HomeMy WebLinkAboutH001 - Mechanical Symbols and General NotesALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECTT SENSOR (T=TEMP H=HUMIDITY) (P=PRES V=VAC T=TEMP) GAUGE THERMOMETER PRESSURE AND TEMPERATURE PLUG WATER PRESSURE REDUCING/REGULATING VALVE AUTOMATIC AIR VENT MANUAL AIR VENT FLOOR DRAIN FLOW METER CLEANOUT TEMPERATURE CONTROL 3-WAY 2-POSITION VALVE MECHANICAL VALVE AND FITTING SYMBOLS DESCRIPTIONSYMBOL TEMPERATURE CONTROL 2-WAY MODULATING VALVE TEMPERATURE CONTROL 2-WAY 2-POSITION VALVE TEMPERATURE CONTROL 3-WAY MODULATING VALVE CALIBRATED BALANCING VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED/FLANGED CAP CONCENTRIC REDUCER CHECK VALVE UNION STRAINER SAFETY RELIEF VALVE BUTTERFLY VALVE BALL VALVE GATE VALVE PLAN VIEW DETAIL VIEW R OR D FD SD F/SD MD DESCRIPTIONSYMBOL DESCRIPTION MECHANICAL DUCTWORK SYMBOLS SYMBOL WITH FLEX DUCT SECTION PLAN VIEW STANDARD RADIUS ELBOW WITH CENTER RADIUS EQUAL TO 1-1/2 TIMES WIDTH OF DUCT UNLESS OTHERWISE INDICATED FLAT OVAL SPIRAL DUCT (FIRST DIMENSION, SIDE SHOWN) RECTANGULAR DUCT (FIRST DIMENSION, SIDE SHOWN) SPIN-IN FITTING WITH MANUAL VOLUME DAMPER AND FLEXIBLE DUCT CONNECTION TYPICAL TERMINAL UNIT WITH REHEAT COIL GRILLE/REGISTER/DIFFUSER CONNECTION SIDEWALL SUPPLY, RETURN OR EXHAUST GRILLE DIFFUSER (NO AIRFLOW IN SHADED DIRECTION) INSULATED METAL PANEL 45 DEGREE LATERAL (ROUND OR FLAT OVAL ONLY) 90 DEGREE TEE (ROUND OR FLAT OVAL ONLY) SQUARE-TO-ROUND TRANSITION CONICAL FITTING ROUND SPIRAL DUCT 90 DEGREE ELBOW WITH TURNING VANES FLEXIBLE CONNECTION BEVELED ENTRY FITTING MANUAL VOLUME DAMPER FIRE DAMPER WITH ACCESS DOOR SMOKE DAMPER WITH ACCESS DOOR FIRE/SMOKE DAMPER WITH ACCESS DOOR DUCT TURNED UP (SOLID LINES) DUCT TURNED DOWN (DASHED LINES) R(RISE), D(DROP) SUPPLY DIFFUSER OR SUPPLY GRILLE RETURN GRILLE EXHAUST GRILLE SUPPLY, RETURN, OR EXHAUST SLOT DIFFUSER W" X H" DIA"ø AUTOMATIC MOTOR OPERATED DAMPER W "X H"ø DIA"ø W" X H" CD CPD CHWR CR CS CHWS HWS HWR DIRECTION OF PIPE SLOPE (DOWN) CONDENSATE & EQUIPMENT DRAIN CONDENSATE PUMP DISCHARGE CONDENSER WATER RETURN CONDENSER WATER SUPPLY CHILLED WATER RETURN CHILLED WATER SUPPLY HEATING WATER RETURN HEATING WATER SUPPLY HVAC PIPING SYMBOLS LINE SYMBOLS SCREENED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED AD ACCESS DOOR Ø °F A/E ACC ACCU AD ADJ AFCV AFF AFMS AGA AHU AL ANSI AO AP APD ARI AS ASHRAE ASME ASPE ASTM ATM AUTO AWWA B BCU BD BDD BHP BI BOD BOP BTUH CA CAP CAV CB CD CO2 CFM CH CHWP CHWR CHWS CO COMP COND CONV CP CPD CR CS CT CUH CWP dB DD DDC DEG DIA DISC DWH DWV DX EA EAT EC ECG EDR EER EF EFF EFT EG EMG EOM ESP ET EWT EXH F F&T FCO FCU FD FM FPB FPM FPS PHASE DEGREES FAHRENHEIT ARCHITECT/ENGINEER AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT AREA DRAIN, ACCESS DOOR ADJUSTABLE, ADJACENT AIRFLOW CONTROL VALVE ABOVE FINISHED FLOOR AIRFLOW MEASURING STATION AMERICAN GAS ASSOCIATION AIR HANDLING UNIT ALUMINUM AMERICAN NATIONAL STANDARDS INSTITUTE ANALOG OUTPUT ACID PROOF, ACCESS PANEL AIR PRESSURE DROP (IN. WC) AIR CONDITIONING REFRIGERATION INSTITUTE AIR SEPARATOR AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS AMERICAN SOCIETY OF MECHANICAL ENGINEERS AMERICAN SOCIETY OF PLUMBING ENGINEERS AMERICAN SOCIETY FOR TESTING AND MATERIALS ATMOSPHERE AUTOMATIC AMERICAN WATER WORKS ASSOCIATION BOILER BLOWER COIL UNIT BALANCE DAMPER BACK-DRAFT DAMPER BRAKE HORSEPOWER OR BOILER HORSEPOWER BINARY INPUT, BACKWARD INCLINED BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR CAPACITY CONSTANT AIR VOLUME CATCH BASIN OR CHILLED BEAM CONDENSATE DRAIN CARBON DIOXIDE CUBIC FEET PER MINUTE CHILLER CHILLED WATER PUMP CHILLED WATER RETURN CHILLED WATER SUPPLY CLEANOUT COMPRESSOR CONDENSER CONVECTOR CONDENSATE PUMP CONDENSATE PUMP DISCHARGE CONDENSER WATER RETURN CONDENSER WATER SUPPLY COOLING TOWER CABINET UNIT HEATER CONDENSER WATER PUMP DECIBEL DUAL DUCT DIRECT DIGITAL CONTROL DEGREE (°F) DIAMETER DISCONNECT SWITCH DOMESTIC WATER HEATER DRAIN, WASTE, AND VENT DIRECT EXPANSION EXHAUST AIR ENTERING AIR TEMPERATURE (°F) ELECTRICAL CONTRACTOR EGG-CRATE GRILLE EQUIVALENT DIRECT RADIATION ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY ENTERING FLUID TEMPERATURE (°F) EXHAUST GRILLE EXTRUDED METAL GRILLE (WELDED WIRE MESH) END OF MAIN DRIP EXTERNAL STATIC PRESSURE (IN. WC.) EXPANSION TANK ENTERING WATER TEMPERATURE (°F) EXHAUST FURNACE FLOAT AND THERMOSTATIC STEAM TRAP FLOOR CLEANOUT FAN COIL UNIT FLOOR DRAIN FACTORY MUTUAL FAN POWERED TERMINAL UNIT FEET PER MINUTE FEET PER SECOND ABBREVIATIONS AND TERMS FLOOR SINK FIRE/SMOKE DAMPER FINNED TUBE RADIATION GAGE OR GUAGE GALLON GENERAL CONTRACTOR GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE HEAD (FT.) HORSEPOWER HIGH PRESSURE STEAM RETURN HIGH PRESSURE STEAM SUPPLY HOT WATER PUMP HEATING WATER RETURN HEATING WATER SUPPLY HEAT EXCHANGER INTEGRAL FACE/BYPASS LEAVING AIR TEMPERATURE (°F) LOW PRESSURE STEAM RETURN LOW PRESSURE STEAM SUPPLY LEAVING WATER TEMPERATURE (°F) MIXED AIR MIXED AIR TEMPERATURE (°F) THOUSAND BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MEDIUM PRESSURE STEAM RETURN MEDIUM PRESSURE STEAM SUPPLY NOISE CRITERIA, NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL FIRE CODE NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE (°F) OPPOSED BLADE DAMPER OUTSIDE DIAMETER OWNER FURNISHED/CONTRACTOR INSTALLED PUMP PLUMBING CONTRACTOR PRESSURE DROP PRE-FILTER PROPYLENE GLYCOL WATER PREHEAT COIL PARTS PER MILLION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH (ABSOLUTE) POUNDS PER SQUARE INCH (GAUGE) PACKAGED TERMINAL AIR CONDITIONER RETURN AIR RETURN AIR TEMPERATURE (°F) RETURN FAN RETURN GRILLE RELATIVE HUMIDITY REHEAT COIL RADIANT PANEL ROOFTOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE (°F) SUPPLY DIFFUSER SEASONAL ENERGY EFFICIENCY RATIO SUPPLY GRILLE SHEETMETAL AND AIR CONDITIONING CONTRACTORS ASSOCIATION STATIC PRESSURE SUPPLY REGISTER SAFETY RELIEF VALVE STEAM VENT THERMOSTAT TEMPERATURE CONTROL CONTRACTOR TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE THERMAL EXPANSION VALVE TYPICAL UNIT HEATER UNDERWRITER'S LABORATORIES VARIABLE AIR VOLUME VOLUME DAMPER VARIABLE FREQUENCY CONTROLLER (SAME AS VFD, VSC) VARIABLE FREQUENCY DRIVE (SAME AS VFC, VSC) VARIABLE SPEED CONTROLLER (SAME AS VFC, VFD) WITH WITHOUT WET BULB TEMPERATURE (°F) WATER PRESSURE DROP (FT. HD) WATER SOURCE HEAT PUMP FS FSD FTR GA GAL GC GPD GPH GPM HD HP HPR HPS HWP HWR HWS HX IFB LAT LPR LPS LWT MA MAT MBH MC MCA MCC MD MPR MPS NC NEC NFC NFPA NIC NO NTS OA OAT OBD OD OF/CI P PC PD PF PGW PHC PPM PRV PSI PSIA PSIG PTAC RA RAT RF RG RH RHC RP RTU SA SAT SD SEER SG SMACNA SP SR SRV SV T TCC TD TSP TXV TYP UH UL VAV VD VFC VFD VSC W/ W/O WB WPD WSHP ECCENTRIC REDUCER GLOBE VALVE T STEAM TRAP VACUUM BREAKER SHEET SYMBOLS EXTENT OF DEMOLITION CONNECT TO EXISTING GENERAL MECHANICAL DEMOLITION NOTES A. CONTRACTOR TO FIELD VERIFY EXISTING DUCTWORK LOCATION, SIZE, AND ELEVATION PRIOR TO REMOVAL. COORDINATE ANTICIPATED ROUTING WITH EXISTING AND NEW DUCTWORK, PIPING, AND CONDUITS. CONTACT ENGINEER IF FIELD CONDITIONS REQUIRE ALTERNATIVE ROUTING. VERIFY THAT ALL SERVICES TO BE REMOVED DO NOT SERVE AREAS OUTSIDE INDICATED SCOPE OF WORK. B. PIPE AND DUCT ROUTINGS AND CLEARANCES INDICATED ARE BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY PIPING, DUCTWORK, ELECTRICAL, AND STRUCTURAL DETAILS OF EXISTING AND NEW INSTALLATIONS DURING AND AFTER DEMOLITION (PRIOR TO NEW INSTALLATIONS) TO DETERMINE WORK NECESSARY TO INSTALL WORK AS SHOWN AND INTENDED. CONTRACTOR SHALL CONTACT THE ENGINEER WITH ANY CONCERNS UPON COMPLETION OF THIS EFFORT. C. COORDINATE OUTAGES WITH OTHER CONTRACTORS, OWNER, AND MAINTENANCE STAFF. PROVIDE SUFFICIENT ADVANCE SCHEDULING TO MEET OCCUPANTS AND FACILITY PERSONNELS REQUIREMENTS FOR PLANNING AND COORDINATING FOR SYSTEMS WHICH MAY NOT BE EASILY INTERRUPTED. D. WHERE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION WORK IS DETERMINED TO PENETRATE EXISTING FLOORS, WALLS, CEILING, OR ROOF, THE OPENING THROUGH WHICH THE ABOVE DESCRIBED ITEM IS TO PASS MUST BE REPAIRED OR BUILT BACK BY THE CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR PROCURRING THE SERVICES OF SKILLED CONTRACTOR. E. PROVIDE TEMPORARY PATCHING AS REQUIRED FOR INFECTION CONTROL AS DETERMINED BY HOSPITAL INFECTION CONTROL DEPARTMENT AND MAINTAIN EXISTING FIRE AND SMOKE RATINGS. F. WHERE PRE-DEMOLITION AIRFLOW READINGS ARE NOTED, TAKE READINGS PRIOR TO BEGINNING ANY DEMOLITION WORK OR CONSTRUCTING NEGATIVE AIR PRESSURE BARRIERS. PRE- DEMOLITION TAB WORK WILL LIKELY OCCUR AFTER NORMAL HOURS, CONFIRM WITH OWNER. G. ALL DUCTWORK, PIPING, AND EQUIPMENT INDICATED BY DASHED LINETYPE SHALL BE REMOVED AS DESCRIBED BY PLAN NOTES. REMOVE OR REUSE ASSOCIATED HANGERS. DO NOT LEAVE UNUSED EQUIPMENT ABANDONED ABOVE CEILING. ALL TERMINAL UNITS TO BE REMOVED SHALL ALSO HAVE SUPPLY DUCTS REMOVED BACK TO MAIN DUCTS AS INDICATED AND CAP SUITABLE FOR +4" W.G. REMOVE PIPING RUNOUTS BACK TO MAIN AND CAP. FOR PIPING RUNOUTS THAT ARE TO BE REUSED, REMOVE ALL CONTROL VALVES, BALANCE VALVES, STRAINERS , AND PIPING ACCESSORIES TO BRANCH SHUT-OFF VALVES. ALL EXISTING TERMINAL UNITS, DDC CONTROLLERS, ROOM PRESSURE MONITORS, AND HARDWARE TO BE REMOVED SHALL BE DONE SO IN A MANNER TO MINIMIZE DAMAGE AND OFFERED TO THE OWNER. CONTRACTOR SHALL DISCARD ALL DEVICES NOT WISHED TO BE RETAINED BY THE OWNER. GENERAL MECHANICAL NOTES A. CONTRACTOR TO INSTALL ACCESS PANELS AT ALL FIRE DAMPERS. REFER TO DETAILS AND SPECIFICATIONS FOR MINIMUM ACCESS PANEL SIZES. COORDINATE LOCATIONS TO ENSURE ACCESS PANELS ARE NOT OBSTRUCTED. B. REFER TO SCHEDULES FOR DIFFUSER AND TERMINAL UNIT RUNOUT SIZES. C. UNLESS NOTED OTHERWISE, TERMINAL UNIT DISCHARGE DUCT SHALL BE THE SAME SIZE AS THE TERMINAL UNIT DISCHARGE CONNECTION. D. LOCATE ALL TERMINAL UNITS, DAMPERS, VALVES, AND EQUIPMENT REQUIRING ACCESS IN AN UNOBSTRUCTED LOCATION ABOVE LAY-IN CEILING. COORDINATE THE INSTALLATION OF A CEILING ACCESS PANEL WITH GENERAL CONTRACTOR. E. FIELD VERIFY LOCATION OF ALL FLOOR PENETRATIONS PRIOR TO CUTTING TO ASSURE THAT NO FLOOR PENETRATION CONFLICTS WITH EXISTING BEAMS OR JOISTS. FLOOR PENETRATIONS SHALL BE ONLY THROUGH THE SLAB. DO NOT CUT THROUG BEAMS OR JOISTS. NOTIFY ARCHITECT AND ENGINEER FOR ANY REQUIRED MODIFICATIONS PRIOR TO CUTTING. F. REFER TO TERMINAL UNIT SCHEDULE FOR PIPE RUNOUT SIZES. G. MINIMUM PIPE SIZE SHALL NOT BE LESS THAN 3/4". H. ALL NEW AIR-HANDLING SYSTEMS AND ASSOCIATED DISTRIBUTION SHALL COMPLY WITH NFPA-90A. I. ALL DUCTWORK AND PIPE INSULATION SHALL BE INSTALLED CONTINUOUSLY THROUGH WALLS. OPENINGS SHALL BE FRAMED LARGE ENOUGH TO ACCOMMODATE INSULATED PIPE/DUCT. ALLOW ENOUGH ANNULAR SPACE FOR PROPER SEALANT. NON-RATED WALLS SHALL HAVE NON- COMBUSTIBLE SEALANT. RATED BARRIERS SHALL HAVE A UL-LISTED FIRESTOPPING ASSEMBLY. INSTALL FIRESTOPPING ASSEMBLY IN COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH UL-LISTED ASSEMBLY. J. COORDINATE THERMOSTATS, HUMIDISTATS, DIFFERENTIAL PRESSURE SENSORS, AND ALL OTHER WALL MOUNTED DEVICES WITH ALL DISCIPLINES PRIOR TO ROUGHING IN. K. REFER TO H801 DRAWING FOR DETAILS. WHERE APPROPRIATE, SPECIFIC DETAILS HAVE BEEN REFERENCED ON THE PLANS. IN ORDER TO MAINTAIN DRAWING CLARITY, NOT ALL DETAILS HAVE BEEN CALLED OUT BUT DO PERTAIN TO THE SCOPE OF THIS PROJECT. L. CONTRACTOR SHALL DRAIN SYSTEM PIPING AS NECESSARY. BUILDING WILL REMAIN IN OPERATION DURING CONSTRUCTION. M. PROTECT ALL SUPPLY, RETURN, AND EXHAUST AIR OPENINGS THROUGHOUT CONSTRUCTION FROM DAMAGE, DIRT, AND DEBRIS. N. CLEAN ALL SUPPLY DIFFUSERS, RETURN AIR GRILLES THAT ARE EXISTING TO REMAIN PRIOR TO PROJECT COMPLETION TO REMOVE ANY DIRT OR DEBRIS. www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Mechanical Symbols and General Notes H00110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21