HomeMy WebLinkAboutH801 - HVAC Schedules and DetailsGRILLE SCHEDULE TAG NOM SIZE NECK MAX NC TYPE MFR MODEL FINISH NOTES R1 24 x 12 - 20 EGGCRATE GRILLE PRICE 80 WHITE 1 , 2 NOTES: 1.CONFIRM FINAL FINISHES WITH ARCHITECT. 2.PROVIDE FRAME STYLE APPROPRIATE FOR CEILING TYPE (I.E. LAY-IN, SURFACE MOUNT, SIDEWALL, ETC.) REFER TO DRAWINS AND ARCHITECTURAL CEILING PLANS FOR LOCATIONS. COLOR AND FINISH TO BE APPROVED BY ARCHITECT. AIR CHANGE SCHEDULE ROOM NUMBER ROOM NAME AREA (SQ. FT) OCCUPANTS CEILING HEIGHT (FT.) % OA ROOM CLASSIFICATION ASHRAE 170 - 2017 2012 MECHANICAL CODE / ASHRAE 62.1 MINIMUM AIR VOLUME MAXIMUM AIR VOLUME EXHAUSTMIN OA ACH REQ'D MIN AIRFLOW ACH REQUIRED PRESSURE RELATIONSHIP TO ADJACENT AREAS ALL ROOM EXHAUSTED DIRECTLY OUTDOORS OUTDOOR AIRFLOW RATE (CFM/PERSON) OUTDOOR AIRFLOW RATE (CFM/SQ FT) MINIMUM OUTSIDE AIR OA SUPPLIED SPACE AIRFLOW OA ACH ACH AIRFLOW OA ACH ACH 1 WAITING 348 5 11 19% RECEPTION AREA - - - - 5 0.06 57 60 315 0.9 4.9 630 1.9 9.9 2 OFFICE 95 1 8.5 19% OFFICE - - - - 5 0.06 13 32 165 2.3 12.3 250 3.5 18.6 3 RECEPTION 175 4 11 19% RECEPTION AREA - - - - 5 0.06 38 47.8 250 1.5 7.8 500 3.0 15.6 4 MD NURSE 163 4 8.5 19% OFFICE - - - - 5 0.06 37 47.8 250 2.1 10.8 500 4.1 21.7 5 W&M 133 0 10 19% CORRIDOR - - - - 0 0.06 10 6.7 35 0.3 1.6 35 0.3 1.6 6 PATIENT RR 53 0 8.5 19% TOILET ROOM - 10 NEGATIVE YES - - - 15.3 80 - 10.7 - - - 80 7 EXAM 1 113 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 35.3 185 2.2 11.6 260 3.1 16.2 8 EXAM 2 122 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 35.3 185 2.0 10.7 260 2.9 15.0 9 EXAM 3 117 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 33.4 175 2.0 10.6 300 3.5 18.1 10 STORAGE 33 0 8.5 19% CLEAN LINEN STORAGE 0 2 POSITIVE NR 5 0.06 2 5.7 30 1.2 6.4 20 0.8 4.3 11 EXAM 4 94 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 26.7 140 2.0 10.5 140 2.0 10.5 12 WORK ALCOVE 90 1 8.5 19% OFFICE - - - - 5 0.06 13 13.0 68 1.0 5.3 70 1.0 5.5 1 2 DUCTWORK/DIFFUSER SHALL BE SUPPORTED INDEPENDENTLY FROM STRUCTURE (NOT SUPPORTED BY CEILING) INSIDE OF PLENUM TO BE PAINTED FLAT BLACK. INSULATED FLEXIBLE DUCTWORK ADJUST AIR FLOW SLOTS PER SCHEDULE AND PLANS. PLAN NOTES 1. A MAXIMUM OF FIVE (5) FEET LENGTH OF FLEXIBLE DUCT SHALL BE PROVIDED TO EACH DIFFUSER. DUCTWORK SHALL CONTAIN 180° OF BENDING. FLEX DUCT SHALL NOT CONTACT CEILING AND SHALL BE PROPERLY SUPPORTED SO AS TO HAVE NO KINKS. 2. TIE-WRAP CONNECT FLEX DUCT HELICAL COIL TO ROUND METAL DIFFUSER NECK AND TO ROUND METAL DUCTWORK AT OTHER END OF FLEX DUCT. PULL FLEX DUCT VAPOR BARRIER OVER LOWER TIE-WRAP AND INSTALL SECOND TIE-WRAP OVER THE VAPOR BARRIER. INSULATE METAL DUCT OR DIFFUSER OVER TOP OF SECOND TIE-WRAP AND INSTALL INSULATOR'S TAPE ON EDGES. ROUND BRANCH DUCT TO MAIN (SEE SCHEDULE FOR SIZE) PLENUM BOX HEIGHT = ROUND DUCT DIAMETER + 4" SLOT DIFFUSER (THREE SLOT SHOWN) EXTERNALLY INSULATE PLENUM. INTERNAL INSULATION IS NOT ALLOWED. RETURN GRILLE 8" SHEETMETAL DUCT BOOT. COVER INSIDE WITH 3/4" ARMAFLEX INSULATION. CEILING SUPPORT ROD 24" SUPPORT RETURN GRILLE AND SOUND BOOT FROM STRUCTURE ABOVE. MINIMUM 8" OR HIGHER TO CLEAR LIGHTS AND ASSOCIATED ACCESS ABOVE LIGHTS.8" www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 HVAC Schedules and Details H80110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued NO SCALE2LINEAR SLOT DIFFUSER DETAIL NO SCALE3RETURN GRILLE WITH SOUND BOOT DETAIL 06/08/21