Loading...
HomeMy WebLinkAboutA-002 - INTERIOR PARTITION TYPES AND STANDARD PARTITION DETAILSPARTITION TYPE SYMBOL PARTITION TYPE FIRE RATING (I.E. 1= 1 HOUR) PARTITION HEIGHT CODE NEW PARTITIONS EXISTING PARTITIONS TO REMAIN PARTITIONS TO BE DEMOLISHED M8A.D.2.A S2A.P ADDITIONAL PARTITION DESIGNATION, WHERE OCCURS PARTITION DESIGNATION ACOUSTICAL ATTENUATION REQ'D HEIGHT AS INDICATED IN INCHES OR (V) INDICATES HEIGHT THAT VARIES (C) TERMINATE AT CEILING (P) TERMINATE 6" ABOVE CEILING (D) TERMINATE AT FLOOR / ROOF DECK 6" * FIRE RATING AND ACOUSTICAL ATTENUATION WHEN REQUIRED BY PARTITION SYMBOL 4 3/4" W4A 2x4 WOOD STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE * ACOUSTIC ATTEN. COMPONENTS STC-44 W4K-1 a| |a 4 1/2" W4K 2x4 WOOD STUDS WITH (1) LAYER 1/2" GYPSUM WALL BOARD EACH SIDE 6 3/4" W6A 2x6 WOOD STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE 6 3/4" W6A 2x6 WOOD STUDS WITH (1) LAYER 5/8" GYPSUM WALL BOARD EACH SIDE * ACOUSTIC ATTEN. COMPONENTS STC-44 4'-0" FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET, FIREHOSE CABINET, HOSE VALVE CABINET, OR ANY COMBINATION OF THE ABOVE 6" ELECTRICAL, SWITCHES OR RECEPTACLES OVER COUNTERS OR SIMILAR WORK SURFACES 2" 2" 1'-3" ELECTRICAL OR RECEPTACLE TRIM PLATES DOOR FRAME OR WINDOW FRAME 4'-0" 6" 6'-8" WALL END OR EDGE (WHERE OCCURS) FIRE ALARM NOTE: ENTIRE LENS TO BE NOT LESS THAN 80" AND NOT GREATER THAN 96" AFF THERMOSTAT OR TEMPERATURE CONTROL TELEPHONES, DOOR SWITCHES, DOOR CONTROLLERS, FIRE ALARM PULL SWITCHES AND SIMILAR ITEMS (THE INTENT IS TO ALIGN TOPS OF ALL OPERABLE ITEMS WHILE ALLOWING THE OPERABLE PARTS TO BE LESS THAN 4'-0" AFF) ELECTRICAL RECEPTACLES - SINGLE, GANGED, OR SEPARATED BY 2" WINDOW, DOOR OR "FEATURE" THAT SEPARATES WALL INTO SEGMENTS EQ EQ WALL END OR EDGE (WHERE OCCURS) WALL SEGMENT 24" WIDE OR LESS 2" NOTES: 1. USE THIS DETAIL TO LOCATE DEVICES THAT ARE INDICATED ON THE DRAWINGS BUT NOT LOCATED BY DIMENSION, OR TO LOCATE REQUIRED DEVICES THAT ARE NOT INDICATED ON THE DRAWINGS. 2. ALIGN MULTIPLE DEVICES HORIZONTALLY AND/OR VERTICALLY AS DETAILED. 3. ITEMS OTHER THAN ELECTRICAL RECEPTACLES SHALL BE MOUNTED NEAR DOORWAYS OR INTERSECTING WALLS AS DETAILED SO AS NOT TO INTERFERE WITH THE PLACEMENT OF ART OR FUNITURE - EXCEPT THAT WHERE THE WALL SEGMENT IS LESS THAN 24" WIDE, CENTER THE DEVICES AS DETAILED. ELECTRICAL RECEPTACLES - SINGLE, GANGED, OR SEPARATED BY 2" COLUMN OR PILASTER FIRE ALARM NOTE: ENTIRE LENS TO BE NOT LESS THAN 80" AND NOT GREATER THAN 96" AFF EQ. EQ TELEPHONES, DOOR SWITCHES, DOOR CONTROLLERS, FIRE ALARM PULL SWITCHES AND SIMILAR ITEMS 2" A. PARTITION SYMBOLS APPEAR ON THE FLOOR PLANS. B. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM BOARD IN ALL ROOMS CONTAINING OPERABLE PLUMBING FIXTURES UNLESS NOTED OTHERWISE. C. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD, PENETRATIONS AND ADDITIONAL SPECIFIED SOUND ATTENUATION COMPONENTS AT SOUND RATED WALLS. D. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS INDICATED TO HAVE CERAMIC TILE. E. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM BUILDING STRUCTURE TO PREVENT TRANSFER OF VERTICAL LOADS WHILE PROVIDING LATERAL SUPPORT AS SPECIFIED. F. WOOD OR METAL STUD SPACING SHALL BE 16” ON CENTER MAXIMUM UNLESS OTHERWISE REQUIRED BY DELEGATED DESIGN OR NOTED OTHERWISE. SHEET TITLE SHEET NUMBER Ascent Hospitality 1305 Mall of Georgia Blvd. Buford, Georgia 30519 770-904-0765 Owner RATIO 101 South Pennsylvania Street Indianapolis, Indiana 46204 317-633-4040 Architect CE Solutions, Inc. Structural Engineer 10 Shoshone Drive Carmel, Indiana 46032 317-818-1912 KEY PLAN A B PROJECT NO. SHEET ISSUE SEAL | DATE COPYRIGHT NOTICE: THIS ARCHITECTURAL AND ENGINEERING DRAWING IS GIVEN IN CONFIDENCE AND SHALL BE USED ONLY PURSUANT TO THE AGREEMENT WITH RATIO. NO OTHER USE, DISSEMINATION OR DUPLICATION MAY BE MADE WITHOUT PRIOR WRITTEN CONSENT OF RATIO. ALL COMMON LAW RIGHTS OF COPYRIGHT AND OTHERWISE ARE HEREBY SPECIFICALLY RESERVED. 5/10/2021 4:24:21 PM A-002 INTERIOR PARTITION TYPES AND STANDARD PARTITION DETAILS 21009.000 ASHERWOOD ESTATE KITCHEN REMODEL Carmel, IN INTERIOR PARTITION LEGEND INTERIOR PARTITION HEIGHT CODES INTERIOR PARTITION TYPES STANDARD-DEVICE MOUNTING GUIDELINES INTERIOR PARTITION NOTES 1 PERMIT SET 05/10/21 05/10/21 05/27/21