HomeMy WebLinkAboutA120 -REFLECTED CEILING PLANRECESSED LIGHT
NEW 2' X 4' RECESSED FIXTURE
NEW CEILING GRID
EXISTING CEILING GRID
WALL MOUNTED EXIT SIGN
CEILING MOUNTED EXIT SIGN
HVAC SUPPLY DIFFUSER
HVAC RETURN GRILLE
SMOKE DETECTORSD
EXISTING 2' X 4' RECESSED FIXTURECEILING TYPE
MATERIAL/DETAIL VARIATION
CEILING HEIGHT
CLG1 1' -0"
1 2
E.5
F
G
F.9
G.1
.9
ETRX2 ETRX
ETRX2
ETRX
M.E. CLG1
M.E.CLG1
M.E.CLG1 ETRX2
M.E.CLG1
ETRX2
ETRX2
ETRX2
ETRCLG1
RECEPTION
003
WAITING
001
MD NURSE
004
W&M
005
PATIENT RR
006 EXAM 4
011
WORK ALCOVE
012
EXAM 3
009
EXAM 2
008
EXAM 1
007
STORAGE
010
C1
X 8' -0"
C2
C3
www.studio3design.net
Phone: (317) 595.1000
8604 Allisonville Road, Suite 330
Indianapolis, IN 46250
A
B
C
D
E
1 2 3 4 5 6 7
A
B
C
D
E
THESE DRAWINGS ARE THE PROPERTY
OF STUDIO 3 DESIGN, INC. ALL RIGHTS
RESERVED
PROJECT NUMBER:
DATE:
CERTIFICATION:
SHEET DESCRIPTION:
SHEET NUMBER:
REVISION SCHEDULE:
1 2 3 4 5 6 7
21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021
REFLECTED
CEILING PLAN 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290GENERAL REFLECTED CEILING NOTES
A. DIMENSIONS ON REFLECTED CEILING PLAN ARE TAKEN FINISHED FACE TO FINISHED FACE.
B. SEE ELECTRICAL FOR SWITCHING OPERATION AND LOCATION.
C. COORDINATE ALL DUCTWORK AND LIGHTING WITH STRUCTURE, BULKHEAD AND CEILING TO DECK
CLEARANCES PRIOR TO STARTING WORK.
D. LIGHTS AND DIFFUSERS SHOWN FOR LOCATION. SEE ELECTRICAL AND HVAC PLANS FOR FIXTURE
COUNTS AND TYPES.
E. UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID EACH DIRECTION IN ROOM. MAINTAIN
MINIMUM EDGE TILE AT 6".
F. UNLESS OTHERWISE NOTED/SHOWN - PLASTER / GYP. BOARD BULKHEAD SIDES AND UNDERNEATH
TO BE PAINTED, PAINT TO BE GENERAL CEILING WHITE.
MEP DESIGN BUILD NOTES
A. GENERAL CONTRACTOR SHALL COORDINATE ALL TRADES, INCLUDING DESIGN BUILD CONTRACTORS,
AND ENSURE MEP SUBCONTRACTORS MEET WITH OWNER, DESIGNER, AND OTHERS TO ENGINEER
SYSTEMS TO MEET OWNER'S NEEDS.
B. GENERAL CONTRACTOR SHALL PROVIDE MEP DESIGN DOCUMENTS AND DRAWINGS TO OWNER AND
DESIGNER FOR REVIEW, COMMENT AND APPROVAL.
C. GENERAL CONTRACTOR SHALL ENSURE MEP DESIGN BUILD DOCUMENTS ARE SUBMITTED TO THE
STATE AND LOCAL CODE OFFICIAL AS REQUIRED BY STATE STATUE/LAW.
D. HVAC SYSTEMS TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT.
E. ELECTRICAL POWER & DATA SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPERATE
CONTRACT.
F. LIGHTING SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT.
G. PLUMBING SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT.
H. G.C. IS RESPONSIBLE TO PROVIDE ALL COORDINATION OF DESIGN AND CONSTRUCTION DISCIPLINES.
I. G.C. IS RESPONSIBLE TO PROVIDE ALL DESIGN, MATERIAL AND LABOR UNDER SEPERATE VENDOR
CONTRACT AS REQUIRED FOR A COMPLETE INSTALLATION IN COMPLIANCE WITH ALL STATE, LOCAL
AND HEALTH DEPARTMENT BUILDING CODES.
J. ARCHITECTURAL DOCUMENTS PROVIDE SUGGESTED LIGHTING LOCATIONS AND FIXTURE TYPES. ALL
CIRCUITING TO BE VENDOR ENGINEERED BY CONTRACTOR.
K. CONTRACTOR SHALL DESIGN AND PROVIDE EMERGENCY LIGHTING AS REQUIRED BY STATE AND
LOCAL CODE.
L. CONTRACTOR SHALL DESIGN AND INSTALL SALVAGED BUILDING STANDARD FIXTURES AT LOCATIONS
INDICATED TO MATCH BUILDING STANDARD FIXTURES AND ONLY PROVIDE NEW FIXTURES WHERE
REQUIRED.
M. CONTRACTOR SHALL PROVIDE INDEPENDANT SWITCHING FOR EACH AREA AND AT A LOGICAL AREA
ENTRY. IN CORRIDORS AND LARGE PUBLIC AREAS, PROVIDE MULTIPLE SWITCH LOCATIONS.
N. PROVIDE DIMMABLE SWITCHES AT ALL FIXTURES THAT ARE DIMMABLE.
O. CONTRACTOR SHALL DESIGN AND PROVIDE EXIT LIGHTING TO MATCH BUILDING STANDARD AND TO
MEET STATE AND LOCAL CODES.
REFLECTED CEILING PLAN
LEGEND
REFLECTED CEILING PLAN NOTES
C1 PROVIDE NEW LAYER OF GYP BOARD AT AREA OF DEMOLITION TO CREATE NEW BULKHEAD.
C2 INFILL BULKHEAD TO WALL. HEIGHT, SIZE AND FINISH TO MATCH EXISTING.
C3 PATCH AND REPAIR CEILING AS REQUIRED TO PROVIDE NEW WALL CONSTRUCTION ABOVE EXISTING
TO REMAIN 6'-0"AFF PARTIAL HEIGHT WALL.
CEILING TYPE SCHEDULE
TAG MANUFACTURER STYLE # COLOR SIZE COMMENTS
CLG1 ARMSTRONG .75 NRC MINERAL FIBERBOARD, 35
CAC, ULTIMA, STRAIGHT EDGE
1910HRC WHITE 2'X2' 15/16" GRID
X EXISTING TO REMAIN GRID AND
TILE
X2 EXISTING TO REMAIN GRID WITH
NEW TILE TO MATCH CLG1
NORTH
1/8" = 1'-0"A120
LEVEL 1 - NEW REFLECTED
CEILING PLAN - GI CLINIC1
NORTH
KEY PLAN - NOT TO SCALE
AREA
OF
WORK
# Revision Description
Date
Issued
06/08/21