HomeMy WebLinkAboutA-002 - INTERIOR PARTITION TYPES AND STANDARD PARTITION DETAILSPARTITION TYPE SYMBOL
PARTITION TYPE
FIRE RATING (I.E. 1= 1 HOUR)
PARTITION HEIGHT CODE
NEW PARTITIONS
EXISTING PARTITIONS TO REMAIN
PARTITIONS TO BE DEMOLISHED
M8A.D.2.A
S2A.P
ADDITIONAL PARTITION
DESIGNATION, WHERE
OCCURS
PARTITION DESIGNATION
ACOUSTICAL ATTENUATION
REQ'D
HEIGHT AS
INDICATED IN
INCHES OR (V)
INDICATES
HEIGHT THAT
VARIES
(C) TERMINATE AT CEILING
(P) TERMINATE 6" ABOVE CEILING
(D) TERMINATE AT FLOOR / ROOF DECK
6"
* FIRE RATING AND ACOUSTICAL ATTENUATION
WHEN REQUIRED BY PARTITION SYMBOL
4 3/4"
W4A 2x4 WOOD STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE
* ACOUSTIC ATTEN. COMPONENTS STC-44
W4K-1
a| |a
4 1/2"
W4K 2x4 WOOD STUDS WITH (1) LAYER 1/2"
GYPSUM WALL BOARD EACH SIDE
6 3/4"
W6A 2x6 WOOD STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE
6 3/4"
W6A 2x6 WOOD STUDS WITH (1) LAYER 5/8"
GYPSUM WALL BOARD EACH SIDE
* ACOUSTIC ATTEN. COMPONENTS STC-44
4'-0"
FIRE EXTINGUISHER
FIRE EXTINGUISHER
CABINET, FIREHOSE
CABINET, HOSE VALVE
CABINET, OR ANY
COMBINATION OF THE
ABOVE
6"
ELECTRICAL, SWITCHES
OR RECEPTACLES OVER
COUNTERS OR SIMILAR
WORK SURFACES
2"
2"
1'-3"
ELECTRICAL OR
RECEPTACLE TRIM
PLATES
DOOR FRAME OR
WINDOW FRAME
4'-0"
6"
6'-8"
WALL END OR EDGE
(WHERE OCCURS)
FIRE ALARM NOTE:
ENTIRE LENS TO BE NOT LESS THAN 80" AND
NOT GREATER THAN 96" AFF
THERMOSTAT OR
TEMPERATURE CONTROL
TELEPHONES, DOOR SWITCHES,
DOOR CONTROLLERS, FIRE ALARM
PULL SWITCHES AND SIMILAR ITEMS
(THE INTENT IS TO ALIGN TOPS OF
ALL OPERABLE ITEMS WHILE
ALLOWING THE OPERABLE PARTS
TO BE LESS THAN 4'-0" AFF)
ELECTRICAL RECEPTACLES - SINGLE,
GANGED, OR SEPARATED BY 2"
WINDOW, DOOR OR
"FEATURE" THAT
SEPARATES WALL
INTO SEGMENTS
EQ EQ
WALL END OR EDGE
(WHERE OCCURS)
WALL SEGMENT 24" WIDE OR LESS
2"
NOTES:
1. USE THIS DETAIL TO LOCATE
DEVICES THAT ARE INDICATED ON
THE DRAWINGS BUT NOT
LOCATED BY DIMENSION, OR TO
LOCATE REQUIRED DEVICES THAT
ARE NOT INDICATED ON THE
DRAWINGS.
2. ALIGN MULTIPLE DEVICES
HORIZONTALLY AND/OR
VERTICALLY AS DETAILED.
3. ITEMS OTHER THAN ELECTRICAL
RECEPTACLES SHALL BE
MOUNTED NEAR DOORWAYS OR
INTERSECTING WALLS AS
DETAILED SO AS NOT TO
INTERFERE WITH THE PLACEMENT
OF ART OR FUNITURE - EXCEPT
THAT WHERE THE WALL SEGMENT
IS LESS THAN 24" WIDE, CENTER
THE DEVICES AS DETAILED.
ELECTRICAL RECEPTACLES -
SINGLE, GANGED, OR
SEPARATED BY 2"
COLUMN
OR
PILASTER
FIRE ALARM NOTE:
ENTIRE LENS TO BE NOT
LESS THAN 80" AND NOT
GREATER THAN 96" AFF
EQ. EQ
TELEPHONES, DOOR
SWITCHES, DOOR
CONTROLLERS, FIRE
ALARM PULL
SWITCHES AND
SIMILAR ITEMS
2"
A. PARTITION SYMBOLS APPEAR ON THE FLOOR PLANS.
B. PROVIDE MOLD AND MOISTURE RESISTANT GYPSUM
BOARD IN ALL ROOMS CONTAINING OPERABLE PLUMBING
FIXTURES UNLESS NOTED OTHERWISE.
C. PROVIDE ACOUSTICAL SEALANT AT WALL SILL, HEAD,
PENETRATIONS AND ADDITIONAL SPECIFIED SOUND
ATTENUATION COMPONENTS AT SOUND RATED WALLS.
D. PROVIDE SPECIFIED TILE BACKER BOARD AT ALL WALLS
INDICATED TO HAVE CERAMIC TILE.
E. ISOLATE NON-LOAD-BEARING STUD FRAMING FROM
BUILDING STRUCTURE TO PREVENT TRANSFER OF
VERTICAL LOADS WHILE PROVIDING LATERAL SUPPORT AS
SPECIFIED.
F. WOOD OR METAL STUD SPACING SHALL BE 16” ON CENTER
MAXIMUM UNLESS OTHERWISE REQUIRED BY DELEGATED
DESIGN OR NOTED OTHERWISE.
SHEET TITLE
SHEET NUMBER
Ascent Hospitality
1305 Mall of Georgia Blvd.
Buford, Georgia 30519
770-904-0765
Owner
RATIO
101 South Pennsylvania Street
Indianapolis, Indiana 46204
317-633-4040
Architect
CE Solutions, Inc.
Structural Engineer
10 Shoshone Drive
Carmel, Indiana 46032
317-818-1912
KEY PLAN
A
B
PROJECT NO.
SHEET ISSUE
SEAL | DATE
COPYRIGHT NOTICE: THIS ARCHITECTURAL
AND ENGINEERING DRAWING IS GIVEN IN
CONFIDENCE AND SHALL BE USED ONLY
PURSUANT TO THE AGREEMENT WITH RATIO.
NO OTHER USE, DISSEMINATION OR
DUPLICATION MAY BE MADE WITHOUT PRIOR
WRITTEN CONSENT OF RATIO. ALL COMMON
LAW RIGHTS OF COPYRIGHT AND OTHERWISE
ARE HEREBY SPECIFICALLY RESERVED.
5/10/2021 4:24:21 PM
A-002
INTERIOR PARTITION
TYPES AND
STANDARD
PARTITION DETAILS
21009.000
ASHERWOOD
ESTATE
KITCHEN
REMODEL
Carmel, IN
INTERIOR PARTITION LEGEND
INTERIOR PARTITION HEIGHT CODES
INTERIOR PARTITION TYPES
STANDARD-DEVICE MOUNTING GUIDELINES
INTERIOR PARTITION NOTES