HomeMy WebLinkAboutA004 -LIFE SAFETY PLAN> >> > M H KCRCR M H H HWAP 442 2 D DD D D D D OC OC2 2 VV V V VVV4 44 4 22 > >> >>> >> > > > >> > > >> >> > >> > > >> > >> EXISTING BUILDING AREA FIRE EXTINGUISHER LOCATIONS (SEE SHEET A100) EXISTING BUILDING OF RENOVATION EXT E EXISTING BUILDING EXIT EXT A BUILDING ADDITION EXIT FEC 1 HOUR SMOKE BARRIER 2 HOUR SMOKE BARRIER/FIRE BARRIER 2 HOUR FIRE BARRIER PATH OF EGRESS SMOKE RESISTANT CORRIDOR 1 HOUR CORRIDOR 2 HOUR CORRIDOR SMOKE RESISTANT SHAFT 1 HOUR SHAFT 2 HOUR SHAFT SMOKE RESISTANT HAZAROUS ROOM 2 HOUR EXIT ENCLOSURE B.6 B.9 D.3 4.14122.2 2.4 2.6 2.8 3 D D.5 E E.5 F G F.9 C C.1 D.4 G.1 B.95 B.7 .9 WAITING 001RECEPTION 003 MD NURSE 004 W&M 005 WORK ALCOVE 012 EXAM 4 011 PATIENT RR 006 STORAGE 010 EXAM 3 009 EXAM 2 008 EXAM 1 007 OFFICE 002 L1 L1 L1 L2 L2 L3 EXT E EXT E B.6 B.9 D.3 44.1 2 2.2 2.4 2.6 1 F G F.9 G.1 .9 D.5 E E.5 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 LIFE SAFETY PLAN 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290LIFE SAFETY PLAN LEGEND LIFE SAFETY PLAN NOTES L1 PATH OF EGRESS. L2 EXISTING EXIT LOCATION L3 NEW FIRE EXTINGUISHER LOCATION APPLICABLE CODES:2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE) 2010 INDIANA ENERGY CONSERVATION CODE (675-ISE 19-4) 2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE) 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH 2012 AMENDMENTS) 2009 INDIANA ELECTRICAL CODE (2008 NFPA 70) 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE) 2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE) PROJECT LOCATION: OCCUPANCY: SQUARE FOOTAGE: HEIGHT: CONSTRUCTION TYPE: WIDTH OF EXITS: FIRE SUPPRESSION SYSTEM: FIRE RESISTIVE CORRIDORS: SMOKE RESISTIVE CORRIDORS: HAZARDOUS ROOMS: EXIT ACCESS TRAVEL DISTANCE: OCCUPANT LOAD: CODE REVIEW SUMMARY PLUMBING COUNT: ALARMS / FIRE DETECTION: ACCESSIBILITY:PER BUILDING OCCUPANCY / ANSI REQUIREMENTS 10300 N. Illinois St, Suite 1200 Indianapolis, IN 46290 TYPE B OCCUPANCY 1631 SF EXISTING 1631 SF REMODELED BUILDING IS 2 STORIES TYPE II-B NOT REQUIRED PROJECT AREA: FULL SPRINKLER SUPPRESSION SYSTEM EXISTING BUILDING: FULLSPRINKLER SUPPRESSION SYSTEM NOT REQUIRED CONSTRUCTED AS SMOKE RESISTANT ASSEMBLIES: CLEAN ROOM, SOILED UTILITY ROOM, EQUIPMENT STORAGE EXIT ACCESS TRAVEL DISTANCE: NOT TO EXCEED 300 FEET DEAD END EXIT ACCESS: NOT TO EXCEED 50 (OR 20 IN I OCC.) FEET 100 SF PER OCCUPANT REQUIRED. 1631 SQUARE FEET 17 OCCUPANTS 1 OCCUPANTS 1 REQUIRED PER 25 OCCUPANTS; 1 REQUIRED 1 REQUIRED PER 40 OCCUPANTS; 1 REQUIRED AUTOMATIC FIRE DETECTION IS/NOT REQUIRED ALARM SYSTEM PER SECTION 907.2.6.2 EXIT DOOR WIDTH PROVIDED AT THE RATE OF 0.15 INCHES PER OCCUPANT. (SEC. 1005.2.3) NORTH 1/8" = 1'-0"A004 LEVEL 1 - LIFE SAFETY PLAN - GI CLINIC1 NORTH KEY PLAN - NOT TO SCALE AREA OF WORK # Revision Description Date Issued 06/08/21