HomeMy WebLinkAbout051121 A-00 General Information(2) 2x12 HDR (2) 2x12 HDR SEE FLOOR PLANS AND WALL SECTION FOR TOP PLATE HEIGHTS SEE FLOOR PLANS FOR HEADER HEIGHTS KING AND JACK STUDS DOOR WDW 1'-8" 8" MIN 2'-8" MINIMUM 1'-2" 8'-0" 2'-8" BRICK 12" CMU FOUNDATION CONCRETE FOOTING 1x6 CEDAR TRIM AROUND POSTS BRICK VENEER WITH WALL TIES 1/2" ROOF SHEATHING 30# ROOFING FELT FIBERGLASS SHINGLES METAL DRIP EDGE GUTTER 2x8 SUB FASCIA 1x8 CEDAR FASCIA 3/8" VENTILATED SOFFIT 1x4 CEDAR TRIM AROUND POSTS 2x8 RAFTERS AT 16" O.C. 12 8 1x6 CEDAR BEAM TRIM SQUARE CUT LIMESTONE CAP AIR SPACE PRESSURE-TREATED 2x4 BOTTOM PLATE ANCHOR BOLT 4" CONCRETE BLOCK WEEP VENTS AND FLASHING 2x4 WALL STUD PAVERS OVER 1' SAND AND MINIMUM 4" OF COMPACTED BASE INSTALLED PER I.C.P.I. LINE OF PIER AND POST BEYOND 1/2" PLYWOOD SHEATHING AIR INFILTRATION BARRIER 1x12 CEDAR BEAM TRIM DOUBLE 12" LVL BEAM 1X6 CEDAR TRIM BEADED PLYWOOD CEILING PLAN DETAIL 1x6 CEDAR TRIM AROUND POSTS C 2021 SURROUNDINGS THIS PLAN IS PROPERTY OF SURROUNDINGS. ANY UNAUTHORIZED USE OR REPRODUCTION OF THIS PLAN, IN WHOLE OR IN PART IS PROHIBITED. SURROUNDINGS WILL USE ALL LEGAL MEANS AVAILABLE TO PURSUE THE UNAUTHORIZED USE OF THIS PLAN OR ANY DESIGN ELEMENTS CONTAINED THEREIN. Carlberg Residence Freestanding Lanai and Patio Queens Manor - Section 2 - Lot 19 11066 Queens Way Circle Carmel, Indiana 46032 Date 05.11.21 Indiana Design Centert 200 S. Rangeline Road Suite 120A Carmel, Indiana 46032 Area Location Map NO SCALE Typical Wall Section SCALE: 1/2" = 1'-0" Description General Information Sheet Number Typical Door and Window Framing A-00 SCALE: 1/4" = 1'-0" PROPOSED SQUARE FOOTAGE TABLE GARAGE 925 SF ROOM ADDITION 604 SF LOT 4.71 ACRES SF SF SECOND FLOOR FIRST FLOOR 2462 1878 BASEMENT (FINISHED AND UNFINISHED) 2270 SF PAVER PATIO - INCLUDING PAVERS BELOW LANAI 853 SF LANAI - LOCATED WITHIN AREA OF PATIO 225 SF GENERAL NOTES: THE BUILDER SHALL VERIFY THAT SITE CONDITIONS ARE CONSISTENT WITH THESE PLANS BEFORE STARTING WORK. WORK NOT SPECIFICALLY DETAILED SHALL BE CONSTRUCTED TO THE SAME QUALITY AS SIMILAR WORK THAT IS DETAILED. ALL WORK SHALL BE DONE IN ACCORDANCE WITH INTERNATIONAL BUILDING CODES AND LOCAL CODES. WRITTEN DIMENSIONS AND SPECIFIC NOTES SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND GENERAL NOTES. THE ENGINEER/DESIGNER SHALL BE CONSULTED FOR CLARIFICATION IF SITE CONDITIONS ARE ENCOUNTERED THAT ARE DIFFERENT THAN SHOWN, IF DISCREPANCIES ARE FOUND IN THE PLANS OR NOTES, OR IF A QUESTION ARISES OVER THE INTENT OF THE PLANS OR NOTES. CONTRACTOR SHALL VERIFY AND IS RESPONSIBLE FOR ALL DIMENSIONS (INCLUDING ROUGH OPENINGS). SEE ADDITIONAL NOTES CALLED OUT ON OTHER SHEETS. BUILDING PERFORMANCE: HEAT LOSS CALCULATIONS SHALL COMPLY WITH THE REQUIREMENTS OF REGIONAL AND LOCAL CODES. ALL EXHAUST FANS TO BE VENTED DIRECTLY TO THE EXTERIOR. ALL PENETRATIONS OF THE BUILDING ENVELOPE SHALL BE SEALED WITH CAULK OR FOAM. 06/03/21