HomeMy WebLinkAboutA300.00ASPHALT SHINGLES WP ROOF SHEATHING 15lb FELT ICE & WATER SHIELD EAVE FLASHING BY SHT. MTL. ROOFING CONT'R PRE-FAB WOOD TRUSSES @ 24" O.C. FASCIA BOARD CONT. SOFFIT VENT SMOOTH FCP SOFFIT AIRFLOW AIRFLOW W.P. . . AIR GAP 1" MIN. ROOF TRUSSES ROOF TRUSSES BLOCKING AS REQ'D EA SIDE ICE & WATER SHIELD. ON BOTH SIDES OF ALL RIDGES TYP. PLYWD. ROOF SHEATHING RIDGE VENT W/ WIND BAFFLE & RIDGE CAP SHINGLES PROVIDE MIN.0.12 SQ FT OF NET FREE VENT AREA PER LINEAR FOOT @ RIDGE. ROOF SHINGLES FELT UNDERLAYMENT NOTE: NET FREE VENT AREA FOR RIDGE VENT SHALL NOT BE ANY GREATER THAN 50% OF THE TOTAL NET FREE VENT AREA. GUTTER ID W (WIDTH) D (DEPTH) 3/4". B (DEPTH) A (WIDTH) GUTTER "A" GUTTER "B" W (WIDTH SIZE): D (DEPTH SIZE): 4" 5" DOWNSPOUT ID: D.S. "A" (X" NOMINAL) D.S. "B" (X" NOMINAL) A (WIDTH SIZE): 4" 5" B (DEPTH SIZE): 3" 4" 2" 3" NOTE: SEE ELEVATIONS FOR GUTTER & DOWNSPOUT MATERIAL PLAIN RECTANGULAR DOWN SPOUT REMOVABLE H/D SCREEN GUTTER THICKNESS PER SMACNA TABLE 1-5 NOTE: EXPANSION JOINT COVER PLATE AND EXPANSION JOINT SIZED PER SMACNA . B . MIN PER SMACNA ROOFING NAILS FASTENED AT APPROXIMATELY 6" TO 10" ON CENTER (O.C.) SLOPE PERIMETER RAKE DRIP- EDGE FLASHING METAL(INSTALL OVER UNDERLAYMENT AT RAKE.) DOWNSLOPE PERIMETER EAVE DRIP-EDGE FLASHING METAL. FORMED DRIP-EDGE FASCIA BOARD OPTIONAL: GUTTER BRACKET K-STYLE GUTTER FABRICATED GUTTER SPACER, OR FERRULE AND SPIKE OPTIONAL: COMPATIBLE SEALANT RECOMMENDED ICE & WATER SHIELD NOTES: 1. PERIMETER DRIP EDGE METAL FLASHING IS SUGGESTED TO BE A MINIMUM OF 26- GAUGE PER-FINISHED/PAINTED GALVANIZED STEEL, 16-OZ. COPPER, .032-INCH THICK PER-FINISHED ALUMINUM, OR AN EQUIVALENT LONGEVITY, CORROSION-RESISTANT METAL. 2. THE PERIMETER ON THE ROOF DECK SHOULD PROVIDE A CONTINUOUS SOLID WOOD NAILING SURFACE OVER WHICH TO APPLY THE SHEET METAL DRIP -EDGE FLASHING. 3. THE VERTICAL-FACE FLANGE OF SHEET METAL DRIP-EDGE FLASHING SHOULD BE OF SUFFICIENT LENGTH TO PERMIT WATER TO DRIP OFF THE ROOF, AND INTO GUTTER (IF PRESENT), WITHOUT AFFECTING THE UNDERLYING CONSTRUCTION DURING TIMES OF NO WIND. 4. THE HORIZONTAL FLANGE (I.E. ROOF SIDE) OF SHEET METAL DRIP-EDGE FLASHING SHOULD EXTEND APPROXIMATELY 2" TO 3" MINIMUM ONTO THE ROOF. ASPHALT- SATURATED FELT,OR OTHER APPROVED UNDERLAYMENT PLYWOOD OR STRUCTURAL WOOD SHEATHING TYP SIDING WALL CLADDING UNDERLAYMENT (By others. Lap over step flashing and up-turned roof underlayment.) METAL 'Z'-SHAPED COUNTERFLASHING STEPFLASHING (See Detail S-9 CRICKET VALLEYS SLOPED TO DRAIN WOOD-FRAMED AND SHEATHED CRICKET BENEATH MEMBRANE FLASHING GRANULATE-SURFACED MEMBRANE CRICKET FLASHING PLY(S) (Extend upper end of flashing 18" min. upslope under shingles. See note 2.) NOTES : 1. Detail drawn showing laminated shingle. Also applies to other styles. 2. In cold climates, where snow and ice are common it is recommended as an ice-dam protection membrane at all potential ice damming locations such as eaves, valleys, crickets, around penetrations, and rake edges. Consult local Building code requirements. 3. A cricket flashing is recommended for rising walls and other through-roof penetrations greater than 24" in width to promote positive runoff. Extend flanges 6" minimum up wall and a minimum of 18" upslope (24" minimum is suggested in ice and snow regions). Consider holding course of shingle(s) upslope from back and upper side of cricket to promote drainage. 4. Sheet metal step flashings are suggested to be a minimum of 26-gauge pre-finished/painted galvanized steel, 16 oz.copper, .032-inch thick pre-finished aluminum, or an equivalent longevity non-corrosive metal. 5. Consider specifying the extension of roofing underlayment vertically up the wall so that it is over lapped by the wall cladding underlayment. 6. Dimensions shown are recommended minimums and are intended to be approximate to allow for reasonable tolerances due to field conditions. 7. The profile of specific components, their configuration or sequencing, can vary with the roof system, with climatic differences, and regional or area practices. DOWNSLOPE PERIMETER EAVE DRIP-EDGE FLASHING METAL (Install underneath underlayment at eave.) LEADING EDGE PLUS STARTER COURSE START FIRST COURSE WITH FULL SHINGLE TYPICAL EXPOSURE PER SHINGLE MFGR. 4" MINIMUM END LAP 2" MINIMUM SIDE LAP SECURE WITH CODE-REQUIRED NUMBER OF NAILS SELF-ADHERED ICE & WATER MEMBRANE (extend minimum 24" inside exterior wall line. SELF-ADHERED ICE & WATER MEMBRANE AT ALL VALLEYS TYP. APPROXIMATELY 6" LAP ASPHALT-SATURATED FELT, OR OTHER APPROVED UNDERLAYMENT NOTES: 1. AN ICE & WATER PROTECTOR MEMBRANE AS AN ICE-DAM PROTECTION MEMBRANE AT ALL POTENTIAL ICE DAMMING LOCATIONS SUCH AS DOWNSLOPE EAVES, VALLEYS, CRICKETS, AROUND PENETRATIONS , AND RAKE EDGES. AT DOWNSLOPE ROOF PERIMETERS IT IS RECOMMENDED TO EXTEND THE ICE DAM PROTECTION MEMBRANE 24" MIN. UPSLOPE FROM EXTERIOR WALL. 2. RECOMMENDED MINIMUM SLOPE FOR INSTALLATION OF ASPHALT SHINGLES IS 4:12, IF ONLY ONE LAYER OF NO.15 ASPHALT SATURATED FELT OR OTHER APPROVED WATER-SHEDDING UNDERLAYMENT, SUCH AS IKO STORMTITE,IS SPECIFIED. FOR ROOF SLOPES LESS THAN 4:12 A MINIMUM OF TWO LAYERS OF UNDERLAYMENT IS TO BE INSTALLED "SHINGLE" FASHION WITH A 17"EXPOSURE AND 19" SIDELAP. SHINGLES NOT RECOMMENDED FOR SLOPES LESS THAN 2:12. 24" (See Note 2.) SLOPE ICE & WATER SHIELD EXTENDED 24" PAST INSIDE FACE OF EXTERIOR WALL ROOFING NAILS FASTENED AT APPROXIMATELY 6" TO 10" ON CENTER (O.C.) PERIMETER RAKE DRIP-EDGE FLASHING METAL (INSTALL OVER UNDERLAYMENT AT RAKE.) DOWNSLOPE PERIMETER EAVE DRIP-EDGE FLASHING METAL (INSTALL UNDERNEATH UNDERLAYMENT AT EAVE. TRIM AND BEND IN END AT CORNER TO FORM CLOSED.) FORMED DRIP-EDGE FASCIA BOARD NOTES: 1. A SELF-ADHERING ICE & WATER MEMBRANE TO BE INSTALLED AT ALL POTENTIAL ICE DAMMING LOCATIONS SUCH AS DOWNSLOPE EAVES, VALLEYS, CRICKETS, AROUND PENETRATIONS, AND RAKE EDGES. AT DOWNSLOPE ROOF PERIMETERS IT IS RECOMMENDED TO EXTEND THE ICE DAM PROTECTION MEMBRANE 24" MIN. UPSLOPE FORM EXTERIOR WALL. 2. THE PERIMETER OF THE ROOF DECK SHOULD PROVIDE A CONTINUOUS SOLID WOOD NAILING SURFACE OVER WHICH TO APPLY THE SHEET METAL DRIP-EDGE FLASHING. 3. THE VERTICAL-FACE FLANGE OF SHEET METAL DRIP-EDGE FLASHING SHOULD BE OF SUFFICIENT LENGTH TO PERMIT WATER TO DRIP OFF THE ROOF WITHOUT AFFECTING THE UNDERLYING CONSTRUCTION DURING TIMES OF NO WIND. 4. THE HORIZONTAL FLANGE (I.E., ROOF SIDE) OF SHEET METAL DRIP-EDGE FLASHING SHOULD EXTENDED APPROXIMATELY 2" TO 3" MINIMUM ONTO THE ROOF. 5. IN COLD CLIMATES, CONSIDER INSTALLATION OF AN ISOLATOR SHEET (E.G., A STRIP OF ASPHALT-SATURATED FELT) BETWEEN THE WOOD ROOF DECK AND SHEET METAL FLASHING FLANGE(S) TO MINIMIZE POTENTIAL FOR CONDENSATION AND RESULTING DECAY. EXAMPLE: METAL FLASHING WITH STORM COLLAR EXAMPLE: PRE-FABRICATED FLASHING COLLAR ALTERNATE: SEPARATE SOFT METAL FLASHING CAP,INTO PIPE APPROX 1" ALTERNATE: SEPARATE SOFT METAL FLASHING CAP, FASTEN THROUGH UPSLOPE FLANGE (I.E., BLIND-NAIL.) TO SECURE VENT FLASHING DRAWBBAND COMPATIBLE SEALANT STOR COOLER METAL PIPE FLASHING SOIL STACK PIPE (PLUMBING VENT.) LEAD OR OTHER SOFT METAL PIPE FLASHING (TURN DOWN INTO SOIL STACK APPROXIMATELY 1".) NOTES: 1. SOIL PIPE STACKS SHOULD EXTEND A MINIMUM OF 8" ABOVE ROOF SURFACE. 2. IF EXPOSED FASTENERS ARE PLACED THROUGH VENT'S DOWNSLOPE FLANGE, THEY SHOULD BE WEATHERTIGHT, GASKETED FASTENERS (E.G., RING-SHANK NAILS OR SCREWS). 3. IT MAY BE THAT THE LAYOUT OF THE SOIL PIPE PENETRATION OCCURS IN SUCH A WAY THAT AN ASPHALT SHINGLE BUTT-END JOINT, OR SHINGLE TAB CUTOUT, ALIGNS WITH THE EDGE AND/OR BACK OF THE METAL FLASHING'S FLANGE. IN THIS CASE, INSTALL A PRESSURE-SENSITIVE SELF-ADHERED MODIFIED-ASPHALT MEMBRANE TO STRIP-IN THE SIDES AND BACK OF THE METAL FLASHING FLANGE TO EFFECTIVELY EXTEND THESE FLANGES. CLADDING (FIBER-CEMENT LAP CLADDING SHOWN. LAP 2" MINIMUM OVER STEP FLASHING AND MAINTAIN ABOVE ROOF SURFACE. SEE METAL COUNTERFLASHING DETAIL) WALL CLADDING UNDERLAYMENT(LAP OVER STEP FLASHING AND UP-TURNED ROOF UNDERLAYMENT.) EXTENSION OF ICE & WATER SHIELD (TURNED UP AT WALL.) APRON FLASHING VERTICAL FLANGES (APPROXIMATELY 4", AND SAME UPSLOPE.) APRON FLASHING DOWNSLOPE FLANGE (APPROXIMATELY 5".(FABRICATE WITH HEMMED EXPOSED/LEADING EDGES.)) STEP FLASHING (EXTEND BOTTOM PIECE PAST CORNER. (OPTIONAL: INJECT SEALANT INTO CORNER.) APRON FLASHING SIDE FLANGE(4" MINIMUM EXTENSION PAST CORNER.) METAL STEP FLASHING APRON FLASHING SHOP FORM FLASHING WITH SOLDERED CORNERS HEMMED EDGES NOTES: 1. SHEET METAL STEP AND APRON FLASHINGS ARE SUGGESTED TO BE A MINIMUM OF 26-GAUGE PRE-FINISHED/PAINTED GALVANIZED STEEL 16 OZ. COPPER, .032-INCH THICK PRE-FINISHED ALUMINUM, OR AN EQUIVALENT LONGEVITY NON-CORROSIVE METAL. 2. VERTICAL FLANGE OF STEP FLASHING SHOULD BE LAPPED A MINIMUM OF 2". SHEET METAL COUNTERFLASHING MAY BE OPTIONAL WHERE WALL CLADDING OR SIDING OVERLAPS STEP FLASHING. 3. EXTEND ROOFING UNDERLAYMENT VERTICALLY UP THE WALL SO THAT IT IS OVERLAPPED BY THE WALL CLADDING UNDERLAYMENT. GENERAL ROOFING PLAN NOTES 1. ALL SHEET METAL TO BE INSTALLED IN ACCORDANCE WITH SMACNA STANDARDS. REF. SHADED AREA ON ROOF PLAN. PROVIDE ICE & WATER SHIELD MEMBRANE UNDERLAYMENT AT: 2. 1. EAVES - FROM EDGE OF GUTTER OVERHANG AND EXTEND UP ON TO ROOF 24" PAST INSIDE FACE OF INTERIOR WALL. 2. ROOF VALLEYS-PROVIDE FOR FULL MATERIAL WIDTH OF MEMBRANE (36" WIDE) CENTER ON VALLEY FOR ENTIRE LENGTH. 3. ROOF RIDGES - ON BOTH SIDES OF RIDGE VENT AT ROOF RIDGES. 4. DORMERS & SIDEWALLS - ON ROOF AT SIDE & DORMER WALLS. TURNED AND EXTENDED UP WALL. 5. RAKE, EDGES - ALONG THE RAKE EDGE EXTENDED UP ONTO ROOF 24" PAST INSIDE FACE OF INTERIOR WALL. 6. ALONG EVERY WALL CHIMNEY, & ROOF PENETRATION WHERE FLASHING WILL BE INSTALLED KEYED ROOF PLAN NOTES 1. ICE & WATER SHIELD. 2. ASPHALT SHINGLE. 3. MTL DRIP EDGE AT ROOF EDGE. SEE DIAGRAM 5 / A300. 4. MTL DRIP EDGE WITH K-STYLE GUTTER AT ROOF EDGE. SEE DIAGRAM 9 / A300. 5. RIDGE VENT. SEE DETAIL 7 / A300. 7. PIPE STACK. REF PLUMB FOR SIZE AND LOCATION. SEE DETAIL. 3 / A300 AND DIAGRAM. 8. SEE DIAGRAM 8 / A300 FOR APRON AND STEP FLASHING AT SIDEWALL AND DORMERS. 10. FIREPLACE FLUE. REF BUILDING SECTION ON A500 FOR REQ'D HEIGHT. REF MANUFACTURER'S INSTALLATION INSTRUCTIONS. X 10" / 12" 10" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 12" / 12" 7" / 12" 7" / 12" 7" / 12" 5" / 12" 5" / 12" 5" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 7" / 12" 12" OVERHANG @ 10'-0" 12" OVERHANG RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE RIDGE VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY VALLEY 6" RAKE FACIA @ 9'-0" FACIA @ 9'-0" FACIA @ 10'-0" RAKE RAKE RAKE RAKE RAKE RAKE 3" / 12" 3" / 12" 3" / 12" 7" / 12" 44 3 5 5 4 4 3 4 1 22 3 5 1 22 8 3 4 555 4 11 3 33 33 33 8 8 8 22 5 5 5 5 3 8 4 1 1 4 4 3 RIDGE 1 4 3 3 4 1 1 10 BSA LifeStructures 9365 Counselors Row Suite 300 Indianapolis, IN 46240-1478 ph 317.819.7878 fx 317.819.7288 www.bsalifestructures.com DESIGNED DRAWN APPROVED BSALS PROJECT NO. KEYPLAN PLAN NORTH DATE C:\Users\BChapman\21730002-ARCH_BSALS_CENTRAL_v2018_REVISED PLAN_BChapman.rvt 09/18/20 1:48:20 PM 21730002 Approver Author Designer A300 ROOF PLAN 10-BED MEMORY CARE HOME STORY COTTAGE 18 SEPT 2020 CLIENT PROJECT NO. - 21730002 1 1/2" = 1'-0" 10 EAVE DETAIL 1 1/2" = 1'-0" 7 RIDGE VENT 1 1/2" = 1'-0" 6 GUTTER SIZING DETAIL 1 1/2" = 1'-0" 9 DRIP-EDGE METAL & GUTTER 1/2" = 1'-0" 4 CRICKET VALLEYS@CHIMNEYS 3/16" = 1'-0" 2 ICE DAM @ VALLEY & EAVE 1 1/2" = 1'-0" 5 DRIP-EDGE METAL 1 1/2" = 1'-0" 3 SOIL PIPESTACK 1 1/2" = 1'-0" 8 APRON & STEP FLASHING 1/8" = 1'-0" 1 ROOF PLAN MARK DATE DESCRIPTION 05/27/21