Loading...
HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN  46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design.  Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG160Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 04/20/2021Tribeca 24449 Sheet 1 of 1 Main Floor System Not to Scale Confirm this layout with the builder and designer of record.  Make sure all discrepencies are corrected before ordering floor system. All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. Spacing 11 7/8" TJI Joists 24" O.C. Spacing Framing Connector Summary PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff H1 1 Simpson U14 Designed 14- 10dx1.5 - 6- 10dx1.5 - - 2 No Yes H2 1 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - 2 No Yes H3 1 Simpson SUR410 Designed 14- SD9112 - 6- SD9112 45 (R) - No No No H4 4 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- 10dx1.5 - - No No Yes H5 1 Simpson SUL1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (L) - No No Yes H6 1 Simpson SUR1.81/11 Designed 16- 10dx1.5 - 6- 10dx1.5 45 (R) - No No Yes Products PlotID Length Product Plies Net Qty FJ1 18' 0" 11 7/8" TJI 110 joist 1 8 FJ2 10' 0" 11 7/8" TJI 110 joist 1 2 FJ3 4' 0" 11 7/8" TJI 110 joist 1 7 FJ4 36' 0" 11 7/8" TJI 360 joist 1 2 FJ5 20' 0" 11 7/8" TJI 360 joist 2 2 FJ6 18' 0" 11 7/8" TJI 360 joist 1 6 FJ7 24' 0" 11 7/8" TJI 560 joist 1 5 FJ8 20' 0" 11 7/8" TJI 560 joist 1 1 FJ9 18' 0" 11 7/8" TJI 560 joist 1 2 BM1 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2 BM2 4' 0" 1 3/4" x 7 1/4" 2.0E Microllam LVL 2 6 BM3 20' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 BM4 10' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 1 1 BM5 6' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2 Ca1 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 12 Accessories PlotID Length Product Plies Net Qty 9 1/8" 7/8" x 2 5/16" Web Stiffeners 1 4 1' 0" 5/8" or 3/4" Backer Blocks 1 4 9 1/8" 5/8" x 2 5/16" Web Stiffeners 1 16 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 38 Blocking PlotID Length Product Plies Net Qty Bk1 2' 0" 11 7/8" TJI 110 joist 1 27  LEVEL NOTES  Current Date:  4/20/2021  File Name:  tg160_24449.jvl  Level Name:  Second Floor System  Building Code - Design Methodology:  IBC 2006  Members with Design Overridden:  TJ-Pro Rating (Weighted Average):  42     Minimum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 35, joist = FJ4(i9048)     Maximum Level TJ - Pro Rating & Joist:  TJ-Pro rating = 65, joist = FJ2(i9063)  FLOOR  Floor Container:  FC1  Use/Occupancy:  ResidentialLivingAreas  Floor Area Loading is:  40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load  Operator Added Additional Loads  Maximum Allowed Deflection:  L/480 Live Load & L/240 Total Load  TJ-Pro Rating Information:      Weighted Average:  42      Directly Applied Ceiling:  Varies      Decking Attachment:  Glue and Nail      Decking Material:  23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF      Perpendicular Partition:  No      Strapping at max 8' o.c.:  None      Blocking at max 8' o.c.:  No      Poured Flooring:  No A3 A3 A3 A3 A3 H2 H2 B1W B1 A3 E1 E1 BM3 BM2BM2 BM1 FJ7 FJ7 FJ7 FJ7 FJ5 FJ4 FJ8 FJ4 FJ6 FJ6 FJ6 FJ6 FJ6 FJ9 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ1 FJ2 FJ2 Ca1 Ca1 Ca1 Ca1Ca1Ca1 Ca1Ca1 Ca1 Ca1 Ca1Bk1 Bk1Bk1FJ3FJ3FJ3FJ3Bk1 VO1 VO2 VO3 VO4 FJ3FJ3FJ7 Ca11' 4" 1' 4"2' 0" FJ6 FJ9 Bk1H1 Ca1Ca1 Ca1 BM2H2FJ3 1' 11 7/8"1' 6 7/8"10 7/8" 8' 8 3/8" 1' 5 7/8"7"1' 0 15/16"4 1/2"10"7' 10 7/16"BM5BM4 H4H4H4H4H6H5 H3 Flush beam depth greater than floor joist depth. Verify all loading and framing conditions prior to construction.An additional 8 PSF area dead load has been addedto account for tile load in the MBA on this floor.There are different joist series of the same depth specified on this floor system.  Verify when installing that the proper TJI® joists are used in the appropriate area. 05/26/21