HomeMy WebLinkAboutE101 - First Floor Electrical PlansM
H
CR
+4'WH HEE
VMM
EEEEWAP
TV WLWLWL WL WLWL
WLJJ
E
D
DD DD
D
D
OCOC
OC
OC
OC
OC OC
OC
OC
OC
OC
H HWAP42 2 2 2 VVV V
VVV4 44 4 2S
S
S
S
1 2
E.5
F
G
F.9
G.1
.9
NL
2 1
F
G
F.9
G.1
.9
2
TYP.
1
1
E.5
1 2
E.5
F
G
F.9
G.1
.9
X-RAY
VIEWER
X-RAY
VIEWER
21
F
G
F.9
G.1
.9
3
TYP.
1
TYP.
1
TYP.
1
TYP.
E.5
1 2
E
E.5
F
G
F.9
G.1
.9 21
F
G
F.9
G.1
.9
L1 4 L1 4
L1 4 L1 4
L1 4 L1 4 L1 4 L1 4
L2
4
L2
4
L2
4
L2
4
L2
5
L2
4
L2
4
L2
5
L2
4
L1
4
L1
4
L1
4
L1
4
L1
4
NL
NL
5
L2
4
E
E.5
NL
L3
L3
L3
L3
L3
L3
L3
4
L3
L3 L3
4
L3
4
L3
L3
4
4444
4
4
4
4
4
L3
WAITING
001
OFFICE
002
RECEPTION
003
MD NURSE
004
W&M
005
PATIENT RR
006
EXAM 4
011
EXAM 1
007
EXAM 2
008
EXAM 3
009
WORK ALCOVE
012
STORAGE
010
1 2
E.5
F
G
F.9
G.1
.9 21
F
G
F.9
G.1
.9
7TYP.
6
TYP.
8
TYP.29
E.5
OFFICE
002
RECEPTION
003
WAITING
001
MD NURSE
004
W&M
005
PATIENT RR
006
STORAGE
010
EXAM 4
011
WORK ALCOVE
012
EXAM 3
009
EXAM 2
008
EXAM 1
007
10
10
10
10
11
NORTH
www.studio3design.net
Phone: (317) 595.1000
8604 Allisonville Road, Suite 330
Indianapolis, IN 46250
A
B
C
D
E
1 2 3 4 5 6 7
A
B
C
D
E
THESE DRAWINGS ARE THE PROPERTY
OF STUDIO 3 DESIGN, INC. ALL RIGHTS
RESERVED
PROJECT NUMBER:
DATE:
CERTIFICATION:
SHEET DESCRIPTION:
SHEET NUMBER:
REVISION SCHEDULE:
1 2 3 4 5 6 7
21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IKEY PLAN -NOT TO SCALE
AREA OF WORK
April 9, 2021
First Floor
Electrical Plans
E10110300 N. ILLINOIS ST.INDIANAPOLIS, IN 462901/8" = 1'-0"1 First Floor Lighting Demolition Plan
1/8" = 1'-0"2 First Floor Power and Systems Demolition Plan
1/8" = 1'-0"3 First Floor Lighting Plan
1/8" = 1'-0"4 First Floor Power and Systems Plan
PLAN NOTES
1 EXISTING TO REMAIN.
2 DISCONNECT AND REMOVE ALL LIGHT FIXTURES AND ASSOCIATED DEVICES SHOWN AS DASHED. REMOVE BACK
TO SOURCE OR NEAREST JUNCTION BOX TO REMAIN.
3 DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES SHOWN AS DASHED, INCLUDING BUT NOT LIMITED TO
RECEPTACLES, FIRE ALARM DEVICES, NURSE CALL, DATA, ETC. REMOVE BACK TO SOURCE OR NEAREST
JUNCTION BOX TO REMAIN.
4 CONNECT NEW NORMAL POWER LIGHT FIXTURES IN THIS ROOM / AREA TO EXISTING 277V, 20A, 1P NORMAL
POWER CIRCUIT THAT WAS MAINTAINED DURING DEMOLITION. MAINTAIN EXISTING LIGHTING CONTROL. EXTEND /
MODIFY EXISTING WIRING / CONDUIT AS REQUIRED.
5 CONNECT NEW LIFE SAFETY POWER LIGHT FIXTURES IN THIS ROOM / AREA TO EXISTING 277V, 20A, 1P LIFE
SAFETY POWER CIRCUIT THAT WAS MAINTAINED DURING DEMOLITION. MAINTAIN EXISTING LIGHTING CONTROL.
EXTEND / MODIFY EXISTING WIRING / CONDUIT AS REQUIRED.
6 TELECOM RECEPTACLE LOCATION. PROVIDE BACK BOX AND CONDUIT AS REQUIRED. REFER TO DETAILS FOR
ADDITIONAL INFORMATION.
7 CONNECT NEW NORMAL POWER RECEPTACLE TO EXISTING 120V, 20A, 1P NORMAL CIRCUIT THAT WAS
MAINTAINED DURING DEMOLITION. EXTEND / MODIFY EXISTING WIRING / CONDUIT AS REQUIRED.
8 CONNECT FIRE ALARM DEVICE SHOWN RETAINED FROM LAB DEMOLITION. CONNECT FIRE ALARM DEVICE TO
EXISTING FIRE ALARM SYSTEM COMPLETE. PROVIDE MODIFICATION TO EXISTING SYSTEM INCLUDING BUT NOT
LIMITED TO PROGRAMMING, NAC PANELS AND POWER TO NAC PANELS.
9 PROVIDE DEDICATED CIRCUIT.
10 WHITE NOISE EMITTER. CONNECT TO HEADEND EQUIPMENT COMPLETE.
11 WHITE NOISE HEADEND EQUIPMENT. CONNECT TO RECEPTACLE IN STORAGE.
# Revision Description
Date
Issued
06/08/21