HomeMy WebLinkAboutMERIDIAN II A TRUSS ENGINEERING 1600294Re:
IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed
in the jurisdictions(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific
information included is for MiTek’s customer’s file reference purpose only, and was not taken into account in the preparation
of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any
particular building. Before use, the building designer should verify applicability of the design parameters and properly
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
The truss drawing(s) referenced below have been prepared by MiTek USA, Inc. under my direct supervision
based on the parameters provided by Timberland Home Center-Brazil, IN.
Liu, Xuegang
MERIDIAN II A
Pages or sheets covered by this seal: I26730595 thru I26730619
My license renewal date for the state of Indiana is July 31, 2018.
1600294
16023 Swingley Ridge Rd
Chesterfield, MO 63017
314-434-1200
MiTek USA, Inc.
May 12,2016
Job
1600294
Truss
A
Truss Type
COMMON
Qty
5
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730595
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:26 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-RYUIb_oq2C8967r65f8QukUDv1jjZsbDaYR2rrzHbBF
Scale = 1:66.9
1
2
3
4
5
6
7
8
9 10
16 15 14 13 12 11
17 183x6
5x6
3x6
3x8
4x6 3x4
2x4
3x4
3x8
3x4
3x4
3x6
3x6
3x4
4x6
10-6-5
10-6-5
20-3-1
9-8-12
29-11-12
9-8-12
40-0-0
10-0-4
8-1-6
8-1-6
15-5-3
7-3-13
22-9-0
7-3-13
28-4-13
5-7-13
34-0-11
5-7-13
40-0-0
5-11-5
41-5-4
1-5-4
0-4-07-11-02-2-04.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.92
0.91
0.76
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.27
-0.80
0.18
(loc)
1-16
1-16
11
l/defl
>999
>599
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 172 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
3-5: 2x4 SPF-S 1650F 1.6E, 1-3: 2x4 SP 2400F 2.0E
BOT CHORD 2x4 SP 2400F 2.0E *Except*
13-15: 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
7-14: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-14, 7-14, 8-11
REACTIONS.(lb/size)1=1586/0-3-8, 11=1685/0-3-8
Max Horz 1=15(LC 7)
Max Uplift 1=-186(LC 6), 11=-252(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-4063/526, 2-4=-3727/470, 4-5=-2518/384, 5-7=-2122/354, 7-8=-2455/336,
9-11=-302/147
BOT CHORD 1-16=-431/3795, 14-16=-271/2922, 12-14=-163/2284, 11-12=-193/2023
WEBS 2-16=-481/206, 4-16=-28/797, 4-14=-992/216, 5-14=-105/1125, 7-14=-602/86,
8-12=0/405, 8-11=-2327/279
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=186, 11=252.
7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
AGR
Truss Type
GABLE
Qty
1
Ply
2
MERIDIAN II A
Job Reference (optional)
I26730596
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:27 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-vk2goKpTpWG0kHQIfMffQy1YBR9zIN5MpCBbNHzHbBE
Scale = 1:54.9
1
2
3
4
5
6
7
8
13 12 11 10 9
36
37 38 39 40 41
3x4
3x6 4x6 3x4
3x4
3x4
4x6 4x6
4x12
3x4
3x4
3x4
7-7-13
7-7-13
14-0-1
6-4-4
20-4-4
6-4-4
27-0-0
6-7-12
-1-5-4
1-5-4
6-7-15
6-7-15
12-0-5
5-4-6
17-4-10
5-4-6
22-9-0
5-4-6
27-0-0
4-3-0
0-4-07-11-06-6-04.00 12
Plate Offsets (X,Y)-- [2:0-3-5,0-0-13], [6:0-1-3,0-1-8], [7:0-0-9,0-1-8], [27:0-1-11,0-1-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.31
0.52
0.49
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.10
-0.21
0.04
(loc)
10-11
10-11
9
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 376 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
7-9: 2x4 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)2=1513/0-3-8, 9=1916/0-3-8
Max Horz 2=80(LC 6)
Max Uplift 2=-228(LC 6), 9=-243(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3685/421, 3-5=-3516/422, 5-6=-2831/388, 6-7=-1586/281
BOT CHORD 2-13=-403/3439, 11-13=-311/2874, 10-11=-186/1992, 9-10=-19/879
WEBS 3-13=-349/142, 5-13=-38/690, 5-11=-577/140, 6-11=-123/1275, 6-10=-1180/221,
7-10=-217/1896, 7-9=-1814/202
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
4) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
5) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
6) Unbalanced snow loads have been considered for this design.
7) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
8) All plates are 2x4 MT20 unless otherwise indicated.
9) Vertical gable studs spaced at 1-4-0 oc and horizontal gable studs spaced at 2-0-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
2=228, 9=243.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 596 lb down and 68 lb up at
16-0-12, 120 lb down and 27 lb up at 18-0-12, 120 lb down and 27 lb up at 20-0-12, 120 lb down and 27 lb up at 22-0-12, and 120
lb down and 27 lb up at 24-0-12, and 122 lb down and 25 lb up at 26-0-12 on bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.Continued on page 2
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
AGR
Truss Type
GABLE
Qty
1
Ply
2
MERIDIAN II A
Job Reference (optional)
I26730596
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:27 2016 Page 2 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-vk2goKpTpWG0kHQIfMffQy1YBR9zIN5MpCBbNHzHbBE
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-7=-60, 7-8=-60, 2-9=-20
Concentrated Loads (lb)
Vert: 10=-120(B) 37=-596(B) 38=-120(B) 39=-120(B) 40=-120(B) 41=-122(B)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Job
1600294
Truss
AS
Truss Type
COMMON
Qty
4
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730597
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:28 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-Nwc20gq5ZqOtLR?VD3Auz9aaFrPX1ouW1sw9vjzHbBD
Scale = 1:48.8
1
2
3
4
5
6
10 9 8 7
11
3x4
4x12
2x4
3x6 3x4 3x6
2x4
3x6
3x6 3x6
9-5-3
9-5-3
18-0-14
8-7-10
27-0-0
8-11-2
8-1-6
8-1-6
15-5-3
7-3-13
22-9-0
7-3-13
27-0-0
4-3-0
0-4-07-11-06-6-04.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.86
0.95
0.58
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.24
-0.68
0.08
(loc)
1-10
1-10
7
l/defl
>999
>471
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 108 lb FT = 0%
GRIP
169/123
LUMBER-
TOP CHORD 2x4 SPF No.2 *Except*
1-3: 2x4 SPF-S 1650F 1.6E
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-8,5-7: 2x4 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 1 Row at midpt 5-7
REACTIONS.(lb/size)1=1068/0-3-8, 7=1068/0-3-8
Max Horz 1=69(LC 7)
Max Uplift 1=-119(LC 6), 7=-131(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-2497/310, 2-4=-2292/310, 4-5=-1192/221
BOT CHORD 1-10=-289/2315, 8-10=-132/1400, 7-8=0/489
WEBS 2-10=-459/193, 4-10=-91/932, 4-8=-801/220, 5-8=-105/1052, 5-7=-1007/119
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=119, 7=131.
6) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
AS1
Truss Type
MONO TRUSS
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730598
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:28 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-Nwc20gq5ZqOtLR?VD3Auz9ac0rTM1qoW1sw9vjzHbBD
Scale = 1:33.0
1
2
3
4
5
6
9 8 7
10
3x8
3x4
3x6 3x4 3x4
3x4
2x4
8-3-1
8-3-1
16-0-0
7-8-15
-1-5-4
1-5-4
8-3-1
8-3-1
16-0-0
7-8-15
17-11-4
1-11-4
0-4-06-3-125-8-04.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.75
0.64
0.46
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.11
-0.33
0.03
(loc)
2-9
2-9
7
l/defl
>999
>571
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 59 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-1-5 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 3-7
REACTIONS.(lb/size)7=757/Mechanical, 2=720/0-3-8
Max Horz 2=99(LC 6)
Max Uplift 7=-188(LC 6), 2=-124(LC 6)
Max Grav 7=940(LC 9), 2=735(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1220/71, 5-7=-487/173
BOT CHORD 2-9=-81/1090, 7-9=-81/1090
WEBS 3-9=0/371, 3-7=-1136/163
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
7=188, 2=124.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
ASG
Truss Type
GABLE
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730599
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:28 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-Nwc20gq5ZqOtLR?VD3Auz9agLraF1wjW1sw9vjzHbBD
Scale = 1:33.5
1
2
3
4
5
6
7
8 9
10
11
12
13
23 22 21 20 19 18 17 16 15 14
24
5x6
3x4
3x4
16-0-0
16-0-0
-1-5-4
1-5-4
16-0-0
16-0-0
17-11-4
1-11-4
0-4-06-3-125-8-04.00 12
Plate Offsets (X,Y)-- [8:0-3-0,0-3-4]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.47
0.20
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.03
0.00
(loc)
12
12-13
14
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 76 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 16-0-0.
(lb) - Max Horz 2=99(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 2, 20, 23, 19, 18, 17, 16 except 14=-161(LC 6), 21=-118(LC 12),
15=-117(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 20, 19, 18, 17, 16, 15 except 14=394(LC 8), 2=271(LC 1),
23=483(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 12-14=-392/207
WEBS 3-23=-337/125
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are 2x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 20, 23, 19, 18,
17, 16 except (jt=lb) 14=161, 21=118, 15=117.
11) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
B
Truss Type
SPECIAL
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730600
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:29 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-r7ARD0qjK7Wkzbahnnh7WN6oVFsxmALfGWgiS9zHbBC
Scale = 1:41.9
1
2
3
4
5
9
8
7
6
103x4
3x6
3x4
3x4
3x4
3x4
3x8 3x8
7-5-8
7-5-8
14-5-8
7-0-0
14-11-0
0-5-8
7-5-8
7-5-8
14-11-0
7-5-8
17-4-4
2-5-4
2-4-08-1-73-9-33-6-84-6-154.00 12
3.00 12
Plate Offsets (X,Y)-- [4:0-0-11,0-1-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.70
0.49
0.95
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.19
0.02
(loc)
8-9
8-9
6
l/defl
>999
>925
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 65 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-6: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-10-7 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)9=567/0-3-8, 6=756/0-5-8
Max Horz 9=184(LC 6)
Max Uplift 9=-21(LC 6), 6=-248(LC 6)
Max Grav 9=573(LC 12), 6=921(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1005/99, 4-6=-520/213, 1-9=-525/101
BOT CHORD 6-8=-185/939
WEBS 2-6=-880/236, 1-8=0/819
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Bearing at joint(s) 9, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb)
6=248.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
B1
Truss Type
SPECIAL
Qty
6
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730601
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:29 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-r7ARD0qjK7Wkzbahnnh7WN6oVFsFmBVfGWgiS9zHbBC
Scale = 1:41.6
1
2
3
4
5
9
8
7
6
103x4
4x6
3x4
3x4
3x4
2x8
3x8
3x8
7-3-12
7-3-12
14-2-0
6-10-4
14-7-8
0-5-8
7-3-12
7-3-12
14-7-8
7-3-12
17-0-12
2-5-4
2-4-58-0-93-9-33-5-104-6-154.00 12
3.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.70
0.47
0.87
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.07
-0.17
0.01
(loc)
8-9
8-9
6
l/defl
>999
>982
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 64 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
4-6: 2x6 SPF No.2
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-0-15 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)9=555/0-3-8, 6=745/0-5-8
Max Horz 9=182(LC 6)
Max Uplift 9=-21(LC 6), 6=-248(LC 6)
Max Grav 9=562(LC 12), 6=906(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-963/96, 4-6=-514/212, 1-9=-514/99
BOT CHORD 6-8=-179/895
WEBS 2-6=-843/232, 1-8=0/782
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Bearing at joint(s) 9, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=lb)
6=248.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
BG
Truss Type
GABLE
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730602
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:30 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-JJkpQMrL5Rebbl9tKUDM2afxcfGtVpOpVAPF_czHbBB
Scale = 1:42.6
1
2 3
4
5
6
7
8
9
10
11
12
13 14
15
28 27 26
25 24
23
22
21 20
19 18
17 16
29
4x6
4x6
3x6
6x8
5x6
5x6
14-5-8
14-5-8
14-11-0
0-5-8
-1-11-4
1-11-4
14-11-0
14-11-0
17-4-4
2-5-4
2-4-08-1-73-9-30-8-84.00 12
3.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [11:0-3-0,0-3-0], [19:0-3-0,0-3-0]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.81
0.26
0.13
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.05
-0.00
(loc)
15
15
16
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 80 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
14-16: 2x6 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 14-11-0.
(lb) - Max Horz 28=221(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 22, 23, 24, 25, 21 except 16=-847(LC 6), 27=-379(LC 6),
19=-184(LC 6), 17=-256(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 22, 23, 24, 25, 26, 27, 21, 20, 19, 18 except 28=412(LC 8),
16=608(LC 8), 17=700(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-28=-440/0, 14-16=-631/534
WEBS 13-17=-357/294
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) All plates are 2x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
9) Gable studs spaced at 1-4-0 oc.
10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) Bearing at joint(s) 16, 18, 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should
verify capacity of bearing surface.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 22, 23, 24, 25,
21 except (jt=lb) 16=847, 27=379, 19=184, 17=256.
13) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 16, 22, 23, 24, 25, 26, 27, 21, 20, 19, 18,
17.
14) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
BG1
Truss Type
GABLE
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730603
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:31 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-nVIBeiszslmSDvk4uCkbboC5M2cuEHqyjq9pW2zHbBA
Scale = 1:32.4
1
2
3
4
5
6
11 10 9
8
7
12
3x4
2x8
2x8
3x6
2x4
2x4
2x4
2x4
2x4
2x4
4-10-8
4-10-8
5-4-0
5-4-0
7-9-4
2-5-4
3-2-75-9-90-3-104-8-30-3-104-6-151-2-104.00 12
3.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.81
0.21
0.12
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.05
-0.00
(loc)
6
6
7
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 34 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3 *Except*
5-7: 2x6 SPF No.2
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 5-4-0.
(lb) - Max Horz 11=109(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 11, 9 except 7=-517(LC 6), 10=-197(LC 6), 8=-284(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 11, 9, 10 except 7=590(LC 8), 8=434(LC 6)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-7=-547/385
WEBS 4-8=-262/265
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
6) Gable requires continuous bottom chord bearing.
7) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).
8) Gable studs spaced at 1-4-0 oc.
9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
10) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11, 9 except
(jt=lb) 7=517, 10=197, 8=284.
12) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 11, 7, 9, 10, 8.
13) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
FGR
Truss Type
MONO TRUSS
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730604
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:31 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-nVIBeiszslmSDvk4uCkbboCDh2RrEIfyjq9pW2zHbBA
Scale = 1:11.1
1
2
3
4
5
6
2x4
2x4
3x4 3x4
4-0-0
4-0-0
-1-5-4
1-5-4
4-0-0
4-0-0
0-4-01-8-04.00 12
Plate Offsets (X,Y)-- [2:0-3-5,Edge]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.27
0.91
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.04
-0.07
0.00
(loc)
2-4
2-4
4
l/defl
>999
>610
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 15 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x6 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-3-0 oc bracing.
REACTIONS.(lb/size)4=604/Mechanical, 2=1092/0-3-8
Max Horz 2=46(LC 6)
Max Uplift 4=-68(LC 6), 2=-258(LC 6)
Max Grav 4=616(LC 9), 2=1096(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
2=258.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 385 lb down and 105 lb up at
0-1-12, and 920 lb down and 87 lb up at 2-0-12 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Snow (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-3=-60, 2-4=-20
Concentrated Loads (lb)
Vert: 2=-384 6=-920(F)
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
G
Truss Type
MONO TRUSS
Qty
5
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730605
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:32 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-FirZr2tbd2uJq2JGSvFq7?kP1SyCzkv5yUuM2UzHbB9
Scale = 1:11.1
1
2
3
4
5
2x4
2x4
2x4
4-0-0
4-0-0
-1-5-4
1-5-4
4-0-0
4-0-0
0-4-01-8-04.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.24
0.14
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
-0.01
-0.03
0.00
(loc)
2-4
2-4
4
l/defl
>999
>999
n/a
L/d
240
180
n/a
PLATES
MT20
Weight: 12 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)4=128/Mechanical, 2=264/0-3-8
Max Horz 2=43(LC 6)
Max Uplift 4=-28(LC 6), 2=-117(LC 6)
Max Grav 4=140(LC 9), 2=268(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
2=117.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V1
Truss Type
GABLE
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730606
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:32 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-FirZr2tbd2uJq2JGSvFq7?kM0Sxrzjg5yUuM2UzHbB9
Scale = 1:38.7
1
2 3
4
5
6
7
8
9
10
11
12
13
14
26 25 24 23 22 21 20 19 18 17 16 15
4x6
4x6
2x8
7x12
14-0-0
14-0-0
-1-11-4
1-11-4
14-0-0
14-0-0
16-5-4
2-5-4
1-11-17-4-136-7-14.00 12
Plate Offsets (X,Y)-- [2:0-3-0,0-1-12], [11:0-6-0,0-4-8]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.43
0.22
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.02
0.00
(loc)
14
13-14
15
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 98 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 14-0-0.
(lb) - Max Horz 26=120(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 17, 19, 20, 21, 22, 23, 24 except 15=-222(LC 6), 16=-100(LC 8),
25=-384(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 16, 17, 18, 19, 20, 21, 22, 23, 24, 25 except 26=466(LC 8),
15=490(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-26=-453/0, 13-15=-486/272
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 17, 19, 20, 21, 22,
23, 24 except (jt=lb) 15=222, 16=100, 25=384.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V2
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730607
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:35 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-gHXiU3vUwzGuhW1r72oXleMueg?RA4HYeS70fpzHbB6
Scale = 1:31.3
1
2
3
4
5
6
7
8
13 12 11 10 9
3x6
4x6
14-0-0
14-0-0
-1-11-4
1-11-4
14-0-0
14-0-0
16-5-4
2-5-4
1-3-16-8-135-11-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.34
0.10
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.02
0.00
(loc)
8
7-8
9
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 66 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 14-0-0.
(lb) - Max Horz 13=120(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 13, 10, 11, 12 except 9=-173(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 12 except 13=356(LC 8), 9=493(LC 9), 10=308(LC 9),
11=347(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-13=-342/47, 7-9=-462/201
WEBS 4-11=-266/129
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) All plates are 2x4 MT20 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 10, 11, 12
except (jt=lb) 9=173.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V3
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730608
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:35 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-gHXiU3vUwzGuhW1r72oXleMvXgzmA4KYeS70fpzHbB6
Scale: 3/8"=1’
1
2
3
4
5
6
7
10 9 8
4x6
2x4
2x4 3x4
2x4
2x4
2x4
2x4
14-0-0
14-0-0
-1-11-4
1-11-4
14-0-0
14-0-0
16-5-4
2-5-4
0-7-16-0-135-3-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.21
0.08
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.02
0.00
(loc)
7
6-7
8
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 62 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 14-0-0.
(lb) - Max Horz 2=109(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 2, 9, 10 except 8=-174(LC 6)
Max Grav All reactions 250 lb or less at joint(s) except 8=501(LC 9), 2=336(LC 1), 9=265(LC 9), 10=476(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 6-8=-467/202
WEBS 3-10=-360/156
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 9, 10 except
(jt=lb) 8=174.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V4
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730609
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:36 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-8T54hPw6hHOlJgc1hlJmIrv4G3LKvXoht6saBFzHbB5
Scale = 1:28.7
1
2
3 4
5
6
9 8 7
4x6
2x4
2x4
3x4
2x4
2x4
2x4
2x4
13-9-2
13-9-2
13-9-2
13-9-2
16-2-6
2-5-4
5-4-134-7-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.12
0.07
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.02
0.00
(loc)
6
5-6
7
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 53 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.All bearings 13-9-2.
(lb) - Max Horz 1=80(LC 6)
Max Uplift All uplift 100 lb or less at joint(s) 8, 9 except 7=-177(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 1 except 7=474(LC 9), 8=273(LC 12), 9=407(LC 1)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-7=-442/202
WEBS 2-9=-311/145
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 9 except (jt=lb)
7=177.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V5
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730610
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:36 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-8T54hPw6hHOlJgc1hlJmIrv4G3I4vXZht6saBFzHbB5
Scale = 1:24.9
1
2
3
4
5
7 6
8
4x6
2x4
2x4 3x4 2x4
2x4
11-9-2
11-9-2
11-9-2
11-9-2
14-2-6
2-5-4
4-8-133-11-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.27
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.00
-0.03
0.00
(loc)
5
5
6
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 44 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.(lb/size)6=279/11-9-2, 1=216/11-9-2, 7=496/11-9-2
Max Horz 1=78(LC 6)
Max Uplift 6=-166(LC 6), 1=-7(LC 6), 7=-74(LC 6)
Max Grav 6=393(LC 9), 1=221(LC 12), 7=518(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 4-6=-377/183
WEBS 2-7=-377/142
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7 except (jt=lb)
6=166.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V6
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730611
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:36 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-8T54hPw6hHOlJgc1hlJmIrv4G3K6vY?ht6saBFzHbB5
Scale = 1:23.4
1
2
3
4
6 5
7
3x4
2x4
2x4 2x4
2x4
9-9-2
9-9-2
12-2-6
2-5-4
4-0-133-3-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.14
0.06
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.02
0.00
(loc)
4
4
5
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 37 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS.(lb/size)1=151/9-9-2, 5=322/9-9-2, 6=358/9-9-2
Max Horz 1=76(LC 6)
Max Uplift 1=-2(LC 6), 5=-181(LC 6), 6=-54(LC 6)
Max Grav 1=155(LC 12), 5=416(LC 9), 6=384(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 3-5=-389/202
WEBS 2-6=-277/107
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 6 except (jt=lb)
5=181.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V7
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730612
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:37 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-cffSulxkSbXcxqBDFSr?q3SF0TWze?8r6mc7kizHbB4
Scale = 1:19.8
1
2
3
4
5
3x4
2x4
2x4
7-9-2
7-9-2
10-2-6
2-5-4
3-4-132-7-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.80
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.03
0.03
0.00
(loc)
3
3
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 29 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=227/7-9-2, 4=444/7-9-2
Max Horz 1=72(LC 6)
Max Uplift 1=-13(LC 6), 4=-208(LC 6)
Max Grav 1=246(LC 12), 4=510(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-445/247
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
4=208.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V8
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730613
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:37 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-cffSulxkSbXcxqBDFSr?q3SFVTdue?8r6mc7kizHbB4
Scale = 1:16.6
1
2
3
4
3x4
2x4
2x4
5-9-2
5-9-2
8-2-6
2-5-4
2-8-131-11-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.32
0.36
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.00
0.00
(loc)
3
3
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 22 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-9-2 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=133/5-9-2, 4=378/5-9-2
Max Horz 1=67(LC 6)
Max Uplift 4=-207(LC 6)
Max Grav 1=157(LC 12), 4=422(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-378/233
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=207.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V9
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730614
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:38 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-4rDq65xMDufSYzmQoAMENG_Qqt0CNSO_KQLgG8zHbB3
Scale = 1:13.2
1
2
3
4
5
6
3x4
2x4
2x4
3-9-2
3-9-2
6-2-6
2-5-4
2-0-131-3-14.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.28
0.10
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
0.01
-0.01
0.00
(loc)
3
3
4
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 15 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x6 SPF No.2
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-9-2 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=16/3-9-2, 4=335/3-9-2
Max Horz 1=58(LC 6)
Max Uplift 1=-87(LC 8), 4=-214(LC 6)
Max Grav 1=65(LC 7), 4=443(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-419/229
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 20.0 psf on overhangs
non-concurrent with other live loads.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)
4=214.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V10
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730615
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:33 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-kuPx3NtDOM0ASCtS0dm3gDHYPsHTiAnFB8evbxzHbB8
Scale = 1:20.3
1
2
3
5 42x4
2x4
2x4 2x4
2x4
10-4-2
10-4-2
3-5-64.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.32
0.20
0.09
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
4
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 28 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
OTHERS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=176/10-4-2, 4=96/10-4-2, 5=472/10-4-2
Max Horz 1=38(LC 7)
Max Uplift 1=-17(LC 6), 4=-8(LC 6), 5=-112(LC 6)
Max Grav 1=179(LC 11), 4=126(LC 8), 5=507(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 2-5=-380/170
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4 except (jt=lb)
5=112.
7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V11
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730616
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:33 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-kuPx3NtDOM0ASCtS0dm3gDHOvsBJiB9FB8evbxzHbB8
Scale = 1:17.4
1
2
3
4
2x4
2x4
2x4
8-4-2
8-4-2
2-9-64.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
1.00
0.59
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 21 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF No.2
BOT CHORD 2x4 SPF No.2
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=292/8-4-2, 3=292/8-4-2
Max Horz 1=30(LC 7)
Max Uplift 1=-58(LC 6), 3=-67(LC 6)
Max Grav 1=299(LC 11), 3=322(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V12
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730617
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:33 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-kuPx3NtDOM0ASCtS0dm3gDHQ8sCOiB9FB8evbxzHbB8
Scale = 1:13.7
1
2
3
4
2x4
2x4
2x4
6-4-2
6-4-2
2-1-64.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.85
0.52
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 16 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=212/6-4-2, 3=212/6-4-2
Max Horz 1=24(LC 6)
Max Uplift 1=-49(LC 6), 3=-57(LC 6)
Max Grav 1=220(LC 11), 3=225(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V13
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730618
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:34 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-C4zKGjus9g814MSfZKHIDQqkbGetRePOQoNT7NzHbB7
Scale = 1:10.0
1
2
3
4
2x4
2x4
2x4
4-4-2
4-4-2
1-5-64.00 12
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.30
0.19
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 10 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 4-4-2 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=132/4-4-2, 3=132/4-4-2
Max Horz 1=16(LC 6)
Max Uplift 1=-33(LC 6), 3=-38(LC 6)
Max Grav 1=137(LC 11), 3=134(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
Job
1600294
Truss
V14
Truss Type
VALLEY
Qty
1
Ply
1
MERIDIAN II A
Job Reference (optional)
I26730619
8.010 s Apr 20 2016 MiTek Industries, Inc. Wed May 11 11:11:34 2016 Page 1 Timberland Lumber Company, Indianapolis, IN 46222
ID:PFP5c1pPuD63pq5OgEa411zKHes-C4zKGjus9g814MSfZKHIDQqoGGgCRePOQoNT7NzHbB7
Scale = 1:7.1
1
2
3
2x4
5x6
2-7-10
2-7-10
0-10-94.00 12
Plate Offsets (X,Y)-- [2:0-2-12,0-1-13]
LOADING (psf)
TCLL
(Roof Snow=20.0)
TCDL
BCLL
BCDL
20.0
10.0
0.0
10.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IBC2012/TPI2007
CSI.
TC
BC
WB
Matrix-S
0.06
0.04
0.00
DEFL.
Vert(LL)
Vert(TL)
Horz(TL)
in
n/a
n/a
0.00
(loc)
-
-
3
l/defl
n/a
n/a
n/a
L/d
999
999
n/a
PLATES
MT20
Weight: 5 lb FT = 0%
GRIP
197/144
LUMBER-
TOP CHORD 2x4 SPF Stud/No.3
BOT CHORD 2x4 SPF Stud/No.3
WEBS 2x4 SPF Stud/No.3
BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-7-10 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)1=64/2-7-10, 3=64/2-7-10
Max Horz 1=8(LC 6)
Max Uplift 1=-16(LC 6), 3=-18(LC 6)
Max Grav 1=66(LC 11), 3=65(LC 11)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph (3-second gust) Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=30ft; Cat. II; Exp B; enclosed; C-C
Exterior(2); cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33
2) TCLL: ASCE 7-10; Pf=20.0 psf (flat roof snow); Category II; Exp B; Fully Exp.; Ct= 1
3) Unbalanced snow loads have been considered for this design.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
7) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
16023 Swingley Ridge Rd
Chesterfield, MO 63017
Design valid for use only with MiTekfi connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Componentavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.Safety Information
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
May 12,2016
edge of truss.from outside"16/1-0PRODUCT CODE APPROVALSJOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGLATERAL BRACING LOCATIONIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.Min size shown is for crushing only.Indicated by symbol shown and/orby text in the bracing section of theoutput. Use T or I bracingif indicated.The first dimension is the plate width measured perpendicular to slots. Second dimension isthe length parallel to slots.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- Center plate on joint unless x, yoffsets are indicated.Dimensions are in ft-in-sixteenths.Apply plates to both sides of trussand fully embed teeth.1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering System1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI.2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered.3. Never exceed the design loading shown and never stack materials on inadequately braced trusses.4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties.5. Cut members to bear tightly against each other.6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1.7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1.8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication.9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber.10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection.11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements.12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified.13. Top chords must be sheathed or purlins provided at spacing indicated on design.14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted.15. Connections not shown are the responsibility of others.16. Do not cut or alter truss member or plate without prior approval of an engineer.17. Install and load vertically unless indicated otherwise.18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use.19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient.20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.Failure to Follow Could Cause PropertyDamage or Personal InjuryGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:6-4-8dimensions shown in ft-in-sixteenths (Drawings not to scale)' 2012 MiTekfi All Rights ReservedMiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015WEBSedge of truss.from outside"16/1-0ICC-ES Reports:ESR-1311, ESR-1352, ESR1988ER-3907, ESR-2362, ESR-1397, ESR-3282JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISEAROUND THE TRUSS STARTING AT THE JOINT FARTHEST TOTHE LEFT.CHORDS AND WEBS ARE IDENTIFIED BY END JOINTNUMBERS/LETTERS.W
4
-
6
W3-6W3-
7
W2-7W1-7C1-8
C5-6C6-7C7-8C4-5 C3-4C2-3C1-2TOP CHORD
TOP CHORD
87654321BOTTOM CHORDSTOP CHORDSBEARINGIndicates location where bearings(supports) occur. Icons vary butreaction section indicates jointnumber where bearings occur.4 x 4PLATE SIZEThis symbol indicates the required direction of slots inconnector plates."16/1For 4 x 2 orientation, locateplates 0- 1"4/3PLATE LOCATION AND ORIENTATIONSymbolsNumbering SystemGeneral Safety Notes*Plate location details available in MiTek 20/20software or upon request.Industry Standards:ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.DSB-89: Design Standard for Bracing.BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses.6-4-8dimensions shown in ft-in-sixteenthsWEBSTrusses are designed for wind loads in the plane of the truss unless otherwise shown.Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others.