 7
FJ4 36' 0" 11 7/8" TJI 360 joist 1 2
FJ5 20' 0" 11 7/8" TJI 360 joist 2 2
FJ6 18' 0" 11 7/8" TJI 360 joist 1 6
FJ7 24' 0" 11 7/8" TJI 560 joist 1 5
FJ8 20' 0" 11 7/8" TJI 560 joist 1 1
FJ9 18' 0" 11 7/8" TJI 560 joist 1 2
BM1 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2
BM2 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6
BM3 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
BM4 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1
BM5 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
Ca1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 12
Accessories
PlotID Length Product Plies Net Qty
9 1/8" 7/8" x 2 5/16" Web Stiffeners 1 4
1' 0" 5/8" or 3/4" Backer Blocks 1 4
9 1/8" 5/8" x 2 5/16" Web Stiffeners 1 16
23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 38
Blocking
PlotID Length Product Plies Net Qty
Bk1 2' 0" 11 7/8" TJI 110 joist 1 27
LEVEL NOTES
Current Date: 4/20/2021
File Name: tg160_24449.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2006
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 42
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 35, joist = FJ4(i9048)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 65, joist = FJ2(i9063)
FLOOR
Floor Container: FC1
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 42
Directly Applied Ceiling: Varies
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
A3
A3
A3
A3
A3
H2
H2
B1W
B1
A3
E1
E1
BM3
BM2BM2 BM1
FJ7
FJ7
FJ7
FJ7
FJ5
FJ4
FJ8
FJ4
FJ6
FJ6
FJ6
FJ6
FJ6
FJ9
FJ1
FJ1
FJ1
FJ1
FJ1
FJ1
FJ1
FJ1
FJ2
FJ2
Ca1
Ca1
Ca1
Ca1Ca1Ca1 Ca1Ca1
Ca1 Ca1 Ca1Bk1 Bk1Bk1FJ3FJ3FJ3FJ3Bk1
VO1
VO2
VO3
VO4
FJ3FJ3FJ7
Ca11' 4" 1' 4"2' 0"
FJ6
FJ9 Bk1H1
Ca1Ca1
Ca1 BM2H2FJ3 1' 11 7/8"1' 6 7/8"10 7/8" 8' 8 3/8" 1' 5 7/8"7"1' 0 15/16"4 1/2"10"7' 10 7/16"BM5BM4
H4H4H4H4H6H5 H3 Flush beam depth greater than floor joist depth. Verify all
loading and framing conditions prior to construction.An additional 8 PSF area dead load has been addedto account for tile load in the MBA on this floor.There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
05/26/21