Loading...
HomeMy WebLinkAboutP101 - First Floor Plumbing PlansA. ALL CONTRACT DOCUMENTS (SPECIFICATIONS AND DRAWINGS) ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. ALL CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENGINEERS ATTENTION IN ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK. B. THE CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS AND ACCESSORIES TO CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE INCLUDED IN THE COST OF THIS PROJECT. C. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR MAY AT THEIR OPTION MODIFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS SET OF CONSTRUCTION DOCUMENTS. D. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS. E. ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS AND/OR STRUCTURAL MEMBERS FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE PROVIDED AS PART OF THE SCOPE OF THIS PROJECT. F. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL. G. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND REQUIREMENTS. H. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE LOCATION OF THE WORK BEING INSTALLED. I. ALL PLUMBING EQUIPMENT, PIPING, FIXTURES, AND PIPE ACCESSORIES SHALL BE NSF 61, ANNEX G COMPLIANT. J. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25/50 FLAME SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR FURTHER CLARIFICATION. K. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHER TIGHT BY THE APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. L. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST CROSS BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON-STRUCTURAL ITEM. M. DO NOT WELD OR DRILL INTO STRUCTURAL STEEL OR JOIST; INSTEAD USE CLAMPS, TIE WIRE, THRU-BOLTS WITH WASHERS N. DO NOT USE ANY PVC, PLASTIC, ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED. ALL WOOD BLOCKING AND NAILERS, CONCEALED OR NOT SHALL BE FIRE RETARDANT TREATED. O. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING; ROUTE THROUGH ROOF USING LANDLORDS ROOFING CONTRACTOR. P. VENT THROUGH ROOF INSTALLATION; ALL ROOFING WORK SHALL BE COMPLETED BY THE LANDLORDS ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. Q. PIPING BELOW GROUND SHALL BE SERVICE-WEIGHT CAST IRON OR SCHEDULE 40 PVC. NO-HUB PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE. R. DOMESTIC WATER PIPING ABOVE GRADE SHALL BE TYPE "L" WATER TUBE. S. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES. T. ALL PIPING INSULATED SHALL BE WITH PLENUM RATED MATERIALS. U. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMERS. TRAP PRIMER PIPES SHALL BE FIELD ROUTED AND FIELD INSTALLED. V. ALL SHUT-DOWN OF UTILITIES AND FIRE PROTECTION SYSTEMS SHALL BE ARRANGED WITH NO LESS THAN SEVEN (7) DAYS NOTICE TO THE LANDLORD. WORK MAY NOT COMMENCE UNLESS WRITTEN APPROVAL IS PROVIDED BY THE OWNER. W. ALL DOMESTIC WATER BRANCH PIPES SERVING FIXTURES OR EQUIPMENT WITH FAST ACTING OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS. X. ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN. Y. CONTRACTOR SHALL CAMERA INSPECT AND LOCATE ALL SANITARY PIPE LOCATED BELOW SLAB, ADVISE OWNER OF ANY DEFECTS PRIOR TO STARING ANY WORK. ALL CAMERA INSPECTION AND LOCATING SHALL BE COMPLETED PRIOR TO INSTALLATION OF ANY PIPE. CONTRACTOR MAY MODIFY ROUTING OF PIPE, KEEP AS-BUILT DOCUMENTS THROUGHOUT THE ENTIRE PROJECT. Z. CONTRACTOR SHALL REMOVE ONLY WASTE VENT, HOT AND COLD WATER PIPE AS REQUIRED (BACK TO MAINS) TO ACCOMMODATE THE NEW FLOOR PLANS. ALL EXISTING SANITARY AND WASTE PIPE SERVING THE FLOOR ABOVE SHALL BE LEFT IN PLACE. THE CONTRACTOR SHALL FIELD MODIFY ANY EXISTING SANITARY PIPE AS REQUIRED TO ACCOMMODATE THE NEW FLOOR PLANS. GENERAL NOTES (REQUIRED TO COMPLETE THE SCOPE OF WORK)2 E.5 F F.9 G.1 .9 3 3 3 3 4 4 4 5 2 E.5 F F.9 G.1 .9 2 1 16 2 2 1 2 6 6 6 8 9 2 13 13 13 13 2 9 15 2 E.5 F F.9 G.1 .9 Standard 3" S 3" S 2" V 2" V 2" S 2" S 10 2" S2" S 2" S 14 2 E.5 F F.9 G.1 .9 1 1/2" DCW 1/2" DHW 3/4" DCW 2" V 1/2" DCW 1/2" DCW 1/2" DHW 1/2" DCW WC-1 2" V 2" V 11 11 12 12 1/2" DHW WAITING 001RECEPTION 003 OFFICE 002 MD NURSE 004 EXAM 1 007 EXAM 2 008 EXAM 3 009 EXAM 4 011 PATIENT RR 006 STORAGE 010 WORK ALCOVE 012 W&M 005 7 7 7 7 17 2" S 2" S 2" S 2" V 2" V 2" V 2" S 2" V 2" V WC-1 2" V 2" V 3" S 2" V 3" S www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 First Floor Plumbing Plans P10110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290PLAN NOTES 1 REMOVE EXISTING PLUMBING FIXTURE COMPLETE. REMOVE ALL ROUGH-IN PIPING AND ASSOCIATED ACCESSORIES COMPLETE. INCLUDING SANITARY WASTE AND VENT AND DOMESTIC WATER RISERS. 2 PLUMBING CONTRACTOR SHALL REMOVE AND SALVAGE THE EXISTING PLUMBING FIXTURE AND FACUET TO BE REINSTALLED IN NEW CASEWORK IN THE NEW EXAM ROOMS. 3 REMOVE SANITARY PIPE THROUGH FLOOR JUST BELOW SLAB AND PLUG. 4 REMOVE SECTION OF SANITARY PIPE AND PLUG BOTH ENDS. 5 CUT AND CAP EXISTING SANITARY PIPE. 6 CUT AND CAP EXISTING DHW & DCW PIPING. 7 PLUMBING CONTRACTOR SHALL SELECT FROM THE SALVAGED FIXTURES AND FAUCETS WHICH ONES ARE OF THE BETTER CONDITION AND REINSTALL AT THIS LOCATION. ANY FIXTURES AND FAUCETS NOT REUSED MAY BE DISCARDED AT THE END OF THE PROJECT. MODIFY EXISTING PLUMBING ROUGHINS AS NEEDED TO ACCOMMODATE REINSTALLED PLUMBING FIXTURES. 8 CUT AND CAP EXISTING VENT PIPE. 9 CUT EXISTING VENT PIPE AND PREP FOR RECONNECTION. 10 CONNECT 3" S TO EXISTING SANITARY PIPING. 11 CONNECT 2" V TO EXISTING VENT PIPING. 12 CONNECT 1/2" DHW & DCW PIPING TO EXISTING DWH & DCW. 13 EXISTING AREA ALREADY HAS A SPRINKLER SYSTEM IN PLACE. FP CONTRACTOR SHALL RELOCATE MAINS OR BRANCH PIPING TO ACCOMMODATE NEW ARCHITECHTURAL FLOOR PLAN AND CEILING GRID. FP CONTRACTOR SHALL PROVIDE COMPLETE AND OPERATIONAL SYSTEM PER NFPA REQUIREMENTS. 14 CONNECT 2" S TO EXISTING SANITARY PIPING. 15 CUT EXISTING 2" S PIPE AND PREP FOR RECONNECTION. PLUMBING CONTRACTOR SHALL VERIFY WHAT THIS LINE IS SERVING AND RECONNECT TO THE SANITARY WASTE AND VENT SYSTEM AS REQUIRED. 16 PLUMBING CONTRACTOR SHALL REMOVE AND SALVAGE THE EXISTING PLUMBING FIXTURE AND FACUET TO BE REINSTALLED. 17 REINSTALL SALVAGED LAVATORY AT THIS LOCATION. INSTALL WALL HUNG LAVATORY AT ADA HEIGHT WITH OFFSET TRAP TO ALLOW FOR ADA CLEARANCE UNDERNEATH THE FIXTURE. PROVIDE PROTECTIVE SHIELDING GUARDS TO COVER HOT AND COLD WATER SUPPLIES AND TRAP AND DRAIN PIPING. 1/8" = 1'-0"1 Level Foundation Demolition Plan 1/8" = 1'-0"2 First Floor Plumbing Demolition Plan 1/8" = 1'-0"3 Level Foundation Sanitary Plan 1/8" = 1'-0"4 First Floor Plumbing Plan 5 SANITARY RISER DIAGRAM -GI CLINIC # Revision Description Date Issued 06/08/21