Loading...
HomeMy WebLinkAboutM101.06" 3000K MODEL NO. 6RLD G3 07LM 30K 90CRI 120 FRPC WWH M6 DUPLEX WHITE TOGGLE SWITCH WHITE REFRIGERATOR OUTLET MICROWAVE OUTLET DISHWASHER POWER SUPPLY HOOD VENT POWER SUPPLY GARBAGE DISPOSAL POWER SUPPLY COOKTOP POWER SUPPLY CLOTHES DRYER OUTLET CLOTHES WASHER OUTLET 110V OUTLET 220/240V OUTLET GFCI OUTLET OUTDOOR OUTLET LOW VOLTAGE TRANSFORMER SINGLE POLE SWITCH DIMMER SWITCH 3-WAY SWITCH 4-WAY SWITCH GD WALL SWITCH GD COUNTERTOP AIR SWITCH LOW VOLTAGE LIGHTING SWITCH TIMER SWITCH OCCUPANCY SWITCH SURFACE MOUNT LIGHT FIXTURE 4" RECESSED CAN LIGHT 6" RECESSED CAN LIGHT 6" RECESSED CAN/FAN UNIT EXHAUST FAN ONLY EXHAUST FAN W/ LIGHT WALL MOUNTED SCONCE / LIGHT CEILING FAN LOW VOLTAGE LIGHT SMOKE DETECTOR CARBON MONOXIDE DETECTOR SMOKE/CARBON MONOXIDE MOTION SENSOR CEILING SPEAKER GAS SHUT-OFF KEY MAIN WATER SHUT-OFF LAUNDRY BOX FROST PROOF HOSE BIB CLEAN OUT TILE-IN DRAIN FLOOR DRAIN COLD AIR RETURN FLOOR FLOOR SUPPLY REGISTER CEILING CEILING SUPPLY REGISTER WALL WALL SUPPLY REGISTER EXTERIOR WALL EXHAUST VENT T THERMOSTAT DRYER BOX ELECTRICAL KEY PLUMBING KEY HVAC KEY cL cL c L cL cL cL cL cL cL R R 3 R R R R R R R WP WP 3 R R R R R R R R R R R R R R R R R R R R R R 3 3 R R R 3 R 3 3 R T 3 R R R 3 R R R GFCI GFCI R GFCI 3 3 3 CT H DW GD A O SD SD SD CO/SD CO/SD M O GFCI CW CD 6' 1'-7 3/4" 1'-7 3/4" 2'-5 1/2" 3'-6" 4'-9 1/2" 2' 2'-4 1/2" 1'-4" 2'-10" 1'-3" 4'-6" 6'-6 1/4" 7'-3 5/16" 5'-8" H1 GARAGE PORCH E3 E4 E5 E6 E7 E8 E9 E9 E10 E11 E10 E12 E13 E11 E14 E11 E15 E16 E17 E17 E18 E20 E6 E19 E21 E11 E22 E23 E25 E26 E7 E7 E7 E11 E27 E28 E29 E30 E31 E32 P2 P3 P4 H2 H2 H3 H4 H5 H6 BEDROOM 1 BEDROOM 2 BEDROOM 3 FAMILY ROOM LIVING ROOM KITCHEN HALLWAY LAUNDRY MUDROOM POWDER BATH HALL BATH HALL P5 R N PROPOSED HVAC PLAN NOTES NOTE QTY DESCRIPTION 1 RELOCATE ROUGH IN AND INSTALL NEW TOE KICK VENT IN VANITY BASE 2 CONNECT NEW BATH FAN TO EXISTING EXTERIOR EXHAUST VENT 1 CONNECT NEW BATH FAN TO EXISTING EXTERIOR EXHAUST VENT LOCATED ABOVE WALL 1 INSTALL NEW EXTERIOR ROOF PENETRATION FOR BATH VENT 1 RELOCATE EXISTING DRYER VENT IN WALL AND CONNECT TO EXISTING EXTERIOR PENETRATION 1 INSTALL NEW DUCT AND EXTERIOR PENETRATION FOR HOOD PER APPLIANCE SPECS H1 H2 H3 H4 H5 H6 H1 H2 H3 H4 H5 H6 PROPOSED ELECTRICAL PLAN NOTES NOTE QTY DESCRIPTION 1 ELECTRICIAN TO VERIFY EXISTING SMOKE AND CO DETECTORS IN HOME MEET CURRENT MUNICIPAL CODE REQUIREMENTS. IF ADDITIONAL WORK IS REQUIRED TO BRING THEM UP TO CODE, THERE WILL BE AN ADDITIONAL COST FOR LABOR AND MATERIALS. 1 ELECTRICIAN TO VERIFY ALL GFCI OUTLETS MEET CURRENT MUNICIPAL CODE REQUIREMENTS. 1 PROVIDE ROUGH IN AND FINISH FOR (6) 6" RECESSED CAN LIGHTS AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR (3) VANITY SCONCE LIGHTS AS SHOWN. FINAL HEIGHTS TO BE DETERMINED ON SITE DURING ROUGH IN. HOMEOWNERS UNDERSTAND THE TYPE OF FIXTURE SELECTED MAY HAVE AN EFFECT ON INSTALLATION COST. 1 PROVIDE ROUGH IN AND FINISH FOR (2) GFCI PROTECTED VANITY OUTLETS. 2 PROVIDE ROUGH IN AND FINISH FOR (2) PANASONIC FAN UNITS AS SHOWN. HVAC CONTRACTOR TO CONNECT FAN TO EXTERIOR VENT. 4 PROVIDE ROUGH IN AND FINISH FOR ALL NEW SWITCHING IN MASTER BATH AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR NEW WALL OUTLET. PROVIDE EXTENSION CORD RUN IN CONDUIT ALONG TOP OF BASEBOARD TO LOCATION OF TABLE LAMP. CUSTOM LIVING TO SUPPLY EXTENSION CORD AND CONDUIT. 2 PROVIDE ROUGH IN AND FINISH FOR EXISTING FIXTURE IN NEW LOCATION. FINAL LOCATION TO BE DETERMINED ON SITE DURING ROUGH IN. 2 PROVIDE ROUGH IN AND FINISH FOR NEW FIXTURE AS SHOWN. TIE FIXTURE INTO EXISTING SWITCHING. 5 PROVIDE ROUGH IN AND FINISH FOR NEW WALL OUTLET 1 DELETE EXISTING LIGHT AND MAKE A SWITCHED WALL OUTLET. LOCATION TO BE DETERMINED ON SITE. 1 PROVIDE ROUGH IN AND FINISH FOR NEW 6" RECESSED CAN FAN. USE EXISTING VENT LINE LOCATED ON WALL ABOVE. 1 PROVIDE ROUGH IN AND FINISH FOR NEW DEDICATED TESLA CHARGING OUTLET. LOCATION TO BE DETERMINED ON SITE. 1 PROVIDE ROUGH IN AND FINISH FOR (7) NEW 6" RECESSED CAN LIGHTS AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR NEW GFCI OUTLET, WASHER OUTLET AND DEDICATED DRYER OUTLET AS SHOWN. PROVIDE ROUGH IN AND FINISH FOR (4) 6" LED RECESSED CANS AS SHOWN. 2 PROVIDE ROUGH IN AND FINISH FOR (1) LED CLOSET LIGHT WITH JAMB ACTIVATED SWITCH AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR ALL NEW SWITCHING AS SHOWN. PROVIDE ROUGH IN AND FINISH FOR (3) 6" RECESSED CANS AS SHOWN. 1 PROVIDE ROUGH IN AND FINISH FOR GFCI PROTECTED OUTLET AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR ALL NEW SWITCHING AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR NEW FLUSH MOUNT DECORATIVE FIXTURE AS SHOWN. HOMEOWNERS UNDERSTAND THE TYPE OF FIXTURE SELECTED MAY HAVE AN EFFECT ON INSTALLATION COST. 1 PROVIDE ROUGH IN AND FINISH FOR (5) NEW WALL OUTLETS 1 PROVIDE ROUGH IN AND FINISH FOR (2) NEW WALL SCONCES AS SHOWN 2 RUN CONDUIT FOR WIRRING AND INSTALL (2) NEW WEATHERPROOF OUTLETS AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR (7) NEW 6" RECESSED CAN FIXTURES AS SHOWN 1 PROVIDE ROUGH IN AND FINISH FOR (1) NEW CEILING FIXTURE. HOMEOWNERS UNDERSTAND THAT THE TYPE OF FIXTURE SELECTED MAY HAVE AN EFFECT ON INSTALLATION COST. 1 PROVIDE ROUGH IN AND FINISH FOR (2) NEW BACKSPLASH OUTLETS 1 PROVIDE POWER WHIP FOR (2) NEW ISLAND OUTLETS. CABINET INSTALLER TO CUT BOXES ON SITE. PROVIDE FINISH FOR OUTLETS. OUTLET STYLE TBD. 1 PROVIDE POWER IN ISLAND FOR THE FOLLOWING: SINGLE WALL OVEN, GARBAGE DISPOSAL WITH AIR SWITCH, DISHWASHER. 1 PROVIDE POWER IN NEW LOCATIONS FOR THE FOLLOWING APPLIANCES; SINGLE WALL OVEN, MICROWAVE, COOKTOP, HOOD INSERT, & REFRIGERATOR. 1 PROVIDE ROUGH IN AND INSTALL FOR (4) BACKSPLASH OUTLETS AS SHOWN 1 PROVIDE POWER FOR NEW WEATHERPROOF OUTLET AS SHOWN E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 E1 E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 PROPOSED PLUMBING PLAN NOTES NOTE QTY DESCRIPTION 1 PLUMBING DEMO AND DISCONNECT NOTES 1 FOLLOWING CONCRETE CUTTING, ROUGH IN FOR NEW DRAIN AND SUPPLY LINES FOR PROPOSED PLANS. PROVIDE ROUGH IN AND FINISH FOR (2) VANITY SINKS, (1) TOILET, (1) CURBLESS SHOWER DRAIN, SINGLE SHOWHEAD W/ VALVE, SHOWER WAND ON SLIDE BAR WITH VALVE. 1 FOLLOWING CONCRETE CUTTING, ROUGH IN FOR NEW DRAIN AND SUPPLY LINES FOR PROPOSED POWDER BATH AND LAUNDRY PLANS. PROVIDE ROUGH IN AND FINISH FOR (1) VANITY SINK, (1) TOILET, (1) LAUNDRY SINK & WASHER SUPPLY/DRAIN BOX AS SHOWN 1 FOLLOWING CONCRETE CUTTING, ROUGH IN FOR NEW DRAIN AND SUPPLY LINES FOR PROPOSED KITCHEN ISLAND. PROVIDE ROUGH IN AND FINISH FOR NEW KITCHEN SINK WITH SINGLE FAUCET AND GARBAGE DISPOSAL W/ AIR SWITCH 1 TRENCH ALONG EXTERIOR OF HOME AND RUN NEW GAS LINE FOR GAS DIRECT VENT FIREPLACE. PROVIDE STUB FOR GAS LINE PER FIREPLACE SPECS. P1 P2 P3 P4 P5 P1 P2 P3 P4 P5 PROPOSED LOW VOLTAGE PLAN NOTES NOTE QTY DESCRIPTION LV1 1 NONE INCLUDED IN CURRENT SCOPE OF WORK LAZZARA RESIDENCE Interior Remodel 308 Woodland Lane Carmel, IN 46032 Revision: Date: A4 SHEET OF 8 SIGNATURE / SEAL DESIGNER: TOM LAZZAARA E: tom@customlivingusa.com C: 317.289.5590 Client Initials: Date: The plans, including all text, drawings, concepts, and ideas forming a part of the plans and the selection and arrangement thereof are Copyright 2018 of Custom Living, Inc., Indianapolis, IN. ALL RIGHTS RESERVED. The plans shall remain the property of Custom Living Inc. Any use of the plans or their content without the prior written permission of Custom Living Inc. is strictly prohibited. CUSTOM LIVING 5335 Winthrop Ave Indianapolis IN 46220 5/21/2021 DATE: [PRINTS TO SCALE IF PRINTED ON 24" X 36" ] PROPOSED M.E.P. PLAN SCALE: 3/16" = 1' ISLAND OUTLETS NEW OUTLET DEVICE STYLE NEW SWITCH DEVICE STYLE RECESSED CAN LIGHTS DECORATIVE LIGHT FIXTURES UNDER CABINET LIGHTING NONE IN SCOPE TBD GENERAL M.E.P NOTES HVAC Contractor is responsible for engineering calculation necessary for correct sizing of new equipment and ductwork being supplied, fabricated and installed for the project. HVAC ductwork installed in unconditioned areas to be insulated and sealed per Building Code Standards. HVAC contractor to start, test, and balance any new equipment and ductwork to assure proper operation of new systems. Final plumbing materials selected may have an affect on the final Plumbing Material and Installation Budgets. Owners understand that if additional plumbing, electrical or ductwork is found in walls being deleted that is not included on the plans there will be a Change Order during construction to relocate as necessary. Owners understand that during mechanical rough-ins there will be times when the water service will be shut off to areas in the home. Plumbing and Lighting fixtures supplied by Owner will not be warranted by Custom Living Plumbing and Lighting fixtures supplied by Owner must be selected and on-site prior to start of mechanical rough-ins. 05/28/21