HomeMy WebLinkAboutA200.0SD
5
A500
2
A500
1
A500
+ 116' - 11 1/8"
ATTIC BEYOND
ATTIC BEYOND
ATTIC BEYOND ATTIC BEYOND
204
204
204
EQ EQ
15' - 8" 16' - 0" 16' - 0" 4' - 3"
EQ EQ
10' - 10 3/8"
6"
SMOKE DETECTOR
WH
F
4x1 FLUORESCENT
LIGHTS
SLOPED CEILING
5
A500
2
A500
4
A500
1
A500
3
A500
3' - 6"
5' - 8"
3' - 6"
5' - 8"
3' - 6"
3' - 1 3/4" 3' - 1 3/4"
EQ EQ EQ EQ EQ EQ
MEZZANINE
STORAGE
--
FURN.
WH
PREFFERED LOCATION
OF FIRE PROTECTION
VALVES, ETC
TWO QUADS ON A
DEDICATED CIRCUIT
FOR AV NEEDS
205
205
205
12' - 3 3/4" 19' - 2 1/8"
55' - 3 1/8"
205
GENERAL FLOOR PLAN NOTES
GENERAL CONTRACTOR AND / OR SUBCONTRACTORS ARE RESPONSIBLE FOR EXAMINING
AND CONFIRMING ALL SUBSTRATE CONDITIONS WHERE NEW MATERIALS ARE APPLIED.
SUBSTRATE SHALL BE SMOOTH, FREE OF DEFECTS AND SHALL CONFORM TO THE
REQUIREMENTS OF THE FINISHED MATERIAL MANUFACTURER'S RECOMMENDATION.
DO NOT SCALE DRAWINGS.
ALL DIMS TO BE FIELD VERIFIED. ARCHITECT TO BE NOTIFIED OF ANY DISCREPANCIES.
THE WORD "ALIGN" AS USED IN THESE DOCS SHALL SUPERCEDE ANY DIMENSIONAL
INFO INDICATED. IF DISCREPANCIES OCCUR, NOTIFY THE ARCHITECT IMMEDIATELY.
TYPICAL DIMENSIONS ARE TO THE FACE OF WOOD STUD, OR TO CENTER LINE OF STUD.
REFER TO PLAN DETAILS FOR ADDITIONAL DIMENSIONS.
ALL ANGLES SHOWN ARE 45°, 90°, OR 135° UNLESS NOTED OTHERWISE.
DO NOT SCALE THE DRAWINGS. WORKING FROM ESTABLISHED LINES AND POINTS,
ESTABLISH AND MAINTAIN DEPENDABLE MARKERS FOR LINES AND LEVELS OF WORK.
CALCULATE DIMS AND MEASURE FOR LAYOUT OF WORK. RECORD DEVIATIONS (IF ANY)
FROM DWG INFO ON EXIST CONDITIONS AND REVIEW WITH ARCHITECT/ENGINEER AT
TIME OF DISCOVERY.
FOLLOW WRITTEN DIMS AND LAYOUT POINTS ONLY. CONTRACTOR SHALL EXERCISE
SPECIAL CARE IN THE VERIFICATION OF ALL CONDITIONS AND DIMS IN THE LAYOUT OF
HIS WORK THE ALIGNMENT IN COORDINATION OF HIS WORK ITSELF AND OTHER
ADJACENT WORK IS OF PRIMARY IMPORTANCE AND SHALL TAKE PRECEDENCE OVER
DIMENSIONS, ESPECIALLY THOSE INDICATED AS APPROXIMATE. CONTRACTOR SHALL LAY
OUT AND VERIFY HIS WORK TO ENSURE ALIGNMENT AND FIT AND REPORT ANY
DISCREPANCIES IMMEDIATELY TO HIS SUPERINTENDENT AND THE ARCHITECT BEFORE
PROCEEDING OR PROCEED AT CONTRACTOR'S OWN RISK.
1
3
4
5
6
7
8
9
SLOPING CONCRETE SLAB TO FLOOR DRAINS IS OF PRIMARY IMPORTANCE AND SHOULD
TAKE PRECEDENCE OVER DIMENSIONS, ESPECIALLY THOSE INDICATED AS APPROXIMATE.
CONTRACTOR SHALL LAY OUT AND VERIFY HIS WORK TO ENSURE ALIGNMENT AND FIT,
AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE.
10
THE GENERAL CONTRACTOR IS TO PROVIDE PROTECTION TO ANY COMPLETED WORK,
DURING CONSTRUCTION BY WHATEVER MEANS NECESSARY TO
MAINTAIN ANY COMPLETED FINISHES IN NEW CONDITION TO THE POINT OF OWNER MOVE-
IN AND ACCEPTANCE. ANY DAMAGED WORK, SCRATCHED, MARKED OR IN ANY WAY
IMPAIRED MATERIAL FOUND BY THE OWNER'S WILL BE REPLACED AT NO EXTRA COST TO
THE OWNER.
11
ALL PARTITIONS INDICATED ON THE FLOOR PLAN TO BE 2X4 WOOD STUD WITH 5/8"
DRYWALL UNLESS NOTED OTHERWISE.
13
ALL WOOD IN DIRECT CONTACT WITH CONCRETE TO BE PRESERVATIVE ROT RESISTANT
TREATED WOOD U.N.O.
18
SEE DOOR & FINISH SCHEDULE FOR ALL SCHEDULED DOORS, FRAMES TYPES, HARDWARE
AND DETAILS.
19
ALL FOUNDATION WALLS IN EXCAVATED AREAS TO BEAR ON AND BE FORMED BY
CLEANED, UNDISTURBED, VIRGIN SUB-SOIL.
22
ALL PENETRATIONS THROUGH RATED PARTITIONS (MECH, ELEC, AND PLUMB.) TO BE
FILLED WITH FIRE SAFING INSUL AND FIRE STOP SEALANT PER UL DESIGNS INDICATED.
27
THE ROOF FRAMING, FLOOR FRAMING, AND BEAM SIZES WILL BE DESIGNED BY SUPPLIER
SELECTED FOR PROJECT.
29
30 ALL EXTERIOR WINDOW AND DOOR HEADERS TO BE 2"X12"
ALL BEDROOM FLOORING TO BE CARPET. ALL OTHER AREAS TO USE LVT FLOORING
UNLESS NOTED OTHERWISE.
31
KEYNOTE LEGEND
PROVIDE ROOF CAVITY INSULATION VENTS WHERE GYPSUM BOARD CEILING
PREVENTS ATTIC AIRFLOW
ATTIC ACCESS DOOR. TYPE, SIZE, AND FINAL LOCATION TO BE VERIFIED WITH
OWNER.
NO. DESCRIPTION
204
205
32 ALL THERMOSTATS TO BE LOCKABLE
33 ALL DOOR PULLS TO BE OF AN ADA COMPLIANT LEVER TYPE
34 ALL TOILETS TO BE FLOOR MOUNT, ADA HEIGHT (RIM AT 17"-19" A.F.F.)
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNED
DRAWN
APPROVED
BSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
C:\Users\BChapman\21730002-ARCH_BSALS_CENTRAL_v2018_REVISED PLAN_BChapman.rvt
09/18/20 1:48:19 PM
21730002
Approver
Author
Designer
A200
MEZZ/ATTIC PLAN
10-BED MEMORY CARE
HOME
STORY
COTTAGE
18 SEPT 2020
CLIENT PROJECT NO. - 21730002
1/4" = 1'-0"
1
MEZZANINE
1/4" = 1'-0"
3
SECOND FLOOR MEZZANINE - ARCHITECTURAL PLAN
MARK DATE DESCRIPTION
05/27/21