HomeMy WebLinkAboutM001.0REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILING CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
SA
R R
R R
R4
GFCI
R R
R4
R
R4
R4
R4
D
M
D
M
D
M
D
M
D
M
R4
D
M
D
M
D
M
SD
EXERCISE ROOM
WINDOW WELL
MASSAGE ROOM
P1
H1
E1
H3
H2
E2
E3
E4
E5
E6
P3
P4
P2
P5
H4
ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1
PROVIDE ROUGH IN AND INSTALL FOR (2) NEW WALL
SCONCES SWITCHED TOGETHER ON A DIMMER.
PROVIDE ROUGH IN AND INSTALL FOR (1) NEW GFI
CIRCUIT NEXT TO VANITY.
PROVIDE ROUGH IN AND INSTALL FOR (2) NEW 2"
GIMBALL CANS SWITCHED TOGETHER ON A DIMMER.
1
PROVIDE ROUGH IN AND INSTALL FOR (3) NEW BAR
BULB PENDANTS TO BE SWITCHED TOGETHER ON A
DIMMER.
1
PROVIDE ROUGH IN AND INSTALL FOR (6) NEW
RECESSED CAN LIGHTS. (4) OUTSIDE CANS TO BE
GIMBALL CANS, (2) MIDDLE CANS TO BE STANDARD 2"
CANS. ALL (6) TO BE SWITCHED TOGETHER ON A
DIMMER SWITCH.
1
PROVIDE ROUGH IN AND INSTALL FOR (2) NEW 2" CAN
LIGHTS SWITCHED TOGETHER ON A DIMMER.
PROVIDE ROUGH IN AND INSTALL FOR (1) NEW
EXHAUST FAN ON ITS OWN SWITCH.
1
PROVIDE ROUGH IN AND INSTALL FOR (1) NEW
KEYLESS BULB FIXTURE AND SWITCH INSIDE
MECHANICAL CLOSET.
1
PROVIDE ROUGH IN AND INSTALL FOR (1) NEW 2"
GIMBAL RECESSED CAN LIGHT ON ITS OWN DIMMER
SWITCH.
PROVIDE ROUGH IN AND INSTALL FOR (2) NEW 2"
GIMBAL RECESSED CAN LIGHTS SWITCHED
TOGETHER ON A DIMMER.
PROVIDE ROUGH IN AND INSTALL FOR (1) NEW
CHANDELIER AS SHOWN ON PLAN SWITCHED ON A
DIMMER.
E1
E2
E3
E4
E5
E6
E1
E2
E3
E4
E5
E6
HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1
ROUGH IN AND INSTALL VENTILATION FOR TWO
EXHAUST VENTS TO EXISTING VENT STUB OUT.
1
ROUGH IN AND INSTALL PROPER SUPPLY AND RETURN
VENTILATION FOR THIS ROOM.
1
REROUTE EXISTING DUCTS IN THIS SPACE TO BE HIGH
AND TIGHT TO CEILING JOISTS TO AVOID CEILINGS.
1
ROUGH IN AND INSTALL THRU-WALL VENTED
DEHUMIDIFIER FOR WINE ROOM.
H1
H2
H3
H4
H1
H2
H3
H4
PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1
PROVIDE ROUGH IN AND INSTALL FOR TOILET AS
SHOWN ON PLAN.
1
PROVIDE ROUGH IN AND INSTALL FOR VANITY AND
SINK IN WALL.
1
PROVIDE ROUGH IN AND INSTALL FOR (2) SHOWER
HEADS, (2) SHOWER VALVES, AND (2) 24" LINEAR STRIP
DRAINS ON EACH SIDE OF SHOWER ROOM AS SHOWN
ON PLAN.
PROVIDE ROUGH IN AND INSTALL FOR FREESTANDING
TUB AND TUB FILLER.
PROVIDE ROUGH IN AND INSTALL FOR STEAM
SHOWER COMPONENTS.
1
PROVIDE ROUGH IN AND INSTALL FOR STEAM
SHOWER GENERATORS IN THIS ROOM.
1
PROVIDE ROUGH IN AND INSTALL FOR NEW WATER
BOTTLE FILLING STATION RECESSED INTO WALL.
CONNECT TO SINK BEHIND THIS WALL.
P1
P2
P3
P4
P5
P1
P2
P3
P4
P5
LEGRAND
SCREWLESS
COVER PLATE -
WHITE
LEGRAND -
SCREWLESS
PADDLE SWITCH
- WHITE
DECORA
PADDLE DIMMER
SWITCH - WHITE
N
BURNETT RESIDENCE
Basement Spa
1311 Regal Dr.
Carmel, IN 46032
Revision: Date:
4
SHEET OF 10
SIGNATURE / SEAL
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.
CUSTOM LIVING
5335 Winthrop Ave
Indianapolis IN 46220
5/21/21
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
DESIGNER: PETER MEEHAN
E: peter@customlivingusa.com
C: 847.702.2917
PROPOSED M.E.P. PLAN
SCALE: 1/2" = 1'
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE
RECESSED CAN LIGHTS
DECORATIVE LIGHT FIXTURES
2" 3000K
MODEL NO.
NM2-2RG M2
Round LED
Recessed
Adjustable
Gimbal
(3) Pendants
for Green Wall
(2) Wall
Sconces
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new equipment
and ductwork being supplied, fabricated and installed for
the project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect on
the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing, electrical
or ductwork is found in walls being deleted that is not
included on the plans there will be a Change Order
during construction to relocate as necessary.
Owners understand that during mechanical rough-ins
there will be times when the water service will be shut off
to areas in the home.
Plumbing and Lighting fixtures supplied by Owner will not
be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must
be selected and on-site prior to start of mechanical
rough-ins.
05/28/21