HomeMy WebLinkAboutE001.1Vent Hood
+10' -0"
+8' -6"
+10' -0"
+10' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
OUTLINE OF TABLE BELOW, CENTERED
WITH LIGHTING.
LOCATION OF LIGHT FIXTURE ROUGH-IN,
FIXTURE TO BE A PENDANT/CHANDELIER
11' - 3 1/2"
SALON
BEDROOM 2
BATHROOM
1
BEDROOM 3
BEDROOM 4
LIBRARY
BEDROOM 5
BEDROOM 6
BEDROOM 7
(TYPICAL)
BEDROOM 1
POWDER
BATH 1
PANTRY
KITCHEN
POWDER
BATH 2
LAUNDRY
BATHROOM
2
BEDROOM 9
SUN ROOM
DINING
ENTRY
CLOSET
GALLERY
HALL
STAIRS
READING
ROOM
BEDROOM 8
BEDROOM
10
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+9' -0"
+10' -0"
D
D
D
D
D D
D
+9' -0"
D
D
D
D D
D
D
PENDANT/
CHANDELIER
HEAT LAMP
H
HEAT LAMP
H
8' - 5 1/2" 8' - 4 3/4"
1' - 6 1/4" 1' - 3" 1' - 6" 1' - 6" 1' - 6" 1' - 6" 1' - 6" 1' - 3" 1' - 5 3/8"
6' - 0" 6' - 0"
EQ. 5' - 0" EQ.
6' - 0" 6' - 0" 6' - 0"
EQ. 6' - 0" 6' - 0" EQ.
6' - 6" 6' - 6" 1' - 6"
EQ. 5' - 0" 5' - 0" EQ.
9' - 10 1/4"
7' - 6 7/8"
CEILING MOUNTED SECURITY CAMERA
DIRECTED TOWARDS LOCKABLE MINI-FRIDGE
EQ EQ
3' - 3" 3' - 3"
CONTRACTOR TO PROVIDE BLOCKING
FOR LIGHT FIXTURE PER
MANUFACTURER'S SUGGESTIONS.
EXHAUST FAN
EXHAUST FAN
EXHAUST FAN
EXHAUST FAN VANITY FIXTURE
VANITY FIXTURE
VANITY FIXTURE
VANITY FIXTURE
D
D D D
NOTE: ALL SYMBOLS ARE SHOWN FOR CLARITY & COORDINATION -SEE
ELECTRICAL DESIGN-BUILD PLANS FOR EXACT LOCATIONS OF ELECTRICAL
EQUIPMENT & FIXTURES.
D
3
M
T
SWITCH
SWITCH-3 WAY
SWITCH DIMMER
SWITCH-MOTION SENSOR
CABLE TV
PHONE / DATA
FLOOR PHONE / DATA
LOCKABLE THERMOSTAT
SD
WP
GFI
DUPLEX OUTLET
(TYP. @ 1'-6" A.F.F)
DUPLEX OUTLET-GFI
DUPLEX OUTLET- WEATHERPROOF
QUADPLEX OUTLET
FLOOR DUPLEX OUTLET
SMOKE DETECTOR
'#' SHOWN NEXT TO A SYMBOL INDICATES THAT THE FIXTURE'S HEIGHT A.F.F.
(ALL HEIGHTS ARE CENTERLINE OF FIXTURE)
ELECTRICAL LEGEND/NOTES
GENERAL ELECTRICAL PLAN NOTES
MAGNETIC LOCKS ON DOORS SHALL BE TIED TO EMERGENCY GENERATOR POWER
GENERATOR TO BE 22Kw GENERAC GUARDIAN
ALL CAN LIGHTS SHALL BE ON DIMMER SWITCHES UNLESS NOTED OTHERWISE
ALL FIXTURES PLACED ABOVE OR IN SHOWER OR TUB ENCLOSURES SHALL BE
RATED FOR WET USE
1
2
3
4
5 FINAL CAMERA COUNT AND LOCATIONS TO BE COORDINATED WITH OWNER
6 DIMMER SWITCH COUNT AND LOCATIONS TO BE COORDINATE WITH OWNER
BSA LifeStructures
9365 Counselors Row Suite 300
Indianapolis, IN 46240-1478
ph 317.819.7878 fx 317.819.7288
www.bsalifestructures.com
DESIGNED
DRAWN
APPROVED
BSALS PROJECT NO.
KEYPLAN
PLAN NORTH
DATE
C:\Users\BChapman\21730002-ARCH_BSALS_CENTRAL_v2018_REVISED PLAN_BChapman.rvt
09/18/20 1:48:32 PM
21730002
Approver
Author
Designer
E131
REFLECTED CEILING
ELECTRICAL PLAN
10-BED MEMORY CARE
HOME
STORY
COTTAGE
02 SEPTEMBER 2020
CLIENT PROJECT NO. - 21730002
MARK DATE DESCRIPTION
1/4" = 1'-0"
1
REFLECTED CEILING ELECTRICAL PLAN
05/27/21