HomeMy WebLinkAboutM002.0Indianapolis Design Center352 South County Road 300 EDanville, IN 46122317-745-9984These placement plans have been prepared with the specifications of TrussJoist products based on project information provided. This service is solely intendedfor product application assurance; and, is not intended to circumvent the needfor a design professional as determined by the building codes. The designerof record and/or builder/framer is responsible to assure these drawings arecompatible with the overall project. These documents are not intended to replacethe building plan (which should be used to determine bearing placement).Please insure measurements of the foundation match those provided at the timeof design. Builder is responsible to place load bearing members in load path.Architectural Drawings Prepared By: Structural Drawings Prepared By: 84 Lumber FranklinKevin BeherPyatt BuildersTG86Rev. By Date CommentsDrawn By:DWChecked By: Date:CM 04/01/2021Chelsea
24248
Sheet
1 of 1
Main Floor System
Not to Scale
Confirm this layout with the builder and designer of record. Make
sure all discrepencies are corrected before ordering floor system.
All Dimensions are Approximate and Must Be Field Verified. 11 7/8" TJI Joists 24" O.C. SpacingFraming Connector Summary
PlotID Qty Manuf Product Design Method Face Nails Top Nails Member Nails Skew Slope Backer Blks Filler Web Stiff
H101 7 Simpson IUS1.81/11.88 Designed 10- 10dx1.5 - 2- Strong-Grip - - 2 No No
Products
PlotID Length Product Plies Net Qty
FJ101 22' 0" 11 7/8" TJI 110 joist 1 2
FJ102 18' 0" 11 7/8" TJI 110 joist 1 4
FJ103 16' 0" 11 7/8" TJI 110 joist 1 3
FJ104 12' 0" 11 7/8" TJI 110 joist 1 2
FJ105 10' 0" 11 7/8" TJI 110 joist 1 1
FJ106 4' 0" 11 7/8" TJI 110 joist 1 2
FJ107 36' 0" 11 7/8" TJI 360 joist 1 2
FJ108 20' 0" 11 7/8" TJI 360 joist 1 2
FJ109 18' 0" 11 7/8" TJI 360 joist 1 9
FJ110 16' 0" 11 7/8" TJI 360 joist 1 4
FJ111 22' 0" 11 7/8" TJI 560 joist 1 5
FJ112 18' 0" 11 7/8" TJI 560 joist 1 1
BM101 20' 0" 1 3/4" x 16" 2.0E Microllam LVL 2 2
BM102 20' 0" 1 3/4" x 14" 2.0E Microllam LVL 2 2
BM103 12' 0" 1 3/4" x 11 7/8" 1.55E TimberStrand LSL 2 2
Ca101 16' 0" 1 1/8" x 11 7/8" TJ Rim Board 1 12
Accessories
PlotID Length Product Plies Net Qty
1' 0" 5/8" or 3/4" Backer Blocks 1 14
23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF 1 39
Blocking
PlotID Length Product Plies Net Qty
Bk101 2' 0" 11 7/8" TJI 110 joist 1 21
LEVEL NOTES
Current Date: 4/1/2021
File Name: tg86_24248.jvl
Level Name: Second Floor System
Building Code - Design Methodology: IBC 2006
Members with Design Overridden:
TJ-Pro Rating (Weighted Average): 43
Minimum Level TJ - Pro Rating & Joist: TJ-Pro rating = 31, joist = FJ107(i3243)
Maximum Level TJ - Pro Rating & Joist: TJ-Pro rating = 62, joist = FJ102(i3308)
FLOOR
Floor Container: FC2
Use/Occupancy: ResidentialLivingAreas
Floor Area Loading is: 40.0 lb/ft² Live Load & 10.0 lb/ft² Dead Load
Operator Added Additional Loads
Maximum Allowed Deflection: L/480 Live Load & L/240 Total Load
TJ-Pro Rating Information:
Weighted Average: 43
Directly Applied Ceiling: Gypsum 1/2"
Decking Attachment: Glue and Nail
Decking Material: 23/32"x48"x96" Weyerhaeuser Edge Panel (0/24) T&G FF
Perpendicular Partition: No
Strapping at max 8' o.c.: None
Blocking at max 8' o.c.: No
Poured Flooring: No
E1
B4
B4
B1
B1
A3
A3
A3
A3
A3
A3
A3
H2
H2
H2
H2
H2
H2
B1
B1
PBO1
BM102
PBO2 PBO3BBO4BBO5 BBO8BBO10
BM101
BM103FJ104
FJ101
FJ101
FJ102
FJ102
FJ102
FJ103
FJ103
FJ105
FJ102
FJ109
FJ109
FJ109
FJ109
FJ109
FJ109
FJ109
FJ112
FJ109
FJ110
FJ110
FJ110
FJ110
FJ107
FJ107
FJ109
Ca101
Ca101
Ca101
Ca101Ca101 Ca101Ca101Ca101Ca101 Bk101 VO1
VO2
VO3
VO4
FJ111Bk101FJ111
FJ108
Bk101FJ108
1' 0" 2' 0" 1' 0" 2' 0" 1' 0" FJ106Ca101 Ca101FJ106H101H101 FJ104
Bk1018 7/8"FJ103H101
H101
H101
H101 H10110 7/8" 1' 1 1/8"1' 3 1/8"Bk101Ca101Ca101
5' 9 15/16"
1' 1 3/8"
Ca102
11" 1' 6 9/16"1' 7 1/2"11 1/4"6' 0"5' 7"2' 4 1/2"FJ111
FJ111
FJ111
An additional 8 PSF area dead load has been added
to account for tile load in the MBA on this floor.
Flush beam depth greater than floor joist depth. Verify all
loading and framing conditions prior to construction.
There are different joist series of the same
depth specified on this floor system. Verify
when installing that the proper TJI® joists
are used in the appropriate area.
(4) 2x6 Beam Jacks
05/26/21