HomeMy WebLinkAboutS101.0EXISTING 2X4 FRAMING
DEMOLITION & FRAMING KEY
NO DEMO IN THIS ROOM
EXISTING 2X6 FRAMING
WALL SECTION TO BE REMOVED
NEW 2x4 FRAMING
NEW 2X6 FRAMING
BULK HEAD / LOWERED CEILING
B7220
SB36
SB3021
SB24L B40
B18R 3DB36
B48
INDUCTION
COOKTOP
3DB36B18L
SB2721 3DB1521 SB2721
B18
DBL
TRASH
3DB1521
24DW
B39
B405
3DB1521
B30
SINGLE
OVEN
B405
B3612 B3612 B3612
B7220
SB36
SB3021
SB24L B40
B18R 3DB36
B48
INDUCTION
COOKTOP
3DB36 B18L
SB2721 3DB1521 SB2721
B18
DBL
TRASH
3DB1521
24DW
B39
B405
3DB1521
B30
SINGLE
OVEN
B405
B3612 B3612 B3612
U301290
U272487
U332685
SINGLE OVEN
& MICRO
U282187L
U182487L
W1833L
W483021
HOOD
W3633W1833R W3633
W3933
D06
D01
D03
D03
D02
D04
D04
2668
D02
cL
cL
cL
c cL
L
cL
R
R
3
R
R
R
R R
R
R
WP
WP
3
R
R R
R R
R R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
3 3
R R R
3
R
3
3
R
T
3
R
R
R
3
R
R
R
GFCI GFCI
R
GFCI
3
3 3
CT
H
DW
A
O
CO/SD
CO/SD
M
O
GFCI
CW CD
6'
1'-6"
4'-7 3/4"
281"
54" 39 1/2"
41"
26 1/2"
3'
3'-4 1/2"
10'-10"
6'-1"
4'-1"
1'-3"
3'
2'-1" 6'-1" 5'-6 1/2"
10'-3 1/2" 5'-5"
2'-2"
1'-8 1/2"
5'-7 3/4" 5'-7 3/4"
2'-9 7/8" 2'-9 7/8" 2'-9 7/8" 2'-9 7/8"
4'-8"
6'-7 1/2"
3'-11 3/4"
9'
117"
6'-9 11/16"
8'-6 1/2"
7'-8 5/16"
F1
GARAGE
PORCH
F2
F3
F1
F4
F5 F1
F6
F7
I3
D4
D4
D4
D4
D4
D4
D3
D3
D3
D3
D3
CC1
CC1
CC1
BEDROOM 1
BEDROOM 2
BEDROOM 3
FAMILY ROOM
LIVING ROOM
KITCHEN
HALLWAY
LAUNDRY
MUDROOM
POWDER
BATH
HALL BATH
HALL
Gas Direct
Vent Fireplace
F1
U42243
R
N
FRAMING PLAN NOTES
NOTE QTY DESCRIPTION
4
FRAME ALL NEW NON LOAD BEARING INTERIOR WALLS AS
SHOWN
1
FRAME NEW HALF WALL AND SHOWER BENCH AS SHOWN.
FRAME NEW NICHE OPENING AS SHOWN ON TILE DETAIL
DRAWINGS.
1 FRAME NEW ISLAND HALF WALL AS SHOWN
1
INSTALL NEW HEADER FOR SINGLE CASED OPENING IN
EXISTING LOCATION OF DOUBLE FRENCH DOORS
1
FRAME ALL NEW DOORWAYS AS SHOWN ACCORDING TO
DOOR SCHEDULE
1
FRAME NEW WALLS FOR RECESSED NOOK. INSTALL
BLOCKING FOR FLOATING SHELVES IN LOCATIONS SHOWN
ON INTERIOR TRIM DETAILS
1 FRAME IN OPENING FROM DELETED OPENING
F1
F2
F3
F4
F5
F6
F7
F1
F2
F3
F4
F5
F6
F7
INSULATION PLAN NOTES
NOTE QTY DESCRIPTION
1
FOAM AND FIRECAULK ALL MECHANICAL PENETRATIONS
PER MUNICIPAL BUILDING CODE REQUIREMENTS.
1
INSTALL NEW WALL AND CEILING INSULATION WHERE
NECESSARY FROM DEMOLITION AND MECHANICAL ROUGH
INS. FINAL INSULATION SCOPE TO BE DETERMINED ON A
FIELD WALK FOLLOWING MECHCANICAL ROUGH IN PHASE.
1
INSTALL NEW EXTERIOR WALL INSULATION IN LOCATION
WHERE WINDOW IS TO BE DELETED
I1
I2
I3
I1
I2
I3
DRYWALL PLAN NOTES
NOTE QTY DESCRIPTION
1
EXISTING DRYWALL FINISH NOTES:
-WALLS: LEVEL 4, SMOOTH
-CEILING: LEVEL4, TEXTURED
1
FINAL DRYWALL SCOPE TO BE DETERMINED ON A FIELD
WALK FOLLOWING MECHANICAL ROUGH IN PHASE.
6
INSTALL AND FINISH NEW DRYWALL ON ALL NEWLY
FRAMED WALLS. MATCH EXISTING WALL FINISH.
6
DRYWALL PATCH CEILINGS WHERE NECESSARY FROM
DEMO/FRAMING AND MECHANICAL ROUGH INS.
D1
D2
D3
D4
D1
D2
D3
D4
CONCTRETE FLATWORK PLAN NOTES
NOTE QTY DESCRIPTION
3
PATCH IN CONCRETE SLAB WHERE NECESSARY FROM
MECHANICAL RELOCATES
CC1
DOOR SCHEDULE
NUMBER FLOOR QTY R/O TOP WIDTH HEIGHT DESCRIPTION SUPPLIER
D01 1 1 26"X82 1/2" 80" 24 " 80 " HINGED-PANEL
D02 1 2 32"X82 1/2" 80" 30 " 80 " HINGED-PANEL
D03 1 2 74"X82 1/2" 80" 36 " 80 " POCKET-PANEL
D04 1 2 62"X82 1/2" 80" 60 " 80 " DOUBLE HINGED-PANEL
D05 1 1 73"X81" 80" 72 " 80 " DOUBLE HINGED-PANEL
D06 1 1 125"X82 1/2" 80" 123 " 80 " DOORWAY
1'-4"
8'
HEADER-
DOUBLE 2X8 (UNLESS
NOTED OTHERWISE)
DOUBLE
TOP PLATE
KING STUD
CRIPPLE STUD
TREATED
BOTTOM PLATE
O.C.
4" CONCRETE
SLAB
2X8 CEILING
JOISTS @ 16" O.C.
LAZZARA RESIDENCE
Interior Remodel
308 Woodland Lane
Carmel, IN 46032
Revision: Date:
A3
SHEET OF 8
SIGNATURE / SEAL
DESIGNER: TOM LAZZAARA
E: tom@customlivingusa.com
C: 317.289.5590
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.
CUSTOM LIVING
5335 Winthrop Ave
Indianapolis IN 46220
5/21/2021
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
GENERAL PROPOSED PLAN NOTES
Framing contractors are responsible for all labor,
for the scope of work specified on the drawings
provided by Custom Living.
Owner understands that Custom Living has only
provided a labor and material allowance for the
scope of Rough Carpentry work specified on the
drawings. Any additional work added or
uncovered during this scope will be filed as a
Change Order during construction
Owner understands that the drywall allowance is
based on an estimated board count and square
footage take-off. A final walk through with a
drywall contractor after framing and mechanical
rough-ins will be necessary to finalize drywall
installation and finish budgets.
Final drywall touch-ups will follow countertop
installation.
PROPOSED FLOOR PLAN
SCALE: 3/16" = 1'
TYPICAL FRAMING DETAIL
SCALE: 3/8" = 1' 0"
05/28/21