Loading...
HomeMy WebLinkAboutE001 - Electrical Symbols and General NotesA or AMP AC A/C ACP ACU ADD ADJ AF AFC AFF AFG AHU AIC AL AM AMB APPROX. ARCH ATS AUTO AVG BC BKR BHP BL BLDG BR BTM C ºC CAB CB or C/B C/C CCTV CKT CL CLG COL COMM COMP CONC CONST CONT CONTR CR CT CU DB DC DEPT DF DIST DM DO DRS DWG EC EF ELEC ELEV ELV EMER ENCL EP EQUIP EWC EX EXH EXP EXT ºF FA FAAP FACP FC FCU FFC FFS FHC FIN FIXT FL FLUOR FLEX-CONN FPC FSS FTG FVR FV FVNR G or GND GALV GC GEN GFCI GFI GFP HGT HH HID HO HOA HORZ HP HPS HTR HV AMPERE ALTERNATING CURRENT AIR CONDITIONING ACCESS PANEL AIR CONDITIONING UNIT ADDITION ADJUSTABLE AMPERE FRAME ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALUMINUM AMMETER AMBIENT APPROXIMATELY ARCHITECT AUTOMATIC TRANSFER SWITCH AUTOMATIC AVERGE BARE COPPER BREAKER BRAKE HORSEPOWER BUILDING LINE BUILDING BRANCH BOTTOM CONDUIT DEGREES CELSIUS CABINET CIRCUIT BREAKER CENTER TO CENTER CLOSED CIRCUIT TELEVISION CIRCUIT CENTER LINE CEILING COLUMN COMMUNICATION COMPRESSOR CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CRITICAL CURRENT TRANSFORMER COPPER DIRECT BURIAL DIRECT CURRENT DEPARTMENT DRINKING FOUNTAIN DISTRIBUTION DEMAND METER DRAWOUT DOCTORS DRAWING ELECTRICAL CONTRACTOR EXHAUST FAN ELECTRIC ELEVATOR ELEVATION EMERGENCY ENCLOSURE ELECTRIC PNEUMATIC EQUIPMENT ELECTRIC WATER COOLER EXPLOSIONPROOF EXHAUST EXPANSION EXTERIOR DEGREES FAHRENHEIT FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FLAT CABLE FAN COIL UNIT FOOD FACILITY CONTRACTOR FOOD FACILITY SUPPLIER FIRE HOSE CABINET FINISH FIXTURE FLOOR FLUORESCENT FLEXIBLE CONNECTION FIRE PROTECTION CONTRACTOR FUSED SAFETY SWITCH FOOTING FILMVIEWER FULL VOLTAGE FULL VOLTAGE NON REVERSING GROUND GALVANIZED GENERAL CONTRACTOR GENERATOR GROUND FAULT CKT. INTERRUPTER GROUND FAULT INTERRUPTER GROUND FAULT PROTECTION HEIGHT HANDHOLE HIGH INTENSITY DISCHARGE HAND OPERATED HAND-OFF-AUTOMATIC HORIZONTAL HORSEPOWER HIGH PRESSURE SODIUM HEATER HIGH VOLTAGE HZ IC ID INCAN INCL ISG JB JT KEC KT KVA KVAR KW LAB LB LF LOC LS LT LTG LV MATV MAX MC MCB MCC MDP MECH MH MIN MISC MLO MTD MTG HT MU OD OFCI OFOI OPNG OPP OR P PB PBOX PE PF PH or Ø PV PNL PL PREFAB PRES PT PTS PW PWR RACU RAD RECEPT REF or REFR REINF RGIP RM RPM SA SC SG SHT SIG SN SPEC SQ SS SSSS STD STN STR SUSP SW SWBD SWGR TCC TELE TEMP TMH TV TYP UC U/C UH UV V VAC VB VC VEL VFD VM VOL VP VSD/VFC W/ W/O WTR WP WT XFMR Z HERTZ INTERCOMMUNICATION INSIDE DIAMETER INCANDESCENT INCLUDE ISOLATED GROUND SURGE GUARD JUNCTION BOX JOINT KITCHEN EQUIPMENT CONTRACTOR KITCHENETTE KILOVOLT AMPERE KILOVOLT AMPERE REACTIVE KILOWATT LABORATORY POUND LINEAR FEET LOCATION LIFE SAFETY LIGHT LIGHTING LOW VOLTAGE MASTER ANTENNA TELEVISION MAXIMUM MECHANICAL CONTRACTOR MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MECHANICAL MANHOLE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOUNTING HEIGHT MEDICINE UNIT OUTSIDE DIAMETER OWNER FURNISHED-CONTRACTOR INSTALLED OWNER FURNISHED-OWNER INSTALLED OPENING OPPOSITE OPERATING ROOM POLE PUSHBUTTON PULL BOX PNEUMATIC ELECTRIC CONVERTER POWER FACTOR PHASE POST INDICATOR VALVE PANELBOARD PILOT LIGHT PREFABRICATED PRESSURE PNEUMATIC TUBE PNEUMATIC TUBE STATION PART WINDING POWER ROOM AIR CONDITIONING UNIT RADIATION RECEPTACLE REFRIGERATOR REINFORCED REMOTE GROUND INDICATING PANEL ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SHORT CIRCUIT SURGE GUARD PROTECTION SHEET SIGNAL SOLID NEUTRAL SPECIFICATIONS SQUARE SAFETY SWITCH SOLID STATE SOFT START STANDARD STATION STRUCTURAL SUSPENDED SWITCH SWITCHBOARD SWITCHGEAR TEMPERATURE CONTROL CONTRACTOR TELECOMMUNICATION TEMPERATURE TOP OF MANHOLE TELEVISION TYPICAL UNDER CARPET UNDER CABINET or UNDER COUNTER UNIT HEATER UNIT VENTILATOR VOLT VACUUM VACUUM BREAKER VACUUM CLEANING VELOCITY VARIABLE FREQUENCY DRIVE VOLTMETER VOLUME VAPORPROOF VARIABLE SPEED DRIVE/CONTROLLER WITH WITHOUT WATER WEATHERPROOF WEIGHT TRANSFORMER IMPEDANCE ELECTRICAL ABBREVIATIONS M FIRE ALARM SYSTEM SYMBOL DESCRIPTION MANUAL SENDING STATION PIV POST INDICATOR VALVE SD CEILING SMOKE DETECTOR TS SPRINKLER SYSTEM TAMPER SWITCH FS SPRINKLER SYSTEM FLOW SWITCH SD WALL SMOKE DETECTOR SD WALL SMOKE DETECTOR WITH SOUNDER BASE SD CEILING SMOKE DETECTOR WITH SOUNDER BASE DD AUTOMATIC DUCT DETECTOR ("X" DENOTES AS FOLLOWS) RT REMOTE DETECTOR TEST STATION RI REMOTE DETECTOR INDICATOR STATION AR FIRE ALARM ADDRESSABLE RELAY X NONE -PHOTOELECTRIC TYPE S - SUPPLY R -RETURN DR DOOR RELEASE DU DOOR UNLOCK J FIREMANS JACK HD HEAT DETECTOR FD FLAME DETECTOR BD BEAM DETECTOR H WALL HORN ONLY H WALL HORN STROBE CEILING HORN ONLY CEILING HORN STROBE H H S WALL SPEAKER ONLY S WALL SPEAKER STROBE CEILING SPEAKER STROBES V WALL VISUAL ONLY CEILING VISUAL ONLYV FACP FIRE ALARM CONTROL PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT3 ST -20 AMP, 125VAC, SAFETY TYPE S -20 AMP, 125VAC, SURGE GUARD PROTECTION TYPE WP - 20 AMP, 125VAC, WEATHERPROOF TYPE HM - 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE IG -20 AMP, 125VAC, ISOLATED GROUND TYPE NONE -20 AMP, 125VAC ELECTRICAL RECEPTACLES DUPLEX RECEPTACLE -NORMAL POWER CIRCUIT DESCRIPTIONSYMBOL DUPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT DUPLEX GFCI RECEPTACLE -NORMAL POWER CIRCUIT DUPLEX GFCI RECEPTACLE -EMERGENCY POWER CIRCUIT QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT QUADRAPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT QUADRAPLEX GFCI RECEPTACLE -NORMAL POWER CIRCUIT QUADRAPLEX GFCI RECEPTACLE -EMERGENCY POWER CIRCUIT SIMPLEX RECEPTACLE -NORMAL POWER CIRCUIT SIMPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT SPECIAL RECEPTACLE -NORMAL POWER CIRCUIT SPECIAL RECEPTACLE -EMERGENCY POWER CIRCUIT DUPLEX RECEPTACLE -TOP SWITCHED "X" DENOTES AS FOLLOWS: CEILING DUPLEX RECEPTACLE -NORMAL POWER CIRCUIT CEILING DUPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT CEILING QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT CEILING QUADRAPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT FLOOR BOX DUPLEX RECEPTACLE -NORMAL POWER CIRCUIT FLOOR BOX DUPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT FLOOR BOX QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT FLOOR BOX QUADRAPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT FLOOR BOX POWER AND TELECOM FLOOR BOX BLANK MULTI-OUTLET ASSEMBLY (POWER AND/OR TELECOM) ELECTRICAL SWITCHES DESCRIPTIONSYMBOL TOGGLE SWITCH - 20 AMP, 120/277VAC TOGGLE SWITCH -3 WAY 4 TOGGLE SWITCH -4 WAY K TOGGLE SWITCH - KEY OPERATED T TOGGLE SWITCH - HORSE POWER RATED MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION P TOGGLE SWITCH -PILOT LIGHT D DIMMER SWITCH -20 AMP, 120/277VAC D DIMMER SWITCH -3 WAY3 4D DIMMER SWITCH -4 WAY OC1 WALL OCCUPANCY SENSOR - 1 BUTTON CONTROL OC2 WALL OCCUPANCY SENSOR - 2 BUTTON CONTROL OC3 WALL OCCUPANCY SENSOR -DUAL RELAY FOR EXHAUST FAN CONTROL OC CEILING OCCUPANCY SENSOR VS1 WALL VACANCY SENSOR -1 BUTTON CONTROL VS2 WALL VACANCY SENSOR -2 BUTTON CONTROL LC LOW VOLTAGE LIGHTING CONTROLLER T 0 -3 HOUR TIMER SWITCH -20 AMP, 120/277VAC INFORMATION SYSTEMS DESCRIPTIONSYMBOL VOICE AND DATA ONLY OUTLET WAP -WIRELESS ACCESS POINT FLOOR BOX -VOICE AND DATA CEILING -VOICE AND DATA TELECOMMUNICATIONS EQUIPMENT RACK X R -ROUGH-IN ONLY # -QUANTITY OF JACK(S) AND CABLE(S) "X" DENOTES AS FOLLOWS: LIGHTING DESCRIPTION NO SHADING INDICATES NORMAL POWER SYMBOL 24" x 24" LIGHTING FIXTURE 12" x 48" LIGHTING FIXTURE HALF SHADED INDICATES LIFE SAFETY POWER FULL SHADED INDICATES EMERGENCY POWER 12" x 96" LIGHTING FIXTURE 6" x 96" LIGHTING FIXTURE 6" x 48" LIGHTING FIXTURE 6" x 36" LIGHTING FIXTURE 6" x 24" LIGHTING FIXTURE 8" DOWNLIGHT 6" DOWNLIGHT 4" DOWNLIGHT WALL MOUNTED LIGHT CEILING EXIT LIGHT (DUAL FACED) CEILING EXIT LIGHT (SINGLE FACE) WALL EXIT LIGHT EXIT LIGHT DIRECTIONAL ARROWS WALL EMERGENCY BATTERY LIGHT WALL EXIT WITH EMERGENCY LIGHTS CEILING EMERGENCY BATTERY LIGHT WALL EXIT WITH INTERIOR AND EXTERIOR EMERGENCY LIGHTS EXTERIOR POLE LIGHT (ONE HEAD) EXTERIOR POLE LIGHT (TWO HEADS) EXTERIOR POLE LIGHT (THREE HEADS) EXTERIOR POLE LIGHT (FOUR HEADS) EXTERIOR POLE LIGHT (TOP MOUNT) EXTERIOR BOLLARD NEUTRAL GROUND RACEWAY SYSTEM DESCRIPTION PHASE CONDUCTORS SYMBOL LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK LINE SYMBOLS HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED J JUNCTION OR PULL BOX PUSHBUTTON OR PUSH PLATE PAD MOUNTED TRANSFORMER BRANCH PANELBOARD -SURFACE MOUNT COMBINATION MOTOR CONTROLLER / DISCONNECT DISCONNECT SWITCH - NON-FUSED MOTOR CONTROLLER DISCONNECT SWITCH - FUSED MOTOR ("X" DENOTES HORSEPOWER) GROUND CONNECTION ELECTRIC THERMOSTATT DESCRIPTION MOLDED CASE CIRCUIT BREAKER ELECTRICAL EQUIPMENT SYMBOL GROUND POINT GROUND ROD X PC PHOTO CELL SUSPENDED TRANSFORMER DISTRIBUTION PANELBOARD BRANCH PANELBOARD -RECESSED MOUNT AUTOMATIC TRANSFER SWITCHN E L TELECOM TERMINAL BOARD GROUND BAR GENERATOR TV AV TV SYSTEM OUTLET AUDIO/VISUAL CONTROLLER CLOCK SYSTEM OUTLETC M M MICROPHONE INPUT RECEPTACLE -WALL MOUNTED SPEAKER -WALL MOUNTED SPEAKER -CEILING MOUNTED VOLUME CONTROL MICROPHONE INPUT RECEPTACLE -CEILING MOUNTED S S V M D S E P CB CP L Z W R A N NC IC X MTV CCTV DR ES IC MI ML CR MD DC PB K BS DS SM SS DE PC PC P IR RF CL WL 2X NURSE ASSIST NURSE ASSIST/CODE BLUE DOOR SECURITY SYSTEM SYMBOL DESCRIPTION DOOR BUZZER SECURITY DOOR ALARM MAGNETIC LOCK CCTV MONITOR OUTLET ELECTRIC DOOR OPENER ELECTRIC DOOR STRIKE INTERCOM UNIT FLUSH MTD. MASTER INTERCOM AND DIRECTORY UNIT MOTION DETECTOR CCTV COAXIAL CABLE OUTLET AND POWER OUTLET SECURITY CARD READER SECURITY CONTROL PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEYPAD BIOSCAN ACCESS PAD CAMERA DUTY STATION DESCRIPTION MASTER STATION STAFF STATION STAFF LOCATOR STATION CODE BLUE STATION SYMBOL ROOM READY INDICATOR REMOTE ANNUNCIATOR NURSE STATION INPUT JACK BED CONTROL CABLE/INTERCONNECT JACK NURSE CALL SYSTEM PATIENT STATION -SINGLE OUTLET EMERGENCY/BATH STATION ZONE LIGHT WALL MOUNTED DOME LIGHT CODE PINK STATION NURSE AUXILIARY JACK TELEMETRY ANTENNA LOCATION CEILING MOUNTED DOME LIGHT SECURITY DUTY STATION SECURITY STAFF STATION SECURITY MONITOR SECURITY DOOR EGRESS PULL CORD PULL CORD WITH ALARMA PATIENT STATION -SINGLE OUTLET WITH CODE / STAFF ASSIST BUTTONE TRACKING SENSOR (IR) TRACKING SENSOR (RF) DOUBLE NURSE AUXILIARY JACK NAC FIRE ALARM NOTIFICATION APPLIANCE CONTROL PANEL WAP X X RECEPTACLE ABOVE COUNTERTOP AT +2" ABOVE BACKSPLASH TO BOTTOM OF DEVICE. COORDINATE WITH CASEWORK TO BE INSTALLED. RECEPTACLE INSTALLED BELOW COUNTERTOP AT +18" A.F.F. COORDINATE WITH CASEWORK TO BE INSTALLED. X RECEPTACLE LEGEND DESCRIPTIONABBREVIATION ABBREVIATION DESCRIPTION FXX FEEDER SIZE. (REFER TO FEEDER SCHEDULE FOR ADDITIONAL INFORMATION (APPLY TO ALL ELECTRICAL SHEETS) 1. PROVIDE SUPPORT WIRES FOR ALL LIGHT FIXTURES. 2. COORDINATE INSTALLATION OF LIGHT FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN, HVAC EQUIPMENT, DUCTWORK, PIPING AND SUPPORTS. 3. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS AT THE PROJECT SITE BEFORE SUBMITTING COST PROPOSAL. 4. ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS TO FAMILIARIZE HIMSELF WITH EXTENT OF REMODELING / ALTERATION WORK. 5. ALL WORK SHALL CONFORM TO OR EXCEED THE MINIMUM REQUIREMENTS OF THE CURRENT ANSI / NFPA 70 WITH STATE AMENDMENTS, ENERGY CODE, ANSI / IEEE C2 AND ALL FEDERAL, STATE, LOCAL AND MUNICIPAL CODES AND ORDINANCES. THE ELECTRICAL SUBCONTRACTOR SHALL COMPLY WITH THE DIRECTIONS OF ALL AUTHORITIES HAVING JURISDICTION. 6. INSTALL WORK USING PROCEDURES DEFINES IN NECA STANDARDS OF INSTALLATION. ALL WORK SHALL PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. 7. REFER TO THE ARCHITECTURAL DRAWINGS FOR CEILING WORK BY THE GENERAL CONTRACTOR. COORDINATE ALL ELECTRICAL WORK. 8. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE ALL FLOOR, WALL, AND CEILING PENETRATIONS TO COMPLETE HIS / HER WORK. PROVIDE PROPER FIRE SAFEING FOR ALL PENETRATIONS MADE. PROVIDE APPROPRIATE SEALANT (I.E. FIRESAFEING) TO MAINTAIN CONSTRUCTION INTEGRITY FOR ANY PENETRATIONS THROUGH FLOORS, STRUCTURAL CEILING, AND FIRE WALLS. 9. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES TO ENSURE EFFECTIVE AND EFFICIENT OVERALL INSTALLATION. 10. COORDINATE ALL ELECTRICAL SYSTEM DOWNTIME WITH THE OWNER AND OTHER TRADES. IT IS MANDATORY THAT THE EXISTING BUILDING REMAIN IN CONTINUOUS AND NON-INTERRUPTED OPERATION DURING THE REMODELING / ALTERING OF THE EXISTING BUILDING. THE SPECIFIC AREA(S) BEING REMODELED / ALTERED AT ANY TIME ARE OBVIOUSLY EXCLUSIVE OF THE STATEMENT. SERVICES TO EXISTING BUILDING SHALL BE KEPT ON CONTINUOUS OPERATION INCLUDING POWER, FIRE ALARM, LIGHTING, TELEPHONE, ETC. DOWNTIME OF THESE SYSTEMS SHALL BE MINIMIZED. WEEKEND AND AFTER HOURS WORK MAY BE REQUIRED TO PREVENT OR MINIMIZE INTERFERENCE WITH OWNERS OPERATION. 11. CONTRACTOR SHALL WORK CLOSELY WITH THE OWNER TO IDENTIFY ALL SYSTEMS WIRING, DEVICES, ETC. THAT MUST REMAIN OPERATIONAL DURING CONSTRUCTION. COORDINATE ALL DEMOLITION WITH THE OWNER PRIOR TO ANY DEMOLITION WORK. 12. THE LOCATION OF NEW RECEPTACLES, PHONE / DATA JACKS, AND ROOM EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. FINAL LOCATIONS WILL BE DETERMINED WITH THE ARCHITECT DURING THE CONSTRUCTION PHASE. 13. IN REMODELED / ALTERED AREA ANY FEEDERS, CONDUITS, BRANCH CIRCUITS, SIGNAL AND TELEPHONE CIRCUITS, ETC. PASSING THROUGHOUT THE REMODELED / ALTERED AREAS TO SERVE (OR BE SERVED FROM EXISTING ADJACENT, REMOTE, OR SURROUNDING THAT ARE TO REMAIN) SHALL BE RETAINED AND KEPT OPERATIONS AND SHALL BE REROUTED IN ALL CASES WHERE THEY INTERFERE WITH ANY NEW WORK OR USAGE TO BE ACCOMPLISHED IN THE REMODELED / ALTERED AREA. 14. WHERE DEVICES ARE OMITTED FROM PRESENT BRANCH CIRCUITS, THE REMAINING DEVICE SHALL BE REWIRED. IF NEEDED AND AS REQUIRED, TO REMAIN IN THEIR RESPECTIVE CIRCUITS AND IN OPERATING CONDITION. 15. ALL NEW EQUIPMENT SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING. 16. PHYSICAL SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. COORDINATE ELECTRICAL WORK FOR THIS EQUIPMENT WITH THE OTHER TRADES. 17. ALL BRANCH CIRCUITS SHALL UTILIZE SEPARATE INDEPENDENT NEUTRAL CONDUCTORS. DO NOT COMBINE NEUTRAL CONDUCTORS. 18. ALL FEEDER NEUTRAL / GROUNDED CONDUCTORS SHALL BE CONSIDERED CURRENT CARRYING. DERATE MULTIPLE CONDUCTORS IN A RACEWAY ACCORDINGLY WITH NEC TABLES. 19. INSTALL ALL CONDUITS, RACEWAYS, AND CABLE TRAY FOR MAXIMUM HEAD CLEARANCE IN MECHANICAL AREAS. 20. ALL DEVICES SHOWN ON THESE DRAWINGS TO BE REMOVED SHALL BE REMOVED COMPLETE INCLUDING ALL ASSOCIATED CONDUIT AND WIRING BACK TO SOURCE UNLESS OTHERWISE NOTED. ALL CIRCUIT BREAKERS OR EQUIPMENT MADE SPARE BY THE DEMOLITION SHALL BE TURNED OFF AND MARKED SPARE. IT IS THE INTENT THAT ALL EXISTING ELECTRICAL DEVICES, CONDUIT, WIRING, ETC. IN THIS SPACE THAT ARE NOT REUSED AND ARE ABANDONED SHALL BE REMOVED COMPLETE. CONTRACTOR SHALL FIELD VERIFY EXACT REQUIREMENTS. NOT ALL DEVICES ARE SHOWN ON THIS DRAWING. 21. ALL DEVICES AND LIGHT FIXTURES SHOWN TO BE REMOVED FROM EXISTING BLOCK WALLS THAT ARE NOT REUSED SHALL HAVE BLANK COVERS INSTALLED. 22. ALL DEVICES SHOWN TO BE REMOVED FROM EXISTING WALLS THAT REMAIN SHALL HAVE DEVICES AND ASSOCIATED CONDUIT REMOVED AND WALL SHALL BE PATCHED. 23. REFER TO MECHANICAL DEMOLITION PLANS FOR ALL EQUIPMENT THAT IS TO BE REMOVED. REMOVE ALL ASSOCIATED CONDUIT AND WIRING TO THESE DEVICES. 24. TELEVISION SYSTEM: REMOVE ALL TELEVISION SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER TELEVISION WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 25. TELEPHONE / DATA SYSTEM: REMOVE ALL TELEPHONE / DATA SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER TELEPHONE / DATA WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 26. CCTV SYSTEM: REMOVE ALL CCTV SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER CCTV WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 27. NURSE CALL SYSTEM: REMOVE ALL NURSE CALL SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER NURSE CALL WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 28. FIRE ALARM SYSTEM: REMOVE ALL FIRE ALARM SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER FIRE ALARM WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 29. ALL LIGHT FIXTURES SHOWN WITH EMERGENCY BATTERY BALLASTS SHALL HAVE UNSWITCHED "HOT" WIRE INSTALLED TO BALLAST. 30. NEW DEVICES SHOWN TO BE INSTALLED ON EXISTING DRYWALL WALLS SHALL BE INSTALLED FLUSH IN WALL WITH CONDUIT AND WIRING CONCEALED. CUT AND PATCH EXISTING WALLS AS REQUIRED. 31. NEW DEVICES SHOWN TO BE INSTALLED ON EXISTING BLOCK WALLS SHALL BE INSTALLED SURFACE MOUNTED AND IN SURFACE MOUNTED WIREMOLD PAINTED TO MATCH WALL. 32. WIRING SHALL BE INSTALLED ABOVE ACCESSIBLE CEILINGS AND IN DRYWALL WALLS WHERE POSSIBLE. 33. WIRING THAT IS TO BE INSTALLED IN AREAS WHERE THERE ARE NO CEILINGS SHALL BE INSTALLED EXPOSED. CABLING SHALL BE INSTALLED NEATLY AND AT RIGHT ANGLES TO STRUCTURE. WIRING SHALL BE INDEPENDENTLY SUPPORTED AS REQUIRED. WIRING SHALL NOT LAY OVER OTHER TRADES. 34. NEW DEVICES SHALL MATCH EXISTING DEVICES AND COVERPLATES. 35. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE COVERED. MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITY AS REQUIRED. CEILING AND WALL MOUNTED SENSORS SHALL BE DUAL TECHNOLOGY TYPE. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY TO CONTROL LIGHT FIXTURES IN ROOM / AREA. SENSORS SHALL OPERATE IN "VACANCY" MODE -MANUAL ON / AUTO OFF. TYPE OC SQUARE - INDICATES A WALL MOUNTED SINGLE CIRCUIT SENSOR WITH 1 SWITCH, TYPE ROUND OC INDICATES A CEILING MOUNTED SENSOR. PROVIDE A SET OF AUXILIARY CONTACTS ON ALL WALL AND CEILING MOUNTED OCCUPANCY SENSORS FOR SENSOR STATUS FOR TEMPERATURE CONTROL. 36. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN DEMOLITION, REMOVAL, CAPPING, STORING, ABANDONING, DISCONNECTION, RELOCATING AND RECONNECTION OF EXISTING ELECTRICAL EQUIPMENT AND MATERIAL. ALL CUTTING, PATCHING, REPAIRING, REPLACEMENT AND REFINISHING, SHALL MATCH THE EXISTING CONSTRUCTION AS NEARLY AS POSSIBLE. 37. ALL WIRING (POWER, LIGHTING) NOT REUSED FOR REMODELING AREAS SHALL BE COMPLETELY REMOVED BACK TO ASSOCIATED PANELS. 38. THE OWNER SHALL HAVE THE FIRST CHOICE TO ACCEPT EXISTING DEVICES BEING REMOVED. 39. REMOVE ALL ABANDONED CONDUITS, BOXES AND WIRING WITHIN PROJECT AREA. 40. FIRE ALARM SYSTEM SHALL BE MAINTAINED DURING PROJECT. 41. CEILING MOUNTED DEVICES TO REMAIN SHALL BE SUPPORTED FROM STRUCTURE DURING CONSTRUCTION AND REINSTALLED IN NEW CEILING. 42. ARRANGEMENTS SHALL BE MADE WITH OWNER REPRESENTATIVE TO COORDINATE FIRE ALARM SYSTEM OUTAGE. 43. CONTRACTOR SHALL PROTECT EXISTING CABLES DURING ALL PHASES OF CONSTRUCTION. 44. ALL DEVICES (EXIT SIGNS, FIRE ALARM, LIGHTING, ETC) THAT ARE TAKEN OUT OF SERVICE AND NOT REUSED SHALL BE RETURNED TO THE OWNER. 45. ALL RECEPTACLES SHALL BE HOSPITAL GRADE AND SAFETY / TAMPERPROOF TYPE. SCP GENERAL NOTES 24" x 48" LIGHTING FIXTURE 12" x 36" LIGHTING FIXTURE 12" x 24" LIGHTING FIXTURE 12" x 12" LIGHTING FIXTURE www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Electrical Symbols and General Notes E00110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21