HomeMy WebLinkAboutM101.06" 3000K
MODEL NO.
6RLD G3
07LM 30K
90CRI 120
FRPC WWH
M6
DUPLEX
WHITE
TOGGLE
SWITCH
WHITE
REFRIGERATOR OUTLET
MICROWAVE OUTLET
DISHWASHER POWER SUPPLY
HOOD VENT POWER SUPPLY
GARBAGE DISPOSAL POWER SUPPLY
COOKTOP POWER SUPPLY
CLOTHES DRYER OUTLET
CLOTHES WASHER OUTLET
110V OUTLET
220/240V OUTLET
GFCI OUTLET
OUTDOOR OUTLET
LOW VOLTAGE TRANSFORMER
SINGLE POLE SWITCH
DIMMER SWITCH
3-WAY SWITCH
4-WAY SWITCH
GD WALL SWITCH
GD COUNTERTOP AIR SWITCH
LOW VOLTAGE LIGHTING SWITCH
TIMER SWITCH
OCCUPANCY SWITCH
SURFACE MOUNT LIGHT FIXTURE
4" RECESSED CAN LIGHT
6" RECESSED CAN LIGHT
6" RECESSED CAN/FAN UNIT
EXHAUST FAN ONLY
EXHAUST FAN W/ LIGHT
WALL MOUNTED SCONCE / LIGHT
CEILING FAN
LOW VOLTAGE LIGHT
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
SMOKE/CARBON MONOXIDE
MOTION SENSOR
CEILING SPEAKER
GAS SHUT-OFF KEY
MAIN WATER SHUT-OFF
LAUNDRY BOX
FROST PROOF HOSE BIB
CLEAN OUT
TILE-IN DRAIN
FLOOR DRAIN
COLD AIR RETURN
FLOOR FLOOR SUPPLY REGISTER
CEILING CEILING SUPPLY REGISTER
WALL WALL SUPPLY REGISTER
EXTERIOR WALL EXHAUST VENT
T THERMOSTAT
DRYER BOX
ELECTRICAL KEY
PLUMBING KEY
HVAC KEY
cL
cL c
L
cL
cL
cL
cL cL
cL
R
R
3
R
R
R
R R
R
R
WP
WP
3
R
R R
R R
R R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
3 3
R R R
3
R
3
3
R
T
3
R
R
R
3
R
R
R
GFCI GFCI
R
GFCI
3
3 3
CT
H
DW
GD
A
O
SD
SD
SD
CO/SD
CO/SD
M
O
GFCI
CW CD
6'
1'-7 3/4" 1'-7 3/4"
2'-5 1/2" 3'-6" 4'-9 1/2"
2'
2'-4 1/2"
1'-4"
2'-10" 1'-3"
4'-6"
6'-6 1/4"
7'-3 5/16"
5'-8"
H1
GARAGE
PORCH
E3
E4 E5
E6
E7
E8
E9
E9
E10
E11
E10
E12
E13
E11
E14
E11
E15
E16
E17
E17
E18
E20
E6
E19
E21
E11
E22
E23
E25
E26
E7
E7
E7
E11 E27
E28
E29
E30
E31
E32
P2
P3
P4
H2
H2
H3
H4
H5
H6
BEDROOM 1
BEDROOM 2
BEDROOM 3
FAMILY ROOM
LIVING ROOM
KITCHEN
HALLWAY
LAUNDRY
MUDROOM
POWDER
BATH
HALL BATH
HALL
P5
R
N
PROPOSED HVAC PLAN NOTES
NOTE QTY DESCRIPTION
1
RELOCATE ROUGH IN AND INSTALL NEW TOE KICK VENT IN
VANITY BASE
2
CONNECT NEW BATH FAN TO EXISTING EXTERIOR
EXHAUST VENT
1
CONNECT NEW BATH FAN TO EXISTING EXTERIOR
EXHAUST VENT LOCATED ABOVE WALL
1
INSTALL NEW EXTERIOR ROOF PENETRATION FOR BATH
VENT
1
RELOCATE EXISTING DRYER VENT IN WALL AND CONNECT
TO EXISTING EXTERIOR PENETRATION
1
INSTALL NEW DUCT AND EXTERIOR PENETRATION FOR
HOOD PER APPLIANCE SPECS
H1
H2
H3
H4
H5
H6
H1
H2
H3
H4
H5
H6
PROPOSED ELECTRICAL PLAN NOTES
NOTE QTY DESCRIPTION
1
ELECTRICIAN TO VERIFY EXISTING SMOKE AND CO
DETECTORS IN HOME MEET CURRENT MUNICIPAL CODE
REQUIREMENTS. IF ADDITIONAL WORK IS REQUIRED TO
BRING THEM UP TO CODE, THERE WILL BE AN ADDITIONAL
COST FOR LABOR AND MATERIALS.
1
ELECTRICIAN TO VERIFY ALL GFCI OUTLETS MEET
CURRENT MUNICIPAL CODE REQUIREMENTS.
1
PROVIDE ROUGH IN AND FINISH FOR (6) 6" RECESSED CAN
LIGHTS AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR (3) VANITY SCONCE
LIGHTS AS SHOWN. FINAL HEIGHTS TO BE DETERMINED ON
SITE DURING ROUGH IN. HOMEOWNERS UNDERSTAND THE
TYPE OF FIXTURE SELECTED MAY HAVE AN EFFECT ON
INSTALLATION COST.
1
PROVIDE ROUGH IN AND FINISH FOR (2) GFCI PROTECTED
VANITY OUTLETS.
2
PROVIDE ROUGH IN AND FINISH FOR (2) PANASONIC FAN
UNITS AS SHOWN. HVAC CONTRACTOR TO CONNECT FAN
TO EXTERIOR VENT.
4
PROVIDE ROUGH IN AND FINISH FOR ALL NEW SWITCHING
IN MASTER BATH AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR NEW WALL OUTLET.
PROVIDE EXTENSION CORD RUN IN CONDUIT ALONG TOP
OF BASEBOARD TO LOCATION OF TABLE LAMP. CUSTOM
LIVING TO SUPPLY EXTENSION CORD AND CONDUIT.
2
PROVIDE ROUGH IN AND FINISH FOR EXISTING FIXTURE IN
NEW LOCATION. FINAL LOCATION TO BE DETERMINED ON
SITE DURING ROUGH IN.
2
PROVIDE ROUGH IN AND FINISH FOR NEW FIXTURE AS
SHOWN. TIE FIXTURE INTO EXISTING SWITCHING.
5 PROVIDE ROUGH IN AND FINISH FOR NEW WALL OUTLET
1
DELETE EXISTING LIGHT AND MAKE A SWITCHED WALL
OUTLET. LOCATION TO BE DETERMINED ON SITE.
1
PROVIDE ROUGH IN AND FINISH FOR NEW 6" RECESSED
CAN FAN. USE EXISTING VENT LINE LOCATED ON WALL
ABOVE.
1
PROVIDE ROUGH IN AND FINISH FOR NEW DEDICATED
TESLA CHARGING OUTLET. LOCATION TO BE DETERMINED
ON SITE.
1
PROVIDE ROUGH IN AND FINISH FOR (7) NEW 6" RECESSED
CAN LIGHTS AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR NEW GFCI OUTLET,
WASHER OUTLET AND DEDICATED DRYER OUTLET AS
SHOWN. PROVIDE ROUGH IN AND FINISH FOR (4) 6" LED
RECESSED CANS AS SHOWN.
2
PROVIDE ROUGH IN AND FINISH FOR (1) LED CLOSET LIGHT
WITH JAMB ACTIVATED SWITCH AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR ALL NEW SWITCHING
AS SHOWN. PROVIDE ROUGH IN AND FINISH FOR (3) 6"
RECESSED CANS AS SHOWN.
1
PROVIDE ROUGH IN AND FINISH FOR GFCI PROTECTED
OUTLET AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR ALL NEW SWITCHING
AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR NEW FLUSH MOUNT
DECORATIVE FIXTURE AS SHOWN. HOMEOWNERS
UNDERSTAND THE TYPE OF FIXTURE SELECTED MAY HAVE
AN EFFECT ON INSTALLATION COST.
1
PROVIDE ROUGH IN AND FINISH FOR (5) NEW WALL
OUTLETS
1
PROVIDE ROUGH IN AND FINISH FOR (2) NEW WALL
SCONCES AS SHOWN
2
RUN CONDUIT FOR WIRRING AND INSTALL (2) NEW
WEATHERPROOF OUTLETS AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR (7) NEW 6" RECESSED
CAN FIXTURES AS SHOWN
1
PROVIDE ROUGH IN AND FINISH FOR (1) NEW CEILING
FIXTURE. HOMEOWNERS UNDERSTAND THAT THE TYPE OF
FIXTURE SELECTED MAY HAVE AN EFFECT ON
INSTALLATION COST.
1
PROVIDE ROUGH IN AND FINISH FOR (2) NEW BACKSPLASH
OUTLETS
1
PROVIDE POWER WHIP FOR (2) NEW ISLAND OUTLETS.
CABINET INSTALLER TO CUT BOXES ON SITE. PROVIDE
FINISH FOR OUTLETS. OUTLET STYLE TBD.
1
PROVIDE POWER IN ISLAND FOR THE FOLLOWING: SINGLE
WALL OVEN, GARBAGE DISPOSAL WITH AIR SWITCH,
DISHWASHER.
1
PROVIDE POWER IN NEW LOCATIONS FOR THE FOLLOWING
APPLIANCES; SINGLE WALL OVEN, MICROWAVE, COOKTOP,
HOOD INSERT, & REFRIGERATOR.
1
PROVIDE ROUGH IN AND INSTALL FOR (4) BACKSPLASH
OUTLETS AS SHOWN
1
PROVIDE POWER FOR NEW WEATHERPROOF OUTLET AS
SHOWN
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31
E32
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31
E32
PROPOSED PLUMBING PLAN NOTES
NOTE QTY DESCRIPTION
1 PLUMBING DEMO AND DISCONNECT NOTES
1
FOLLOWING CONCRETE CUTTING, ROUGH IN FOR NEW
DRAIN AND SUPPLY LINES FOR PROPOSED PLANS.
PROVIDE ROUGH IN AND FINISH FOR (2) VANITY SINKS, (1)
TOILET, (1) CURBLESS SHOWER DRAIN, SINGLE SHOWHEAD
W/ VALVE, SHOWER WAND ON SLIDE BAR WITH VALVE.
1
FOLLOWING CONCRETE CUTTING, ROUGH IN FOR NEW
DRAIN AND SUPPLY LINES FOR PROPOSED POWDER BATH
AND LAUNDRY PLANS. PROVIDE ROUGH IN AND FINISH FOR
(1) VANITY SINK, (1) TOILET, (1) LAUNDRY SINK & WASHER
SUPPLY/DRAIN BOX AS SHOWN
1
FOLLOWING CONCRETE CUTTING, ROUGH IN FOR NEW
DRAIN AND SUPPLY LINES FOR PROPOSED KITCHEN
ISLAND. PROVIDE ROUGH IN AND FINISH FOR NEW KITCHEN
SINK WITH SINGLE FAUCET AND GARBAGE DISPOSAL W/
AIR SWITCH
1
TRENCH ALONG EXTERIOR OF HOME AND RUN NEW GAS
LINE FOR GAS DIRECT VENT FIREPLACE. PROVIDE STUB
FOR GAS LINE PER FIREPLACE SPECS.
P1
P2
P3
P4
P5
P1
P2
P3
P4
P5
PROPOSED LOW VOLTAGE PLAN NOTES
NOTE QTY DESCRIPTION
LV1 1 NONE INCLUDED IN CURRENT SCOPE OF WORK
LAZZARA RESIDENCE
Interior Remodel
308 Woodland Lane
Carmel, IN 46032
Revision: Date:
A4
SHEET OF 8
SIGNATURE / SEAL
DESIGNER: TOM LAZZAARA
E: tom@customlivingusa.com
C: 317.289.5590
Client Initials:
Date:
The plans, including all text, drawings, concepts, and ideas
forming a part of the plans and the selection and arrangement
thereof are Copyright 2018 of Custom Living, Inc., Indianapolis,
IN. ALL RIGHTS RESERVED. The plans shall remain the
property of Custom Living Inc. Any use of the plans or their
content without the prior written permission of Custom Living Inc.
is strictly prohibited.
CUSTOM LIVING
5335 Winthrop Ave
Indianapolis IN 46220
5/21/2021
DATE:
[PRINTS TO SCALE IF PRINTED ON 24" X 36" ]
PROPOSED M.E.P. PLAN
SCALE: 3/16" = 1'
ISLAND
OUTLETS
NEW OUTLET DEVICE STYLE
NEW SWITCH DEVICE STYLE
RECESSED CAN LIGHTS
DECORATIVE LIGHT FIXTURES
UNDER CABINET LIGHTING
NONE IN SCOPE
TBD
GENERAL M.E.P NOTES
HVAC Contractor is responsible for engineering
calculation necessary for correct sizing of new
equipment and ductwork being supplied, fabricated
and installed for the project.
HVAC ductwork installed in unconditioned areas to be
insulated and sealed per Building Code Standards.
HVAC contractor to start, test, and balance any new
equipment and ductwork to assure proper operation of
new systems.
Final plumbing materials selected may have an affect
on the final Plumbing Material and Installation Budgets.
Owners understand that if additional plumbing,
electrical or ductwork is found in walls being deleted
that is not included on the plans there will be a Change
Order during construction to relocate as necessary.
Owners understand that during mechanical rough-ins
there will be times when the water service will be shut
off to areas in the home.
Plumbing and Lighting fixtures supplied by Owner will
not be warranted by Custom Living
Plumbing and Lighting fixtures supplied by Owner must
be selected and on-site prior to start of mechanical
rough-ins.
05/28/21