HomeMy WebLinkAboutSpringmill Suite1200 - Combined Setwww.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 COVER SHEET 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290DRAWING LIST # Sheet Name ARCHITECTURE A000 COVER SHEET A001 INFORMATION SHEET A002 ACCESSIBILITY GUIDELINES A003 GENERAL SPECIFICATIONS A004 LIFE SAFETY PLAN A050 DEMOLITION PLAN A100 FLOOR PLAN A120 REFLECTED CEILING PLAN A600 INTERIOR ELEVATIONS A702 CASEWORK DETAILS VICINITY MAPPROJECT TEAM PROJECT LOCATION 10300 N. Illinois St Indianapolis, IN 46290 IU HEALTH SPRINGMILL CONSTRUCTION DOCUMENTS 705 Riley Hospital Dr, Indianapolis, IN 46202 Contact: CHARLENE WILDER Email: cwilder1@iuhealth.org Phone: 317.962.4698 Owner: RILEY HOSPITAL FOR CHILDREN INDIANAPOLIS, IN 46250 8604 ALLISONVILLE ROAD, SUITE 330 Contact: HEATHER LESLIE Email: hleslie@studio3design.net Phone: (317) 595.1000 Architect: STUDIO 3 DESIGN, INC. 91 S MAIN ST #200 ZIONSVILLE, IN 46077 Contact: WILLIAM MALTBY Email: wmaltby@genesis-engineering.com Phone: 317.847.7480 Engineer: GENESIS ENGINEERING GROUP 1850 WEST 15TH STREET INDIANAPOLIS, IN 46202 Contact: NATE LAGRANGE Email: NLAGRANGE@PEPPERCONSTRUCTION.COM Phone: (317) 775.9527 General Contractor: PEPPER CONSTRUCTION # Revision Description Date Issued MECHANICAL H001 MECHANICAL SYMBOLS AND GENERAL NOTES H002 HVAC SPECIFICATIONS H003 HVAC SPECIFICATIONS H004 HVAC SPECIFICATIONS H101 FIRST FLOOR HVAC PLANS H801 HVAC SCHEDULES AND DETAILS PLUMBING P001 PLUMBING SYMBOLS AND GENERAL NOTES P003 PLUMBING SPECIFICATIONS AND SCHEDULES P100 PLUMBING LOBBY PLANS P101 FIRST FLOOR PLUMBING PLANS ELECTRICAL E001 ELECTRICAL SYMBOLS AND GENERAL NOTES E002 ELECTRICAL SPECIFICATIONS E101 FIRST FLOOR ELECTRICAL PLANS E801 ELECTRICAL SCHEDULES AND DETAILS 06/08/21 BUILDING / EXTERIOR ELEVATION REFERENCE ELEVATION REF. SHEET REF. WINDOW REFERENCE A ELEVATION OR WORK POINT ?NORTH ORIENTATION REFERENCE DOOR SYMBOL ? ?ROOM IDENTIFICATION WALL TYPE 1 PLAN KEY NOTE DEMOLITION PLAN KEY NOTE NEW DOOR / RELOCATED DOOR EXISTING DOOR DEMO DOOR / WALL DEMO EXISTING WALL NEW WALL EXISTING WALL TO BE REMOVED PARTIAL HEIGHT WALL 5C A600 DETAIL REFERENCE 1 A 1E A200 3E A600 INTERIOR ELEVATION REFERENCE ELEVATION REF. SHEET REF. NEW WALL IN RENOVATION PROJECT SECTION REFERENCE ELEVATION REF. SHEET REF. 1E A200 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 INFORMATION SHEET 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290GENERAL PROJECT NOTES CONTRACTOR'S RESPONSIBILITIES: 1. SHOULD THERE BE ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, EXISTING CONDITIONS, AND/OR DESIGN INTENT, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ARCHITECT PRIOR TO BID SUBMITTAL PRIOR TO PROCEEDING WITH ANY WORK, OR RELATED WORK IN QUESTION. 2. THESE CONTRACT DOCUMENTS ARE INTENDED TO DESCRIBE ONLY THE SCOPE AND APPEARANCE OF THE REAL PROPERTY IMPROVEMENTS, INCLUDING THE PERFORMANCE AND LEVEL OF QUALITY EXPECTED OF ITS COMPONENTS. IT IS INCUMBENT UPON THE CONTRACTOR TO INSURE THAT ALL WORK COMPLETED AND MATERIALS INSTALLED BE IN FULL COMPLIANCE, AS A MINIMUM STANDARDS, WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES HAVING JURISDICTION. 3. THESE CONTRACT DOCUMENTS DO NOT ATTEMPT TO INSTRUCT THE CONTRACTOR IN THE DETAILS OF HIS TRADE. THEY ARE PERFORMANCE SPECIFICATIONS IN THAT THEY DO REQUIRE THAT ALL MANUFACTURED ITEMS, MATERIALS AND EQUIPMENT BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDED SPECIFICATIONS, EXCEPT IN THE CASE WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR PROPER INSTALLATION SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR(S) RESPONSIBLE FOR THE AFFECTED PORTION OF WORK. 4. ALL WORK SHALL BE WARRANTED SATISFACTORY, IN MATERIALS AND WORKMANSHIP, FOR A MINIMUM PERIOD OF ONE (1) YEAR, OR FOR THE PERIOD OF WARRANTY CUSTOMARY, OR STIPULATED FOR, THE TRADE, CRAFT, OR PRODUCT, WHICHEVER IS LONGER. THEREFORE, ONLY COMPETENT MECHANICS CAPABLE OF PRODUCING GOOD WORKMANSHIP CUSTOMARY TO THE TRADE SHALL BE USED. 5. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, OR THE AUTHORIZED, AGENT, TO DETERMINE ALL EXISTING MATERIALS TO BE SALVAGED AND RETAINED BY THE OWNER. THE CONTRACTOR SHALL REMOVE SALVAGEABLE MATERIALS FROM THE SPACE AND STORE IN A LOCATION AS DIRECTED BY THE OWNER. ALL OTHER MATERIALS, RUBBISH, AND DEBRIS, SHALL BE REMOVED AND PROMPTLY DISPOSED OF BY THE CONTRACTOR AT AN OFFSITE LOCATION. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ASSURE THAT ALL PROPERTY IMPROVEMENTS (I.E. PARTITIONS, DOORS, FRAMES, CABINETS, CEILING GRID, CEILING TILE, AND THE ELECTRICAL AND MECHANICAL DEVICES, ETC.) WHICH ARE TO REMAIN, ARE PROTECTED FROM DAMAGE OF ANY KIND. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING WORK WHICH IS TO REMAIN, AND DETERMINING WHETHER OR NOT IT CAN BE REPAIRED AND/OR RECONDITIONED TO MATCH AND BLEND WITH NEW MATERIALS AND COMPONENTS. THEY SHALL OBTAIN THE OWNER'S APPROVAL OF THE SCOPE AND LIMIT OF SAID WORK PRIOR TO STARTING CONSTRUCTION AND RECOMMEND AN ALLOWANCE IF NECESSARY. NO CHANGE ORDERS SHALL BE ACCEPTED FOR COMPLETED WORK THAT DOES NOT CONFORM TO THE STANDARDS ESTABLISHED AT THE TIME OF BID ACCEPTANCE. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH THE PROJECT SCOPE OF WORK, BUILDING STANDARDS, SCHEDULE AND DEADLINES. THE CONTRACTOR SHALL FURTHER BE RESPONSIBLE FOR ADVISING THE OWNER OF ALL LONG LEAD TIME ITEMS AFFECTING THE PROJECT SCHEDULE AND SHALL, UPON REQUEST FROM THE OWNER, SUBMIT ORDER CONFIRMATIONS AND DELIVERY DATES FOR SUCH LONG LEAD TIME ITEMS TO THE OWNER. 8. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER ACCESS TO THE SPACE AND THE ONGOING CONSTRUCTION WORK. DISRUPTIVE OR POTENTIALLY HAZARDOUS CONSTRUCTION ACTIVITIES OCCURRING WITHIN OR ADJACENT TO OCCUPIED SPACE SHALL BE COORDINATED TO OCCUR AFTER NORMAL OFFICE HOURS, SO AS TO MINIMIZE DISTURBANCE TO BUILDING OCCUPANTS. 9. THE CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR DELIVERY TO THE SPACE OF ALL BUILDING MATERIALS, AND SHALL ARRANGE FOR USAGE OF THE FREIGHT ELEVATOR (OR SUCH ELEVATOR DESIGNATED IF APPLICABLE). IF DELIVERY OF BUILDING MATERIALS INVOLVES THE USE OF OTHER FACILITIES, THE CONTRACTOR SHALL COORDINATE SUCH ACTIVITIES IN SUCH A MANNER WHICH POSES NO HAZARD TO ANY PERSONNEL WITHIN OR AROUND THE BUILDING OR BUILDING SITE. 10. ALL CONTRACTOR OR SUPPLIER REQUESTS FOR SUBSTITUTIONS OF SPECIFIED ITEMS SHALL BE SUBMITTED IN WRITING ACCOMPANIED BY THE ALTERNATIVE PRODUCT INFORMATION TO THE ARCHITECT. ALL SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT, NO LATER THAN (10) WORKING DAYS PRIOR TO BID OPENING DATE. SUBSTITUTIONS SHALL ONLY BE CONSIDERED IF THEY DO NOT SACRIFICE QUALITY, APPEARANCE, AND FUNCTION. UNDER NO CIRCUMSTANCES WILL THE OWNER BE REQUIRED TO PROVE THAT A PRODUCT PROPOSED FOR SUBSTITUTION IS OR IS NOT EQUAL QUALITY TO THE PRODUCT SPECIFIED. 11. UNDER NO CIRCUMSTANCES SHALL THE CONTRACTOR SCALE THE DRAWINGS TO DETERMINE THE DIMENSIONS. SEE FLOOR PLAN FOR DIMENSION LOCATIONS. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF ALL SELECTED MATERIALS WHICH SHALL BE COMPLETE IN ALL RESPECTS PRIOR TO THE FINAL ACCEPTANCE, UNLESS OTHERWISE NOTED. 13. THE CONTRACTOR SHALL BE PRESERVE ALL PRINTED INSTRUCTIONS AND WARRANTIES THAT ARE PROVIDED WITH EQUIPMENT OR MATERIALS USED, AND DELIVER SAID IN PRINTED MANNER TO THE OWNER AT THE TIME(S) DESIGNATED FOR O & M MANUAL DISBURSEMENTS. THE CONTRACTOR SHALL INSTRUCT THE OWNER OR OWNERS REPRESENTATIVE IN THE PROPER USE OF THE EQUIPMENT FURNISHED BY THEIR TRADE. 14. GENERAL CONTRACTOR IS TO PROVIDE A THOROUGH CONSTRUCTION CLEAN-UP AT CLOSE-OUT, INCLUDING VACUUMING AND CLEANING ALL CARPETING. 15. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF CUSTOM MILLWORK, CUSTOM FABRICATION OR MANUFACTURE, AND PHYSICAL SAMPLES OF ALL FINISH MATERIALS SPECIFIED TO THE ARCHITECT FOR REVIEW AND APPROVAL BY THE OWNER. SEE SPECIFICATIONS. 16. REVIEWED SHOP DRAWINGS AND SCHEDULES PREPARED BY OTHERS SHALL NOT BE CONSTRUED TO BE PART OF THE CONTRACT DOCUMENTS, AS THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR DRAWINGS, SCHEDULES, AND/OR SPECIFICATIONS FOR WORK ON THE PROJECT PREPARED OR ACCOMPLISHED BY OTHERS. 17. THE ARCHITECT WILL REVIEW THE DRAWINGS AND SAMPLES SUBMITTED BY THE CONTRACTOR (FOLLOWING A REVIEW BY THE GENERAL CONTRACTOR) FOR CONFORMITY WITH THE INFORMATION CONTAINED IN THE CONSTRUCTION DOCUMENTS. 18. CONTRACTOR TO FOLLOW ALL BUILDING STANDARDS, INTERIM LIFE SAFETY MEASURES AND COORDINATE SCHEDULING OF WORK WITH AFFECTED OCCUPANTS (IF APPLICABLE) PRIOR TO STARTING. 19. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND NOTIFY ARCHITECT, IN WRITING, OF ALL DISCREPANCIES. CONTRACTOR TO REVIEW AND RECORD EXISTING CEILING FIELD CONDITIONS, LIGHT FIXTURE AND MEP SUPPLY/RETURN LOCATIONS, SPRINKLER HEADS, AND ALL OTHER CEILING ITEMS LOCATIONS PRIOR TO CONSTRUCTION. DISCREPANCIES IN THIS INFORMATION SHALL BE RECORDED IN THE CONSTRUCTION FIELD SET. 20. THE GENERAL CONTRACTOR AND EACH TRADE IS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW WORK WITH ALL EXISTING CONDITIONS AND WITH ALL OTHER TRADES. 21. ALL CONSTRUCTION TO MEET CURRENT NATIONAL, STATE AND LOCAL CODES, ORDINANCES AND ADA REGULATIONS. 22. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERING FINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SAND ALL NEW TO EXISTING TRANSITIONS SMOOTH PRIOR TO PAINTING. PATCH ALL AREAS WHERE RECEPTACLE OR FIXTURES ARE REMOVED. REMOVE EMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC. PRIOR TO PAINTING AND REINSTALL WHEN COMPLETE. 23. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES TO SUPPLY AND INSTALL COMPLETE, FOLLOWING MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND SUPPLYING AND INSTALLING ALL ASSOCIATED ITEMS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 24. GENERAL CONTRACTOR SHALL ACCOMMODATE TENANTS VENDORS DURING CONSTRUCTION AND WORK WITH THE OWNER TO SCHEDULE INSTALLATION OF OWNER SUPPLIED AND INSTALLED ITEMS. 25. WHERE RATED WALLS ARE INDICATED, ENTIRE WALL ASSEMBLY SHALL BE CONTINUOUS AS SHOWN OR IMPLIED ON THE CONTRACT DOCUMENTS. 26. WHERE GAUGE OF METAL STUDS ARE NOT SPECIFICALLY SHOWN OR NOTED, PROVIDE GAUGE AS INDICATED IN THE GENERAL WALL TYPE NOTES. 27. CONTRACTOR TO REVISE, ADD OR RELOCATE FIRE STROBES, SPRINKLERS, AND OTHER LIFE SAFETY DEVICES AS NECESSARY TO MEET ALL APPLICABLE CODES, MAINTAIN LIFE SAFETY AND/OR AS STIPULATED BY THE CONTRACT DOCUMENTS. 28. COMMENCEMENT OF WORK BY A CONTRACTOR OR SUBCONTRACTOR, CONSTITUTES ACCEPTANCE OF THE CONDITIONS AND SURFACES IN QUESTION. IF ANY SUCH CONDITIONS/SURFACES ARE UNACCEPTABLE, THE GENERAL CONTRACTOR SHOULD BE NOTIFIED AT ONCE BY THE SUBCONTRACTOR AND NO WORK DONE UNTIL CONDITIONS ARE ACCEPTABLE. 29. CONTRACTORS ARE TO FOLLOW ALL MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION OF EQUIPMENT, MATERIALS, AND FINISHES. 31. CONTRACTOR TO PROVIDE DUST WALLS AT NECESSARY LOCATIONS. 32. TRANSPORT OF MATERIALS AND DEBRIS SHALL BE COORDINATED WITH THE FACILITY'S REPRESENTATIVES PRIOR TO THE START OF CONSTRUCTION. 33. CONTRACTOR TO MAINTAIN ALL MCOR REQUIREMENTS INCLUDING NEGATIVE AIR PRESSURE, ANTE ROOMS, AND WALK-OFF MATS. 34. CONTRACTOR TO PROVIDE AND MAINTAIN INFECTION CONTROL REQUIREMENTS PER FACILITY'S INFECTION CONTROL PRACTITIONER. GENERAL NOTES 1. CONTRACTOR TO VISIT SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO START OF WORK. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AND NOTIFY ARCHITECT, IN WRITING, OF ALL DISCREPANCIES. CONTRACTOR TO DOCUMENT EXISTING FIELD CONDITIONS, LIGHT FIXTURE AND MEP SUPPLY/RETURN LOCATIONS, SPRINKLER HEADS, AND ALL OTHER CEILING ITEM LOCATIONS PRIOR TO CONSTRUCTION. THIS INFORMATION SHALL BE PROVIDED TO ARCHITECT FOR INCORPORATION INTO A CONSTRUCTION SET. 2. THE GENERAL CONTRACTOR AND EACH TRADE IS RESPONSIBLE FOR REVIEWING AND COORDINATING ALL NEW WORK WITH ALL EXISTING CONDITIONS AND WITH ALL OTHER TRADES. 3. CONTRACTOR IS RESPONSIBLE TO PATCH/REPAIR/SEAL ALL NEW & EXISTING PENETRATIONS INTO RATED WALLS TO MAINTAIN RATED ASSEMBLY. 4. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALL BE SLEEVED AND FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. 5. UNLESS NOTED OTHERWISE, THE TERM "PROVIDE" INDICATES TO SUPPLY AND INSTALL COMPLETE, FOLLOWING MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS AND SUPPLYING AND INSTALLING ALL ASSOCIATED ITEMS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 6. GENERAL CONTRACTOR SHALL COORDINATE ALL PHASES AND TIMING OF CONSTRUCTION WITH ARCHITECT, TENANT, AND BUILDING OWNER. 7. ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES, UTILITIES, AND STRUCTURES WITHIN THE WORK ZONE AND OR WITHIN THE PATH ESTABLISHED BY THE CONTRACTOR TO EXECUTE THE WORK SHALL BE INCORPORATED IN THE CONTRACTOR'S BASE BID. FIELD VERIFICATION PRIOR TO BID THE CONTRACTOR AND HIS SUBCONTRACTORS ARE REQUIRED TO VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO THE ISSUANCE OF A BID. ALL COSTS ASSOCIATED WITH THE PROTECTION OF EXISTING FACILITIES, UTILITIES, AND STRUCTURES (BOTH ABOVE AND BELOW GRADE AND AREA OF WORK) WITHIN THE WORK ZONE AND OR WITHIN THE PATH ESTABLISHED BY THE CONTRACTOR TO EXECUTE THE WORK SHALL BE INCORPORATED IN THE CONTRACTORS BASE BID. THE CONTRACTOR SHALL NOTIFY OWNER/DESIGN PROFESSIONAL (PRIOR TO BID) OF ANY ITEMS DISCOVERED DURING FIELD VERIFICATION THAT THE CONTRACTOR FEELS REQUIRE ADDITIONAL CLARIFICATION FROM THE OWNER/DESIGN PROFESSIONAL IN ORDER TO APPROPRIATELY BID THE PROJECT. ABBREVIATIONS LAV LAVATORY MAS MASONRY MAX MAXIMUM MB MARKER BOARD MECH MECHANICAL MEZZ MEZZANINE MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING O.D. OUTSIDE DIAMETER O.H. OPPOSITE HAND OH OVERHEAD OPNG OPENING OPP OPPOSITE P LAM PLASTIC LAMINATE PLWD PLYWOOD QT QUARRY TILE R RISER R.O. ROUGH OPENING RA RETURN AIR REF REFERENCE REQ REQUIRED SA SUPPLY AIR SCH SCHEDULE SEC SECTION SF SQUARE FOOT SIM SIMILAR SPECS SPECIFICATIONS SS STAINLESS STEEL STD STANDARD STL STEEL SUSP SUSPENDED T.B.D. TO BE DETERMINED T.O. TOP OF TEL TELEPHONE TV TELEVISION TYP TYPICAL U.O.N. UNLESS OTHERWISE NOTED UR URINAL V.I.F. VERIFY IN FIELD VCT VINYL COMPOSITION TILE VERT VERTICAL VT VINYL TILE W/ WITH W/O WITHOUT WB WOOD BASE WC WATER CLOSET WD WOOD WH WATER HEATER WP WORKING POINT ABBREVIATIONS A.F.F. ABOVE FINISHED FLOOR ACT ACOUSTICAL CEILING TILE APP APPROXIMATE AWT ACOUSTICAL WALL TREATMENT B.O. BOTTOM OF BD BOARD BLKG BLOCKING BOT BOTTOM C.J. CONTROL JOINT CAB CABINET CL CENTER LINE CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS CPT CARPET CT CERAMIC TILE CW COLD WATER D.F. DRINKING FOUNTAIN DET DETAIL DIM DIMENSION DTL DETAIL DWC DRINKING WATER COOLER DWG DRAWING EA EACH EIFS EXTERIOR INSULATION FINISH SYSTEM EJ EXPANSION JOINT EL ELEVATION ETR EXISTING TO REMAIN EXIST EXISTING EXP EXPANSION EXT EXTERIOR FD FLOOR DRAIN FE FIRE EXTINGUISHER FIN FINISH FL FLOOR FT FEET GA GAUGE GYP GYPSUM HDW HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING, VENTILATING & AIR COND. HW HOT WATER I.D. INSIDE DIAMETER JST JOIST JT JOINT KIT KITCHEN LAM LAMINATE DRAFTING SYMBOLS # Revision Description Date Issued 06/08/21 8"MIN.9"MIN. 11"27" MIN.34" MAX.30" MIN.25" MAX. NOTES: 1. HOT WATER & DRAIN PIPES UNDER THE LAVATORY SHALL BE INSULATED OR CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE LAVATORY. 2. FAUCETS SHALL BE LEVER OPERATED, PUSH TYPE, OR ELECTRONICALLY CONTROLLED MECHANISMS. SELF-CLOSING VALVES SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. 3. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN 40" A.F.F. CLEAR FLOOR SPACE17" MIN.48" MIN.30" MIN.34" MAX.PROTECTED PIPING W/ CASWORK OF INSULATED PIPE COVER19" MAX.8" MIN. TO REFLECTIVE SURFACE40" MAX.11" MIN. 6"29" MAX.MIN.9"MIRROR 17" MIN. 19" MAX.40" MAX.NOTE: SEE SPECIFICATIONS FOR ADDITIONAL MOUNTING HEIGHTS. TELEPHONE MIRROR TO BOTTOM OFREFLECTINGSURFACEDIAPER DISPENSER OR SANITARY NAPKIN DISPENSER SOAP DISPENSER FIRE EXTINGUISHER CABINET (MAX. 4" PROJECTION)48" MAX.27" MIN.*SEE GUIDELINES FOR MOUNTING HEIGHTS AT GRAB BARS. NOTE: MOUNT ALL NON-HANDICAP ACCESSORIES ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.WHEELCHAIRACCESSIBLEELECTRIC WATER COOLER 34" MAX.SURFACE33" TO CHANGINGSTANDING HGT.38" - 43"GRAB BAR 33" - 36"ELECTRIC HAND DRYER SANITARY NAPKIN DISPOSAL* WASTE RECEPTACLE / PAPER TOWEL DISPENSER S T E 15" MIN.TO OPERABLE PARTS44" - 48"TO OPERABLE PARTS48".E 46" MAX.THERMOSTAT SWITCH ELEC. OUTLET ABOVE 25" DEEP COUNTER BABY CHANGING STATION TRANSFER SIDE FLUSH VALVE ON OPEN SIDE 33" - 36" 17" - 19"24" MIN. 12" MIN. 36" MIN. 16" - 18"33" - 36"MAX. 12" MIN. 42" 54" MIN.18" MIN. 39" - 41" 39"-41"17" - 19"AREA OF REFUGE 5' - 0" TO CENTER OF SIGNNOTE: ALL SIGNAGE SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH SIDE OF THE DOOR EXCEPT SIGNS W/ TACTILE CHARACTERS ON PUSH SIDE OF DOORS WITH CLOSERS. PICTOGRAM SIGNS SHALL BE A MIN. OF 6" HEIGHT. SEE SECTION 703 OF THE ADA. TRANSFER SIDE FLUSH VALVE ON OPEN SIDE 33" - 36"17" - 19"24" MIN. 12" MIN. 36" MIN. 16" - 18"33" - 36"MAX. 12" MIN. 42" 54" MIN.18" MIN.39" - 41" 39"-41"17" - 19"NOTE: CONTROLS & OPERATING MECHANISMS SHALL BE OPERABLE W/ ONE HAND & SHALL NOT REQ. TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LBF (22.2 N) FAUCETS LEVER-OPERATED, PUSH-TYPE & ELECTRONICALLY SHALL COMPLY WITH 4.27.4 CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF SELF-CLOSING VALVES ARE USED THE FAUCET SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS. 3' - 0" 6" 2' - 10"REAR GRAB BAR 3' - 6" 1' - 0"2' - 10"SIDE GRAB BAR 1 2A VERTICAL GRAB BAR2B GRAB BAR 2B GRAB BAR 2A 3' - 4" 1' - 6"3' - 3" TYP. & HC ROLL TOILET PAPER HOLDER (RTPH) 3 FRONT OF TOILET RTPH 7" 1' - 7"2' - 6"TYP. & HC SANITARY NAPKIN DISPOSAL (SND) 4 2' - 6"SND HC TOILET SEAT COVER DISPENSER (TSCD) 5 4' - 0" TSCD MAX. PROTRUSION 4" TYP. & HC SOAP DISPENSER (SD) 6 3' - 6"SD PAPER TOWEL DISPENSER (PTD) 7 4' - 0" PTD MAX. PROTRUSION 4" T.O. DISPENSER CONTROL60" MIN.18" FRONT APPROACH, PULL SIDE 48" MIN.12" MIN.* NOTE: * IF BOTH CLOSER AND LATCH ARE PROVIDED YX HINGE APPROACH, PUSH SIDE NOTE: X = 36" MIN. IF Y = 60"; X = 42" MIN. IF Y = 54"48" MIN.*24" MIN. NOTE: * 54" MIN. IF CLOSER IS PROVIDED 42" MIN.**12" MIN.* NOTE: * IF BOTH CLOSER AND LATCH ARE PROVIDED. ** 48" MIN. IF BOTH CLOSER AND LATCH PROVIDED 42" MIN.*24" MIN. 22" MIN. NOTE: * 48" MIN. IF CLOSER IS PROVIDED HINGE APPROACH, PULL SIDE FRONT APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE LATCH APPROACH, PULL SIDE 1 1/2"1 1/2" 2X6 ANCHORING BACK PLATE SECURE 2X6 TO 3-5/8" MTL. STUDS OR 2X WD. FRAMED STUDS SCREW 1-1/2" O.D. S.S. GRAB BAR - SEE RESTROOM FIXTURE ACCESSORIES SPECIFICATION FOR MFG. & MODEL NUMBER METAL WALL FLANGE NOTE: INSTALLATION MUST WITHSTAND 300 LBS. DOWNWARD PULL. VERTICAL SECTION PLAN VIEW 1-1/2" O.D. S.S. GRAB BAR - SEE RESTROOM FIXTURE ACCESSORIES SPECIFICATION FOR MFG. & MODEL NUMBER SCREW METAL WALL FLANGE 2X6 ANCHORING BACK PLATE SECURE 2X6 TO 3-5/8" MTL. STUDS OR 2X WD. FRAMED STUDS 60" MIN.56" MIN.OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 ACCESSIBILITY GUIDELINES 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 462901/2" = 1'-0"A002 ADA KNEE & TOE CLEARANCE16A 1/2" = 1'-0"A002 ADA LAVATORY11E 12" = 1'-0"A002 ADA MOUNTING HEIGHTS4D 1/2" = 1'-0"A002 ADA REAR WALL GRAB BARS @ TOILET12D 1/2" = 1'-0" A002 ADA SIDE WALL GRAB BARS @ TOILET1 1D 3/4" = 1'-0"A002 ADA SIGNAGE16C1/2" = 1'-0"A002 ADA TOILET FIXTURES11C 1/2" = 1'-0" A002 ADA WASHROOM ACCESSORIES13E 12" = 1'-0"A002 ADA APPROACH LEGEND4C 1 1/2" = 1'-0" A002 ADA GRAB BAR - PLAN/SECTION1 4A 1/4" = 1'-0" A002 TOILET FIXTURE CLEARANCE 2A # Revision Description Date Issued 06/08/21 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 GENERAL SPECIFICATIONS10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290INSTRUCTIONS GENERAL REQUIREMENTS - SUMMARY OF WORK ALL SUBSTITUTION FOR SPECIFIED PRODUCTS SHALL BE BY WRITTEN APPROVAL OF THE ARCHITECT. BIDDING PROCEDURE AND CONSIDERATION OF BIDS SHALL BE PROVIDED BY THE PROJECT MANAGER. STUDIO 3 DESIGN TO PROVIDE ADDITIONAL INSTRUCTIONS. THE PROJECT CONSISTS OF AN INTERIOR CLINIC RENOVATION. CONSTRUCTION ACTIVITIES AND OPERATIONS SHALL BE LIMITED TO THE PROJECT AREA INDICATED ON THE DRAWINGS. PORTIONS OF THE SITE BEYOND AREAS IN WHICH CONSTRUCTION OPERATIONS ARE INDICATED ARE NOT TO BE DISTURBED. ACCESS TO SITE IS TO BE AVAILABLE TO PM/ARCHITECT AT ALL TIMES. THE INTENT IS FOR A COMPLETE AND FINISHED JOB. SOME FINISHES MAY HAVE TO OCCUR BEYOND THE LIMITS DEFINED IN THE DRAWINGS TO PROVIDE A COMPLETE PRODUCT. GENERAL CONSTRUCTION SPECIFICATIONS THESE SPECIFICATIONS COVER CERTAIN PARTS OF THE GENERAL CONSTRUCTION PORTION OF THE PROJECT AS DESIGNED BY STUDIO 3 DESIGN, 8604 ALLISONVILLE ROAD SUITE 330, INDIANAPOLIS, IN 46250. INCLUDED IN THE SCOPE OF WORK COVERED BY THESE DRAWINGS AND SPECIFICATIONS IS THE BUILD OUT OF HANCOCK REGIONAL HOSPITAL PARKWAY MEDICAL CENTER BLOOD LAB AND IMAGING SUITE RENOVATIONS. THE PROJECT GENERAL CONTRACTOR IS PEPPER CONSTRUCTION. INVITATION TO BID WILL BE PERFORMED BY THE PROJECT MANAGER. CONTRACT REQUIREMENTS THE CONTRACT DOCUMENTS INDICATE THE GENERAL ARRANGEMENT AND SCOPE AND IF ANY DEVIATIONS ARE NECESSARY, SUCH DEVIATIONS SHALL BE MADE IN WRITING TO THE ARCHITECT FOR APPROVAL. THE ARCHITECT RESERVES THE RIGHT TO MAKE MINOR CHANGES (MAX 10'-0") IN LOCATION OF DEVICE SYSTEMS OR EQUIPMENT. ALL WORK MUST BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL LAWS, ORDINANCES, AND RULES DEALING WITH THE WORK. ALL SUCH LAWS, ORDINANCES, AND RULES ARE HEREBY MADE A PART OF THIS SPECIFICATION BY REFERENCE. CONSTRUCTION SCHEDULE INFORMATION TO BE PROVIDED BY GENERAL CONTRACTOR IN TANDEM WITH STUDIO 3 DESIGN. OPERATING AND MAINTENANCE MANUAL FURNISH OPERATING AND MAINTENANCE MANUAL FOR ALL EQUIPMENT, MATERIALS, AND SYSTEMS INSTALLED IN A 3 RINGED HARD BACK LOOSE LEAF BINDER. CONTENTS 1. VENDORS AND LISTING INCLUDING NAMES, ADDRESSES AND PHONE 2. MANUFACTURERS PUBLISHED LITERATURE 3. LISTS AND LOCATIONS OF CIRCUITS, VALVES, DAMPERS, ETC. 4. INDEX 5. INSTRUCTIONS ON OPERATIONS AND MAINTENANCE 6. REPLACEMENT PART INFORMATION 7. GUARANTEES AND WARRANTIES ISSUED 8. SHOP DRAWINGS SCHEDULE OF VALUES INFORMATION TO BE PROVIDED BY CONTRACTOR. PROJECT CLOSE OUT WHEN THE CONTRACTOR CONSIDERS THE WORK SUBSTANTIALLY COMPLETE, THEY SHALL SEND STUDIO 3 DESIGN AND THE OWNER NOTICE OF SUBSTANTIAL COMPLETION. ATTACH TO THE NOTICE THE CONTRACTOR PUNCH LIST. UPON RECEIPT THE ARCHITECT SHALL SCHEDULE A PRELIMINARY INSPECTION. AFTER UNACCEPTABLE OF INCOMPLETE WORK HAS BEEN CORRECTED CONTRACTOR SHALL NOTIFY ARCHITECT WHO WILL SCHEDULE A FINAL INSPECTION. SHOULD THE ARCHITECT DETERMINE THE WORK IS SUBSTANTIALLY COMPLETE A CERTIFICATE OF SUBSTANTIAL COMPLETION. THE OWNER MAY ASSUME OCCUPANCY UPON RECEIPT OF CERTIFICATE OF SUBSTANTIAL COMPLETION. CUTTING AND PATCHING PROVIDE LABOR AND MATERIAL TO CUT AND PATCH AS SHOWN OR IMPLIED ON DRAWINGS. OPENINGS MADE IN EXISTING CONCRETE CONSTRUCTION FLOOR INSTALLATIONS OF NEW PIPING, ETC, SHALL BE DIAMOND CUT. RESTORE WORK WHICH HAS BEEN CUT OR REMOVED AND INSTALL NEW PRODUCTS TO PROVIDE COMPLETED WORK. REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH. CLEANING PROVIDE ALL REQUIRED PERSONNEL EQUIPMENT AND MATERIAL NECESSARY TO MAINTAIN THE SPECIFIED STANDARD OF CLEANLINESS, WEEKLY, AND MORE OFTEN IF NECESSARY INSPECT AND PICK UP SCRAP, DEBRIS, AND WASTE MATERIAL. DUST CONTROLS MUST BE MAINTAINED THROUGHOUT CONSTRUCTION. SWEEP ALL INTERIOR SPACES. CLEAN IMMEDIATELY PRIOR TO THE DATE SET FOR THE ARCHITECT'S PRELIMINARY INSPECTION. REMOVE ALL DEBRIS, VACUUM ALL FLOORS AND LEAVE OTHER SURFACES DUST FREE AND CLEAN. FINAL CLEANING, CONTRACTOR SHALL PROVIDE A LEVEL OF CLEANLINESS GENERAL PROVIDED BY COMMERCIAL BUILDING MAINTENANCE SUBCONTRACTORS. CAST-IN-PLACE CONCRETE CONCRETE WORK SHALL CONFORM TO THE FOLLOWING CODES, SPECIFICATIONS AND STANDARDS. · ACI 301 "Specifications for Structural Concrete". · ACI 318 "Building Code Requirements for Structural Concrete". · Concrete Reinforcing Steel Institute (CRSI), "Manual of Standard Practice". · ACI 311 "Standard Specifications for Tolerances for Concrete Construction and Materials". · Portland Cement Association "Positioning Welded Wire Fabric". · ASTM C1116, Type III "Standard Specifications for Fiber-Reinforced Concrete and Shotcrete". THE FOLLOWING ITEMS ARE ADDITIONS AND/OR MODIFICATIONS TO THE CODES, SPECIFICATIONS AND STANDARDS NOTED ABOVE. CONCRETE FOR SLABS TO BE 3500 PSI, FOUNDATIONS AND OTHER WORK SHALL BE MINIMUM 3,000 PSI AT 28 DAY TEST WITH 4 INCH MAXIMUM SLUMP. CONCRETE FOR EXTERIOR WALLS AND FLAT WORK SHALL BE MINIMUM 4,000 PSI AT 28 DAY TEST WITH 4 INCH MAXIMUM SLUMP AND 6% AIR-ENTRAINMENT, PLUS OR MINUS 1% CEMENT FOR ALL CONCRETE SHALL BE TYPE I, MAXIMUM COURSE AGGREGATE SIZE SHALL BE 1 INCH. EXCEPT FOR AIR-ENTRAINMENT, ADMIXTURES SHALL NOT BE USED. PROVIDE THE MINIMUM THICKNESS OF COMPACTED GRANULAR FILL SHOWN ON THE DRAWINGS UNDER ALL INTERIOR FLOOR SLABS PLACED ON GRADE. FILL SHALL BE COMPACTED TO 95% OF ITS MAXIMUM DENSITY AT OPTIMUM MOISTURE CONTENT, AS DETERMINED BY THE MODIFIED PROCTOR TEST, ASTM D-1557. ALL GRANULAR FILL MATERIAL PLACED UNDER FLOOR SLABS SHALL BE GOOD, CLEAN MATERIAL WITH LESS THAN 5% PASSING A 200 SIEVE . A 6 MIL POLYETHYLENE VAPOR BARRIER SHALL BE PLACED ON TOP OF THE GRANULAR FILL IN ALL INTERIOR SLAB AREAS. LAPS SHALL BE A MINIMUM OF 6 INCHES. TURN UP VAPOR BARRIER AT ALL VERTICAL SURFACES. ELECTRICAL CONDUITS OR OTHER UNDERFLOOR PIPES, DUCTS OR RACEWAYS SHALL BE PLACED WITHIN THE GRANULAR FILL SUCH THAT A MINIMUM 2 INCH DEEP COVER IS PROVIDED. REINFORCING STEEL SHALL CONFORM TO ASTM A-615, GRADE 60. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 1064 AND SHALL BE PLACED IN ALL SLABS, EXTENDING THROUGH ALL CONSTRUCTION AND CONTROL JOINTS UNLESS OTHERWISE SHOWN. NYCON IS AN APPROVED EQUIVALENT. EXPANSION MATERIALS SHALL BE NON-EXTRUDING TYPE FOR ALL INTERIOR AND EXTERIOR WORK, 1/2 INCH THICK X WIDTH REQUIRED, AGAINST ALL VERTICAL SURFACES AND WHERE OTHERWISE SHOWN. CONSTRUCTION JOINTS IN SLABS SHALL BE OF 24 GAUGE GALVANIZED STEEL WITH KEY WAY, INSTALLED FOR PERMANENT INSTALLATION. AN EQUIVALENT TO A FORMED KEY WAY SHALL BE # 4 SMOOTH DOWELS, 12" LONG, AT 24' ON CENTER. CONTROL JOINTS IN SLABS SHALL BE A CONTINUOUS 1/8 INCH WIDE X 1 INCH DEEP CONTINUOUS SAW CUT. THICKEN SLABS AT ALL CONTROL JOINTS. INTERIOR AND EXTERIOR FLAT WORK SHALL BE CURED USING A COMPOUND EQUAL TO SONNEBORN "KURE-N-SEAL", COMPATIBLE WITH FINISH MATERIALS APPLIED TO FINISHED FLOOR SLABS. APPLY CURING COMPOUND IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. INTERIOR FLAT WORK SHALL RECEIVE STEEL TROWEL FINISH, EXTERIOR FLAT WORK SHALL RECEIVE A LIGHT BROOM FINISH. METAL SCREW TYPE STUDS FOR INTERIOR WALLS SHALL BE AS SHOWN ON PLANS X 25 GAUGE STUDS AT 16 OR 24 INCHES ON CENTER, AS SHOWN. STANDARD FLOOR AND CEILING TRACKS SHALL BE USED. WALLS SHALL BE BRACED AS REQUIRED OR SHOWN TO MAINTAIN STRAIGHTNESS. PROVIDE ALL MISCELLANEOUS STEEL SHOWN ON THE DRAWINGS FOR INJECTOR SUPPORT. INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND ALL APPLICABLE CODES. METALS CONSTRUCTION LUMBER SHALL BE EQUAL TO DOUGLAS FIR, OR #2 HEM FIR KILN DRIED TO A MOISTURE CONTENT OF 19% OR LESS, DRESSED LUMBER SHALL BE RED OAK, POPLAR, CLEAR WHITE PINE OR BIRCH, KILN DRIED TO A MOISTURE CONTENT OF 15% OR LESS AND FIRE TREATED. LUMBAR USED FOR BLOCKING, CURBS, CANTS, ETC., SHALL BE FIRE TREATED OR WHERE IN CONTACT WITH THE ELEMENTS SHALL BE EQUAL TO #2 SOUTHERN PINE (15% MOISTURE CONTENT) PRESERVATIVE TREATED. PLYWOOD FOR BLOCKING SHALL BE FIRE RETARDANT TREATED C-C INT APA WITH EXTERIOR GLUE OR OTHER MISCELLANEOUS FASTENINGS. PROVIDE BLOCKING AS REQUIRED IN WALL, PARTITIONS, ETC., TO RECEIVE HARDWARE, OR OTHER MISCELLANEOUS FASTENINGS. MILLWORK TO COMPLY WITH ALL PERTINENT CODES AND REGULATIONS, ALSO COMPLY WITH "ARCHITECTURAL WOODWORK QUALITY STANDARDS, GUIDE SPECIFICATION AND QUALITY CERTIFICATION PROGRAM" PUBLISHED BY THE ARCHITECTURAL WOODWORK INSTITUTE. ALL INTERIOR WORK SHALL CONFORM TO PREMIUM GRADE. INTERIOR AWI QUALITY GRADE: PREMIUM GRADE FOR TRANSPARENT FINISH, EXTERIOR: AWI QUALITY GRADE: ECONOMY GRADE FOR OPAQUE FINISH. CUSTOM CASEWORK SHALL BE FABRICATED IN ACCORDANCE WITH ARCHITECTURAL WOODWORKING INSTITUTE'S PREMIUM GRADE QUALITY STANDARD. CONTRACTOR SHALL COORDINATE LOCATION OF BLOCKING BEHIND ALL CASEWORK MOUNTING. IT IS SUBCONTRACTOR'S RESPONSIBILITY TO FIELD MEASURE TO ASSURE PROPER FIT. FINISH AS NOTED IN MATERIALS LIST. GENERAL PURPOSE-150 GRADE 10/HGS, .048" THICKNESS. VERTICAL SURFACING- 150 GRADE 55/VGS .048" THICKNESS. CABINET LINER TO BE 150 GRADE 72/CLS: .02" THICKNESS. CORE BOARD SHALL BE 3/4" THREE-PLY, FINE-SURFACED, MEDIUM-DENSITY FIBER BOARD. BACK AND DRAWER BOTTOM TO 1/4", SHELVES OVER 36" TO BE 1" FLUSH OVER LAY DESIGN. COLORS AS SPECIFIED IN MATERIALS LIST. HARDWARE- HEAVY DUTY INSTITUTIONAL QUALITY 1. DRAWER SLIDES: ACCURIDE 3832 2. FILE DRAWER SLIDES ACCURIDE 3640 3. KEYBOARD SLIDES ACCURIDE 2009 4. SHELF STANDARDS HAFELE "EX-CELLENT H" #282.23.725- CABINET MOUNTED 5. SHELF STANDARDS K&V 186ANO OR 187ANO- 87 STANDARDS- WALL MOUNT 6. GROMMETS HAFELE 429.99.32 7. HINGES, CONCEALED GRASS 3900 SERIES 8. PULLS, BAR 9. CATCH, MAGNETIC STANLEY SP46 10. CATCH, SPRING HAFELE 245.55.913 11. BRACKET, COUNTER STANLEY 796 12. CLOTHES ROD K&V 7705 AND 764 CHR FLANGES TWO HINGES PER DOOR UP TO 35 1/2" H THREE HINGES PER DOOR 35 1/2" H TO 63" H CARPENTRY FIBERGLASS WALL INSULATION SHALL BE 3-5/8" (R-11) THICK BATTS AS SHOWN, UNFACED FRICTION-FIT, SOUND BATTS. CONSULT ARCHITECT FOR ALL OTHER WALL SIZES. THERMAL PROTECTION GYPSUM WALLBOARD SHALL BE EQUAL TO USG "SHEET ROCK", 48" WIDE X THICKNESS, FIRE RATING, AND LEAD BACKED AS SHOWN, WITH TAPERED EDGES. USE WALLBOARD OF MAXIMUM LENGTH TO MINIMIZE END JOINTS. END JOINTS SHALL OCCUR OVER STUDS OR BLOCKING. APPLY WALLBOARD WITH LENGTH OF BOARDS HORIZONTAL. APPLY JOINT TAPE AND SPACKLING COMPOUND IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. SAND JOINTS SMOOTH SURROUNDING WALLBOARD SURFACE. SCREW GYPSUM WALLBOARD TO STUDS OR OTHER FRAMING MEMBERS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. JOINT CEMENT AND REINFORCING TAPE SHALL BE MANUFACTURER'S STANDARD. METAL TRIM SHALL BE EQUAL TO USG METAL TRIM AS NOTED BELOW: CORNER BEAD: USG "DUR-A-BEAD" METAL TRIM (SPACKLE-IN TYPE): USG #200-B METAL TRIM (J-MOULD TYPE): USG #400 CONTROL JOINT: USG #1093 AT 32 FEET ON CENTER MAX. GYPSUM WALL BOARD MEET REQUIREMENTS OF ASTM E-814-13a THROUGH PENETRATION FIRE TEST BY A NATIONALLY RECOGNIZED TESTING AGENCY. INSTALLER SHALL SPECIALIZE IN FIRE STOPPING WITH NO LESS THAN ONE YEAR EXPERIENCE AND APPROVED BY THE MANUFACTURER. WORK SHALL BE COORDINATED WITH ALL OTHER TRADES. CONTRACTOR TO VERIFY OWNER'S SYSTEM PREFERENCE PRIOR TO RELEASING CONTRACTS. ACCEPTABLE MANUFACTURERS: A. PENETRATION SEALANTS 1. DOW CORNING FIRE STOP FOAM AND FIRE STOP SEALANT 2. 3M BRAND FIRE BARRIER CAULK 3. HILTI FIRESTOPP MATERIALS B. INTUMESCENT SEALANTS 1. DOW CORNING FIRE STOP INTUMESCENT WRAP STRIP 2. 3M BRAND FIRE CAULK 3. HILTI INTUMESCENT FIREPROOFING FIRE STOPPING HOLLOW METAL FRAMES SHALL BE COLD ROLLED STEEL, OF GAUGES LISTED, HAVING ADJUSTABLE BASE ANCHORS AND THREE STUD ANCHORS PER JAMB. FRAMES SHALL BE MORTISED AND REINFORCED TO RECEIVE REQUIRED HARDWARE. STRIKE JAMBS SHALL HAVE THREE RUBBER SILENCERS. FRAMES SHALL BE BONDERIZED AND SHALL RECEIVE ONE SHOP COAT OF PRIMER. INTERIOR FRAMES: 18 GAUGE EXTERIOR FRAMES: 16 GAUGE HOLLOW METAL KNOCK DOWN FRAMES WILL BE ACCEPTABLE WHERE SHOWN ON DRAWINGS. DOOR HARDWARE, SPECIALTY DOORS AND OVERHEAD DOORS SHALL BE AS SPECIFIED ON DRAWINGS. HOLLOW METAL DOORS AND FRAMES FLUSH INTERIOR WOOD DOORS TO BE EQUAL TO MASONITE ASPIRO SERIES SELECT WOOD VENEER (5-PLY CONSTRUCTION): PREMIUM SELECT VENEER, WITH HARDWOOD VENEER CROSSBAND. HARDWOOD TOP, SIDE AND BOTTOM EDGES TO MATCH FACE VENEER. OPENINGS FOR LOUVERS OR GLASS LIGHTS SHALL BE SHOP MADE: USE WOOD MOLDINGS FOR GLASS LIGHT FRAMES. FACTORY OR FIELD FINISH SATIN TOPCOAT PER THE MATERIALS LIST. PROVIDE WARRANTY AGAINST WARPING OR TELEGRAPHING OF CORE CONSTRUCTION FOR THE LIFE OF THE INSTALLATION. PRE-FINISHED DOORS MAY BE APPROVED EQUAL. SUBMIT COLOR SAMPLE TO ARCHITECT. SEE MATERIALS LIST AND DOOR SCHEDULE FOR VENEER AND FINISH SELECTIONS. FLUSH WOOD DOORS COORDINATE THE FURNISHING AND INSTALLATION OF ALL HARDWARE ITEMS WITH DOORS, FRAMES, AND OTHER RELATED ITEMS TO DETERMINE THE SUITABILITY OF ALL SPECIFIED HARDWARE. ALL HARDWARE SHALL MEET FEDERAL, STATE AND LOCAL CODES. ANY HARDWARE PROVIDED THAT IS NOT IN CONFORMANCE WITH THE CODES SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER. FINISHES SHALL BE US26D DULL CHROME UNLESS OTHERWISE NOTED. FINISH HARDWARE HARDWARE STANDARDS - U.N.O. 1. BUTTS & HINGES: HAGER, MCKINNEY, STANLEY A. CONTINUOUS HINGES: PEMKO 2. LOCK SETS: BEST 3. CYLINDERS: BEST, SCHLAGE 4. HOSPITAL LATCHES: GLYNN JOHNSON, SERGEANT 5. ROLLER LATCHED: GLYNN JOHNSON 6. FLUSH BOLTS: HAGER, IVES, ROCKWOOD 7. PANIC EXIT DEVICES: VONDUPRIN, SERGEANT 8. CLOSERS & LIFE SAFETY HARDWARE: LCN, STANLEY 9. PULLS & PUSH PLATES: FORMS & SURFACES 10. ASTRAGALS: NATIONAL GUARD, PEMKO 11. DOOR ARMOR (PLASTIC): CONSTRICTION SPECIALTIES 12. DOOR ARMOR (STAINLESS): HAGER 13. STOPS: HAGER, HIAWATHA, IVES 14. COORDINATOR: DOOR CONTROL INTERNATIONAL 15. ELECTRONIC DOOR HOLDER: RIXON 16. SILENCERS: GLYNN JOHNSON 17. SLIDING DOOR LOCK: ADAMS RITE 18. THRESHOLDS: NATIONAL GUARD, PEMKO 19. WEATHER STRIPPING: NATIONAL GUARD, PEMKO 20. SWEEPS: NATIONAL GUARD,PEMKO 21. PIVOT HINGES: RIXON, MCKINNEY, STANLEY 22. FLOOR CLOSER/PIVOTS: RIXON 23. WALL TYPE HOLDER: MODRIC 24. ELECTROMAGNETIC LOCK: SARGENT 25. SMOKE SEAL: PEMKO 26. AUTOMATIC DOOR BOTTOMS: NATIONAL GUARD 27. ELECTROMAGNETIC HOLD OPEN: SARGENT EXCEPT WHERE LABEL PROVISIONS REQUIRE LARGER OR HEAVIER HINGES OR WHERE SPECIFIED OTHERWISE HEREIN. PROVIDE HINGES OF THE FOLLOWING SIZES AND WEIGHTS: 1. DOORS LESS THAN 3'-6" WIDE: 3 PAIR 4-1/2" X 4-1/2" OR CONTINUOUS (STANDARD) 2. DOORS 3'-6" WIDE TO 4'-0" WIDE: 3 PAIR 5" X 4-1/2" OR CONTINUOUS (EXTRA HEAVY) 3. DOORS 5'-0" HIGH AND NOT OVER 7'-6" HIGH: 1-1/2 PAIR OR CONTINUOUS 4. DOORS 7'-6" HIGH AND NOT OVER 10'-0" HIGH: 2 PAIR OR CONTINUOUS 5. AUTOMATIC DOORS: 5" X 4-1/2" (2 PAIR) OR CONTINUOUS COORDINATION OF KEYS AND KEYING: 1. ALL LOCKS SHALL BE KEYED, MASTER KEYED, AND GRAND MASTER KEYED. AFTER AWARD OF CONTRACT, THE HARDWARE SUPPLIER SHALL CONFER WITH THE OWNER TO DETERMINE KEYING SYSTEM. SUBMIT A KEYING DIAGRAM AFTER THIS CONFERENCE. 2. SUPPLY (6) MASTER KEYS AND (3) GRAND MASTER KEYS. EACH LOCK SHALL HAVE (2) INDIVIDUAL KEYS. 3. KEYS SHALL BE STAMPED AS DIRECTED BY OWNER. 4. ALL MASTER KEYS AND GRAND MASTER KEYS SHALL BE SENT TO THE OWNER VIA REGISTERED MAIL SUPPLIER. A. BLOCKING I. COORDINATE BLOCKING IN WALL BEHIND WALL STOPS, ELECTROMAGNETIC DOOR HOLDERS. MOUNTING HEIGHTS: 1. UNLESS SPECIFIED OTHERWISE, HARDWARE MOUNTING HEIGHTS SHALL BE AS FOLLOWS, MEASURED FROM FINISHED FLOOR LINE (TO CENTER LINE OR AS STATED): A. STRIKE: 40-5/16" B. EXIT DEVICE CROSS BAR: 39-13/16" C. PUSH PLATES: 46" D. PULL: 46" 2. COMPLY WITH CURRENT STANDARDS FOR HANDICAPPED ACCESS, INCLUDING UNITED STATES ARCHITECTURAL AND TRANSPORTATION BARRIERS COMPLIANCE BOARD (A&T BCB) "MINIMUM GUIDELINES AND REQUIREMENTS FOR ACCESSIBLE DESIGN, FINAL RULE" AND ANSI A117.1 (2009). INSTALL ALL JOINT SELANTS PER MANUFACTURER'S INSTRUCITONS. EQUAL SUBSTITUTIONS ALLOWED UPON REVIEW AND APPROVAL BY ARCHITECT. SEALANT WORK SHALL BE PERFORMED BY A CONTRACTING SPECIALIZING IN PERFORMING SEALANT WORK WITH A MINIMUM OF 3 YEARS OF EXPERIENCE. TYPE A JOINTS IN CONCRETE AND TILE FLOORS AND PAVED SURFACES SUBJECT TO FOOT TRAFFIC: MULTIPLE COMPONENT, SELF-LEVELING POLYURETHANE BASED SEALANT CONFORMING TO ASTM C920, TYPE M, GRADE P, CLASS 25. A. MAMECO INTERNATIONAL “VULKEM 245”. B. SIKA CORPORATION “SIKAFLEX 2C-SL”. C. SONNEBORN BUILDING PRODUCTS “SONOLASTIC PAVING JOINT SEALANT”. D. TREMCO “THC-900”. E. PECORA CORPORATION “NR-200”. TYPE B EXTERIOR JOINTS IN MASONRY AND EIFS AND AROUND METAL DOOR, WINDOW AND LOUVER FRAMES PENETRATING THESE SURFACES. DO NOT USE SINGLE COMPONENT SEALANTS WHEN EXCESSIVE MOVEMENT IS EXPECTED WITHIN THE CURING TIME OF THE SEALANT: SINGLE OR MULTIPLE COMPONENT, NON-SAG, POLYURETHANE-BASED SEALANT CONFORMING TO ASTM C920, TYPE S OR M, GRADE NS, CLASS 25. A. MAMECO INTERNATIONAL, “VULKEM 116 OR 227”. B. SIKA CORPORATION “SIKAFLEX 1A OR 2C-NS”. C. SONNEBORN BUILDING PRODUCTS “SONOLASTIC NP I OR NP II”. D. TREMCO “DYMONIC OR DYMERIC”. E. PECORA CORPORATION “DYNATROL II”. TYPE C INTERIOR WALL PENETRATIONS FOR PIPE AND CONDUIT THAT WILL BE CONCEALED BY ESCUTCHEONS AND OTHER TRIM AND PLATE, AND FORLAP JOINTS IN SHEET METAL, FOR ALL PENETRATIONS IN THE CONCESSION AREAS NOT EXPOSED TO VIEW: BUTYL RUBBER BASED SEALANT CONFORMING TO FS TT-S-001657, TYPE 1. A. ADCO SEAL “NO. B-100”. B. PECORA CORPORATION “BC-158”. C. PTI SEALANTS “NO 707”. D. TREMCO “BUTYL SEALANT”. TYPE D JOINTS, VOIDS AND PENETRATIONS NOT OTHERWISE SPECIFIED FOR INTERIOR SURFACES EXPOSED TO VIEW AND REQUIRING PAINTING. FIXTURES, PARTITIONS, EQUIPMENT AND ACCESSORIES FASTENED TO WALLS AND FLOORS, FLANGES, AND ESCUTCHEONS OF ITEMS PENETRATING SURFACES IN CONCESSIONS, TOILET ROOMS, AND OTHER AREAS REQUIRING SANITARY CONDITIONS TO ELIMINATE ANY OPEN JOINTS BETWEEN CONTACT SURFACES: LATEX ACRYLIC BASED SEALANT CONFORMING TO ASTM C834. A. DOW CORNING CORPORATION “NO. 795”. B. GENERAL ELECTRIC COMPANY “SILPRUF”. C. SONNEBORN BUILDING PRODUCTS “OMNISEAL”. D. TREMCO “SPECREM 1”. TYPE E EXTERIOR AND INTERIOR JOINTS IN CONTACT WITH ORGANICALLY-COATED ALUMINUM: LOW MODULUS SILICONE SEALANT CONFORMING TO ASTM C920, TYPE S, GRADE NS, CLASS 25. A. DOW CORNING “NO. 792”. B. GENERAL ELECTRIC “SILPRUF”. C. SONNEBORN “OMNISEAL”. D. TREMCO “SPECREM 1”. TYPE F PERIMETER AND TACK SEAT JOINTS AROUND SOUND-RETARDANT PARTITIONS AND ELECTRICAL BOXES AND OTHER PENETRATIONS IN SUCH PARTITIONS: COMPOUND: PERMANENTLY RESILIENT TYPE MANUFACTURED SPECIFICALLY FOR ACOUSTICAL APPLICATIONS. A. USG – “ACOUSTICAL SEALANT”. B. TREMCO “ACOUSTICAL SEALANT”. BACKER ROD MATERIAL: CLOSED-CELL FOAM, NON-STAINING, RESILIENT MATERIAL SUCH AS NEOPRENE, BUTYL, OR POLYURETHANE, COMPATIBLE WITH SEALANT TO BE USED. SIZED AND SHAPED TO CONTROL DEPTH OF SEALANT AND TO PROVIDE 20 TO 50 PERCENT COMPRESSION UPON INSERTION. SEALANT INSTALLATION, INCLUDING SURFACE PREPARATION, BACK-UP MATERIALS AND SEALANT CURING, SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. CONTROL JOINTS IN ALL SURFACES AND MATERIALS SHALL HAVE PROPER BACKER ROD, IN ACCORDANCE WITH SEALANT MANUFACTURER'S RECOMMENDATION, INSTALLED IN JOINTS BEFORE SEALANT INSTALLATION. SEALANT WORK FOR THE GLASS AND GLAZING WORK SHALL BE PERFORMED BY THE GLASS AND GLAZING CONTRACTOR. PROVIDE 2 TUBES EA. COLOR AND TYPE UTLILZED FOR OWNER'S FUTURE USE. CAULKING AND JOINT SEALANTS ALL SURFACES TO BE PAINTED OR STAINED SHALL BE PROPERLY PREPARED BEFORE STARTING THE PAINTING WORK SHOP OR PRIME COATS SHALL BE PUT IN GOOD ORDER BEFORE PAINTING BEGINS. WOOD SHALL BE SMOOTH AND FREE FROM RAISED GRAIN OR OTHER SURFACE IMPERFECTIONS. METAL SURFACES SHALL BE WIRE BRUSHED TO REMOVE ALL RUST OR MILL SCALE. BEFORE PAINTING, REMOVE OR PROTECT HARDWARE, ACCESSORIES, PLATES, LIGHT FIXTURES AND SIMILAR ITEMS AND REPLACE UPON COMPLETION OF THE PAINTING OPERATION. APPLY PAINT OR STAIN TO CLEAN, DRY AND SMOOTH SURFACES ONLY. DO NOT APPLY EXTERIOR PAINT OR STAIN IN DAMP, RAINY WEATHER OR UNTIL ALL SURFACES HAVE THOROUGHLY DRIED. ALL WOOD AND METAL SURFACES SHALL BE SANDED SMOOTH BEFORE AND BETWEEN COATS. A SCHEDULE OF THE SURFACES TO BE PAINTED FOLLOWS: SCHEDULE OF SURFACES INTERIOR UNGALVANIZED FERROUS METAL 1 COAT NOXIDE ONE DAY PRIMER (IF UNPRIMED) 2 COATS CELLU-TONE SATIN GYPSUM BOARD SOFFITS 1 COAT PVA PRIMER 2 COATS LATEX (EGGSHELL) GYPSUM BOARD WALLS AND SOFFITS TO RECEIVE VWC TO BE PRIMED 1 COAT PRIMER-SEALER 2 COATS FINISH COLOR WOOD DOORS, WOOD CABINETWORK AND WOOD TRIM UNLESS OTHERWISE NOTED, STAIN TO MATCH EXISTING. SUBMIT FOR APPROVAL 1 COAT STAIN 3 COATS POLYURETHANE-LOW GLOSS 1 COAT LACQUER SEALER ON CONCEALED SURFACES OF WOOD TRIM. SCHEDULE OF COLORS PER MATERIALS NOTED. UNLESS NOTED OTHERWISE PAINT MISC.. METALS, ELECTRICAL AND TELEPHONE PANELS, FIRE EXTINGUISHER CABINETS (VERIFY), EXPOSED EQUIPMENT SUPPORT, CASEWORK AND PLUMBING SUPPORT BRACKETS, CLEAN-OUT COVERS, COVERS, TO MATCH THE SURFACE ON WHICH THEY OCCUR. PAINT EXPOSED PIPING IN FINISHED AREAS TO MATCH WALLS. PAINT ALL HOLLOW METAL FRAMES AS NOTED IN FINISH SCHEDULE, UNLESS NOTED OTHERWISE. PAINT METAL FRAMES AT VISION LITES IN DOORS TO MATCH DOOR FRAME FINISH, U.N.O. PAINTED GYPSUM BOARD CEILINGS TO BE CEILING BRIGHT WHITE, U.N.O. BOTTOMS OF SOFFITS IN PAINTED AREAS TO MATCH CEILING, U.N.O. PAINT EXPOSED CUT EDGES OF ACM TO MATCH ACM. PAINTING AND STAINING ACOUSTICAL CEILING SYSTEM IN ADDITION TO COMPLYING WITH ALL PERTINENT CODES AND REGULATIONS, CEILING INSTALLATION SHALL COMPLY WITH THE INDIANA STATE BOARD OF HEALTH AND SHALL MEET CLASS A NFPA REFERENCE STANDARD SUSPENSION SYSTEM ARMSTRONG PRELUDE XL REFERENCE STANDARD ACOUSTICAL CEILING PAD USG SEE DRAWINGS ERECT GRID SYSTEM SO THAT BORDERS WILL BE AS LARGE AS POSSIBLE, AVOIDING PERIMETER TILES LESS THAN 1/2 OF TILE SIZE, AND CENTER GRID IN ROOM, U.N.O. SPACE HANGARS A MAX. OF 4 FEET APART, THERE SHALL BE NO VISIBLE GAPS AT WALL ALL ACOUSTICAL CEILING PANELS: FLAME SPREAD OF 25 OR LESS PER ASTM E84. FURNISH TO OWNER TWO UNOPENED CARTONS OF ACOUSTICAL CEILING PADS OF EACH TYPE DELIVERED SEE CONTRACT DOCUMENTS FOR TYPES OF CEILING SYSTEMS. PROVIDE MATERIALS AS INDICATED IN CONTRACT DOCUMENTS AND INSTALL ACCORDING TO ALL MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. CARPET SHALL COMPLY WITH DOC-FFI-70-PILL TEST, ASTM E648 (NFPA 253)-CRITICAL FLUX TEST MIN. .45 WATTS PER SQUARE CORRIDORS AND EXITS AND .22 WATTS IN ALL OTHER AREAS. DIMENSIONAL STABILITY SHALL BE PLUS OR MINUS .02% WITH THE AACHEN METHOD. CARPET AND ADHESIVES SHALL COMPLY WITH STANDARDS FOR A CLASS II OR CLASS B FINISHES. PROVIDE ATTIC STOCK EQUAL TO 3% OF TOTAL SHEET CARPET AND CARPET TILE IN EACH STANDARD COLOR TO OWNER. PROVIDE METAL EDGE AND TRANSITION STRIPS AT ALL CHANGE OF MATERIALS. CARPET WALL COVERING SHALL COMPLY WITH ASTM E-84 FOR CLASS A, FS CCC-W-408A TYPE II. PROVIDE ONE ROLL OF WALLCOVERING OF EACH COLOR FROM ORIGINAL STOCK FOR OWNER'S USE. ALL ADHESIVES SHALL BE ONLY THOSE RECOMMENDED BY THE MANUFACTURER OF THE WALL COVERING. ALL WALL SEALER SHALL BE ONLY THAT RECOMMENDED BY THE MANUFACTURER OF THE WALL COVERING. SEAL ALL SURFACE TO RECEIVE WALL COVERING. APPLY EVENLY SO THAT NO DEPOSITS OR IRREGULARITIES TELEGRAPH THROUGH. INSTALL WALL COVERING IN CONSECUTIVE SEQUENCE. WRAP FABRIC 6' BEYOND INSIDE AND OUTSIDE CORNERS AND NO CUTTING AT CORNERS UNLESS FOR COLOR SEPARATION OR PATTERN MATCH. NO HORIZONTAL SEAMS SHALL BE PERMITTED. INSTALL WALLCOVERING BEFORE THE INSTALLATION OF PLUMBING FIXTURES, CASINGS BASES, CABINETS, AND SEALANTS. WALL COVERING AS NOTED IN CONTRACT DOCUMENTS. INSTALL PER MANUFACTURER'S RECOMENDATIONS. WALL AND CORNER GUARDS, HANDRAILS FIRE EXTINGUISHERS, CABINET AND ACCESSORIES FIRE EXTINGUISHERS: UL LISTED AND LABELED, EQUAL TO J.L. INDUSTRIES, MULTI-PURPOSE DRY CHEMICAL. TYPE CABINET-EQUAL TO J.L. INDUSTRIES SEMI-RECESSED (VERIFY WITH EXISTING), FULL GLASS PANEL BRUSH SATIN TRIM, BOX STEEL WITH BAKED ENAMEL FINISH. FIRE EXTINGUISHERS SERVING MRI AREAS MUST BE WITHIN 75' TO BE MRI SAFE. ELECTROMAGNETIC AND RADIO SHIELDING THE SUPPLIER/MANUFACTURER OF THE ELECTROMAGNETIC AND RADIO SHIELDING SHALL BE PRE-APPROVED BY THE MEDICAL EQUIPMENT SUPPLIER/MANUFACTURER THAT THEIR INSTALLATION CONFORMS WITH THE STANDARDS REQUIRED FOR PROPER OPERATION OF THE EQUIPMENT BEING SUPPLIED. COMPLETELY DESIGN, FURNISH AND INSTALL THE COMPLETE SHIELDED ENCLOSURE SYSTEM FOR THE ROOM, INCLUDING ALL SUBFRAMING, ANCHORS, JOINTING, SUBFLOORS, ACCESSORIES, DOORS, AND WINDOWS, AS WELL AS PENETRATIONS FOR EQUIPMENT. GROUNDING OF THE R-F ENCLOSURE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. OWNER SHALL BE RESPONSIBLE FOR ALL TESTING AND CONFIRMATION OF SHIELDING COMPLIANCE, U.N.O. ALL WALL AND CEILING SHIELDING MATERIALS ARE FRAMED OR LAMINATE PANELS MEETING THE MINUMUM REQUIREMENTS STATED IN THE PHYSICIST SHEILDING REPORT. FLOOR SHIELDING TO HAVE A 6 MIL VAPOR BARRIERS. WOOD FRAMING SHALL BE KILN DRIED AND FIRE RETARDANT. ALL SEAMS CONTINUOUSLY SOLDERED TOGETHER. ALL SEAMS COVERED WITH APPROPRIATE FOIL TAPE. FASTENERS TO BE NON- FERROUS, NON-OXIDIZING TYPE INSTALLED PER SHIELDING MANUFACTURER'S CRITERIA. DOOR UNITS SHALL CONSIST OF REQUIRED LEAVES, FRAMES, THRESHOLD, HARDWARE, AND CONTACT STRIPS. DOOR FRAME TO MEET REQUIREMENTS NOTED IN PHYSICIST REPORT WITH SPECIFIED WOOD VENEER OR GLASS. DOOR TO HAVE REMOVABLE SWEEP. WINDOWS TO BE COMPLETE WITH FRAME, RF SCREEN, GLASS, GLASS STOPS AND RF GASKETS. PROVIDE ALL REQUIRED FILTERS AND WAVE GUIDES FOR ELECTRICAL, HVAC, SPRINKLERS, AND CRYOGEN VENTS SHOWN ON THE DRAWINGS. SUPPLIER/MANUFACTURER TO PROVIDE WARRANTY THAT THE ENCLOSURE SHALL RETAIN ITS SHIELDING CHARACTERISTICS FOR 5 YEAR PERIOD AFTER TESTING. THE SHIELD ENCLOSURE SHALL PROVIDE THE REDUCTION OF RF WAVES FROM EXTERNAL TRANSMITTERS AS SPECIFIED BY THE EQUIPMENT MANUFACTURER AND PHYSICIST REPORT. TOILET ACCESSORIES TO BE EQUAL TO BOBRICK, U.N.O. SHOP DRAWINGS IF INCLUDED IN THE PROJECT SCOPE, SHOP DRAWINGS AND/OR PRODUCT LITERATURE ON THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL INCLUDING BUT NOT LIMITED TO: - DOORS AND DOOR HARDWARE - EXTERIOR FINISH MATERIALS - CASEWORK - WATERPROOFING - FIRE STOPPING - STEEL (FRAMING, MISC STEEL, STAIRS, REBAR, ETC) - ACOUSTICAL CEILINGS - ROOFING AND RELATED COMPONENTS - INTERIOR FINISHES - GLAZING AND STOREFRONT/CURTAIN WALL - FIRE EXTINGUISHER AND CABINETS - LOCKERS - ELECTROMAGNETIC AND RADIO SHIELDING - PLUMBING EQUIPMENT / FINISHES - LIGHT FIXTURES - TOILET ACCESSORIES AND PARTITIONS - HVAC EQUIPMENT, GRILLES, REGISTERS & DIFFUSERS SUBSTITUTIONS GENERAL CONTRACTOR TO SUBIT DATA TO ARCHITECT FOR REVIEW AND CONFIRMAITON OF EQUAL COMPLIANCE PRIOR TO ALLOWING SUBSTITUIONS. ALL SUBSTITUTION FOR SPECIFIED PRODUCTS SHALL BE BY WRITTEN APPROVAL OF THE ARCHITECT CAST-IN-PLACE CONCRETE (CONT'D) # Revision Description Date Issued 06/08/21 > >> > M H KCRCR M H H HWAP 442 2 D DD D D D D OC OC2 2 VV V V VVV4 44 4 22 > >> >>> >> > > > >> > > >> >> > >> > > >> > >> EXISTING BUILDING AREA FIRE EXTINGUISHER LOCATIONS (SEE SHEET A100) EXISTING BUILDING OF RENOVATION EXT E EXISTING BUILDING EXIT EXT A BUILDING ADDITION EXIT FEC 1 HOUR SMOKE BARRIER 2 HOUR SMOKE BARRIER/FIRE BARRIER 2 HOUR FIRE BARRIER PATH OF EGRESS SMOKE RESISTANT CORRIDOR 1 HOUR CORRIDOR 2 HOUR CORRIDOR SMOKE RESISTANT SHAFT 1 HOUR SHAFT 2 HOUR SHAFT SMOKE RESISTANT HAZAROUS ROOM 2 HOUR EXIT ENCLOSURE B.6 B.9 D.3 4.14122.2 2.4 2.6 2.8 3 D D.5 E E.5 F G F.9 C C.1 D.4 G.1 B.95 B.7 .9 WAITING 001RECEPTION 003 MD NURSE 004 W&M 005 WORK ALCOVE 012 EXAM 4 011 PATIENT RR 006 STORAGE 010 EXAM 3 009 EXAM 2 008 EXAM 1 007 OFFICE 002 L1 L1 L1 L2 L2 L3 EXT E EXT E B.6 B.9 D.3 44.1 2 2.2 2.4 2.6 1 F G F.9 G.1 .9 D.5 E E.5 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 LIFE SAFETY PLAN 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290LIFE SAFETY PLAN LEGEND LIFE SAFETY PLAN NOTES L1 PATH OF EGRESS. L2 EXISTING EXIT LOCATION L3 NEW FIRE EXTINGUISHER LOCATION APPLICABLE CODES:2014 INDIANA BUILDING CODE (2012 INTERNATIONAL BUILDING CODE) 2010 INDIANA ENERGY CONSERVATION CODE (675-ISE 19-4) 2014 INDIANA FIRE CODE (2012 INTERNATIONAL FIRE CODE) 2012 INDIANA PLUMBING CODE (2006 INTERNATIONAL PLUMBING CODE WITH 2012 AMENDMENTS) 2009 INDIANA ELECTRICAL CODE (2008 NFPA 70) 2014 INDIANA MECHANICAL CODE (2012 INTERNATIONAL MECHANICAL CODE) 2014 INDIANA FUEL GAS CODE (2012 INTERNATIONAL FUEL GAS CODE) PROJECT LOCATION: OCCUPANCY: SQUARE FOOTAGE: HEIGHT: CONSTRUCTION TYPE: WIDTH OF EXITS: FIRE SUPPRESSION SYSTEM: FIRE RESISTIVE CORRIDORS: SMOKE RESISTIVE CORRIDORS: HAZARDOUS ROOMS: EXIT ACCESS TRAVEL DISTANCE: OCCUPANT LOAD: CODE REVIEW SUMMARY PLUMBING COUNT: ALARMS / FIRE DETECTION: ACCESSIBILITY:PER BUILDING OCCUPANCY / ANSI REQUIREMENTS 10300 N. Illinois St, Suite 1200 Indianapolis, IN 46290 TYPE B OCCUPANCY 1631 SF EXISTING 1631 SF REMODELED BUILDING IS 2 STORIES TYPE II-B NOT REQUIRED PROJECT AREA: FULL SPRINKLER SUPPRESSION SYSTEM EXISTING BUILDING: FULLSPRINKLER SUPPRESSION SYSTEM NOT REQUIRED CONSTRUCTED AS SMOKE RESISTANT ASSEMBLIES: CLEAN ROOM, SOILED UTILITY ROOM, EQUIPMENT STORAGE EXIT ACCESS TRAVEL DISTANCE: NOT TO EXCEED 300 FEET DEAD END EXIT ACCESS: NOT TO EXCEED 50 (OR 20 IN I OCC.) FEET 100 SF PER OCCUPANT REQUIRED. 1631 SQUARE FEET 17 OCCUPANTS 1 OCCUPANTS 1 REQUIRED PER 25 OCCUPANTS; 1 REQUIRED 1 REQUIRED PER 40 OCCUPANTS; 1 REQUIRED AUTOMATIC FIRE DETECTION IS/NOT REQUIRED ALARM SYSTEM PER SECTION 907.2.6.2 EXIT DOOR WIDTH PROVIDED AT THE RATE OF 0.15 INCHES PER OCCUPANT. (SEC. 1005.2.3) NORTH 1/8" = 1'-0"A004 LEVEL 1 - LIFE SAFETY PLAN - GI CLINIC1 NORTH KEY PLAN - NOT TO SCALE AREA OF WORK # Revision Description Date Issued 06/08/21 1 2 E.5 F G F.9 G.1 .9 D1 D1 D1 D1 D2 D2 D2D2 D2 D2 D2 D2 D2 D3 TYP. D3 TYP. D3D3 D3 TYP. D3 D3D3 D3D3 D3 D3D3D3 D3D3 D3D3 D4D4 D5 D5 D5 D5 D6ETRLVT1 ETRLVT1 ETRLVT1 D12 D1 D2 D5D8 D8 D8 D8 D8 D9D9 D10 D11 D11 D7D7 D16 1 2 E.5 F G F.9 G.1 .9 R1R1 R1R1 R1 R1 R2 R1 R1 R1 R1 R2 R2R2 R3 R3 R3 R4R4 R4R4 R4R4 R4R4R4R4 R4R4 R4 R3 R3 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 DEMOLITION PLAN 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290GENERAL DEMOLITION NOTES A. SEE GENERAL NOTES ON CUTTING AND PATCHING OUTLINED ON SHEET A001 FOR ADDITIONAL INFORMATION. B. PERFORM ALL WORK UNDER ESTABLISHED PROJECT GUIDELINES. C. FIELD VERIFY EXISTING CONDITIONS AND COORDINATE DEMOLITION OR REMOVAL WORK WITH CORRESPONDING NEW CONSTRUCTION WORK AND APPROPRIATE TRADES PRIOR TO STARTING DEMOLITION WORK. IF DISCREPANCIES ARE FOUND BETWEEN CONTRACT DOCUMENTS AND ACTUAL FIELD CONDITIONS, NOTIFY ARCHITECT IMMEDIATELY. D. DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED. UNLESS OTHERWISE NOTED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE OFF-SITE DISPOSAL OF ALL DEMOLITION ITEMS. E. REMOVE ALL CONSTRUCTION DEBRIS FROM SITE DAILY. DO NOT ALLOW REFUSE TO BLOCK CORRIDORS, STAIRS, OR ANY OTHER TRAFFIC AREAS. F. PROVIDE TEMPORARY FIRE AND LIFE SAFETY PROTECTION THROUGHOUT DURATION OF PROJECT. G. PATCH AND REPAIR ALL ADJACENT SURFACES DISTURBED/DAMAGED BY CONSTRUCTION. CLEAN ALL FLOOR SURFACES OF ADHESIVE AND OR GROUT RESIDUE PRIOR TO INSTALLATION OF NEW FLOORING MATERIAL. H. PROTECT ADJACENT EXISTING TO REMAIN CONSTRUCTION THROUGHOUT DURATION OF PROJECT. PROVIDE SHORING, BRACING OR SUPPORT AS REQUIRED TO PREVENT MOVEMENT OR SETTLEMENT OF EXISTING CONSTRUCTION. I. PROVIDE CONSTRUCTION BARRIER PARTITIONS BETWEEN AREAS OF WORK AND OCCUPIED SPACES (IF APPLICABLE). PARTITIONS TO REMAIN INTACT THROUGHOUT CONSTRUCTION, INCLUDING COMPLETED WORK AND WORK UNDER CONSTRUCTION. J. NEGATIVE PRESSURE MONITORED CONTINUOUSLY, SHALL BE PROVIDED AT ALL DUST BARRIERS WHEN REQUIRED BY BUILDING/PROJECT STANDARDS AND OR MANDATED INFECTION CONTROL REQUIREMENTS. K. WHERE BLOCKING AND/OR ELECTRICAL WORK IS REQUIRED IN EXISTING WALL CONSTRUCTION, CONTRACTOR TO CAREFULLY CUT-OUT GYPSUM BOARD AT APPROPRIATE LOCATION. PATCH AND FINISH AREA PER CUTTING AND PATCHING/FINISHING NOTES ON SHEET A001. L. REMOVE ALL EXISTING CONSTRUCTION ITEMS AND FINISHES MADE OBSOLETE BY OR IN CONFLICT WITH NEW CONSTRUCTION. VERIFY WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE. REMOVE WIRING BACK TO SOURCE AT ALL OUTLETS, ETC. MADE OBSOLETE BY WALL REMOVAL OR ANY OTHER NEW CONSTRUCTION. M. REMOVE ALL ITEMS IN THEIR ENTIRETY UNLESS OTHERWISE NOTED. DESCRIPTION OF PRIMARY ITEMS TO BE REMOVED IS GENERAL IN NATURE, AND REMOVAL OF SECONDARY COMPONENTS SUCH AS BLOCKING, SUPPORTS, ANCHORS, TRIM, ADHESIVE, PIPING, WIRING, ETC., RELATED TO PRIMARY ITEMS SHALL BE INCLUDED. N. RELOCATED ITEMS SHALL BE CLEANED AND PLACED IN STORAGE PER OWNER'S DIRECTIONS UNTIL ITEMS ARE READY TO BE REINSTALLED. IF ITEM IS DAMAGED DURING DEMOLITION OR RELOCATION, IT SHALL BE REPAIRED WITH NEW ITEM AS APPROVIDED BY OWNER AT NO EXPENSE TO OWNER. O. AT OWNER'S REQUEST, SALVAGED ITEMS SHALL BE TURNED OVER TO THE OWNER OR STORED IN AN AREA DESIGNATED BY THE OWNER. P. IF EXISTING ITEMS TO BE REMOVED OR DISTURBED ARE SUSPECTED OR DISCOVERED TO CONTAIN ASBESTOS OR OTHER HAZARDOUS MATERIALS, STOP DEMOLITION AND NOTIFY OWNER IMMEDIATELY. Q. SEE M.E.P. DOCUMENTS FOR EXTENT OF DEMOLITION/REMOVAL OF PIPING/DUCTWORK/ELECTRICAL THAT WILL OCCUR IN PREPARATION FOR NEW CONSTRUCTION. DEMO PLAN NOTES D9 REMOVE EXISTING TOILET, GRAB BARS, WALL MOUNTED SINK, MIRROR, SOAP AND PAPER TOWEL DISPENSER. SALVAGE FOR REINSTALLATION. D10 REMOVE EXISTING WINDOW AND TRANSACTION COUNTER COMPLETE. D11 REMOVE PORTION OF WALL AS REQUIRED FOR INSTALLATION OF NEW TRANSACTION WINDOW. SEE NEW PLAN AND ELEVATIONS. D12 REMOVE PORTION OF WALL UP TO 7'-8". PREP TO BECOME NEW BULKHEAD. SEE NEW REFLECTED CEILING PLAN. D16 REMOVE PORTION OF WALL AS INDICATED TO CREATE NEW OPENING. DEMO PLAN NOTES D1 REMOVE PORTION OF WALL COMPLETE AS INDICATED D2 REMOVE CASEWORK AND COUNTERTOP COMPLETE. D3 REMOVE EXISTING FLOOR FINISH, WALL BASE, ADHESIVES, ETC, COMPLETE. PREP FLOOR TO RECIEVE NEW FINISH AS SCHEDULED D4 REMOVE EXISTING WALL PANELING COMPLETE. PREP WALL TO RECEIVE NEW FINISH AS SCHEDULED. D5 REMOVE EXISTING DOOR, FRAME AND HARDWARE COMPLETE. SALVAGE FOR REINSTALLATION WHEREVER POSSIBLE. ANY DOORS, FRAMES OR HARDWARE NOT REINSTALLED SHALL BE DISPOSED OF BY CONTRACTOR. D6 REMOVE PORTION OF WALL AS SHOWN FOR INSTALLATION OF NEW DOOR AND FRAME. SEE NEW FLOOR PLAN AND DOOR SCHEDULE. D7 REMOVE WALLCOVERING. PREP WALL TO RECEIVE NEW FINISH AS SCHEDULED D8 REMOVE PLUMBING FIXTURE. COORDINATE WITH MEP DRAWINGS. NORTH 3/16" = 1'-0"A050 LEVEL 1 - DEMOLITION PLAN - GI CLINIC1 NORTH 3/16" = 1'-0"A050 LEVEL 1 - DEMO REFLECTED CEILING PLAN - GI CLINIC2 NORTH KEY PLAN - NOT TO SCALE AREA OF WORK # Revision Description Date Issued DEMO RCP NOTES R1 REMOVE EXISTING CEILING GRID AND TILE COMPLETE. COORDINATE WITH MEP DRAWINGS. SALVAGE CEILING TILES FOR REINSTALLATION. R2 REMOVE PORTION OF CEILING TO ALLOW FOR NEW WALL CONSTRUCTION. SEE NEW PLAN. R3 REMOVE EXISTING DRYWALL BULKHEAD COMPLETE. R4 EXISTING TO REMAIN CEILING 06/08/21 A600 2 A600 12 A600 5 3 4 A600 8 9 A600 10 A600 1 WAITING 001 LVT1 B1 P1 RECEPTION 003 LVT1 B1 P1 MD NURSE 004 LVT1 B1 P1 W&M 005 LVT1 B1 P1 PATIENT RR 006 LVT1 B1 P1 EXAM 1 007 LVT1 B1 P1 EXAM 2 008 LVT1 B1 P1 EXAM 3 009 LVT1 B1 P1 STORAGE 010 LVT1 B1 P1 EXAM 4 011 LVT1 B1 P1 WORK ALCOVE 012 LVT1 B1 P1 6 7 A60011 EQ EQ etr card reader A600 1 A600 1 A6002 A600 2 001a001c002a 003a004a 009a011a010a 006a 001b002b OFFICE 002 ETR ETR ETR ETRLVT1ETRLVT1 ETRLVT1 1 1 1 2 2 3 3 4 4 4 5 6 6 6 6 6 6 6 6 6 66 6 6 77 88 88 88 8888 8 5' - 0"2' - 5" 2' - 0" 2 2 A A A A CG1 CG1 CG1 7' - 3"9 10 1212 13 1212 4 4 8 11 14 15 Room Name Room Number Floor Finish Base Finish Typ. Wall Finish Finish Remarks FINISH TAG: GRAIN / FLOORING DIRECTION: CORNER GUARD: FLOORING TRANSITION: CORNER GUARD END CAP: FLOOR TYPE 2 FLOOR TYPE 1 TRANSITION DETAIL F-1 HOLLOW METAL - WELDED4"7' - 0" 7' - 4"2" 3' - 0" 2" VARIES A INSULATED HOLLOW METAL (IHM) VARIES VARIES3-5/8" STUD WALL - TO CEILINGB BASE AS SCHED. PLAN VIEW SUSPENDED CEILING - REFER TO REFLECTED CEILING PLAN. 3-5/8" STEEL STUDS @ 16" O.C. STEEL STUD RUNNER TRACK. STUDS SCREWED ON EA. SIDE AT BOTTOM. ONE LAYER 5/8" GYP. BD. EA. SIDE. FLOOR SLAB 3" ROCKWOOL SAFE-N- SOUND BATT INSULATION TO DECK WITH INSULATION SUPPORTS AS REQUIRED 5/8" 3 5/8" 5/8"3/8"DECK 4 7/8" ELIMINATOR TRACK TO RECEIVE WALL STUDS. SECURE TRACT TO CEILING WITH PAN-HEAD SCREWS SUPPLIED BY TRACK MANUFACTURER TYPICAL 3-5/8" STUD WALL - NON-RATED A 3-5/8" STUD WALL TO 6" ABOVE CEILING W/ ROCKWOOL SAFE-N-SOUND BATT INSULATION BASE AS SCHED. PLAN VIEW SUSPENDED CEILING - REFER TO REFLECTED CEILING PLAN. 3-5/8" STEEL STUDS @ 16" O.C. STEEL STUD RUNNER TRACK. STUDS SCREWED ON EA. SIDE AT BOTTOM. ONE LAYER 5/8" GYP. BD. EA. SIDE. FLOOR SLAB 3" ROCKWOOL SAFE-N-SOUND BATT INSULATION TO DECK WITH INSULATION SUPPORTS AS REQUIRED 5/8" 3 5/8" 5/8"3/8" DECK 6"4 7/8" www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 FLOOR PLAN 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290GENERAL FLOOR PLAN NOTES A. CONTRACTOR TO FOLLOW ALL BUILDING/PROJECT STANDARDS. PROVIDE INTERIM LIFE SAFETY MEASURES AND FOLLOW ALL STATE AND LOCAL BUILDING CODES. IF CONTRARY INSTRUCTIONS ARE CONTAINED HEREIN, REQUEST CLARIFICATION FROM OWNER/ARCHITECT. B. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS, JOB CONDITIONS, ETC. C. SEE FLOOR PLAN FOR ADDITIONAL NOTES. D. ALL DIMENSIONS ARE FROM FACE OF STUD FRAMING TO FACE OF STUD FRAMING UNLESS OTHERWISE NOTED. E. SEE WALL TYPES, DOORS AND HARDWARE SCHEDULES FOR ADDITIONAL INFORMATION. F. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHOULD DO SO UNDER THE CENTERLINE OF THE DOOR, UNLESS OTHERWISE NOTED. G. SEE TYPICAL DETAILS FOR LOCATION OF HINGE SIDE OF DOOR JAMBS FROM ADJACENT WALLS IN METAL STUD WALLS UNLESS OTHERWISE NOTED. H. PROVIDE BLOCKING IN NEW AND EXISTING WALLS FOR ALL WALL SUPPORTED ITEMS. SEE PLANS FOR CASEWORK LOCATIONS. I. ALL MATERIALS TO BE INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND STANDARD SPECIFICATIONS. J. REFER TO ROOM FINISH SCHEDULE FOR ALL REQUIRED FINISH INFORMATION. K. WHERE NEW WALL CONSTRUCTION IS REQUIRED ADJACENT TO OR ABUTTING EXISTING CONSTRUCTION, ALIGN FACE OF NEW CONSTRUCTION WITH FACE OF EXISTING CONSTRUCTION. SKIM ENTIRE WALL SURFACE AS REQUIRED TO PROVIDE SMOOTH, FLUSH TRANSITIONS. L. PROVIDE CONTROL JOINTS IN ALL RUNS OF GYPSUM BOARD. WALLS OVER 30 FEET IN LENGTH. COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION FOR COMPLIANCE WITH DESIGN INTENT. M. PREP ALL WALL SURFACES TO RECEIVE NEW PAINT OR WALL COVERING FINISH. PATCH ALL EXISTING HOLES IN AREAS TO RECEIVE NEW FINISHES. SAND WALLS SMOOTH PRIOR TO PAINTING. PROVIDE BLANK COVER PLATES WHERE NEEDED. REMOVE EMERGENCY LIGHTS, SIGNAGE, THERMOSTATS, FIRE STROBES, ETC. PRIOR TO PAINTING AND REINSTALL WHEN COMPLETE. N. ALL PENETRATIONS IN AND THROUGH FIRE AND SMOKE RATED WALLS SHALL BE SLEEVED AND FIRE STOPPED AS NECESSARY TO MAINTAIN RATINGS. O. SEE MEP DRAWINGS FOR RELATED LEGENDS AND SCOPE OF WORK. FLOOR PLAN NOTES 1 ALIGN NEW WALL CONSTRUCTION WITH EXISTING TO REMAIN. 2 INFILL WALL TO MATCH EXISTING CONSTRUCTION. PROVIDE SMOOTH TRANSITION. 3 NEW TRANSACTION WINDOW WITH SOLID SURFACE SILL. SEE ELEVATIONS AND DETAILS. 4 PATCH/REPAIR WALL AT LOCATION OF DEMOLITION IN PREP FOR NEW FINISH, AS SCHEDULED 5 EXISTING TO REMAIN CASEWORK. 6 PROVIDE NEW CASEWORK PER ELEVATION. 7 INSTALL RELOCATED PLUMBING FIXTURES AND ACCESSORIES. SEE ACCESSABILITY GUIDELINES ON A002 FOR MOUNTING HEIGHTS AND LOCATIONS. 8 PROVIDE ACCENT PAINT THIS WALL ONLY. COLOR TBD. 9 INTALL NEW TOILET FIXTURE. SEE ACCESSABILITY GUIDELINES AND MEP FOR DIMENSIONS. 10 NEW WALL HUNG FIRE EXTINGUISHER 11 PROVIDE NEW VERTICAL SIDE AND REAR GRAB BARS. SEE ACCESSIBILITY GUIDELINES A002 FOR INSTALLATION HEIGHTS AND LOCATIONS. 12 SKIM COAT EXISTING WALLS TO PROVIDE SMOOTH FINISH AND PREP FOR PAINT, TYP. 13 EXISTING PARTIAL HEIGHT WALL. PROVIDE NEW WALL CONSTRUCTION FROM TOP OF EXISTING PARTIAL HEIGHT WALL TO CEILING, WALL TYPE B. 14 INSTALL ROLL TOILET PAPER HOLDER AND SANITARY NAPKIN DISPENSER. SEE A002 ACCESSIBILITY GUIDELINES FOR MOUNTING HEIGHTS AND LOCATIONS. 15 INTALL PAPER TOWEL AND SOAP DISPENSER AT SINK LOCATION. SEE A002 FOR MOUNTING HEIGHTS AND LOCAITONS. NORTH 1/4" = 1'-0"A100 LEVEL 1 - NEW FLOOR PLAN - GI CLINIC1 FINISH MATERIAL LIST - GI REV. # MARK MANUFACTURER STYLE MODEL NUMBER COLOR SIZE CORNER GUARDS CG1 INPRO 2" SURFACE APPLIED CORNER GUARD TBF FULL HEIGHT LUXURY VINYL TILE LVT1 TBD PAINT P1 / EP1 TBD P2 TBD P3 TBD PLASTIC LAMINATE PL1 TBD PL2 TBD RESILIENT BASE B1 TBD SOLID SURFACE SS1 TBD PLAN LEGEND DOOR SCHEDULE MARK DOOR FRAME HEAD JAMB SILL FIRE RATING HARDWARE COMMENTSWIDTH HEIGHT TYPE MATERIAL FINISH TYPE MATERIAL FINISH 001a 6' - 0" 8' - 0" ETR ETR ETR ETR ETR ETR ETR ETR ETR N/A ETR CARD READER EXISTING TO REMAIN 001c 3' - 0" 8' - 0" ETR ETR ETR ETR ETR ETR ETR ETR ETR N/A 2 002b 3' - 0" 8' - 0" ETR ETR ETR ETR ETR ETR ETR ETR ETR N/A 2 003a 3' - 0" 8' - 0" A TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR N/A 2 REUSE SALVAGED DOOR WHEN POSSIBLE WITH HANDING 004a 3' - 0" 8' - 0" A TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR N/A 2 REUSE SALVAGED DOOR WHEN POSSIBLE WITH HANDING 006a 3' - 0" 8' - 0" A TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR N/A 1 REUSE SALVAGED DOOR WHEN POSSIBLE WITH HANDING 009a 3' - 0" 8' - 0" A TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR TO MATCH ETR N/A 3 REUSE SALVAGED DOOR WHEN POSSIBLE WITH HANDING 011a 3' - 0" 8' - 0" ETR ETR ETR ETR ETR ETR ETR ETR ETR N/A 3 NORTH KEY PLAN - NOT TO SCALE AREA OF WORK # Revision Description Date Issued HARDWARE SET #1 · (3) PAIR 4-1/2" HINGES · PRIVACY LOCKSET · DOOR SILENCERS · (1) WALL BUMPER HARDWARE SET #2 · (3) PAIR 4 1/2" HINGES · OFFICE LOCKSET · DOOR SILENCERS · (1) WALL BUMPER HARDWARE SET #3 · (3) PAIR 4 1/2" HINGES · PASSAGE LOCKSET · DOOR SILENCERS · (1) WALL BUMPER 1/4" = 1'-0"A100 DOOR FRAME ELEVATIONS2 1/4" = 1'-0"A100 DOOR ELEVATIONS3 1 1/2" = 1'-0"A100 WALL TYPES4 06/08/21 RECESSED LIGHT NEW 2' X 4' RECESSED FIXTURE NEW CEILING GRID EXISTING CEILING GRID WALL MOUNTED EXIT SIGN CEILING MOUNTED EXIT SIGN HVAC SUPPLY DIFFUSER HVAC RETURN GRILLE SMOKE DETECTORSD EXISTING 2' X 4' RECESSED FIXTURECEILING TYPE MATERIAL/DETAIL VARIATION CEILING HEIGHT CLG1 1' - 0" 1 2 E.5 F G F.9 G.1 .9 ETRX2 ETRX ETRX2 ETRX M.E. CLG1 M.E.CLG1 M.E.CLG1 ETRX2 M.E.CLG1 ETRX2 ETRX2 ETRX2 ETRCLG1 RECEPTION 003 WAITING 001 MD NURSE 004 W&M 005 PATIENT RR 006 EXAM 4 011 WORK ALCOVE 012 EXAM 3 009 EXAM 2 008 EXAM 1 007 STORAGE 010 C1 X 8' - 0" C2 C3 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 REFLECTED CEILING PLAN 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290GENERAL REFLECTED CEILING NOTES A. DIMENSIONS ON REFLECTED CEILING PLAN ARE TAKEN FINISHED FACE TO FINISHED FACE. B. SEE ELECTRICAL FOR SWITCHING OPERATION AND LOCATION. C. COORDINATE ALL DUCTWORK AND LIGHTING WITH STRUCTURE, BULKHEAD AND CEILING TO DECK CLEARANCES PRIOR TO STARTING WORK. D. LIGHTS AND DIFFUSERS SHOWN FOR LOCATION. SEE ELECTRICAL AND HVAC PLANS FOR FIXTURE COUNTS AND TYPES. E. UNLESS OTHERWISE NOTED/SHOWN - CENTER NEW GRID EACH DIRECTION IN ROOM. MAINTAIN MINIMUM EDGE TILE AT 6". F. UNLESS OTHERWISE NOTED/SHOWN - PLASTER / GYP. BOARD BULKHEAD SIDES AND UNDERNEATH TO BE PAINTED, PAINT TO BE GENERAL CEILING WHITE. MEP DESIGN BUILD NOTES A. GENERAL CONTRACTOR SHALL COORDINATE ALL TRADES, INCLUDING DESIGN BUILD CONTRACTORS, AND ENSURE MEP SUBCONTRACTORS MEET WITH OWNER, DESIGNER, AND OTHERS TO ENGINEER SYSTEMS TO MEET OWNER'S NEEDS. B. GENERAL CONTRACTOR SHALL PROVIDE MEP DESIGN DOCUMENTS AND DRAWINGS TO OWNER AND DESIGNER FOR REVIEW, COMMENT AND APPROVAL. C. GENERAL CONTRACTOR SHALL ENSURE MEP DESIGN BUILD DOCUMENTS ARE SUBMITTED TO THE STATE AND LOCAL CODE OFFICIAL AS REQUIRED BY STATE STATUE/LAW. D. HVAC SYSTEMS TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT. E. ELECTRICAL POWER & DATA SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT. F. LIGHTING SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT. G. PLUMBING SYSTEMS ARE TO BE VENDOR ENGINEERED UNDER SEPERATE CONTRACT. H. G.C. IS RESPONSIBLE TO PROVIDE ALL COORDINATION OF DESIGN AND CONSTRUCTION DISCIPLINES. I. G.C. IS RESPONSIBLE TO PROVIDE ALL DESIGN, MATERIAL AND LABOR UNDER SEPERATE VENDOR CONTRACT AS REQUIRED FOR A COMPLETE INSTALLATION IN COMPLIANCE WITH ALL STATE, LOCAL AND HEALTH DEPARTMENT BUILDING CODES. J. ARCHITECTURAL DOCUMENTS PROVIDE SUGGESTED LIGHTING LOCATIONS AND FIXTURE TYPES. ALL CIRCUITING TO BE VENDOR ENGINEERED BY CONTRACTOR. K. CONTRACTOR SHALL DESIGN AND PROVIDE EMERGENCY LIGHTING AS REQUIRED BY STATE AND LOCAL CODE. L. CONTRACTOR SHALL DESIGN AND INSTALL SALVAGED BUILDING STANDARD FIXTURES AT LOCATIONS INDICATED TO MATCH BUILDING STANDARD FIXTURES AND ONLY PROVIDE NEW FIXTURES WHERE REQUIRED. M. CONTRACTOR SHALL PROVIDE INDEPENDANT SWITCHING FOR EACH AREA AND AT A LOGICAL AREA ENTRY. IN CORRIDORS AND LARGE PUBLIC AREAS, PROVIDE MULTIPLE SWITCH LOCATIONS. N. PROVIDE DIMMABLE SWITCHES AT ALL FIXTURES THAT ARE DIMMABLE. O. CONTRACTOR SHALL DESIGN AND PROVIDE EXIT LIGHTING TO MATCH BUILDING STANDARD AND TO MEET STATE AND LOCAL CODES. REFLECTED CEILING PLAN LEGEND REFLECTED CEILING PLAN NOTES C1 PROVIDE NEW LAYER OF GYP BOARD AT AREA OF DEMOLITION TO CREATE NEW BULKHEAD. C2 INFILL BULKHEAD TO WALL. HEIGHT, SIZE AND FINISH TO MATCH EXISTING. C3 PATCH AND REPAIR CEILING AS REQUIRED TO PROVIDE NEW WALL CONSTRUCTION ABOVE EXISTING TO REMAIN 6'-0"AFF PARTIAL HEIGHT WALL. CEILING TYPE SCHEDULE TAG MANUFACTURER STYLE # COLOR SIZE COMMENTS CLG1 ARMSTRONG .75 NRC MINERAL FIBERBOARD, 35 CAC, ULTIMA, STRAIGHT EDGE 1910HRC WHITE 2'X2' 15/16" GRID X EXISTING TO REMAIN GRID AND TILE X2 EXISTING TO REMAIN GRID WITH NEW TILE TO MATCH CLG1 NORTH 1/8" = 1'-0"A120 LEVEL 1 - NEW REFLECTED CEILING PLAN - GI CLINIC1 NORTH KEY PLAN - NOT TO SCALE AREA OF WORK # Revision Description Date Issued 06/08/21 2' - 6"2' - 6" PLAM WORKSURFACE FULL HEIGHT SUPPORT PANEL PENCIL DRAWER BELOW WINDOW BEYOND WINDOW BEYOND SUPPORT CLEAT ON SIDE WALL PAINTED TO MATCH WALL 6C A702 ADA SINK BASE WITH FINISHED END PLAM COUNTERTOP WITH SINK BASE AS SCHEDULED 2' - 6"1' - 8" 2' - 10" 2' - 6"7' - 0"2' - 6" FILLER PLAM WALL CABINET WITH FINISHED END 6E A702 6E A702 2' - 6" 2' - 0" 2' - 6" 2' - 6" 2' - 6" EQ EQ PLAM WORKSURFACE SUPPORT BRACKET BASE AS SCHEDULED PLAM WALL CABINETS FILLER FINISHED END 4E A702 6C A702 2' - 6"2' - 6" 2' - 0" 3' - 6"2' - 9"2' - 9" 2' - 9" 3' - 0" PLAM WORKSURFACE SUPPORT BRACKET BASE AS SCHEDULED PLAM WALL CABINETS FILLER 4E A702 6C A702 EQEQ EQ EQ 2' - 6"3' - 8" 2' - 3" 3' - 8" WINDOW BEYOND PLAM WORKSURFACE FULL HEIGHT SUPPORT PANEL SUPPORT CLEAT ON SIDE WALL PAINTED TO MATCH WALL SUPPORT BRACKET WINDOW BEYOND 6C A7022' - 6"1' - 10" 2' - 6" 2' - 6"2' - 6" MAX 3' - 8" PLAM WORKSURFACE SUPPORT BRACKET BASE AS SCHEDULED CASEWORK LOCK, TYP PLAM WALL CABINETS FILLER FINISHED END 4E A702 6C A702 2' - 6" 2' - 0" 2' - 6" 7' - 0"2' - 6"2' - 6" 3' - 8" 5' - 0" PLAM WORKSURFACE SUPPORT BRACKET BASE AS SCHEDULED CASEWORK LOCK, TYP PLAM WALL CABINETS FILLER FINISHED END 4E A702 6C A702 2' - 6"WINDOW BEYOND WINDOW BEYOND 6' - 6" PLAM WORKSURFACE FULL HEIGHT SUPPORT PANEL SUPPORT CLEAT ON SIDE WALL PAINTED TO MATCH WALL SUPPORT BRACKET 6C A702 2' - 6"2' - 10"EQ MAX 3' - 8" MAX 3' - 8" MAX 3' - 8" EQ 4' - 0" 4' - 0" SOLID SURFACE SILL SLIDING TRANSACTION WINDOW FINISHED FLOOR BASE AS SCHEDULED PLAM WORKSURFACE SUPPORT BRACKET 6C A702 4C A702 3' - 6"2' - 6" PLAM WORKSURFACE SUPPORT CLEAT ON SIDE WALL PAINTED TO MATCH WALL SUPPORT BRACKET OWNER PROVIDED SCALE, PROVIDE POWER SEE MEP 6C A702 4' - 0" 7' - 0"4' - 2"2' - 10" 4' - 0" SOLID SURFACE SILL SLIDING TRANSACTION WINDOW FINISHED FLOOR BASE AS SCHEDULED 4C A702 2' - 6" 2' - 0" 2' - 6"EQ EQ 2' - 0" 1" PLAM WORKSURFACE SUPPORT BRACKET BASE AS SCHEDULED 1' - 6" 2' - 9" 2' - 9" 1" PRINTER CABINET WITH ROLL OUT DRAWER, FINISHED ENDS AND INSIDE CASEWORK LOCK, TYP PLAM WALL CABINETS FILLER 6C A702 6B A702 4E A702 GENERAL CASEWORK... A. CONTRACTOR SHALL BE RESPONSIBLE FOR THE FIELD VERIFICATION OF ALL DIMENSIONS, ROUGH OPENINGS AND JOB CONDITIONS PRIOR TO THE BEGINNING OF FABRICATION OF ANY WORK SHOWN OR NOTED ON THIS DRAWING. CONTRACTOR TO CONTACT ARCHITECT WITH ANY DISCREPANCIES BETWEEN WHAT IS SHOWN OR NOTED ON THIS DRAWING AND ACTUAL FIELD VERIFIED CONDITIONS. CONTRACTOR TO SUBMIT SHOP DRAWINGS TO ARCHITECT FOR FINAL REVIEW. B. ALL DRAWER PULLS TO BE CONTRACTOR SUPPLIED AND INSTALLED. SEE SPECIFICATIONS. C. PROVIDE FILLER PANELS AT ALL CASEWORK LOCATIONS BUTTING INTO WALL CONSTRUCTION. MINIMUM FILLER SIZE TO BE 1" WIDE. MAXIMUM FILLER SIZE TO BE 3" WIDE. FIELD VERIFY. D. STANDARD COUNTERTOP DEPTH 25" INCLUDING BACKSPLASH, UNLESS OTHERWISE NOTED. PROVIDE BACKSPLASH AND SIDESPLASH AS SHOWN ON ELEVATION AT WALL JUNCTIONS. E. APPLY CLEAR SEALANT AT ALL COUNTERTOP AND BACKSPLASH JUNCTURES AND PLUMBING FIXTURE WALL JUNCTURES. F. INSTALL CASEWORK AND FINISH CARPENTRY PLUMB. LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. G. PROVIDE GROMMET SLEEVE AND CAP AT ALL GROMMET LOCATIONS AS SHOWN ON ELEVATIONS AND CASEWORK DRAWINGS. H. ALL WORKSURFACES / COUNTERTOPS TO RECEIVE EASED EDGE U.O.N. I. ALL EXPOSED SURFACES OF CABINETS TO BE FINISHED TO MATCH FACE. J. ALL SOLID SURFACE SINK BOWLS SHALL BE SSK-1 K. DISTANCE BETWEEN WORKSURFACE SUPPORT PANELS TO BE A MAXIMUM OF 3'-8", UNLESS SPECIFICALLY DIMENSIONED OTHERWISE. L. ALL COUNTERTOPS SHALL HAVE 2" RADIUS CORNERS UNLESS OTHERWISE NOTED. www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 INTERIOR ELEVATIONS 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 462901/2" = 1'-0"A600 EXAM WORKCOUNTER1 1/2" = 1'-0"A600 EXAM SINK CASEWORK2 1/2" = 1'-0"A600 MD NURSE EAST3 1/2" = 1'-0"A600 MD NURSE SOUTH4 1/2" = 1'-0"A600 MD NURSE WEST5 1/2" = 1'-0"A600 RECEPTION NORTH6 1/2" = 1'-0"A600 RECEPTION SOUTH7 1/2" = 1'-0"A600 RECEPTION WEST8 1/2" = 1'-0"A600 REGISTRATION EAST9 1/2" = 1'-0"A600 W&M10 1/2" = 1'-0"A600 WAITING WEST11 1/2" = 1'-0"A600 WORK ALCOVE12 # Revision Description Date Issued 06/08/21 RESILIENT WALL BASE 3/4" P. LAM. APRON SEE FLOOR PLAN FOR WALL TYPE. BACK SPLASH AND SIDE SPLASH AS INDICATED IN ELEVATIONS STAINLESS STEEL SINK. SEE MEP DRAWINGS. COUNTERTOP WITH RADIUSED EDGE, SEE ELEVATIONS FOR FINISHES. SUBSTRATE TO BE MARINE-GRADE PLYWOOD 2X4 FIRE RETARDANT TREATED WOOD BLOCKING BETWEEN STUDS, AT ALL MOUNTING POINTS, TYP. WOOD FRAMING AS REQ'D TO PROVIDE FOR SOLID SURFACE COUNTERTOP OVER CASEWORK UNIT, TYP. REMOVABLE 3/4" P. LAM. FRONT PANEL FOR ACCESS TO PLUMBING, ANCHORED TO CABINET FRAME. FAUCET, SEE MEP 3/4" P. LAM. BOTTOM ANCHORED TO CABINET FRAME. 1/4" PLYWOOD BACK PANEL.2' - 10 5/32" MIN.9"MIN.2' - 3"MIN. 8" 11" MIN. SEE ELEV.HGT. VARIES2' - 1"1 1/2"2 X 6 BLOCKING CENTERED AT MOUNTING HEIGHT OF WORKSURFACE & ANCHORED TO METAL STUDS WALL BASE AS SCHEDULEDVARIES2X4 BLOCKING P-LAM WORKSURFACE W/ 3MM PVC EDGE OR SOLID SURFACE WITH EASED EDGES, SEE ELVATIONS RAKKS BRACKET 3/4" PLYWOOD BACK PANEL FULL DRAWER EXTENSION, STOPS AND SILENCERS COUNTERTOP, BACKSPLASH, & SIDESPLASH AS NOTED IN ELEVATION 4" BRUSHED ALUMINUM PULLS (TYP) TOE-KICK WITH WALL BASE AS SCHEDULED PLASTIC LAMINATE PRINTER SHELF W/ ROLL OUT HARDWARE 1 1/2" 1 1/2"1' - 6" CLR.9" 4" BLOCKING AS REQUIRED, TYP.2' - 10"2' - 0" 2' - 1" 4"PLASTIC LAMINATE VALANCE PRINTER INTERIOR OF CABINET TO BE P.LAM TO MATCH CABINET FRONT ELECTRICAL BOX, SEE MEP HARDWARE AS SCHEDULED. SEE SPECS. GYPSUM BOARD 1/4" BACK PANEL 3/4" ADJ. SHELF, WHITE MALAMINE 3/4" PLASTIC LAMINATE DOOR FRONT NOTE: WHITE MELAMINE LAMINATED CABINET INTERIOR (TYPICAL). WALL BLOCKING WALL BLOCKING2' - 6"3/4" 1' - 2" PROVIDE CABINET DOOR HINGE RESTRICTOR AT BASE CABINETS ADJACENT TO WALLS AND/OR CABINETS. PLASTIC LAMINATE ON ALL EXPOSED SURFACES, TYP. NOTE: PROVIDE PLAM FASCIA TO CEILING 11" 4" 7" 2X WOOD BLOCKING SOLID SURFACE MATERIAL ALL EXPOSED EDGES EASED (1/8") TYP. K&V ROLL-EZY BALL BEARING SLIDING TRACK SYSTEM, RECESSED IN TRANSACTION COUNTER. 3/8" TEMPERED GLASS 1/8"1 7/8" 3 5/8" METAL STUD GYP. BOARD W/ PAINTED FINISH - SEE FINISH PLAN FOR SCHEDULED FINISH PLAM. BACKSPLASH AT WORK COUNTER 1X WOOD SUBSTRATE. PAINTED TO MATCH WALL SOLID SURFACE APRON www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 CASEWORK DETAILS 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 462903/4" = 1'-0"A702 CASEWORK DETAIL - ADA SINK6E 3/4" = 1'-0"A702 COUNTERTOP/WORKSURFACE6C 3/4" = 1'-0"A702 PRINTER BASE CABINET6B 3/4" = 1'-0" A702 TYPICAL UPPER CABINET 4E 3" = 1'-0"A702 TRANSACTION TOP W/ SLIDING GLASS4C # Revision Description Date Issued 06/08/21 ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECTT SENSOR (T=TEMP H=HUMIDITY) (P=PRES V=VAC T=TEMP) GAUGE THERMOMETER PRESSURE AND TEMPERATURE PLUG WATER PRESSURE REDUCING/REGULATING VALVE AUTOMATIC AIR VENT MANUAL AIR VENT FLOOR DRAIN FLOW METER CLEANOUT TEMPERATURE CONTROL 3-WAY 2-POSITION VALVE MECHANICAL VALVE AND FITTING SYMBOLS DESCRIPTIONSYMBOL TEMPERATURE CONTROL 2-WAY MODULATING VALVE TEMPERATURE CONTROL 2-WAY 2-POSITION VALVE TEMPERATURE CONTROL 3-WAY MODULATING VALVE CALIBRATED BALANCING VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED/FLANGED CAP CONCENTRIC REDUCER CHECK VALVE UNION STRAINER SAFETY RELIEF VALVE BUTTERFLY VALVE BALL VALVE GATE VALVE PLAN VIEW DETAIL VIEW R OR D FD SD F/SD MD DESCRIPTIONSYMBOL DESCRIPTION MECHANICAL DUCTWORK SYMBOLS SYMBOL WITH FLEX DUCT SECTION PLAN VIEW STANDARD RADIUS ELBOW WITH CENTER RADIUS EQUAL TO 1-1/2 TIMES WIDTH OF DUCT UNLESS OTHERWISE INDICATED FLAT OVAL SPIRAL DUCT (FIRST DIMENSION, SIDE SHOWN) RECTANGULAR DUCT (FIRST DIMENSION, SIDE SHOWN) SPIN-IN FITTING WITH MANUAL VOLUME DAMPER AND FLEXIBLE DUCT CONNECTION TYPICAL TERMINAL UNIT WITH REHEAT COIL GRILLE/REGISTER/DIFFUSER CONNECTION SIDEWALL SUPPLY, RETURN OR EXHAUST GRILLE DIFFUSER (NO AIRFLOW IN SHADED DIRECTION) INSULATED METAL PANEL 45 DEGREE LATERAL (ROUND OR FLAT OVAL ONLY) 90 DEGREE TEE (ROUND OR FLAT OVAL ONLY) SQUARE-TO-ROUND TRANSITION CONICAL FITTING ROUND SPIRAL DUCT 90 DEGREE ELBOW WITH TURNING VANES FLEXIBLE CONNECTION BEVELED ENTRY FITTING MANUAL VOLUME DAMPER FIRE DAMPER WITH ACCESS DOOR SMOKE DAMPER WITH ACCESS DOOR FIRE/SMOKE DAMPER WITH ACCESS DOOR DUCT TURNED UP (SOLID LINES) DUCT TURNED DOWN (DASHED LINES) R(RISE), D(DROP) SUPPLY DIFFUSER OR SUPPLY GRILLE RETURN GRILLE EXHAUST GRILLE SUPPLY, RETURN, OR EXHAUST SLOT DIFFUSER W" X H" DIA"ø AUTOMATIC MOTOR OPERATED DAMPER W "X H"ø DIA"ø W" X H" CD CPD CHWR CR CS CHWS HWS HWR DIRECTION OF PIPE SLOPE (DOWN) CONDENSATE & EQUIPMENT DRAIN CONDENSATE PUMP DISCHARGE CONDENSER WATER RETURN CONDENSER WATER SUPPLY CHILLED WATER RETURN CHILLED WATER SUPPLY HEATING WATER RETURN HEATING WATER SUPPLY HVAC PIPING SYMBOLS LINE SYMBOLS SCREENED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED AD ACCESS DOOR Ø °F A/E ACC ACCU AD ADJ AFCV AFF AFMS AGA AHU AL ANSI AO AP APD ARI AS ASHRAE ASME ASPE ASTM ATM AUTO AWWA B BCU BD BDD BHP BI BOD BOP BTUH CA CAP CAV CB CD CO2 CFM CH CHWP CHWR CHWS CO COMP COND CONV CP CPD CR CS CT CUH CWP dB DD DDC DEG DIA DISC DWH DWV DX EA EAT EC ECG EDR EER EF EFF EFT EG EMG EOM ESP ET EWT EXH F F&T FCO FCU FD FM FPB FPM FPS PHASE DEGREES FAHRENHEIT ARCHITECT/ENGINEER AIR COOLED CONDENSER AIR COOLED CONDENSING UNIT AREA DRAIN, ACCESS DOOR ADJUSTABLE, ADJACENT AIRFLOW CONTROL VALVE ABOVE FINISHED FLOOR AIRFLOW MEASURING STATION AMERICAN GAS ASSOCIATION AIR HANDLING UNIT ALUMINUM AMERICAN NATIONAL STANDARDS INSTITUTE ANALOG OUTPUT ACID PROOF, ACCESS PANEL AIR PRESSURE DROP (IN. WC) AIR CONDITIONING REFRIGERATION INSTITUTE AIR SEPARATOR AMERICAN SOCIETY OF HEATING, REFRIGERATION, AND AIR CONDITIONING ENGINEERS AMERICAN SOCIETY OF MECHANICAL ENGINEERS AMERICAN SOCIETY OF PLUMBING ENGINEERS AMERICAN SOCIETY FOR TESTING AND MATERIALS ATMOSPHERE AUTOMATIC AMERICAN WATER WORKS ASSOCIATION BOILER BLOWER COIL UNIT BALANCE DAMPER BACK-DRAFT DAMPER BRAKE HORSEPOWER OR BOILER HORSEPOWER BINARY INPUT, BACKWARD INCLINED BOTTOM OF DUCT BOTTOM OF PIPE BRITISH THERMAL UNITS PER HOUR COMPRESSED AIR CAPACITY CONSTANT AIR VOLUME CATCH BASIN OR CHILLED BEAM CONDENSATE DRAIN CARBON DIOXIDE CUBIC FEET PER MINUTE CHILLER CHILLED WATER PUMP CHILLED WATER RETURN CHILLED WATER SUPPLY CLEANOUT COMPRESSOR CONDENSER CONVECTOR CONDENSATE PUMP CONDENSATE PUMP DISCHARGE CONDENSER WATER RETURN CONDENSER WATER SUPPLY COOLING TOWER CABINET UNIT HEATER CONDENSER WATER PUMP DECIBEL DUAL DUCT DIRECT DIGITAL CONTROL DEGREE (°F) DIAMETER DISCONNECT SWITCH DOMESTIC WATER HEATER DRAIN, WASTE, AND VENT DIRECT EXPANSION EXHAUST AIR ENTERING AIR TEMPERATURE (°F) ELECTRICAL CONTRACTOR EGG-CRATE GRILLE EQUIVALENT DIRECT RADIATION ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY ENTERING FLUID TEMPERATURE (°F) EXHAUST GRILLE EXTRUDED METAL GRILLE (WELDED WIRE MESH) END OF MAIN DRIP EXTERNAL STATIC PRESSURE (IN. WC.) EXPANSION TANK ENTERING WATER TEMPERATURE (°F) EXHAUST FURNACE FLOAT AND THERMOSTATIC STEAM TRAP FLOOR CLEANOUT FAN COIL UNIT FLOOR DRAIN FACTORY MUTUAL FAN POWERED TERMINAL UNIT FEET PER MINUTE FEET PER SECOND ABBREVIATIONS AND TERMS FLOOR SINK FIRE/SMOKE DAMPER FINNED TUBE RADIATION GAGE OR GUAGE GALLON GENERAL CONTRACTOR GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE HEAD (FT.) HORSEPOWER HIGH PRESSURE STEAM RETURN HIGH PRESSURE STEAM SUPPLY HOT WATER PUMP HEATING WATER RETURN HEATING WATER SUPPLY HEAT EXCHANGER INTEGRAL FACE/BYPASS LEAVING AIR TEMPERATURE (°F) LOW PRESSURE STEAM RETURN LOW PRESSURE STEAM SUPPLY LEAVING WATER TEMPERATURE (°F) MIXED AIR MIXED AIR TEMPERATURE (°F) THOUSAND BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MEDIUM PRESSURE STEAM RETURN MEDIUM PRESSURE STEAM SUPPLY NOISE CRITERIA, NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL FIRE CODE NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE (°F) OPPOSED BLADE DAMPER OUTSIDE DIAMETER OWNER FURNISHED/CONTRACTOR INSTALLED PUMP PLUMBING CONTRACTOR PRESSURE DROP PRE-FILTER PROPYLENE GLYCOL WATER PREHEAT COIL PARTS PER MILLION PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH (ABSOLUTE) POUNDS PER SQUARE INCH (GAUGE) PACKAGED TERMINAL AIR CONDITIONER RETURN AIR RETURN AIR TEMPERATURE (°F) RETURN FAN RETURN GRILLE RELATIVE HUMIDITY REHEAT COIL RADIANT PANEL ROOFTOP UNIT SUPPLY AIR SUPPLY AIR TEMPERATURE (°F) SUPPLY DIFFUSER SEASONAL ENERGY EFFICIENCY RATIO SUPPLY GRILLE SHEETMETAL AND AIR CONDITIONING CONTRACTORS ASSOCIATION STATIC PRESSURE SUPPLY REGISTER SAFETY RELIEF VALVE STEAM VENT THERMOSTAT TEMPERATURE CONTROL CONTRACTOR TEMPERATURE DIFFERENCE TOTAL STATIC PRESSURE THERMAL EXPANSION VALVE TYPICAL UNIT HEATER UNDERWRITER'S LABORATORIES VARIABLE AIR VOLUME VOLUME DAMPER VARIABLE FREQUENCY CONTROLLER (SAME AS VFD, VSC) VARIABLE FREQUENCY DRIVE (SAME AS VFC, VSC) VARIABLE SPEED CONTROLLER (SAME AS VFC, VFD) WITH WITHOUT WET BULB TEMPERATURE (°F) WATER PRESSURE DROP (FT. HD) WATER SOURCE HEAT PUMP FS FSD FTR GA GAL GC GPD GPH GPM HD HP HPR HPS HWP HWR HWS HX IFB LAT LPR LPS LWT MA MAT MBH MC MCA MCC MD MPR MPS NC NEC NFC NFPA NIC NO NTS OA OAT OBD OD OF/CI P PC PD PF PGW PHC PPM PRV PSI PSIA PSIG PTAC RA RAT RF RG RH RHC RP RTU SA SAT SD SEER SG SMACNA SP SR SRV SV T TCC TD TSP TXV TYP UH UL VAV VD VFC VFD VSC W/ W/O WB WPD WSHP ECCENTRIC REDUCER GLOBE VALVE T STEAM TRAP VACUUM BREAKER SHEET SYMBOLS EXTENT OF DEMOLITION CONNECT TO EXISTING GENERAL MECHANICAL DEMOLITION NOTES A. CONTRACTOR TO FIELD VERIFY EXISTING DUCTWORK LOCATION, SIZE, AND ELEVATION PRIOR TO REMOVAL. COORDINATE ANTICIPATED ROUTING WITH EXISTING AND NEW DUCTWORK, PIPING, AND CONDUITS. CONTACT ENGINEER IF FIELD CONDITIONS REQUIRE ALTERNATIVE ROUTING. VERIFY THAT ALL SERVICES TO BE REMOVED DO NOT SERVE AREAS OUTSIDE INDICATED SCOPE OF WORK. B. PIPE AND DUCT ROUTINGS AND CLEARANCES INDICATED ARE BASED ON BEST AVAILABLE INFORMATION. CONTRACTOR SHALL VERIFY PIPING, DUCTWORK, ELECTRICAL, AND STRUCTURAL DETAILS OF EXISTING AND NEW INSTALLATIONS DURING AND AFTER DEMOLITION (PRIOR TO NEW INSTALLATIONS) TO DETERMINE WORK NECESSARY TO INSTALL WORK AS SHOWN AND INTENDED. CONTRACTOR SHALL CONTACT THE ENGINEER WITH ANY CONCERNS UPON COMPLETION OF THIS EFFORT. C. COORDINATE OUTAGES WITH OTHER CONTRACTORS, OWNER, AND MAINTENANCE STAFF. PROVIDE SUFFICIENT ADVANCE SCHEDULING TO MEET OCCUPANTS AND FACILITY PERSONNELS REQUIREMENTS FOR PLANNING AND COORDINATING FOR SYSTEMS WHICH MAY NOT BE EASILY INTERRUPTED. D. WHERE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION WORK IS DETERMINED TO PENETRATE EXISTING FLOORS, WALLS, CEILING, OR ROOF, THE OPENING THROUGH WHICH THE ABOVE DESCRIBED ITEM IS TO PASS MUST BE REPAIRED OR BUILT BACK BY THE CONSTRUCTION TRADE SKILLED IN THE WORK TO BE PERFORMED. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR PROCURRING THE SERVICES OF SKILLED CONTRACTOR. E. PROVIDE TEMPORARY PATCHING AS REQUIRED FOR INFECTION CONTROL AS DETERMINED BY HOSPITAL INFECTION CONTROL DEPARTMENT AND MAINTAIN EXISTING FIRE AND SMOKE RATINGS. F. WHERE PRE-DEMOLITION AIRFLOW READINGS ARE NOTED, TAKE READINGS PRIOR TO BEGINNING ANY DEMOLITION WORK OR CONSTRUCTING NEGATIVE AIR PRESSURE BARRIERS. PRE- DEMOLITION TAB WORK WILL LIKELY OCCUR AFTER NORMAL HOURS, CONFIRM WITH OWNER. G. ALL DUCTWORK, PIPING, AND EQUIPMENT INDICATED BY DASHED LINETYPE SHALL BE REMOVED AS DESCRIBED BY PLAN NOTES. REMOVE OR REUSE ASSOCIATED HANGERS. DO NOT LEAVE UNUSED EQUIPMENT ABANDONED ABOVE CEILING. ALL TERMINAL UNITS TO BE REMOVED SHALL ALSO HAVE SUPPLY DUCTS REMOVED BACK TO MAIN DUCTS AS INDICATED AND CAP SUITABLE FOR +4" W.G. REMOVE PIPING RUNOUTS BACK TO MAIN AND CAP. FOR PIPING RUNOUTS THAT ARE TO BE REUSED, REMOVE ALL CONTROL VALVES, BALANCE VALVES, STRAINERS , AND PIPING ACCESSORIES TO BRANCH SHUT-OFF VALVES. ALL EXISTING TERMINAL UNITS, DDC CONTROLLERS, ROOM PRESSURE MONITORS, AND HARDWARE TO BE REMOVED SHALL BE DONE SO IN A MANNER TO MINIMIZE DAMAGE AND OFFERED TO THE OWNER. CONTRACTOR SHALL DISCARD ALL DEVICES NOT WISHED TO BE RETAINED BY THE OWNER. GENERAL MECHANICAL NOTES A. CONTRACTOR TO INSTALL ACCESS PANELS AT ALL FIRE DAMPERS. REFER TO DETAILS AND SPECIFICATIONS FOR MINIMUM ACCESS PANEL SIZES. COORDINATE LOCATIONS TO ENSURE ACCESS PANELS ARE NOT OBSTRUCTED. B. REFER TO SCHEDULES FOR DIFFUSER AND TERMINAL UNIT RUNOUT SIZES. C. UNLESS NOTED OTHERWISE, TERMINAL UNIT DISCHARGE DUCT SHALL BE THE SAME SIZE AS THE TERMINAL UNIT DISCHARGE CONNECTION. D. LOCATE ALL TERMINAL UNITS, DAMPERS, VALVES, AND EQUIPMENT REQUIRING ACCESS IN AN UNOBSTRUCTED LOCATION ABOVE LAY-IN CEILING. COORDINATE THE INSTALLATION OF A CEILING ACCESS PANEL WITH GENERAL CONTRACTOR. E. FIELD VERIFY LOCATION OF ALL FLOOR PENETRATIONS PRIOR TO CUTTING TO ASSURE THAT NO FLOOR PENETRATION CONFLICTS WITH EXISTING BEAMS OR JOISTS. FLOOR PENETRATIONS SHALL BE ONLY THROUGH THE SLAB. DO NOT CUT THROUG BEAMS OR JOISTS. NOTIFY ARCHITECT AND ENGINEER FOR ANY REQUIRED MODIFICATIONS PRIOR TO CUTTING. F. REFER TO TERMINAL UNIT SCHEDULE FOR PIPE RUNOUT SIZES. G. MINIMUM PIPE SIZE SHALL NOT BE LESS THAN 3/4". H. ALL NEW AIR-HANDLING SYSTEMS AND ASSOCIATED DISTRIBUTION SHALL COMPLY WITH NFPA-90A. I. ALL DUCTWORK AND PIPE INSULATION SHALL BE INSTALLED CONTINUOUSLY THROUGH WALLS. OPENINGS SHALL BE FRAMED LARGE ENOUGH TO ACCOMMODATE INSULATED PIPE/DUCT. ALLOW ENOUGH ANNULAR SPACE FOR PROPER SEALANT. NON-RATED WALLS SHALL HAVE NON- COMBUSTIBLE SEALANT. RATED BARRIERS SHALL HAVE A UL-LISTED FIRESTOPPING ASSEMBLY. INSTALL FIRESTOPPING ASSEMBLY IN COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH UL-LISTED ASSEMBLY. J. COORDINATE THERMOSTATS, HUMIDISTATS, DIFFERENTIAL PRESSURE SENSORS, AND ALL OTHER WALL MOUNTED DEVICES WITH ALL DISCIPLINES PRIOR TO ROUGHING IN. K. REFER TO H801 DRAWING FOR DETAILS. WHERE APPROPRIATE, SPECIFIC DETAILS HAVE BEEN REFERENCED ON THE PLANS. IN ORDER TO MAINTAIN DRAWING CLARITY, NOT ALL DETAILS HAVE BEEN CALLED OUT BUT DO PERTAIN TO THE SCOPE OF THIS PROJECT. L. CONTRACTOR SHALL DRAIN SYSTEM PIPING AS NECESSARY. BUILDING WILL REMAIN IN OPERATION DURING CONSTRUCTION. M. PROTECT ALL SUPPLY, RETURN, AND EXHAUST AIR OPENINGS THROUGHOUT CONSTRUCTION FROM DAMAGE, DIRT, AND DEBRIS. N. CLEAN ALL SUPPLY DIFFUSERS, RETURN AIR GRILLES THAT ARE EXISTING TO REMAIN PRIOR TO PROJECT COMPLETION TO REMOVE ANY DIRT OR DEBRIS. www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Mechanical Symbols and General Notes H00110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 SECTION 23 05 00 - COMMON WORK RESULTS FOR MECHANICAL PART 1 - GENERAL 1.2 SUBMITTALS A. Operations Manual: Include the following: 1. Final processed submittals of all Division 23 specification sections. 2. Subcontractor contact list including name, phone number and e-mail contact information. 3. Field reports, including ductwork leakage testing and piping pressure testing. 4. Certifications of piping systems, equipment or systems if specified in the individual specification section. 5. Testing, adjusting and balancing reports. 6. Operations and maintenance information for all equipment. C. Processing Time: Allow enough time for submittal review, including time for resubmittals, as follows. Time for review shall commence on Engineer’s receipt of submittal. 1. Initial review: Allow 15 days for initial review of each submittal. Allow additional time if processing must be delayed to permit coordination with subsequent submittals. Engineer will advise Contractor when a submittal must be delayed for coordination. 2. Concurrent review: Where concurrent review of submittals by Architect/Engineer’s Consultants, Owner or other parties is required, allow 21 days for initial review of each submittal. D. Submittal Schedule: 1. Contractor shall submit all submittals to the Engineer for initial review within 30 days of award of contract, or within the first 10% of the duration of the project, whichever is less. Submittals which require processing completion prior to 45 days after award of contract shall be scheduled with the Engineer at least 14 days in advance of their requested due date. 1.3 DELIVERY, STORAGE, AND HANDLING A. Deliver, store and install materials and equipment (including supports and hangers) such that they are maintaining “as-new”condition (e.g. no rust) upon installation and up through the date of Substantial Completion. Account for environmental conditions of the construction site and schedule work accordingly. B. Do not allow any materials nor equipment to be stored in standing water. 1.4 COORDINATION A. Arrange for pipe spaces, chases, slots, and openings in building structure during progress of construction, to allow for HVAC installations. B. Coordinate installation of required supporting devices. C. Coordinate requirements with all trades for the location and size of access doors and frames necessary to gain access to HVAC items. Coordinate these requirements for all HVAC items that are concealed behind finished surfaces. D. Existing Utilities: Do not interrupt utilities serving facilities occupied or partially occupied by the Owner or others unless specifically allowed under the following conditions and then only after arranging to provide temporary utility services according to requirements indicated. 1. Notify Owner at least seven days in advance of proposed utility interruptions. Identify extent and duration of utility interruptions. 2. Indicate method of proposed utility interruptions in detail. 3. Do not proceed with proposed utility interruptions without Owner’s permission. E. Coordinate new installations with the existing installations which will remain in place and be reutilized or those that are abandoned in place. Provide transitions and fittings in ductwork and piping as well as extra lengths of ductwork and piping as required to route around these existing installations. Illustrate all such ductwork fittings on the sheet metal duct shop drawing submittal. Existing installations include plumbing, piping, electrical and other building systems components including, but not limited to, roof drain piping, sanitary piping, plumbing piping, fire protection piping, fire protection heads, heating and cooling water piping, condensate drains, steam and condensate return piping, conduit, cable tray, electrical pull boxes, projectors, booms, etc. Coordinate installation of above ceiling components and devices such that maintenance access is achieved at the completion of the project when all ceiling mounted components are installed. Coordinate with all trades. Ultimate responsibility for any rework required to achieve maintenance access is the responsibility of the Contractor responsible for coordination as noted in Division 1 Sections. F. Provide temporary connections to maintain existing systems in service during the construction. This may include ductwork, piping, power, controls, water, as well as other connections as required. G. Provide the Owner a schedule prior to the start of demolition with phased selected demolition identified by system and by floor. Identify required outages on the schedule and any temporary measures required to maintain existing systems in service. H. Coordinate the HVAC demolition with all aspects of demolition and temporary construction (including dust barriers) by other trades. 1.5 CONTRACT DOCUMENTS A. The drawings indicate the general arrangement and scope of the systems and shall be followed insofar as possible. If deviations from the layout are necessitated by field conditions, detailed layouts of the proposed departures shall be submitted in writing to the Engineer for approval before proceeding with the Work. B. The drawings are not intended to show every vertical offset or horizontal offset that may be necessary to complete the system or clear obstructions and/or the Work of other Contractors and other trades. Contractors shall anticipate during bidding that additional offsets may be required and include same in their proposals. C. The Drawings, Schedules and Specifications shall be considered to be cooperative and anything appearing in the Specifications that may not be indicated on the Drawings or vice-versa, shall be considered as part of the Contract and must be executed by the Contractor the same as though indicated by both. Clarify conflicting statements with the Engineer prior to submitting a bid. D. Measurements: Contractor shall make all his own measurements in the field and shall be responsible for correct fitting. He shall coordinate this Work with all other branches and trades in such a manner as to cause a minimum of conflict or delay. The Contractor shall coordinate his work in advance with all other trades and report immediately any difficulty which can be anticipated and propose solutions to resolve the potential difficulty. E. Adjustments to Work in the Field: 1. The Engineer reserves the right to make minor adjustments (maximum of 10’-0”) in location of sensors, valving, ductwork, dampers, conduit, \drains, piping, hangers and/or equipment at no additional charge if so directed prior to their installation. 2. Where the Drawings show equipment, casework, structure, fire rated construction, or the like, Contractors shall lay out the work to avoid conflicts. 3. Where offsets in piping, additional fittings, necessary drains, minor valves, traps and devices are required to complete the installation, to clear obstructions, or for the proper operation of the system (including air vents and drains), these shall be deemed to be included in the Contract and shall be furnished and installed complete by the Contractor at no additional charge. 4. Where offsets in ductwork, additional fittings, necessary transitions, minor fittings, dampers, accessories and devices are required to complete the installation, to clear obstructions, or for the proper operation of the system, these shall be deemed to be included in the Contract and shall be furnished and installed complete by the Contractor at no additional charge. F. Clearances: All installations shall be made to maintain maximum headroom and clearance around equipment. When space and/or headroom appear inadequate, the Contractor shall notify the Engineer prior to proceeding with the installation. No claims for additional compensation will be approved for failure on the part of the Contractor or his Subcontractor to comply with this requirement. PART 2 - PRODUCTS -NOT USED PART 3 - EXECUTION 3.1 HVAC DEMOLITION A. Disconnect, demolish, and remove HVAC systems, equipment, and components indicated to be removed. No equipment or components shall be abandoned in place unless specifically noted on the drawings. 1. Piping to Be Removed: Remove portion of piping indicated to be removed and cap remaining piping with same or compatible piping material. 2. Ducts to Be Removed: Remove portion of ducts indicated to be removed and cap remaining ducts with same or compatible ductwork material. Seal remaining ductwork to seal Class C. Duct tape is not permitted. 3. Equipment to Be Removed: Disconnect and remove services and remove equipment. Cap piping and ductwork as required. 4. Equipment Piping and Ductwork to Be Removed and Salvaged: Disconnect and cap services and remove equipment. Owner shall be given first right of refusal to all items removed from the Owner’s facility or property. Deliver salvaged items to Owner at location requested by Owner. 5. When removing piping and ductwork components, all accessories, hangers, insulation and hanger rods shall be removed also. 6. Provide temporary hangers for any pipe or duct to remain which has had hangers removed such that hanger spacing does not exceed 10’-0”. 7. Provide temporary hangers for any pipe or duct which was supported by a wall which was removed. 8. Locate and identify mechanical systems passing through the affected demolition area which serves other areas outside the demolition limits. Provide information to the Engineer directly of any questionable items. 9. Systems serving areas outside the work limits shall remain uninterrupted unless specifically authorized in writing by the Owner. B. If pipe, insulation, or equipment is damaged in appearance or is unserviceable due to demolition work, remove damaged or unserviceable portions and replace with new products of equal capacity and quality. C. All caps installed shall be installed and located such that the pipe or duct may be reconnected to and extended without relocation of other components while utilizing standard fittings. Coordinate with all trades such that any existing, temporary or new installations by other trades does not block access to caps. D. Confirm with the Owner, which if any, supply, return or exhaust air openings associated with systems which serve the project area may remain in use during construction. Cover all supply, return and exhaust air openings with synthetic air filter media, 1-inch thick, with non-oily tackified surface, with a dust holding capacity of at least 250 grams per square yard, an average dust spot arrestance of at least 85 percent, and a MERV rating of at least 6. Allow in the bid to replace the air filter media at least once per month and more often as required for proper operation of the fan systems. E. Removal of portions of systems which are energized or will be energized at any point during the construction project shall be accomplished by skilled trades who will be contractually engaged in connecting new work (piping, ductwork or caps thereof) to these same systems. 3.2 PIPING SYSTEMS -COMMON REQUIREMENTS A. Drawing plans, schematics, and diagrams indicate general location and arrangement of piping systems. Indicated locations and arrangements were used to size pipe and calculate friction loss, expansion, pump sizing, and other design considerations. Demo piping as indicated unless deviations to layout are approved on Coordination Drawings. 3.3 CUTTING AND PATCHING A. Refer to Division 2 for general cutting and patching requirements and procedures. B. Cut, channel and drill floors, walls, partitions, shafts, ceiling sand other surfaces required to permit electrical installations and demolition. Perform cutting by skilled mechanics of trades involved. C. Repair and refinish disturbed finish materials and other surfaces to match adjacent undisturbed surfaces. Install new fireproofing where existing firestopping has been disturbed. Repair and refinish materials and other surfaces by skilled mechanics of trades involved. 3.4 FIRESTOPPING A. Apply firestopping to penetrations of fire-rated floor and wall assemblies for all installations to restore original fire-resistance rating of assembly. Apply firestopping to structure where demolition exposes the structure. Firestopping materials and installation requirements are specified in Division 7 Section “Firestopping”. B. Apply firestopping as indicated to seal penetrations in Paragraph “Penetration Sealing”. C. Apply firestopping to all penetrations of smoke barriers. Provide an approved through penetration firestop system installed and tested in accordance with the requirements of UL 1479 for air leakage. The L rating for each firestop system shall not exceed 5.0 cfm per square foot at 0.30 inches of water in both ambient and elevated temperature tests. 3.5 PENETRATION SEALING A. Horizontal assembly penetrations of all floors, floor/ceiling assemblies and ceiling membranes of roof/ceiling assemblies shall be sealed as follows: 1. Non-fire resistance rated assemblies with non-combustible penetrating items shall utilize annular space fill or penetration firestopping. 2. Fire resistance rated assemblies shall utilize penetration firestopping. B. All enclosed spaces which house HVAC equipment shall have all penetrations of the horizontal and vertical membranes which separate the space from occupied and unoccupied building spaces sealed. C. Penetrations to be sealed shall include, at a minimum, all piping, ductwork, conduit and cabling penetrations installed. 3.6 CLEANING AND PROTECTION A. On completion of installation, inspect exposed finish. Remove burrs, dirt, paint spots and construction debris. This requirement applies for components including piping and ductwork which are located above lay-in and hard ceilings, especially their upper surfaces prone to collect dust and debris. B. Protect equipment and installations and maintain conditions to ensure that coatings, finishes, and cabinets are without damage or deterioration at time of Substantial Completion. Repair all coatings, finishes and cabinets to “as-new”conditions prior to turning project over to owner. END OF SECTION 23 05 00 SECTION 230529 -HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 -GENERAL 1.1 SUMMARY A. Section Includes: 1. Metal pipe hangers and supports. 2. Trapeze pipe hangers. 3. Thermal-hanger shield inserts. 4. Fastener systems. 5. Equipment supports. PART 2 -PRODUCTS 2.1 METAL PIPE HANGERS AND SUPPORTS A. Copper Pipe and Tube Hangers: 1. Description: MSS SP-58, Types 1 through 58, copper-plated steel, factory-fabricated components. 2. Hanger Rods: Continuous-thread rod, nuts, and washer made of stainless steel. 2.2 TRAPEZE PIPE HANGERS A. Description: MSS SP-58, Type 59, shop-or field-fabricated pipe-support assembly made from structural carbon-steel shapes with MSS SP-58 carbon-steel hanger rods, nuts, saddles, and U-bolts. 2.3 THERMAL-HANGER SHIELD INSERTS A. Insulation-Insert Material for Cold Piping: ASTM C552, Type II cellular glass with 100-psi (688-kPa) or ASTM C591, Type VI, Grade 1 polyisocyanurate with 125-psi (862-kPa) minimum compressive strength and vapor barrier. B. For Trapeze or Clamped Systems: Insert and shield shall cover entire circumference of pipe. C. For Clevis or Band Hangers: Insert and shield shall cover lower 180 degrees of pipe. D. Insert Length: Extend 2 inches (50 mm) beyond sheet metal shield for piping operating below ambient air temperature. 2.4 FASTENER SYSTEMS A. Mechanical-Expansion Anchors: Insert-wedge-type, [zinc-coated ] [stainless-]steel anchors, for use in hardened portland cement concrete; with pull-out, tension, and shear capacities appropriate for supported loads and building materials where used. 2.5 EQUIPMENT SUPPORTS A. Description: Welded, shop-or field-fabricated equipment support made from structural carbon-steel shapes. PART 3 -EXECUTION 3.1 APPLICATION A. Comply with requirements in Section 078413 "Penetration Firestopping" for firestopping materials and installation for penetrations through fire-rated walls, ceilings, and assemblies. B. Strength of Support Assemblies: Where not indicated, select sizes of components so strength will be adequate to carry present and future static loads within specified loading limits. 3.2 HANGER AND SUPPORT INSTALLATION A. Metal Pipe-Hanger Installation: Comply with MSS SP-58. Install hangers, supports, clamps, and attachments as required to properly support piping from the building structure. B. Metal Trapeze Pipe-Hanger Installation: Comply with MSS SP-58. Arrange for grouping of parallel runs of horizontal piping, and support together on field-fabricated trapeze pipe hangers. 1. Pipes of Various Sizes: Support together and space trapezes for smallest pipe size or install intermediate supports for smaller diameter pipes as specified for individual pipe hangers. 2. Field fabricate from ASTM A36/A36M, carbon-steel shapes selected for loads being supported. Weld steel according to AWS D1.1/D1.1M. C. Metal Framing System Installation: Arrange for grouping of parallel runs of piping, and support together on field-assembled strut systems. D. Thermal-Hanger Shield Installation: Install in pipe hanger or shield for insulated piping. E. Fastener System Installation: 1. Install mechanical-expansion anchors in concrete after concrete is placed and completely cured. Install fasteners according to manufacturer's written instructions. F. Install hangers and supports complete with necessary attachments, inserts, bolts, rods, nuts, washers, and other accessories. G. Equipment Support Installation: Fabricate from welded-structural-steel shapes. H. Install hangers and supports to allow controlled thermal and seismic movement of piping systems, to permit freedom of movement between pipe anchors, and to facilitate action of expansion joints, expansion loops, expansion bends, and similar units. I. Install lateral bracing with pipe hangers and supports to prevent swaying. J. Install building attachments within concrete slabs or attach to structural steel K. Load Distribution: Install hangers and supports so that piping live and dead loads and stresses from movement will not be transmitted to connected equipment. L. Pipe Slopes: Install hangers and supports to provide indicated pipe slopes and to not exceed maximum pipe deflections allowed by ASME B31.9 for building services piping. M. Insulated Piping: 1. Attach clamps and spacers to piping. a. Do not exceed pipe stress limits allowed by ASME B31.9 for building services piping. 2. Install MSS SP-58, Type 39, protection saddles if insulation without vapor barrier is indicated. Fill interior voids with insulation that matches adjoining insulation. 3. Install MSS SP-58, Type 40, protective shields on cold piping with vapor barrier. Shields shall span an arc of 180 degrees. 4. Shield Dimensions for Pipe: Not less than the following: a. NPS 1/4 to NPS 3-1/2 (DN 8 to DN 90): 12 inches (305 mm) long and 0.048 inch (1.22 mm) thick. 5. Thermal-Hanger Shields: Install with insulation same thickness as piping insulation. 3.3 EQUIPMENT SUPPORTS A. Fabricate structural-steel stands to suspend equipment from structure overhead or to support equipment above floor. B. Grouting: Place grout under supports for equipment and make bearing surface smooth. C. Provide lateral bracing, to prevent swaying, for equipment supports. 3.4 METAL FABRICATIONS A. Cut, drill, and fit miscellaneous metal fabrications for trapeze pipe hangers and equipment supports. B. Fit exposed connections together to form hairline joints. Field weld connections that cannot be shop welded because of shipping size limitations. C. Field Welding: Comply with AWS D1.1/D1.1M procedures for shielded, metal arc welding; appearance and quality of welds; and methods used in correcting welding work; and with the following: 1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals. 2. Obtain fusion without undercut or overlap. 3. Remove welding flux immediately. 4. Finish welds at exposed connections so no roughness shows after finishing and so contours of welded surfaces match adjacent contours. 3.5 ADJUSTING A. Hanger Adjustments: Adjust hangers to distribute loads equally on attachments and to achieve indicated slope of pipe. B. Trim excess length of continuous-thread hanger and support rods to 1-1/2 inches (40 mm). 3.6 HANGER AND SUPPORT SCHEDULE A. Specific hanger and support requirements are in Sections specifying piping systems and equipment. B. Comply with MSS SP-58 for pipe-hanger selections and applications that are not specified in piping system Sections. C. Use hangers and supports with galvanized metallic coatings for piping and equipment that will not have field-applied finish. D. Use nonmetallic coatings on attachments for electrolytic protection where attachments are in direct contact with copper tubing. E. Use copper-plated pipe hangers and stainless-steel attachments for copper piping and tubing. F. Use padded hangers for piping that is subject to scratching. G. Use thermal-hanger shield inserts for insulated piping and tubing. H. Horizontal-Piping Hangers and Supports: Unless otherwise indicated and except as specified in piping system Sections, install the following types: 1. Adjustable, Steel Clevis Hangers (MSS Type 1): For suspension of noninsulated or insulated, stationary pipes NPS 1/2 to NPS 30 (DN 15 to DN 750). 2. Yoke-Type Pipe Clamps (MSS Type 2): For suspension of up to 1050 deg F (566 deg C), pipes NPS 4 to NPS 24 (DN 100 to DN 600), requiring up to 4 inches (100 mm) of insulation. 3. Carbon-or Alloy-Steel, Double-Bolt Pipe Clamps (MSS Type 3): For suspension of pipes NPS 3/4 to NPS 36 (DN 20 to DN 900), requiring clamp flexibility and up to 4 inches (100 mm) of insulation. I. Hanger-Rod Attachments: Unless otherwise indicated and except as specified in piping system Sections, install the following types: 1. Steel Clevises (MSS Type 14): For 120 to 450 deg F (49 to 232 deg C) piping installations. 2. Swivel Turnbuckles (MSS Type 15): For use with MSS Type 11, split pipe rings. 3. Malleable-Iron Sockets (MSS Type 16): For attaching hanger rods to various types of building attachments. 4. Steel Weldless Eye Nuts (MSS Type 17): For 120 to 450 deg F (49 to 232 deg C) piping installations. J. Building Attachments: Unless otherwise indicated and except as specified in piping system Sections, install the following types: 1. Steel or Malleable Concrete Inserts (MSS Type 18): For upper attachment to suspend pipe hangers from concrete ceiling. 2. Center-Beam Clamps (MSS Type 21): For attaching to center of bottom flange of beams. K. Saddles and Shields: Unless otherwise indicated and except as specified in piping system Sections, install the following types: 1. Steel-Pipe-Covering Protection Saddles (MSS Type 39): To fill interior voids with insulation that matches adjoining insulation. 2. Protection Shields (MSS Type 40): Of length recommended in writing by manufacturer to prevent crushing insulation. 3. Thermal-Hanger Shield Inserts: For supporting insulated pipe. L. Comply with MSS SP-58 for trapeze pipe-hanger selections and applications that are not specified in piping system Sections. M. Use mechanical-expansion anchors instead of building attachments where required in concrete construction. END OF SECTION 230529 SECTION 230553 -IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 2 - PRODUCTS 2.1 LABELS A. Equipment Labels: Engraved, color-coded, multi-layer, multi-color laminated plastic for mechanical engraving. Include contact-type, permanent adhesive suitable for surface temperature of equipment. 1. Terminology: Match Owner’s numbering scheme or drawing schedules with unique equipment number. 2. Size: Length and width vary for required label content, but not less than 4-1/2” by 6” for equipment. 3. Thickness: Minimum 1/8”thick 4. Letters: Minimium ½”. B. General Requirements for Manufactured Pipe Labels: Preprinted, color-coded, with lettering indicating service, and showing flow direction. 1. Self-Adhesive Pipe Labels: Printed plastic with contact-type, permanent-adhesive backing. 2. Pipe Label Contents: Include identification of piping service using same designations or abbreviations as used on Drawings, pipe size, and an arrow indicating flow direction. a. Flow-Direction Arrows: Integral with piping system service lettering to accommodate both directions, or as separate unit on each pipe label to indicate flow direction. b. Lettering Size: At least 1-1/2 inches (38 mm) high. C. Duct Labels: Preprinted, color-coded with lettering indicating service. Include direction of airflow and duct service (supply, return, exhaust, etc.). Include contact-type, permanent adhesive. D. Valve Tags: Stamped or engraved with 1/4-inch (6.4-mm) letters for piping system abbreviation and 1/2-inch (13-mm) numbers. 1. Tag Material: Brass, 0.032-inch (0.8-mm) minimum thickness, and having predrilled or stamped holes for attachment hardware. 2. Fasteners: Brass wire-link or beaded chain; or S-hook. PART 3 - EXECUTION 3.1 LABEL INSTALLATION A. Install or permanently fasten labels on each major item of mechanical equipment. B. Locate equipment labels where accessible and visible. C. Install self-adhesive duct labels with permanent adhesive on air ducts in the following color codes: 1. Blue: For cold-air supply ducts. 2. Yellow: For hot-air supply ducts. 3. Green: For exhaust-, outside-, relief-, return-, and mixed-air ducts. D. Locate labels near points where ducts enter into concealed spaces and at maximum intervals of 50 FT in each space where ducts are exposed or concealed by removable ceiling system. END OF SECTION 230553 SECTION 230593 -TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 PROJECT CONDITIONS A. Full Owner Occupancy: Owner will occupy the site and existing building during entire TAB period. Cooperate with Owner during TAB operations to minimize conflicts with Owner's operations. PART 3 - EXECUTION 3.1 PREPARATION A. Prepare a TAB plan that includes strategies and step-by-step procedures. B. Complete system-readiness checks and prepare reports. 3.2 GENERAL PROCEDURES FOR TESTING AND BALANCING A. Cut insulation, ducts, pipes, and equipment cabinets for installation of test probes to the minimum extent necessary for TAB procedures. 1. After testing and balancing, patch probe holes in ducts with same material and thickness as used to construct ducts. 2. Install and join new insulation that matches removed materials. Restore insulation, coverings, vapor barrier, and finish according to Division 23 Section "HVAC Insulation." B. Mark equipment and balancing devices, including damper-control positions, valve position indicators, fan-speed-control levers, and similar controls and devices, with paint or other suitable, permanent identification material to show final settings. 3.3 GENERAL PROCEDURES FOR BALANCING AIR SYSTEMS A. Prepare schematic diagrams of systems' "as-built" duct layouts. B. Determine the best locations in main and branch ducts for accurate duct-airflow measurements. C. Locate start-stop and disconnect switches, electrical interlocks, and motor starters. D. Check dampers for proper position to achieve desired airflow path. E Check for airflow blockages. F. Verify that air duct system is sealed as specified in Division 23 Section "Metal Ducts." 3.5 TOLERANCES A. Set HVAC system's air flow rates and water flow rates within the following tolerances: 1. Air Outlets and Inlets: Plus or minus 5 percent. 2. Heating Hot-Water Flow Rate: Plus or minus 5 percent. 3.6 FINAL REPORT A. General: Prepare a certified written report; tabulate and divide the report into separate sections for tested systems and balanced systems. 1. Include a certification sheet at the front of the report's binder, signed and sealed by the certified testing and balancing engineer. 2. Include a list of instruments used for procedures, along with proof of calibration. B. Final Report Contents: In addition to certified field-report data, include the following: 1. Field test reports prepared by system and equipment installers. 2. Other information relative to equipment performance; do not include Shop Drawings and product data. C. General Report Data: In addition to form titles and entries, include the following data: 1. Title page, Name and address of the TAB contractor, Project name, Project location, Engineer's name and address, Contractor's name and address, Report date, Signature of TAB supervisor who certifies the report. 10. Table of Contents with the total number of pages defined for each section of the report. Number each page in the report. 11. Summary of contents including the following: a. Indicated versus final performance. b. Notable characteristics of systems. 12. Data for terminal units, including manufacturer's name, type, size, and fittings. 13. Notes to explain why certain final data in the body of reports vary from indicated values. D. Round, Flat-Oval, and Rectangular Duct Traverse Reports: Include a diagram with a grid representing the duct cross-section and record the following: 1. Report Data: a. System and air-handling-unit number. b. Location and zone. c. Traverse air temperature in deg F (deg C). d. Duct static pressure in inches wg (Pa). e. Duct size in inches (mm). f. Duct area in sq. ft. (sq. m). g. Indicated air flow rate in cfm (L/s). h. Indicated velocity in fpm (m/s). i. Actual air flow rate in cfm (L/s). j. Actual average velocity in fpm (m/s). k. Barometric pressure in psig (Pa). E. Air-Terminal-Device Reports: 1. Unit Data: a. System and air-handling unit identification. b. Location and zone. c. Apparatus used for test. d. Area served. e. Make. f. Number from system diagram. g. Type and model number. h. Size. i. Effective area in sq. ft. (sq. m). 2. Test Data (Indicated and Actual Values): a. Air flow rate in cfm (L/s). b. Air velocity in fpm (m/s). c. Preliminary air flow rate as needed in cfm (L/s). d. Preliminary velocity as needed in fpm (m/s). e. Final air flow rate in cfm (L/s). f. Final velocity in fpm (m/s). g. Space temperature in deg F (deg C). h. Entering-water temperature in deg F (deg C). i. Leaving-water temperature in deg F (deg C). j. Water flow in GPM. k. Balance valve position. l. Water pressure drop in feet of head or psig (kPa). m. Entering-air temperature in deg F (deg C). n. Leaving-air temperature in deg F (deg C). 3.7 ADDITIONAL TESTS A. Within 90 days of completing TAB, perform additional TAB to verify that balanced conditions are being maintained throughout and to correct unusual conditions. B. Seasonal Periods: If initial TAB procedures were not performed during near-peak summer and winter conditions, perform additional TAB during near-peak summer and winter conditions. END SECTION 230593 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 HVAC Specifications H00210300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 SECTION 23 07 13 -DUCT INSULATION PART 1 - GENERAL 1.1 SUBMITTALS A. Product Data: For each type of product indicated. Include thermal conductivity, water-vapor permeance thickness, and jackets (both factory-and field-applied if any). Submit detail application of protective shields, saddles, and inserts at hangers for each type of insulation, hangers, elbows, fittings, dampers, specialties and flanges for each type of insulation. 1.2 QUALITY ASSURANCE A. Surface-Burning Characteristics: For insulation and related materials, as determined by testing identical products according to ASTM E 84, by a testing agency acceptable to authorities having jurisdiction. 1. Insulation Installed Indoors: Flame-spread index of 25 or less, and smoke-developed index of 50 or less. 2. Insulation Installed Outdoors: Flame-spread index of 75 or less, and smoke-developed index of 150 or less. PART 2 - PRODUCTS 2.1 INSULATION MATERIALS A. Mineral-Fiber Blanket Insulation: Mineral or glass fibers bonded with a thermosetting resin. Comply with ASTM C 553, Type III with factory-applied FSK jacket. Factory-applied jacket requirements are specified in "Factory-Applied Jackets" Article. 1. Products: Subject to compliance with requirements, provide one of the following: a. CertainTeed Corp.; SoftTouch Duct Wrap. b. Johns Manville; Microlite. c. Knauf Insulation; Friendly Feel Duct Wrap. e. Owens Corning; SOFTR All-Service Duct Wrap. B. Mineral-Fiber Board Insulation: Mineral or glass fibers bonded with a thermosetting resin. Comply with ASTM C 612, Type IA or Type IB. For duct and plenum applications, provide insulation with factory-applied FSK jacket. Factory-applied jacket requirements are specified in "Factory-Applied Jackets" Article. 1. Products: Subject to compliance with requirements, provide one of the following: a. CertainTeed Corp.; Commercial Board. b. Fibrex Insulations Inc.; FBX. c. Johns Manville; 800 Series Spin-Glas. d. Knauf Insulation; Insulation Board. e. Owens Corning; Fiberglas 700 Series. PART 3 - EXECUTION 3.1 PREPARATION A. Surface Preparation: Clean and dry surfaces to receive insulation. Remove materials that will adversely affect insulation application. Ensure all systems to be insulated have been tested and operating satisfactorily according to the requirements listed in the document prior to proceeding. 3.2 GENERAL INSTALLATION REQUIREMENTS A. Seal joints, seams, and penetrations in insulation at hangers, supports, anchors, and other projections with vapor-barrier mastic. 1. Install insulation continuously through hangers and around anchor attachments. 2. For insulation application where vapor barriers are indicated, extend insulation on anchor legs from point of attachment to supported item to point of attachment to structure. Taper and seal ends at attachment to structure with vapor-barrier mastic. 3. Install insert materials and install insulation to tightly join the insert. Seal insulation to insulation inserts with adhesive or sealing compound recommended by insulation material manufacturer. B. Repair damaged insulation facings by applying same facing material over damaged areas. Extend patches at least 4 inches (100 mm) beyond damaged areas. Adhere, staple, and seal patches similar to butt joints. C. Insulation Installation at Interior Wall and Partition Penetrations (That Are Not Fire Rated): Install insulation continuously through walls and partitions. D. Insulation Installation at Fire-Rated Wall and Partition Penetrations (with Fire or Fire/Smoke dampers): Terminate insulation at fire damper sleeves for fire-rated wall and partition penetrations. Externally insulate damper sleeves to match adjacent insulation and overlap duct insulation at least 2 iinches (50 mm). Walls that are not required to have dampers shall be treated the same as non-rated wall and have continuous duct insulation. 1. Comply with requirements in Division 07 Section "Penetration Firestopping" firestopping and fire-resistive joint sealers. E. Blanket Insulation Installation on Ducts and Plenums: Secure with adhesive and insulation pins. 1. Install either capacitor-discharge-weld pins and speed washers or cupped-head, capacitor-discharge-weld pins on sides and bottom of horizontal ducts and sides of vertical ducts as follows: a. On duct sides with dimensions 18 inches (450 mm) and smaller, place pins along longitudinal centerline of duct. Space 3 inches (75 mm) maximum from insulation end joints, and 16 inches (400 mm) o.c. b. On duct sides with dimensions larger than 18 inches (450 mm), place pins 16 inches (400 mm) o.c. each way, and 3 inches (75 mm) maximum from insulation joints. Install additional pins to hold insulation tightly against surface at cross bracing. c. Pins may be omitted from top surface of horizontal, rectangular ducts and plenums. d. Do not over-compress insulation during installation. e. Impale insulation over pins and attach speed washers. f. Cut excess portion of pins extending beyond speed washers or bend parallel with insulation surface. Cover exposed pins and washers with tape matching insulation facing. 2. For ducts and plenums with surface temperatures below ambient, install a continuous unbroken vapor barrier. Create a facing lap for longitudinal seams and end joints with insulation by removing 2 inches (50 mm) from one edge and one end of insulation segment. Secure laps to adjacent insulation section with 1/2-inch (13-mm) outward-clinching staples, 1 inch (25 mm) o.c. Install vapor barrier consisting of factory-or field-applied jacket, adhesive, vapor-barrier mastic, and sealant at joints, seams, and protrusions. a. Repair punctures, tears, and penetrations with tape or mastic to maintain vapor-barrier seal. b. Install vapor stops for ductwork and plenums operating below 50 deg. F (10 deg. C) at 18-foot (5.5-m) intervals. Vapor stops shall consist of vapor-barrier mastic applied in a Z-shaped pattern over insulation face, along butt end of insulation, and over the surface. Cover insulation face and surface to be insulated a width equal to two times the insulation thickness, but not less than 3 inches (75 mm). 3. Insulate duct stiffeners, hangers, and flanges that protrude beyond insulation surface with 6-inch-(150-mm-) wide strips of same material used to insulate duct. Secure on alternating sides of stiffener, hanger, and flange with pins spaced 6 inches (150 mm) o.c. 3.3 INDOOR DUCT AND PLENUM INSULATION SCHEDULE A. Concealed supply-air duct insulation shall be one of the following: 1. Mineral-Fiber Blanket: 2 inches thick and 1.0-lb/cu. ft. nominal density. Increase thickness or density as required to achieve R-6.0 installed. 2. Mineral-Fiber Board: 2 inches thick and 2-lb/cu. ft. nominal density. Increase thickness or density as required to achieve R-6.0 installed. B. Concealed return-air duct insulation shall be the following: 1. Mineral-Fiber Blanket: 1-1/2 inches thick and 0.75-lb/cu. ft. nominal density. Increase thickness or density as required to achieve R-4.5 installed. 2. Mineral-Fiber Board: 1-1/2 inches thick and 2-lb/cu. ft. nominal density. Increase thickness or density as required to achieve R-4.5 installed. END SECTION 23 07 13 SPECIFICATION 230900 - INSTRUMENTATION AND CONTROL FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. This Section includes control equipment for HVAC systems and components, including control components for terminal heating and cooling units not supplied with factory-wired controls. 1.3 SYSTEM PERFORMANCE A. Comply with the following performance requirements: 1. Existing Building Management System: System to remain. New devices shall tie-into existing system. Communication speed shall be consistent with existing system capabilities. 2. Reporting Accuracy and Stability of Control: Report values and maintain measured variables within tolerances as follows: a. Water Temperature: Plus or minus 1 deg. F (0.5 deg.C). b. Water Flow: Plus or minus 5 percent of full scale. c. Water Pressure: Plus or minus 2 percent of full scale. d. Space Temperature: Plus or minus 1 deg. F (0.5 deg. C). e. Ducted Air Temperature: Plus or minus 1 deg. F (0.5 deg. C). f. Airflow (Measuring Stations): Plus or minus 5 percent of full scale. j. Airflow (Terminal): Plus or minus 10 percent of full scale. k. Air Pressure (Ducts): Plus or minus 0.1-inch wg (25 Pa). 1.4 SUBMITTALS A. Product Data: Include manufacturer's technical literature for each control device. Indicate dimensions, capacities, performance characteristics, electrical characteristics, finishes for materials, and installation and startup instructions for each type of product indicated. 1. DDC System Hardware: Bill of materials of equipment indicating quantity, manufacturer, and model number. Include technical data for operator workstation equipment, interface equipment, control units, transducers/transmitters, sensors, actuators, valves, relays/switches, control panels, and operator interface equipment. 2. Controlled Systems: Instrumentation list with element name, type of device, manufacturer, model number, and product data. Include written description of sequence of operation including schematic diagram. B. Shop Drawings: Detail equipment assemblies and indicate dimensions, weights, loads, required clearances, method of field assembly, components, and location and size of each field connection. 1. Bill of materials of equipment indicating quantity, manufacturer, and model number. 2. Schematic flow diagrams showing fans, pumps, coils, dampers, valves, and control devices. 3. Wiring Diagrams: Power, signal, and control wiring. 4. Details of control panel faces, including controls, instruments, and labeling. 5. Written description of sequence of operation. 6. Schedule of dampers including size, leakage, and flow characteristics. 7. Schedule of valves including flow characteristics. 8. DDC System Hardware: a. Wiring diagrams for control units with termination numbers. b. Schematic diagrams and floor plans for field sensors and control hardware. c. Schematic diagrams for control, communication, and power wiring, showing trunk data conductors and wiring between operator workstation and control unit locations. SPECIFICATION 230900 -INSTRUMENTATION AND CONTROL FOR HVAC (cont.) 9. Controlled Systems: a. Schematic diagrams of each controlled system with control points labeled and control elements graphically shown, with wiring. b. Scaled drawings showing mounting, routing, and wiring of elements including bases and special construction. c. Written description of sequence of operation including schematic diagram. d. Points list. 1.5 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For HVAC instrumentation and control system to include in emergency, operation, and maintenance manuals. In addition to items specified in Division 01 Section "Operation and Maintenance Data," include the following: 1. Interconnection wiring diagrams with identified and numbered system components and devices. 1.6 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, Article 100, by a testing agency acceptable to authorities having jurisdiction, and marked for intended use. B. Comply with ASHRAE 135 BACnet for DDC system components. Provide LONworks where the existing facility utilizes that communication protocol. 1.7 DELIVERY, STORAGE, AND HANDLING A. Factory-Mounted Components: Where control devices specified in this Section are indicated to be factory mounted on equipment, arrange for shipping of control devices to equipment manufacturer. B. System Software: Update to latest version of software at Project completion. 1.8 COORDINATION A. Coordinate location of thermostats, humidistats, and other exposed control sensors with plans and room details before installation. B. Coordinate equipment with Division 26 Section "Panelboards" to achieve compatibility with starter coils and annunciation devices. C. Coordinate equipment with Division 26 Section "Motor-Control Centers" to achieve compatibility with motor starters, variable frequency drives, and annunciation devices. PART 2 - PRODUCTS 2.1 CONTROL SYSTEM A. Manufacturers: Confirm allowable manufacturer/installer with owner. Manufacturer is based on the facility where the work is to occur: B. Control system shall consist of sensors, indicators, actuators, final control elements, interface equipment, other apparatus, and accessories to control mechanical systems. C. Control system shall consist of sensors, indicators, actuators, final control elements, interface equipment, other apparatus, accessories, and software connected to distributed controllers operating in multiuser, multitasking environment on token-passing network and programmed to control mechanical systems. An operator workstation permits interface with the network via dynamic color graphics with each mechanical system, building floor plan, and control device depicted by point-and-click graphics. 2.2 DDC EQUIPMENT A. Control Units: Modular, comprising processor board with programmable, nonvolatile, random-access memory; local operator access and display panel; integral interface equipment; and backup power source. 1. Units monitor or control each I/O point; process information; execute commands from other control units, devices, and operator stations; and download from or upload to operator workstation or diagnostic terminal unit. 2. Stand-alone mode control functions operate regardless of network status. Functions include the following: a. Global communications. b. Discrete/digital, analog, and pulse I/O. c. Monitoring, controlling, or addressing data points. d. Software applications, scheduling, and alarm processing. e. Testing and developing control algorithms without disrupting field hardware and controlled environment. 3. Standard Application Programs: a. Electric Control Programs: Demand limiting, duty cycling, automatic time scheduling, start/stop time optimization, night setback/setup, on-off control with differential sequencing, staggered start, anti-short cycling, PID control, DDC with fine tuning, and trend logging. b. HVAC Control Programs: Optimal run time, supply-air reset, and enthalpy switchover. d. Programming Application Features: Include trend point; alarm processing and messaging; weekly, monthly, and annual scheduling; run-time totalization. e. Remote communications. f. Maintenance management. g. Units of Measure: Inch-pound and SI (metric). 4. Local operator interface provides for download from or upload to operator workstation or diagnostic terminal unit. 5. ASHRAE 135 BACnet Compliance: Control units shall use ASHRAE 135 protocol and communicate using ISO 8802-3 (Ethernet) datalink/physical layer protocol. Utilize LONworks where the existing facility utilizes that communication protocol. B. Local Control Units: Modular, comprising processor board with electronically programmable, nonvolatile, read-only memory; and backup power source. 1. Units monitor or control each I/O point, process information, and download from or upload to operator workstation or diagnostic terminal unit. 2. Stand-alone mode control functions operate regardless of network status. Functions include the following: a. Global communications. b. Discrete/digital, analog, and pulse I/O. c. Monitoring, controlling, or addressing data points. 3. Local operator interface provides for download from or upload to operator workstation or diagnostic terminal unit. 4. ASHRAE 135 BACnet Compliance: Control units shall use ASHRAE 135 protocol and communicate using ISO 8802-3 (Ethernet) datalink/physical layer protocol. Utilize LONworks where the existing facility utilizes that communication protocol. C. I/O Interface: Hardwired inputs and outputs may tie into system through controllers. Protect points so that shorting will cause no damage to controllers. 1. Binary Inputs: Allow monitoring of on-off signals without external power. 2. Pulse Accumulation Inputs: Accept up to 10 pulses per second. 3. Analog Inputs: Allow monitoring of low-voltage (0-to 10-V dc), current (4 to 20 mA), or resistance signals. 4. Binary Outputs: Provide on-off or pulsed low-voltage signal, selectable for normally open or normally closed operation. 5. Analog Outputs: Provide modulating signal, either low voltage (0-to 10-V dc) or current (4 to 20 mA). D. Power Supplies: Transformers with Class 2 current-limiting type or overcurrent protection; limit connected loads to 80 percent of rated capacity. DC power supply shall match output current and voltage requirements and be full-wave rectifier type with the following: 1. Output ripple of 5.0 mV maximum peak to peak. 2. Combined 1 percent line and load regulation with 100-mic.sec. response time for 50 percent load changes. 3. Built-in overvoltage and overcurrent protection and be able to withstand 150 percent overload for at least 3 seconds without failure. E. Power Line Filtering: Internal or external transient voltage and surge suppression for workstations or controllers with the following: 1. Minimum dielectric strength of 1000 V. 2. Maximum response time of 10 nanoseconds. 3. Minimum transverse-mode noise attenuation of 65 dB. 4. Minimum common-mode noise attenuation of 150 dB at 40 to 100 Hz. 2.3 ELECTRONIC SENSORS A. Description: Vibration and corrosion resistant; for wall, immersion, or duct mounting as required. B. Temperature Sensors: 1. Duct sensors shall utilize averaging elements, 1000 OHM nickel Resistance Temperature Detectors (RTD) having an accuracy of ±0.5 deg. F. C. Space Sensors: 1. Space sensors located in private offices, conference rooms, other areas deemed “non-public” or as noted on the drawings shall have exposed external set-point adjustment and digital LCD display capable of displaying setpoint and actual sensed temperature. 2. Set-point adjustment to be a maximum plus and minus 4 degrees from the null setpoint programmed through the DDC system. Comply with facility standard for existing facilities. 3. Space sensors may be (RTD) 1,000 Ohm nickel with an accuracy of ±0.5 deg. F. 4. Space sensor shall be of a neutral color (white, or other customer approved color) unless noted otherwise on the Drawings. Coordinate and match other devices in the vicinity. 5. Provide insulating bases for all sensors located on exterior walls and on exterior column wraps. Foam seal cavity and junction box prior to installing insulating base. 6. Space sensors with occupant set-point adjustment shall be adjustable from the operator’s work station as to the deadband of adjustability allowed to the occupants. 2.4 ACTUATORS A. Electric Motors: Size to operate with sufficient reserve power to provide smooth modulating action or two-position action. 1. Comply with requirements in Division 23 Section "Common Motor Requirements for HVAC Equipment." 2. Permanent Split-Capacitor or Shaded-Pole Type: Gear trains completely oil immersed and sealed. Equip spring-return motors with integral spiral-spring mechanism in housings designed for easy removal for service or adjustment of limit switches, auxiliary switches, or feedback potentiometer. 3. Non-spring-Return Motors for Dampers Larger Than 25 Sq. Ft. (2.3 sq. m): Size for running torque of 150 in. x lbf (16.9 N x m) and breakaway torque of 300 in. x lbf (33.9 N x m). 4. Spring-Return Motors for Dampers Larger Than 25 Sq. Ft. (2.3 sq. m): Size for running and breakaway torque of 150 in. x lbf (16.9 N x m). B. Electronic Actuators: Direct-coupled type designed for minimum 60,000 full-stroke cycles at rated torque. 1. Manufacturers: a. Belimo, Inc. b. Honeywell c. Johnson Controls, Inc. d. Siemens 2. Control valve actuators: a. Size for valve close off at 150 percent of total system (head) pressure for two-way valves and 100 percent of pressure differential across the valve or 100 percent of total system (pump) head differential pressure for three-way valves. Chilled water pressure is approximately 150 psig. Size valves and actuators accordingly. b. Coupling: Directly couple and mount to valve stem and shaft ISO style direct-coupled mounting pad. c. Shall meet all the requirements of 2.15.B Electronic Actuators. 3. Coupling: V-bolt dual nut clamp with a V-shaped, toothed cradle. 4. Mounting: Actuators shall be direct shaft mount type. Actuators shall be capable of being mechanically and electrically paralleled to increase torque if required. 5. Overload protected electronically throughout rotation. 6. Fail safe operation: Mechanical, spring return mechanism. 7. Power requirements (spring return): 24 VAC, maximum 15 VA at 24 VAC or 8 W at 24 VDC. 8. Proportional actuators shall be fully programmable through an EEPROM without the use of actuator mounted switches. 9. Temperature rating: -22 deg. F to +122 deg. F. 10. Housing: Minimum requirement NEMA Type 2/IP54 mounted in any orientation. NEMA 4/4X (IP67) required for outdoor applications. 11. Agency listings: ISO 9001 or UL. 12. The manufacturer shall warrant all components for a period of 5 years from the date of production with the first two years unconditional. 13. All actuators shall have external adjustable stops to limit the travel in either direction and a gear release to allow manual positioning. SPECIFICATION 230900 -INSTRUMENTATION AND CONTROL FOR HVAC (cont.) 2.5 CONTROL CABLE A. Electronic and fiber-optic cables for control wiring are specified in Division 27 Section "Communications Horizontal Cabling." B. All wiring shall be plenum rated cabling. PART 3 - EXECUTION END of SECION 2309000 SECTION 233113 - METAL DUCTS PART 1 - GENERAL 1.1 SUBMITTALS A. Product Data: For each type of the following products: 1. Sealants and gaskets. 2. Seismic-restraint devices. B. Shop Drawings: 1. Fabrication, assembly, and installation, including plans, elevations, sections, components, and attachments to other work. 2. Factory-and shop-fabricated ducts and fittings. 3. Duct layout indicating sizes, configuration, liner material, and static-pressure classes. 4. Elevation of top of ducts. 5. Dimensions of main duct runs from building grid lines. 6. Fittings. 7. Reinforcement and spacing. 8. Seam and joint construction. 9. Penetrations through fire-rated and other partitions. 10. Equipment installation based on equipment being used on Project. 11. Locations for duct accessories, including dampers, turning vanes, and access doors and panels. 12. Hangers and supports, including methods for duct and building attachment[, seismic restraints,] and vibration isolation. C. Coordination Drawings: Plans, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved: 1. Duct installation in congested spaces, indicating coordination with general construction, building components, and other building services. Indicate proposed changes to duct layout. 2. Suspended ceiling components. 3. Structural members to which duct will be attached. 4. Size and location of initial access modules for acoustical tile. 5. Penetrations of smoke barriers and fire-rated construction. 6. Items penetrating finished ceiling including the following: a. Lighting fixtures. b. Air outlets and inlets. c. Speakers. d. Sprinklers. e. Access panels. f. Perimeter moldings. 2.1 SINGLE-WALL RECTANGULAR DUCTS AND FITTINGS A. General Fabrication Requirements: Comply with SMACNA's "HVAC Duct Construction Standards - Metal and Flexible" based on indicated static-pressure class unless otherwise indicated. D. Elbows, Transitions, Offsets, Branch Connections, and Other Duct Construction: Select types and fabricate according to SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Chapter 4, "Fittings and Other Construction," for static-pressure class, applicable sealing requirements, materials involved, duct-support intervals, and other provisions in SMACNA's "HVAC Duct Construction Standards -Metal and Flexible." 2.2 SINGLE-WALL ROUND AND FLAT-OVAL DUCTS AND FITTINGS A. General Fabrication Requirements: Comply with SMACNA's "HVAC Duct Construction Standards - Metal and Flexible," Chapter 3, "Round, Oval, and Flexible Duct," based on indicated static-pressure class unless otherwise indicated. 2.3 SHEET METAL MATERIALS A. General Material Requirements: Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible" for acceptable materials, material thicknesses, and duct construction methods unless otherwise indicated. Sheet metal materials shall be free of pitting, seam marks, roller marks, stains, discolorations, and other imperfections. B. Galvanized Sheet Steel: Comply with ASTM A 653/A 653M. 1. Galvanized Coating Designation: G90 (Z275). 2. Minimum sheetmetal gauge used shall not be less than 26 gauge. 2.4 SEALANT AND GASKETS A. General Sealant and Gasket Requirements: Surface-burning characteristics for sealants and gaskets shall be a maximum flame-spread index of 25 and a maximum smoke-developed index of 50 when tested according to UL723; certified by an NRTL. B. Water-Based Joint and Seam Sealant: 1. Application Method: Brush on or spray on. 2. Solids Content: Minimum 65 percent. 3. Shore A Hardness: Minimum 20. 4. Water resistant. 5. Mold and mildew resistant. 6. VOC: Maximum 75 g/L (less water). 7. Maximum Static-Pressure Class: 10-inch wg (2500 Pa), positive and negative. 8. Service: Indoor or outdoor. 9. Substrate: Compatible with galvanized sheet steel (both PVC coated and bare), stainless steel, or aluminum sheets. C. Flanged Joint Sealant: Comply with ASTM C 920. 1. General: Single-component, acid-curing, silicone, elastomeric. 2. Type: S. 3. Grade: NS. 4. Class: 25. 5. Use: O. 6. For indoor applications, sealant shall have a VOC content of 250 g/L or less when calculated according to 40 CFR 59, Subpart D (EPA Method 24). 7. Sealant shall comply with the testing and product requirements of the California Department of Health Services' "Standard Practice for the Testing of Volatile Organic Emissions from Various Sources Using Small-Scale Environmental Chambers." D. Flange Gaskets: Butyl rubber, neoprene, or EPDM polymer with polyisobutylene plasticizer. 2.5 HANGERS AND SUPPORTS A. Hanger Rods for Noncorrosive Environments: Cadmium-plated steel rods and nuts. B. Hanger Rods for Corrosive Environments: Electrogalvanized, all-thread rods or galvanized rods with threads painted with zinc-chromate primer after installation. C. Strap and Rod Sizes: Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Table 5-1 (Table 5-1M), "Rectangular Duct Hangers Minimum Size," and Table 5-2, "Minimum Hanger Sizes for Round Duct." D. Duct Attachments: Sheet metal screws, blind rivets, or self-tapping metal screws; compatible with duct materials. PART 3 - EXECUTION 3.1 DUCT INSTALLATION A. Drawing plans, schematics, and diagrams indicate general location and arrangement of duct system. Indicated duct locations, configurations, and arrangements were used to size ducts and calculate friction loss for air-handling equipment sizing and for other design considerations. Install duct systems as indicated unless deviations to layout are approved on Shop Drawings and Coordination Drawings. B. Install ducts according to SMACNA's "HVAC Duct Construction Standards - Metal and Flexible" unless otherwise indicated. C. Install round and flat-oval ducts in maximum practical lengths. D. Install ducts with fewest possible joints. E. Install factory-or shop-fabricated fittings for changes in direction, size, and shape and for branch connections. F. Unless otherwise indicated, install ducts vertically and horizontally, and parallel and perpendicular to building lines. G. Install ducts close to walls, overhead construction, columns, and other structural and permanent enclosure elements of building. H. Install ducts with a clearance of 1 inch (25 mm), plus allowance for insulation thickness. I. Route ducts to avoid passing through transformer vaults and electrical equipment rooms and enclosures. J. Where ducts pass through non-fire-rated interior partitions and exterior walls and are exposed to view, cover the opening between the partition and duct or duct insulation with sheet metal flanges of same metal thickness as the duct. Overlap openings on four sides by at least 1-1/2 inches (38 mm). K. Where ducts pass through fire-rated interior partitions and exterior walls, install fire dampers. Comply with requirements in Division 23 Section "Air Duct Accessories" for fire and smoke dampers. L. Protect duct interiors from moisture, construction debris and dust, and other foreign materials. Comply with SMACNA's "IAQ Guidelines for Occupied Buildings Under Construction," Appendix G, "Duct Cleanliness for New Construction Guidelines." M. Maintain covers on all installed and stored ductwork when not being actively worked on. 3.2 DUCT SEALING A. Seal ducts for duct static-pressure, seal classes, and leakage classes specified in "Duct Schedule" Article according to SMACNA's "HVAC Duct Construction Standards -Metal and Flexible." B. Seal ducts to the following seal classes according to SMACNA's "HVAC Duct Construction Standards -Metal and Flexible": 1. Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible." 2. All ductwork -SMACNA Seal Class A. www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 HVAC Specifications H00310300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 SECTION 233113 - METAL DUCTS (cont) 3.3 HANGER AND SUPPORT INSTALLATION A. Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Chapter 5, "Hangers and Supports." B. Building Attachments: Concrete inserts, powder-actuated fasteners, or structural-steel fasteners appropriate for construction materials to which hangers are being attached. 1. Where practical, install concrete inserts before placing concrete. 2. Install powder-actuated concrete fasteners after concrete is placed and completely cured. 3. Use powder-actuated concrete fasteners for standard-weight aggregate concretes or for slabs more than 4 inches (100 mm) thick. 4. Do not use powder-actuated concrete fasteners for lightweight-aggregate concretes or for slabs less than 4 inches (100 mm) thick. 5. Do not use powder-actuated concrete fasteners for seismic restraints. C. Hanger Spacing: Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Table 5-1 (Table 5-1M), "Rectangular Duct Hangers Minimum Size," and Table 5-2, "Minimum Hanger Sizes for Round Duct," for maximum hanger spacing; install hangers and supports within 24 inches (610 mm) of each elbow and within 48 inches (1200 mm) of each branch intersection. D. Hangers Exposed to View: Threaded rod and angle or channel supports. E. Support vertical ducts with steel angles or channel secured to the sides of the duct with welds, bolts, sheet metal screws, or blind rivets; support at each floor and at a maximum intervals of 16 feet (5 m). F. Install upper attachments to structures. Select and size upper attachments with pull-out, tension, and shear capacities appropriate for supported loads and building materials where used. 3.4 CONNECTIONS A. Make connections to equipment with flexible connectors complying with Division 23 Section "Air Duct Accessories." B. Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible" for branch, outlet and inlet, and terminal unit connections. 3.7 START UP A. Air Balance: Comply with requirements in Division 23 Section "Testing, Adjusting, and Balancing for HVAC." 3.8 DUCT SCHEDULE A. Fabricate ducts with galvanized sheet steel: B. Supply Ducts: 1. Ducts Connected to Constant-Air-Volume Air-Handling Units a. Pressure Class: Positive 4-inch wg b. Minimum SMACNA Seal Class: A. c. SMACNA Leakage Class for Rectangular: 3. d. SMACNA Leakage Class for Round and Flat Oval: 3. B. Return Ducts: 1. Ducts Connected to Air-Handling Units a. Pressure Class: Positive or negative 2-inch wg. b. Minimum SMACNA Seal Class: A c. SMACNA Leakage Class for Rectangular: 6. d. SMACNA Leakage Class for Round and Flat Oval: 6. C. Elbow Configuration: 1. Rectangular Duct: Comply with SMACNA's "HVAC Duct Construction Standards - Metal and Flexible," Figure 4-2, "Rectangular Elbows." a. Radius Type RE 1 with minimum 1.5 radius-to-diameter ratio. b. Radius Type RE 3 with minimum 1.0 radius-to-diameter ratio and two vanes. c. Mitered Type RE 2 with vanes complying with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Figure 4-3, "Vanes and Vane Runners," and Figure 4-4, "Vane Support in Elbows." 2. Rectangular Duct: Comply with SMACNA's "HVAC Duct Construction Standards - Metal and Flexible," Figure 4-2, "Rectangular Elbows." a. Radius Type RE 1 with minimum 1.5 radius-to-diameter ratio. b. Radius Type RE 3 with minimum 1.0 radius-to-diameter ratio and two vanes. c. Mitered Type RE 2 with vanes complying with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Figure 4-3, "Vanes and Vane Runners," and Figure 4-4, "Vane Support in Elbows." 3. Round Duct: Comply with SMACNA's "HVAC Duct Construction Standards - Metal and Flexible," Figure 3-4, "Round Duct Elbows." a. Minimum Radius-to-Diameter Ratio and Elbow Segments: Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Table 3-1, "Mitered Elbows." Elbows with less than 90-degree change of direction have proportionately fewer segments. 1) Radius-to Diameter Ratio: 1.5. b. Round Elbows, 12 Inches (305 mm) and Smaller in Diameter: Stamped or pleated. c. Round Elbows, 14 Inches (356 mm) and Larger in Diameter: Standing seam. D. Branch Configuration: 1. Rectangular Duct: Comply with SMACNA's "HVAC Duct Construction Standards - Metal and Flexible," Figure 4-6, "Branch Connection." a. Rectangular Main to Rectangular Branch: 45-degree entry. b. Rectangular Main to Round Branch: Spin in. 2. Round and Flat Oval: Comply with SMACNA's "HVAC Duct Construction Standards -Metal and Flexible," Figure 3-5, "90 Degree Tees and Laterals," and Figure 3-6, "Conical Tees." Saddle taps are permitted in existing duct. a. Velocity 1000 fpm (5 m/s) or Lower: 90-degree tap. b. Velocity 1000 to 1500 fpm (5 to 7.6 m/s): Conical tap. c. Velocity 1500 fpm (7.6 m/s) or Higher: 45-degree lateral. END OF SECTION 233113 SECTION 233300 - AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUBMITTALS A. Product Data: For each type of product. 1.2 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: For air duct accessories to include in operation and maintenance manuals. PART 2 - PRODUCTS 2.1 MANUAL VOLUME DAMPERS A. Standard Manual Volume Dampers: 1. Manufacturers: Subject to compliance with requirements, provide products by one of the following: a. Air Balance Inc.; a division of Mestek, Inc. b. American Warming and Ventilating; a division of Mestek, Inc. c. Flexmaster U.S.A., Inc. d. Greenheck. e. METALAIRE, Inc. f. McGill AirFlow LLC. g. Nailor Industries Inc. h. Ruskin Company. 2. Standard leakage rating with linkage outside the airstream. 3. Suitable for horizontal or vertical applications. 4. Frames: a. Frame: Hat-shaped, Minimum 0.052-inch-thick. b. Mitered and welded corners. c. Flanges for attaching to walls and flangeless frames for installing in ducts. 5. Blades: a. Multiple or single blade. b. Parallel- or opposed-blade design. c. Stiffen damper blades for stability. d. Minimum 0.064 inch (1.62 mm) thick. 6. Blade Axles: Galvanized or stainless to match duct construction. 7. Bearings: a. Molded synthetic. b. Dampers in ducts with pressure classes of 3-inch wg (750 Pa) or less shall have axles full length of damper blades and bearings at both ends of operating shaft. 8. Tie Bars and Brackets: Galvanized steel. 9. Pressure classes of 3-inch w.g. or higher or for dampers larger than 14”x14”: a. Muliple opposed blade design b. Suitable for 2,000 FPM duct velocity c. End bearings or other seals for ducts with axles running the full length of the damper blades. d. Jackshaft to operate multiple section dampers from one side. e. Provide a lacking hand quadrant with 2”stand-off mounting bracket. 10. Provide stainless or aluminum materials where dampers are shown in stainless or aluminum ductwork 2.9 FLEXIBLE DUCTS A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Flexmaster U.S.A., Inc. 2. McGill AirFlow LLC. 3. Ward Industries, Inc.; a division of Hart & Cooley, Inc. B. Low Pressure, Insulated, Flexible Duct: UL 181, Class 1, 2-ply vinyl film supported by helically wound, spring-steel wire; fibrous-glass insulation; polyethylene fire retardant vapor-barrier film. 1. Pressure Rating: 4-inch wg (1000 Pa) positive and 0.5-inch wg (125 Pa) negative. 2. Maximum Air Velocity: 4000 fpm (20 m/s). 3. Temperature Range: Minus 20 to plus 175 deg F (Minus 29 to plus 79 deg C). 4. Insulation R-value: Minimum R-6 or greater to comply with ASHRAE/IESNA 90.1. C. Insulated, Flexible Duct: UL 181, Class 1, 2-ply vinyl film supported by helically wound, spring-steel wire; fibrous-glass insulation; polyethylene fire retardant vapor-barrier film. 1. Pressure Rating: 10-inch wg (2500 Pa) positive and 1.0-inch wg (250 Pa) negative. 2. Maximum Air Velocity: 4000 fpm (20 m/s). 3. Temperature Range: Minus 20 to plus 175 deg F (Minus 29 to plus 79 deg C). 4. Insulation R-Value: Minimum R-6 or greater to comply with ASHRAE/IESNA 90.1. SECTION 233300 -AIR DUCT ACCESSORIES (cont) PART 3 - EXECUTION 3.1 INSTALLATION A. Install duct accessories according to applicable details in SMACNA's "HVAC Duct Construction Standards -Metal and Flexible" for metal ducts and in NAIMA AH116, "Fibrous Glass Duct Construction Standards," for fibrous-glass ducts. B. Install duct accessories of materials suited to duct materials; use galvanized-steel accessories in galvanized-steel and fibrous-glass ducts, stainless-steel accessories in stainless-steel ducts, and aluminum accessories in aluminum ducts. C. Install volume dampers at points on supply, return, and exhaust systems where branches extend from larger ducts. Where dampers are installed in ducts having duct liner, install dampers with hat channels of same depth as liner, and terminate liner with nosing at hat channel. D. Set dampers to fully open position before testing, adjusting, and balancing. E. Install test holes at fan inlets and outlets and elsewhere as indicated. F. Connect flexible ducts to metal ducts with draw bands. Tape flex duct vapor barrier continuously with FSK tape. G. Install flexible ducts with elbow radius’ no less than 1.5 times the duct diameter. H. Support flexible ducts from structure, no from sprinkler pipe, conduits, or other above ceiling utilities, to prevent sagging and crimping. I. Install duct test holes where required for testing and balancing purposes. 3.2 FIELD QUALITY CONTROL A. Tests and Inspections: 1. Operate dampers to verify full range of movement. 2. Inspect locations of access doors and verify that purpose of access door can be performed. 3. Inspect turning vanes for proper and secure installation. END OF SECTION 233300 www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 HVAC Specifications H00410300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 1 F G F.9 G.1 .9 1 1 1 1 2 1 1 4 3 TYP. E.5 225 CFM 250 CFM 250 CFM 300 CFM 400 CFM 200 CFM 250 CFM 130 CFM 110 CFM 315 CFM 315 CFM 250 CFM 250 CFM 250 CFM VAV-48 6 400 CFM 110 CFM 400 CFM 2 E-20 VAV-47 VAV-46 VAV-45 3 3 3 1 F G F.9 G.1 .9 5 TYP. E.5 TT T T T E-20 VAV-47 VAV-45 VAV-48 5 5 8 7 5 5 5 1 F G F.9 G.1 .9 E.5 VAV-47 E-20 VAV-46 VAV-48 VAV-45 6 6 6 7 5 4 11 4 4 4 10 26 28 2 8 2 5 10 R1 D1-30 D1-70 6"ø 3 14 15 9 16 2 15 R1 1 F G F.9 G.1 .9 1 E.5 T T TT 1 1 1 1 1 12 12 12 12 T 13VAV-45 E-20 VAV-47 VAV-48 VAV-46 NORTH www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IKEY PLAN -NOT TO SCALE AREA OF WORK April 9, 2021 First Floor HVAC Plans H10110300 N. ILLINOIS ST.INDIANAPOLIS, IN 462901/8" = 1'-0"1 First Floor HVAC Ductwork Demolition Plan 1/8" = 1'-0"2 First Floor HVAC Piping Demolition Plan DEMOLITION PLAN NOTES 1 PRIOR TO ANY DEMOLITION WORK CONDUCT AIRFLOW TESTING ON TERMINAL BOXES AND ASSOCIATED DIFFUSERS. 2 DISCONNECT EXISTING LINEAR DIFFUSER AND PREPARE FOR RECONNECTION. 3 REMOVE EXISTING RETURN GRILLE WITH LINED TRANSFER AIR BOOT AND PREPARE FOR RECONNECTION. 4 DEMO EXISTING EXHAUST DUCT, CEILING GRILLE, AND ASSOCIATED HANGERS. PREPARE FOR NEW CONNECTION. 5 EXISTING FINNED TUBE RADIATION IS TO REMAIN AND NO WORK IN PROJECT SCOPE, PROTECT DURING CONSTRUCTION FROM DAMAGE AND DEBRIS. 6 EXISTING TRANSFER DUCT TO REMAIN. 7 EXISTING TEMPERATURE SENSOR SHALL BE DISCONNECTED AND PREPARED FOR REINSTALLATION. 8 PROTECT EXISTING TEMPERATURE SENSOR DURING CONSTRUCTION. 1/8" = 1'-0"3 First Floor HVAC Ductwork Plan 1/8" = 1'-0"4 First Floor HVAC Piping Plan PLAN NOTES 1 EXISTING FINNED TUBE RADIATION IS TO REMAIN AND NO WORK IN PROJECT SCOPE, PROTECT DURING CONSTRUCTION FROM DAMAGE AND DEBRIS. 2 CLEAN LINEAR DIFFUSER AND REINSTALL IN NEW CEILING GRID. SEE DETAIL 2 ON H901 FOR LINEAR SLOT DIFFUSER DETAIL. 3 EXHAUST GRILLE RELOCATED FROM DEMOLISHED PATIENT RESTROOM AND REINSTALL IN NEW CEILING GRID. BALANCE TO 80 CFM. 4 CLEAN RETURN AIR GRILLE AND REINSTALL IN NEW CEILING GRID. 5 BALANCE DIFFUSER TO 260 CFM. 6 BALANCE DIFFUSER TO 250 CFM. 7 REVISE AIRFLOW SETPOINTS FOR TERMINAL BOX VAV-47 TO MAXIMUM: 1000 CFM, MINIMUM: 500 CFM. 8 BALANCE DIFFUSER TO 130 CFM. 9 REVISE AIRFLOW SETPOINTS FOR TERMINAL BOX VAV-46 TO MAXIMUM: 520 CFM AND MINIMUM: 370 CFM. 10 BALANCE DIFFUSER TO 300 CFM. 11 BALANCE DIFFUSER TO 140 CFM. 12 EXISTING TEMPERATURE SENSOR TO REMAIN. VERIFY CONTROL TEMPERAURE SETPOINTS AND ADJUST TO HEATING SETPOINT: 70 DEG F AND COOLING SETPOINT TO 74 DEG F. SOME TEMPERATURE SENSORS WITHIN THE GI SUITE HAD DEFAULT TEMPERATURE TO 76 DEG F AND CONTROL SETPOINTS WILL NEED CORRECTED WITHIN THE SCOPE OF THIS PROJECT. 13 RELOCATE EXISTING TEMPERATURE SENSOR CONTROLLING TERMINAL BOX E-20. VERIFY CONTROL TEMPERATURE SETPOINTS AND ADJUST HEATING SETPOINT TO 70 DEG F AND COOLING SETPOINT TO 74 DEG F. 14 24"X8" TRANSFER DUCT ABOVE FINISHED CEILING. LINE TRANSFER DUCT WITH 3/4" ARMAFLEX INSULATION. SIZE NOTED IS FREE AREA IN TRANSFER DUCT. 15 SEE DETAIL 1 ON H901 FOR RETURN GRILLE WITH SOUND BOOT. 16 REVISE VAV-45 BOX AIRFLOWS, MAXIMUM: 600 CFM AND MINIMUM: 350 CFM. 17 VERIFY AIRFLOW SETPOINTS ON TERMINAL BOX VAV-48 MAXIMUM: 630 CFM, MINIMUM: 315 CFM. 18 VERIFY AIR FLOW SETPOINTS ON TERMINAL BOX E-20 HAS AIRFLOW SET TO CONSTANT VOLUME OF 240 CFM. 17 18 # Revision Description Date Issued 06/08/21 GRILLE SCHEDULE TAG NOM SIZE NECK MAX NC TYPE MFR MODEL FINISH NOTES R1 24 x 12 - 20 EGGCRATE GRILLE PRICE 80 WHITE 1 , 2 NOTES: 1.CONFIRM FINAL FINISHES WITH ARCHITECT. 2.PROVIDE FRAME STYLE APPROPRIATE FOR CEILING TYPE (I.E. LAY-IN, SURFACE MOUNT, SIDEWALL, ETC.) REFER TO DRAWINS AND ARCHITECTURAL CEILING PLANS FOR LOCATIONS. COLOR AND FINISH TO BE APPROVED BY ARCHITECT. AIR CHANGE SCHEDULE ROOM NUMBER ROOM NAME AREA (SQ. FT) OCCUPANTS CEILING HEIGHT (FT.) % OA ROOM CLASSIFICATION ASHRAE 170 - 2017 2012 MECHANICAL CODE / ASHRAE 62.1 MINIMUM AIR VOLUME MAXIMUM AIR VOLUME EXHAUSTMIN OA ACH REQ'D MIN AIRFLOW ACH REQUIRED PRESSURE RELATIONSHIP TO ADJACENT AREAS ALL ROOM EXHAUSTED DIRECTLY OUTDOORS OUTDOOR AIRFLOW RATE (CFM/PERSON) OUTDOOR AIRFLOW RATE (CFM/SQ FT) MINIMUM OUTSIDE AIR OA SUPPLIED SPACE AIRFLOW OA ACH ACH AIRFLOW OA ACH ACH 1 WAITING 348 5 11 19% RECEPTION AREA - - - - 5 0.06 57 60 315 0.9 4.9 630 1.9 9.9 2 OFFICE 95 1 8.5 19% OFFICE - - - - 5 0.06 13 32 165 2.3 12.3 250 3.5 18.6 3 RECEPTION 175 4 11 19% RECEPTION AREA - - - - 5 0.06 38 47.8 250 1.5 7.8 500 3.0 15.6 4 MD NURSE 163 4 8.5 19% OFFICE - - - - 5 0.06 37 47.8 250 2.1 10.8 500 4.1 21.7 5 W&M 133 0 10 19% CORRIDOR - - - - 0 0.06 10 6.7 35 0.3 1.6 35 0.3 1.6 6 PATIENT RR 53 0 8.5 19% TOILET ROOM - 10 NEGATIVE YES - - - 15.3 80 - 10.7 - - - 80 7 EXAM 1 113 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 35.3 185 2.2 11.6 260 3.1 16.2 8 EXAM 2 122 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 35.3 185 2.0 10.7 260 2.9 15.0 9 EXAM 3 117 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 33.4 175 2.0 10.6 300 3.5 18.1 10 STORAGE 33 0 8.5 19% CLEAN LINEN STORAGE 0 2 POSITIVE NR 5 0.06 2 5.7 30 1.2 6.4 20 0.8 4.3 11 EXAM 4 94 2 8.5 19% GENERAL EXAM 2 4 NR NR - - - 26.7 140 2.0 10.5 140 2.0 10.5 12 WORK ALCOVE 90 1 8.5 19% OFFICE - - - - 5 0.06 13 13.0 68 1.0 5.3 70 1.0 5.5 1 2 DUCTWORK/DIFFUSER SHALL BE SUPPORTED INDEPENDENTLY FROM STRUCTURE (NOT SUPPORTED BY CEILING) INSIDE OF PLENUM TO BE PAINTED FLAT BLACK. INSULATED FLEXIBLE DUCTWORK ADJUST AIR FLOW SLOTS PER SCHEDULE AND PLANS. PLAN NOTES 1. A MAXIMUM OF FIVE (5) FEET LENGTH OF FLEXIBLE DUCT SHALL BE PROVIDED TO EACH DIFFUSER. DUCTWORK SHALL CONTAIN 180° OF BENDING. FLEX DUCT SHALL NOT CONTACT CEILING AND SHALL BE PROPERLY SUPPORTED SO AS TO HAVE NO KINKS. 2. TIE-WRAP CONNECT FLEX DUCT HELICAL COIL TO ROUND METAL DIFFUSER NECK AND TO ROUND METAL DUCTWORK AT OTHER END OF FLEX DUCT. PULL FLEX DUCT VAPOR BARRIER OVER LOWER TIE-WRAP AND INSTALL SECOND TIE-WRAP OVER THE VAPOR BARRIER. INSULATE METAL DUCT OR DIFFUSER OVER TOP OF SECOND TIE-WRAP AND INSTALL INSULATOR'S TAPE ON EDGES. ROUND BRANCH DUCT TO MAIN (SEE SCHEDULE FOR SIZE) PLENUM BOX HEIGHT = ROUND DUCT DIAMETER + 4" SLOT DIFFUSER (THREE SLOT SHOWN) EXTERNALLY INSULATE PLENUM. INTERNAL INSULATION IS NOT ALLOWED. RETURN GRILLE 8" SHEETMETAL DUCT BOOT. COVER INSIDE WITH 3/4" ARMAFLEX INSULATION. CEILING SUPPORT ROD 24" SUPPORT RETURN GRILLE AND SOUND BOOT FROM STRUCTURE ABOVE. MINIMUM 8" OR HIGHER TO CLEAR LIGHTS AND ASSOCIATED ACCESS ABOVE LIGHTS.8" www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 HVAC Schedules and Details H80110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued NO SCALE2LINEAR SLOT DIFFUSER DETAIL NO SCALE3RETURN GRILLE WITH SOUND BOOT DETAIL 06/08/21 ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECTNT CONNECTION OF NEW WORK TO EXISTING DETAIL WITH TOP LETTER INDICATING DETAIL DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT DETAIL IS REFERENCED ON OR DRAWING THAT DETAIL IS DRAWN ON SECTION WITH TOP NUMBER INDICATING SECTION DESIGNATION AND BOTTOM NUMBER INDICATING DRAWING THAT SECTION IS CUT ON OR DRAWING THAT SECTION IS DRAWN ON A. GENERAL NOTE 1 FLOOR PLAN SYMBOLS PLAN NOTE THERMOSTAT -"N" INDICATING NIGHT SETBACK THERMOSTAT H HUMIDISTAT 1. PLAN NOTE LIST ABBREV. A/E AC OR ACU ACCU AD ADJ AFCV AFF AFMS AHU APD APPROX AR ARCH AS ATM AV AVMS AW B BCU BDD BHP BI BLDG BOT BP BST BTU BTUH CA CAP CAV CC CCP CDS CENTRIF CFM CFOI CH CI CO CO2 COL COM COMP CONC CONN CONST CONT CP CPD CUH CW CWM CWP CWR CWS D DB DC DCV DCWBP DD DDC DE DEFL DEG DEPT DHWBP DI DIA DISC DISCH DS DSWBP DUC DWG DW DWBP DWH EA EAT EBH EC ECC ECG ED EDC EER EF EFT EG ELEC ELEV EMER EMG ENCL ENTR EOM EQA EQAC EQAI EQUIP EQV EQVP EQV V ERP ES ESP ET EUH EW EWC EWT EXH EXIST EXT F F&B F&T F/A F/SD FC FCU FD FH ABBREV. FHC FIN FLA FLR FODT FOP FOR FOS FOST FOV FP FPB FPC FPM FPS FPST FS FT FTG FTR G GA GAL GALV GC GH GPH GPM GV H HC HCP HD HE HGT HO HOA HORZ HOSP HP HPR HPS HR HRC HTR HVAC HW HWC HWCP HWP HWR HWS HX HZ IA IAC IAD ID IFB IHOM IN INCL INSUL INT INV I.P.S. ISOL JT KAIC KEC KW L LAC LAD LAN LAT LAV LBD LBS LD LF LFD LFT LOC LPR LPS LVG LVP LWT MA MAC MAD MAI MAT MAX MB MBH MC MCA MCC MD MECH MFR MH MIN MISC MOCP MPSR MPS MTD MV MVP N NA NC NIC NM NO NOM NTS O OA OAT ABBREV. OC OD OFCI OFOI OM OPER OPNG OSD P PC PD PE PF PG PHC PIV PLT POC PPH PPM PRD PREFAB PRES PRV PSI PSIG PVC RA RAD RAT R/H RD REC RECIR REF RF RG RH RHC RLA RM ROM ROP ROST RP RPG RPM RPZ REQ'D RV S SA SB SC SCC SCCH SCFM SCH SCW SD SEC SENS SEP SF SG SHT SHW SK SMBH SMC SP SPEC SQ SQFT SRV ST STD STM STR STRUCT SV SW SYS SZ T TB TCC TDH TDV TEMP THW TLL TMV TMBH TSP TW UH UNO UR UVL V VAC VAV VB VD VEL VSC VTR V V W WAGD WB W/ W/O WC WCO WFMD WG WGT WH WM WP WPD WS # DESCRIPTION ARCHITECT AND ENGINEER AIR CONDITIONING UNIT OR AIR COMPRESSOR AIR COOLED CONDENSING UNIT ACCESS DOOR ADJUSTABLE OR ADJACENT AIRFLOW CONTROL VALVE ABOVE FINISHED FLOOR AIR FLOW MEASURING STATION AIR HANDLING UNIT AIR PRESSURE DROP APPROXIMATE AIR RECEIVER ARCHITECT AIR SEPARATOR ATMOSPHERE ACID VENT AIR VOLUME MEASURING STATION ACID WASTE BOILER BLOWER COIL UNIT BACKDRAFT DAMPER BRAKE HORSEPOWER BACKWARD INCLINED BUILDING BOTTOM BRINE PUMP BULK SALT STORAGE BRITISH THERMAL UNIT BTU PER HOUR COMPRESSED AIR CAPACITY CONSTANT AIR VOLUME COOLING COIL COOLING COIL PUMP CONDENSATE PUMP DISCHARGE CENTRIFUGAL CUBIC FEET PER MINUTE CONTRACTOR FURNISHED/OWNER INSTALLED CHILLER CAST IRON CLEAN OUT CARBON DIOXIDE COLUMN CARBON DIOXIDE MANIFOLD COMPRESSOR CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONDENSATE PUMP CONDENSATE PUMP DISCHARGE CABINET UNIT HEATER COLD WATER COLD WATER MAKE-UP CHILLED WATER PUMP CHILLED WATER RETURN CHILLED WATER SUPPLY DIFFUSER OR DAMPER DECIBELS OR DRY BULB DUCT COIL DOUBLE CHECK VALVE DOMESTIC COLD WATER BOOSTER PUMP DUAL DUCT DIRECT DIGITAL CONTROL DEAERATOR DEFLECTION DEGREE DEPARTMENT DOMESTIC HOT WATER BOOSTER PUMP DEIONIZED WATER DIAMETER DISCONNECT DISCHARGE DOWNSPOUT DOMESTIC SOFT WATER BOOSTER PUMP DOOR UNDER CUT DRAWING DISTILLED WATER DOMESTIC WATER BOOSTER PUMP DOMESTIC WATER HEATER EXHAUST AIR ENTERING AIR TEMPERATURE ELECTRIC BASEBOARD HEATER ELECTRICAL CONTRACTOR ENVIRONMENTAL CONTROL CONTRACTOR EGG CRATE GRILLE EXHAUST DIFFUSER ELECTRIC DUCT COIL ENERGY EFFICIENCY RATIO EXHAUST AIR FAN ENTERING FLUID TEMPERATURE EXHAUST GRILLE OR ETHYLENE GLYCOL ELECTRIC ELEVATION EMERGENCY EXTRUDED METAL GRILLE ENCLOSURE ENTERING END OF MAIN DRIP EQUIPMENT AIR EQUIPMENT AIR COMPRESSOR EQUIPMENT AIR INTAKE EQUIPMENT EQUIPMENT VACUUM EQUIPMENT VACUUM PUMP EQUIPMENT VACUUM VENT ELECTRIC RADIANT PANEL EMERGENCY SHOWER EXTERNAL STATIC PRESSURE OR ELEVATOR SUMP PUMP EXPANSION TANK ELECTRIC UNIT HEATER EMERGENCY EYEWASH ELECTRIC WATER COOLER ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR DEGREES FAHRENHEIT FACE & BYPASS FLOAT AND THERMOSTATIC TRAP FIRE ALARM FIRE AND SMOKE DAMPER FLEXIBLE CONNECTION FAN COIL UNIT FLOOR DRAIN OR FIRE DAMPER FIRE HOSE OR FUME HOOD DESCRIPTION FIRE HOSE CABINET FINISH FULL LOAD AMPS FLOOR FUEL OIL DAY TANK FUEL OIL PUMP FUEL OIL RETURN FUEL OIL SUPPLY FUEL OIL STORAGE TANK FUEL OIL VENT FIRE PROTECTION FAN POWERED BOX FIRE PROTECTION CONTRACTOR FEET PER MINUTE FEET PER SECOND FIRE PROTECTION STORAGE TANK FLOW SWITCH FEET OR FLASH TANK FOOTING OR FITTING FIN TUBE RADIATION GAS, NATURAL GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GRAVITY HOOD GALLONS PER HOUR GALLONS PER MINUTE GAS NATURAL VENT HUMIDIFIER, HUMIDITY OR HEIGHT HEATING COIL HEATING COIL PUMP (HOT WATER) HEAD HEAT EXCHANGER HEIGHT HUB OUTLET HAND-OFF-AUTOMATIC HORIZONTAL HOSPITAL HORSEPOWER OR HEATPUMP HIGH PRESSURE CONDENSATE RETURN HIGH PRESSURE STEAM HOUR HEAT RECOVERY COIL HEATER HEATING, VENTILATION AND AIR CONDITIONING DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRC HOT WATER CIRCULATING PUMP HEATING HOT WATER PUMP HEATING HOT WATER RETURN HEATING HOT WATER SUPPLY HEAT EXCHANGER HERTZ INSTRUMENT AIR INSTRUMENT AIR COMPRESSOR INSTRUMENT AIR DRYER, EQAD INSIDE DIAMETER OR DIMENSION INTEGRAL FACE AND BYPASS IN-HOUSE OXYGEN MANIFOLD INCHES INCLUDE INSULATED INTERIOR INVERT INTERNATIONAL PIPE SIZING ISOLATION JOINT SHORT CIRCUIT RATING KITCHEN EQUIPMENT CONTRACTOR KILOWATTS LENGTH LAB AIR COMPRESSOR LAB AIR DRYER LOCAL AREA NETWORK LEAVING AIR TEMPERATURE LAVATORY LINEAR BAR DIFFUSER POUNDS LINEAR DIFFUSER LINEAR FOOT LAMINAR FLOW DIFFUSER LEAVING FLUID TEMPERATURE LOCATION LOW PRESSURE CONDENSATE RETURN LOW PRESSURE STEAM LEAVING LAB VACUUM PUMP LEAVING WATER TEMPERATURE MEDICAL AIR MEDICAL AIR COMPRESSOR MEDICAL AIR DRYER MEDICAL AIR INTAKE MIXED AIR TEMPERATURE MAXIMUM MOP BASIN BTU/HR X 1000 MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MOTORIZED DAMPER MECHANICAL MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MAXIMUM OVERCURRENT PROTECTION MEDIUM PRESSURE CONDENSATE RETURN MEDIUM PRESSURE STEAM MOUNTED MEDICAL VACUUM MEDICAL VACUUM PUMP NORTH OR NITROGEN NOT APPLICABLE NORMALLY CLOSED OR NOISE CRITERIA NOT IN CONTRACT NITROGEN MANIFOLD NORMALLY OPEN, NITROUS OXIDE, OR NUMBER NOMINAL OR NITROUS OXIDE MANIFOLD NOT TO SCALE OXYGEN OUTSIDE AIR OUTSIDE AIR TEMPERATURE DESCRIPTION ON CENTER OUTSIDE DIAMETER OWNER FURNISHED/CONTRACTOR INSTALLED OWNER FURNISHED/OWNER INSTALLED OXYGEN MANIFOLD OPERATOR OPENING OPEN SITE DRAIN PUMP, PNEUMATIC OR PRESSURE PLUMBING CONTRACTOR PRESSURE DROP OR PERFORATED DIFFUSER PNEUMATIC ELECTRIC PREFILTERS PROPYLENE GLYCOL PREHEAT COIL POST INDICATOR VALVE PLASTER TRAP POINT OF CONNECTION POUNDS PER HOUR PARTS PER MILLION PRESSURE RELIEF DOOR PREFABRICATED PRESSURE PRESSURE REDUCING VALVE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE POLYVINYL CHLORIDE RETURN AIR OR RELIEF AIR RADIATED RETURN AIR TEMPERATURE REHEAT ROOF DRAIN RECEIVER RECIRCULATING REFRIGERATOR RETURN AIR FAN RETURN GRILLE RELIEF HOOD OR RELATIVE HUMIDITY REHEAT COIL RUNNING LOAD AMPS ROOM REVERSE OSMOSIS VENT REVERSE OSMOSIS PUMP REVERSE OSMOSIS STORAGE TANK RADIANT PANELS RETURN PERFORATED GRILLE REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW REQUIRED ROOF VENTILATOR SANITARY OR SEWER SUPPLY AIR OR SOUND ATTENUATOR STEAM BOILER STEAM COIL STEAM CONDENSATE COOLER SUBCOOLED CHILLER STANDARD CUBIC FEET PER MINUTE SCHEDULE SOFT COLD WATER (DOMESTIC) SUPPLY DIFFUSER OR SMOKE DAMPER SECTION SENSIBLE SEWAGE EJECTOR PUMP SUPPLY AIR FAN SUPPLY GRILLE SHEET SOFT HOT WATER SINK SENSIBLE MBH SHEET METAL CONTRACTOR STATIC PRESSURE OR STORM PUMP SPECIFICATIONS SQUARE SQUARE FEET SAFETY RELIEF VALVE STEAM TRAP STANDARD STORM STARTER STRUCTURAL STEAM VENT SWITCH SYSTEM SPRINKLER ZONE THERMOSTAT TERMINAL BOX TEMPERATURE CONTROL CONTRACTOR TOTAL DISCHARGE HEAD TRIPLE DUTY VALVE TEMPERATURE TEMPERED HOT WATER TEMPERATURE LOW LIMIT THERMOSTAT MIXING VALVE TOTAL MBH TOTAL STATIC PRESSURE TEMPERED WATER UNIT HEATER UNLESS NOTED OTHERWISE URINAL ULTRA VIOLET LIGHT VENT VACUUM VARIABLE AIR VOLUME VACUUM BREAKER VOLUME DAMPER (MANUAL) VELOCITY VARIABLE SPEED CONTROLLER VENT THROUGH ROOF VACUUM VENT WASTE, WATTS OR WIDTH WASTE ANESTHESIA GAS DISPOSAL PUMP WET BULB WITH WITHOUT WATER CLOSET OR WATER COLUMN WALL CLEAN OUT WATER FLOW MEASURING DEVICE WATER GAUGE WEIGHT WALL HYDRANT WATER METER WEATHERPROOF WATER PRESSURE DROP WATER SOFTENER POUND ACD AIR CONDITIONING CONDENSATE DRAIN MECHANICAL AND PLUMBING ABBREVIATIONS PLUMBING PIPING SYMBOLSVALVE AND FITTING SYMBOLS CALIBRATED BALANCE VALVE PIPING FLEXIBLE CONNECTION PIPE TURNED UP (UNLESS NOTED OTHERWISE) PIPE TURNED DOWN PIPE OUT TOP PIPE OUT BOTTOM THREADED NIPPLE W/CAP PIPE WITH BLIND FLANGE CONCENTRIC REDUCER ECCENTRIC REDUCER CHECK VALVE UNION GATE VALVE BALL VALVE GLOBE VALVE BUTTERFLY VALVE TEMPERATURE CONTROL -2 WAY MODULATING VALVE TEMPERATURE CONTROL -2 WAY 2 POSITION MODULATING VALVE TEMPERATURE CONTROL -3 WAY MODULATING VALVE TEMPERATURE CONTROL -3 WAY 2 POSITION MODULATING VALVE SAFETY RELIEF VALVE STRAINER FLOW METER FLOOR DRAIN ZONE CONTROL VALVE (OS&Y) AUTOMATIC FLOW CONTROL VALVE FLOW MEASURING DEVICE MANUAL AIR RELIEF VENT AUTOMATIC AIR RELIEF VENT LUBRICATED PLUG VALVE STEAM PRESSURE REDUCING VALVE ANGLE VALVE GAS PRESSURE RELIEF VALVE REFRIGERANT HOT GAS BY-PASS VALVE SHUT-OFF COCK (HYDRONICS) SOLENOID VALVE REFRIGERANT EXPANSION VALVE WATER PRESSURE REDUCING/REGULATING VALVE COMBINATION WATER PRESSURE RELIEF AND REDUCING VALVE STEAM TRAP DIELECTRIC UNION BETWEEN STEEL AND COPPER STRAINER (STEAM) PRESSURE AND TEMPERATURE PLUG REFRIGERANT SIGHT GLASS THERMOMETER (P=PRESS V=VAC T=TEMP) GAUGE SENSOR (T-TEMP H-HUMIDITY) FLOW SWITCH CLEAN OUT WATER HAMMER ARRESTOR OR ALARM PRESSURE/VACUUM SWITCH INDICATED EXPANSION LOOP (COLD SPRUNG) ANCHOR GUIDE REDUCED PRESSURE BACKFLOW PREVENTER ATMOSPHERIC VACUUM BREAKER PRESSURE VACUUM BREAKER REFRIGERANT SHUT-OFF VALVE DOMESTIC WATER TEMPERATURE REGULATING VALVE EXPANSION JOINT DIFFERENTIAL SWITCH∆T P A T T A NO NCNO NC DETAIL VIEW PLAN VIEWS A101 1 TYP 1 A101 TYP TAGS V1 V2 V3 V4 V5 V6 V7 V8 V9 V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24 V25 V26 V27 V28 V29 V30 V31 V32 V33 V34 V35 V36 V37 V38 V39 V40 V41 V42 V43 V44 V45 V46 V47 V48 V49 V50 V51 V52 V53 V54 V55 V56 V57 V58 V59 V60 TYP TYPICAL CV CENTRAL VACUUM CENTRAL VACUUM OUTLETV61 GENERAL NOTES 1. ALL CONTRACT DOCUMENTS (SPECIFICATIONS AND DRAWINGS) ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. 2. ALL CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENGINEERS ATTENTION IN ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK. 3. THE CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS AND ACCESSORIES TO CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE INCLUDED IN THE COST OF THIS PROJECT. 4. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR MAY AT THEIR OPTION MODIFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS SET OF CONSTRUCTION DOCUMENTS. 5. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS. 6. ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS AND/OR STRUCTURAL MEMBERS FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE PROVIDED AS PART OF THE SCOPE OF THIS PROJECT. 7. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL. 8. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND REQUIREMENTS. 9. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE LOCATION OF THE WORK BEING INSTALLED. 10. ALL PLUMBING EQUIPMENT, PIPING, FIXTURES, AND PIPE ACCESSORIES SHALL BE NSF 61, ANNEX G COMPLIANT. 11. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25/50 FLAME SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR FURTHER CLARIFICATION. 12. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHER TIGHT BY THE APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. 13. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST CROSS BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON-STRUCTURAL ITEM. 14. DO NOT WELD OR DRILL INTO STRUCTURAL STEEL OR JOIST; INSTEAD USE CLAMPS, TIE WIRE, THRU-BOLTS WITH WASHERS 15. DO NOT USE ANY PVC, PLASTIC, ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED. ALL WOOD BLOCKING AND NAILERS, CONCEALED OR NOT SHALL BE FIRE RETARDANT TREATED. 16. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING; ROUTE THROUGH ROOF USING GENERAL CONTRACTOR'S ROOFING CONTRACTOR. 17. VENT THROUGH ROOF INSTALLATION; ALL ROOFING WORK SHALL BE COMPLETED BY THE GENERAL CONTRACTOR'S ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. 18. PIPING BELOW GROUND SHALL BE SERVICE-WEIGHT CAST IRON OR SCHEDULE 40 PVC. NO- HUB PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE. 19 DOMESTIC WATER PIPING ABOVE GRADE SHALL BE TYPE "L" WATER TUBE. 20. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES. 21. ALL SHUT-DOWN OF UTILITIES AND FIRE PROTECTION SYSTEMS SHALL BE ARRANGED WITH NO LESS THAN SEVEN (7) DAYS NOTICE TO THE OWNER. WORK MAY NOT COMMENCE UNLESS WRITTEN APPROVAL IS PROVIDED BY THE OWNER. 22. ALL DOMESTIC WATER BRANCH PIPES SERVING FIXTURES OR EQUIPMENT WITH FAST ACTING OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS. 23. ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN. (REQUIRED TO COMPLETE THE SCOPE OF WORK) DOMESTIC COLD WATER DOMESTIC HOT WATER RETURN DOMESTIC HOT WATER FIRE PROTECTION NATURAL GAS SANITARY 6" DCW 6" DHW 6" DHWR 6" FP 6" NG VENT 6" S 6" V www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Plumbing Symbols and General Notes P00110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 PLUMBING FIXTURE SCHEDULE FIXTURE REFERENCE MANUFACTURE REFERENCE MODEL WATER USAGE CONNECTION SIZES NOTES WASTE VENT HOT WATER COLD WATER TEPID WATER WC-1 (FIXTURE)AMERICAN STANDARD 3461.001 - 3" 2" - - - AMERICAN DISABILITIES ACT (ADA) INSTALL PER THE REQUIREMENTS OF THE ACCESSIBILITY GUIDELINES WC-1 (FLUSH VALVE)SLOAN 8111 1.6 GPM - - - 1" - - PLUMBING SYSTEMS PIPING PART 1 -GENERAL 1.1 SUMMARY A. SECTION INCLUDES: 1. PLUMBING SYSTEMS TO BE INSTALLED AND UTILIZED FOR DOMESTIC WATER SYSTEMS. PART 2 -PRODUCTS 2.1 PIPING MATERIALS A. POTABLE-WATER PIPING AND COMPONENTS SHALL COMPLY WITH NSF 14 AND NSF 61- G. PLASTIC PIPING COMPONENTS SHALL BE MARKED WITH "NSF-PW.", WITH SOLDER JOINTS. 2.2 COPPER TUBE AND FITTINGS -FOR DOMESTIC WATER SYSTEMS A. HARD COPPER TUBE: ASTM B 88, TYPE L ASTM B 88M, TYPE B WATER TUBE, DRAWN TEMPER. B. SOLDER FILLER METALS: ASTM B 32, LEAD-FREE ALLOYS. C. FLUX: ASTM B 813, WATER FLUSHABLE. D. SAFETY VALVES: ASME BOILER AND PRESSURE VESSEL CODE: SECTION VIII, "PRESSURE VESSELS," CONSTRUCTION; NATIONAL BOARD CERTIFIED, LABELED, AND FACTORY SEALED 1. PRESSURE SETTINGS: HIGHER THAN DISCHARGE PRESSURE AND SAME OR LOWER THAN RECEIVER PRESSURE RATING. PART 3 -EXECUTION 3.1 PIPING INSTALLATION A. ALL PLUMBING AND PIPING SYSTEMS SHALL BE INSTALLED PER THE LOCAL AND STATE PLUMBING CODE, WITH NO EXCEPTIONS. B. INSTALL COPPER TUBING ACCORDING TO CDA'S "COPPER TUBE HANDBOOK." C. INSTALL ALL FIXTURES, DRAINS AND EQUIPMENT COMPLETE TO CREATE A COMPLETE AND OPERATIONAL SYSTEM. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS AND ACCESSORIES AS REQUIRED AS PART OF THIS CONTRACT. D WHEN INSTALLING PIPING ADJACENT TO EQUIPMENT AND MACHINES, ALLOW SPACE FOR SERVICE AND MAINTENANCE. E. CONNECT DOMESTIC WATER PIPING TO WATER-SERVICE PIPING WITH SHUTOFF VALVE; EXTEND AND CONNECT TO THE FOLLOWING: 1. WATER HEATERS: COLD-WATER INLET AND HOT-WATER OUTLET PIPING IN SIZES INDICATED, BUT NOT SMALLER THAN SIZES OF WATER HEATER CONNECTIONS. 3. PLUMBING FIXTURES: COLD-AND HOT-WATER-SUPPLY PIPING IN SIZES INDICATED, BUT NOT SMALLER THAN THAT REQUIRED BY PLUMBING CODE. 4. EQUIPMENT: COLD-AND HOT-WATER-SUPPLY PIPING AS INDICATED,BUT NOT SMALLER THAN EQUIPMENT CONNECTIONS. PROVIDE SHUTOFF VALVE AND UNION FOR EACH CONNECTION. USE FLANGES INSTEAD OF UNIONS FOR NPS 2-1/2 AND LARGER. 3.2 INDOOR PIPING INSULATION SCHEDULE A. DOMESTIC HOT AND COLD WATER, PROCESS COLD AND PROCESS SOFT COLD WATER: INSULATION SHALL BE ONE OF THE FOLLOWING: 1. REFER TO PLUMBING INSULATION SCHEDULE. 3.3 FIELD QUALITY CONTROL A. PERFORM FIELD TESTS AND INSPECTIONS. B. TESTS AND INSPECTIONS: 1. PIPING LEAK TESTS: TEST NEW AND MODIFIED PARTS OF EXISTING PIPING. CAP AND FILL WITH WATER AT A PRESSURE OF 50 PSIG ABOVE SYSTEM OPERATING PRESSURE, BUT NOT LESS GREATER THAN 125 PSIG. ISOLATE TEST SOURCE AND LET STAND FOR THIRTY MINUTES; HOLD FOR TWO HOURS WITH NO DROP IN PRESSURE. 2. REPAIR LEAKS AND RETEST UNTIL NO LEAKS EXIST. 4.1 CLEANING A. CLEAN AND DISINFECT POTABLE DOMESTIC WATER PIPING AS FOLLOWS: 1. PURGE NEW PIPING AND PARTS OF EXISTING PIPING THAT HAVE BEEN ALTERED, EXTENDED, OR REPAIRED BEFORE USING. 2. USE PURGING AND DISINFECTING PROCEDURES PRESCRIBED BY AUTHORITIES HAVING JURISDICTION; IF METHODS ARE NOT PRESCRIBED, USE PROCEDURES DESCRIBED IN EITHER AWWA C651 OR AWWA C652 B. SUBMIT WATER SAMPLES IN STERILE BOTTLES TO AUTHORITIES HAVING JURISDICTION. WET-PIPE SPRINKLER SYSTEM PART 1 -GENERAL 1.1 SYSTEM DESCRIPTIONS A. WET-PIPE SPRINKLER SYSTEM: AUTOMATIC SPRINKLERS ARE ATTACHED TO PIPING CONTAINING WATER AND THAT IS CONNECTED TO WATER SUPPLY THROUGH ALARM VALVE. WATER DISCHARGES IMMEDIATLEY FROM SPRINKLERS WHEN THEY ARE OPENED. SPRINKLERS OPEN WHEN HEAT MELTS FUSIBLE LINK OR DESTROYS FRANGIBLE DEVICE. HOSE CONNECTIONS ARE INCLUDED IF INDICATED. B. DRY-PIPE SPRINKLER SYSTEM: AUTOMATIC SPRINKLERS ARE ATTACHED TO A DRY PIPE FIRE SPRINKLER SYSTEM. THE DRY SYSTEM SHALL BE A UL LISTED, FM APPROVED SYSTEM CONSISTING OF VALVE, AIR COMPRESSOR, TRIM, ACCESSORIES, DETECTORS, AND ALL ASSOCIATED INTERCONNECTING WIRE. 1.2 PERFORMANCE REQUIREMENTS A. STANDARD-PRESSURE PIPING SYSTEM COMPONENT: LISTED FOR THE EXISTING MINIMUM WORKING PRESSURE OF THIS BUILDING. B. DELEGATED DESIGN: DESIGN SPRINKLER SYSTEM(S), INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER, USING PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA INDICATED. C. CONTRACTOR SHALL PERFORM FIRE-HYDRANT FLOW TEST. D. SPRINKLER SYSTEM DESIGN SHALL BE APPROVED BY AUTHORITIES HAVING JURISDICTION. E. SEISMIC PERFORMANCE: SPRINKLER PIPING SHALL WITHSTAND THE EFFECTS OF EARTHQUAKE MOTIONS DETERMINED ACCORDING TO NFPA 13 AND ASCE/SEI 7. 1.3 ACTION SUBMITTALS A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT INDICATED. B. SHOP DRAWINGS: FOR WET-PIPE SPRINKLER SYSTEMS. INCLUDE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND ATTACHMENTS TO OTHER WORK. 1. WIRING DIAGRAMS: FOR POWER, SIGNAL, AND CONTROL WIRING. 2. DELEGATED-DESIGN SUBMITTAL: FOR SPRINKLER SYSTEMS INDICATED TO COMPLY WITH PERFORMANCE REQUIREMENTS AND DESIGN CRITERIA, INCLUDING ANALYSIS DATA SIGNED AND SEALED BY THE QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION. 1.4 INFORMATIONAL SUBMITTALS A. APPROVED SPRINKLER PIPING DRAWINGS: WORKING PLANS, PREPARED ACCORDING TO NFPA 13, THAT HAVE BEEN APPROVED BY AUTHORITIES HAVING JURISDICTION, INCLUDING HYDRAULIC CALCULATIONS IF APPLICABLE. B. FIELD TEST REPORTS AND CERTIFICATES: INDICATE AND INTERPRET TEST RESULTS FOR COMPLIANCE WITH PERFORMANCE REQUIREMENTS AND AS DESCRIBED IN NFPA 13. INCLUDING "CONTRACTOR'S MATERIAL AND TEST CERTIFICATE FOR ABOVEGROUND PIPING." 1.5 CLOSEOUT SUBMITTALS A. OPERATION AND MAINTENANCE DATA. 1.6 QUALITY ASSURANCE A. INSTALLER QUALIFICATIONS: 1. INSTALLER'S RESPONSIBILITIES INCLUDE DESIGNING, FABRICATING, AND INSTALLING SPRINKLER SYSTEM AND PROVIDING PROFESSIONAL ENGINEERING SERVICES NEEDED TO ASSUME ENGINEERING RESPONSIBILITY. BASE CALCULATIONS ON RESULTS OF FIRE-HYDRANT FLOW TEST. a. ENGINEERING RESPONSIBILITY: PREPARATION OF WORKING PLANS, CALCULATIONS, AND FIELD TEST REPORTS BY A QUALIFIED PROFESSIONAL ENGINEER. B. ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, BY A QUALIFIED TESTING AGENCY, AND MARKED FOR INTENDED LOCATION AND APPLICATION. C. NFPA STANDARDS: SPRINLER SYSTEM EQUIPMENT, SPECIALTIES, ACCESSORIES, INSTALLATION, AND TESTING SHALL COMPLY WITH THE FOLLOWING: 1. NFPA 13, "INSTALLATION OF SPRINKLER SYSTEMS." PART 2 -PRODUCTS 2.1 PIPING MATERIALS A. COMPLY WITH ALL NFPA, STATE AND LOCAL REQUIREMENTS. 2.2 SPRINKLERS A. GENERAL REQUIREMENTS: 1. STANDARD: UL'S "FIRE PROTECTION EQUIPMENT DIRECTORY" LISTING OR "APPROVED GUIDE," PUBLISHED BY FM GLOBAL, LISTING. 2. PRESSURE RATING FOR AUTOMATIC SPRINKLERS: 175 PSIG MINIMUM. 3. PRESSURE RATING FOR HIGH-PRESSURE AUTOMATIC SPRINKLER: 250 PSIG. PART 3 -EXECUTION 3.1 PIPING INSTALLATION A. LOCATIONS AND ARRANGEMENTS: DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING. INSTALL PIPING AS INDICATED, AS FAR AS PRACTICAL. B. PIPING STANDARD: COMPLY WITH REQUIREMENTS FOR INSTALLATION OF SPRINKLER PIPING IN NFPA 13. C. INSTALL SEISMIC RESTRAINTS ON PIPING. COMPLY WITH REQUIREMENTS FOR SEISMIC-RESTRAINT DEVICE MATERIALS AND INSTALLATION IN NFPA 13. D. INSTALL SPRINKLER SYSTEMS PER NFPA, STATE AND LOCAL CODES. 3.2 PIPING INSTALLATION A. DRAWING PLANS, SCHEMATICS, AND DIAGRAMS INDICATE GENERAL LOCATION AND ARRANGEMENT OF PIPING SYSTEMS. INSTALL PIPING AS INDICATED UNLESS DEVIATIONS TO LAYOUT ARE REQUIRED BY BUILDING CONSTRUCTION. INDICATE DEVIATIONS ON COORDINATION DRAWINGS. SUBMIT AS-BUILT DRAWINGS TO BUILDING OWNER PRIOR TO CERTIFICATE OF OCCUPANCY. B. INSTALL PIPING IN CONCEALED LOCATIONS UNLESS OTHERWISE INDICATED AND EXCEPT IN EQUIPMENT ROOMS AND SERVICE AREAS. C. INSTALL PIPING INDICATED TO BE EXPOSED AND PIPING IN EQUIPMENT ROOMS AND SERVICE AREAS AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED OTHERWISE. D. INSTALL PIPING ABOVE ACCESSIBLE CEILINGS TO ALLOW SUFFICIENT SPACE FOR CEILING PANEL REMOVAL. E. INSTALL PIPING TO PERMIT VALVE SERVICING. F. INSTALL PIPING AT INDICATED SLOPES. G. INSTALL PIPING FREE OF SAGS AND BENDS. H. INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS. I. INSTALL PIPING TO ALLOW APPLICATION OF INSULATION. J. MAKE CHANGES IN DIRECTION FOR SOIL AND WASTE DRAINAGE AND VENT PIPING USING APPROPRIATE BRANCHES, BENDS, AND LONG-SWEEP BENDS. SANITARY TEES AND SHORT-SWEEP 1/4 BENDS MAY BE USED ON VERTICAL STACKS IF CHANGE IN DIRECTION OF FLOW IS FROM HORIZONTAL TO VERTICAL. USE LONG-TURN, DOUBLE Y- BRANCH AND 1/8-BEND FITTINGS IF TWO FIXTURES ARE INSTALLED BACK TO BACK OR SIDE BY SIDE WITH COMMON DRAIN PIPE. STRAIGHT TEES, ELBOWS, AND CROSSES MAY BE USED ON VENT LINES. DO NOT CHANGE DIRECTION OF FLOW MORE THAN 90 DEGREES. USE PROPER SIZE OF STANDARD INCREASERS AND REDUCERS IF PIPES OF DIFFERENT SIZES ARE CONNECTED. REDUCING SIZE OF DRAINAGE PIPING IN DIRECTION OF FLOW IS PROHIBITED. K. LAY BURIED BUILDING DRAINAGE PIPING BEGINNING AT LOW POINT OF EACH SYSTEM. INSTALL TRUE TO GRADES AND ALIGNMENT INDICATED, WITH UNBROKEN CONTINUITY OF INVERT. PLACE HUB ENDS OF PIPING UPSTREAM. INSTALL REQUIRED GASKETS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS FOR USE OF LUBRICANTS, CEMENTS, AND OTHER INSTALLATION REQUIREMENTS. MAINTAIN SWAB IN PIPING AND PULL PAST EACH JOINT AS COMPLETED. L. INSTALL SOIL AND WASTE DRAINAGE AND VENT PIPING AT THE FOLLOWING MINIMUM SLOPES UNLESS OTHERWISE INDICATED: 1. BUILDING SANITARY DRAIN: 2 PERCENT DOWNWARD IN DIRECTION OF FLOW FOR PIPING NPS 3 AND SMALLER; DOWNWARD IN DIRECTION OF FLOW FOR PIPING NPS 4 AND LARGER. 2. HORIZONTAL SANITARY DRAINAGE PIPING: 2 PERCENT DOWNWARD IN DIRECTION OF FLOW. 3. VENT PIPING: 1 PERCENT DOWN TOWARD VERTICAL FIXTURE VENT OR TOWARD VENT STACK. M. INSTALL CAST-IRON SOIL PIPING ACCORDING TO CISPI'S "CAST IRON SOIL PIPE AND FITTINGS HANDBOOK," CHAPTER IV, "INSTALLATION OF CAST IRON SOIL PIPE AND FITTINGS." 1. INSTALL ENCASEMENT ON UNDERGROUND PIPING ACCORDING TO ASTM A 674 OR AWWA C105/A21.5 O. INSTALL ABOVEGROUND PVC PIPING ACCORDING TO ASTM D 2665. P. INSTALL UNDERGROUND PVC PIPING ACCORDING TO ASTM D 2321. Q. DO NOT ENCLOSE, COVER, OR PUT PIPING INTO OPERATION UNTIL IT IS INSPECTED AND APPROVED BY AUTHORITIES HAVING JURISDICTION. R. INSTALL SLEEVES FOR PIPING PENETRATIONS OF WALLS, CEILINGS, AND FLOORS. COMPLY WITH REQUIREMENTS FOR SLEEVES SPECIFIED IN DIVISION 22 SECTION "SLEEVES AND SLEEVE SEALS FOR PLUMBING PIPING." S. INSTALL SLEEVE SEALS FOR PIPING PENETRATIONS OF CONCRETE WALLS AND SLABS. COMPLY WITH REQUIREMENTS FOR SLEEVE SEALS SPECIFIED IN DIVISION 22 SECTION "SLEEVES AND SLEEVE SEALS FOR PLUMBING PIPING." INSTALL ESCUTCHEONS FOR PIPING PENETRATIONS OF WALLS,. 3.7 FIELD QUALITY CONTROL A. DURING INSTALLATION, NOTIFY AUTHORITIES HAVING JURISDICTION AT LEAST 24 HOURS BEFORE INSPECTION MUST BE MADE. PERFORM TESTS SPECIFIED BELOW IN PRESENCE OF AUTHORITIES HAVING JURISDICTION. 1. ROUGHING-IN INSPECTION: ARRANGE FOR INSPECTION OF PIPING BEFORE CONCEALING OR CLOSING-IN AFTER ROUGHING-IN AND BEFORE SETTING FIXTURES. 2. FINAL INSPECTION: ARRANGE FOR FINAL INSPECTION BY AUTHORITIES HAVING JURISDICTION TO OBSERVE TESTS SPECIFIED BELOW AND TO ENSURE COMPLIANCE WITH REQUIREMENTS. B. REINSPECTION: IF AUTHORITIES HAVING JURISDICTION FIND THAT PIPING WILL NOT PASS TEST OR INSPECTION, MAKE REQUIRED CORRECTIONS AND ARRANGE FOR REINSPECTION. C. REPORTS: PREPARE INSPECTION REPORTS AND HAVE THEM SIGNED BY AUTHORITIES HAVING JURISDICTION. D. TEST SANITARY DRAINAGE AND VENT PIPING ACCORDING TO PROCEDURES OF AUTHORITIES HAVING JURISDICTION. OR, IN ABSENCE OF PUBLISHED PROCEDURES, AS FOLLOWS: 1. TEST FOR LEAKS AND DEFECTS IN NEW PIPING AND PARTS OF EXISTING PIPING THAT HAVE BEEN ALTERED, EXTENDED, OR REPAIRED. IF TESTING IS PERFORMED IN SEGMENTS, SUBMIT SEPARATE REPORT FOR EACH TEST, COMPLETE WITH DIAGRAM OF PORTION OF PIPING TESTED. 2. LEAVE UNCOVERED AND UNCONCEALED NEW, ALTERED, EXTENDED, OR REPLACED DRAINAGE AND VENT PIPING UNTIL IT HAS BEEN TESTED AND APPROVED. EXPOSE WORK THAT WAS COVERED OR CONCEALED BEFORE IT WAS TESTED. 3. ROUGHING-IN PLUMBING TEST PROCEDURE: TEST DRAINAGE AND VENT PIPING EXCEPT OUTSIDE LEADERS ON COMPLETION OF ROUGHING-IN. CLOSE OPENINGS IN PIPING SYSTEM AND FILL WITH WATER TO POINT OF OVERFLOW, BUT NOT LESS THAN 10-FOOT HEAD OF WATER. FROM 15 MINUTES BEFORE INSPECTION STARTS TO COMPLETION OF INSPECTION, WATER LEVEL MUST NOT DROP. INSPECT JOINTS FOR LEAKS. 4. FINISHED PLUMBING TEST PROCEDURE: AFTER PLUMBING FIXTURES HAVE BEEN SET AND TRAPS FILLED WITH WATER, TEST CONNECTIONS AND PROVE THEY ARE GASTIGHT AND WATERTIGHT. PLUG VENT-STACK OPENINGS ON ROOF AND BUILDING DRAINS WHERE THEY LEAVE BUILDING. INTRODUCE AIR INTO PIPING SYSTEM EQUAL TO PRESSURE OF 1-INCH WG. USE U-TUBE OR MANOMETER INSERTED IN TRAP OF WATER CLOSET TO MEASURE THIS PRESSURE. AIR PRESSURE MUST REMAIN CONSTANT WITHOUT INTRODUCING ADDITIONAL AIR THROUGHOUT PERIOD OF INSPECTION. INSPECT PLUMBING FIXTURE CONNECTIONS FOR GAS AND WATER LEAKS. 5. REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING, OR PORTION THEREOF, UNTIL SATISFACTORY RESULTS ARE OBTAINED. 6. PREPARE REPORTS FOR TESTS AND REQUIRED CORRECTIVE ACTION. 3.8 CLEANING AND PROTECTION A. CLEAN INTERIOR OF PIPING. REMOVE DIRT AND DEBRIS AS WORK PROGRESSES. B. PROTECT DRAINS DURING REMAINDER OF CONSTRUCTION PERIOD TO AVOID CLOGGING WITH DIRT AND DEBRIS AND TO PREVENT DAMAGE FROM TRAFFIC AND CONSTRUCTION WORK. C. PLACE PLUGS IN ENDS OF UNCOMPLETED PIPING AT END OF DAY AND WHEN WORK STOPS. SANITARY WASTE AND VENT SYSTEMS PIPING PART 1 -GENERAL 1.1 SUMMARY A. SECTION INCLUDES: 1. PLUMBING SYSTEMS TO BE INSTALLED AND UTILIZED FOR SANITARY WASTE AND VENT AND STORM WATER DRAINAGE SYSTEMS. 1.2 PERFORMANCE REQUIREMENTS A. COMPONENTS AND INSTALLATION SHALL BE CAPABLE OF WITHSTANDING THE FOLLOWING MINIMUM WORKING PRESSURE UNLESS OTHERWISE INDICATED: 1. SOIL, WASTE, AND VENT PIPING: 10-FOOT HEAD OF WATER 1.3 QUALITY ASSURANCE A. PIPING MATERIALS SHALL BEAR LABEL, STAMP, OR OTHER MARKINGS OF SPECIFIED TESTING AGENCY. B. COMPLY WITH NSF/ANSI 14, "PLASTICS PIPING SYSTEMS COMPONENTS AND RELATED MATERIALS," FOR PLASTIC PIPING COMPONENTS. INCLUDE MARKING WITH "NSF-DWV" FOR PLASTIC DRAIN, WASTE, AND VENT PIPING AND "NSF-SEWER" FOR PLASTIC SEWER PIPING. PART 2 -PRODUCTS 2.1 HUB-AND-SPIGOT, CAST-IRON SOIL PIPE AND FITTINGS A. PIPE AND FITTINGS: ASTM A 74, SERVICE CLASS. B. GASKETS: ASTM C 564, RUBBER. 2.2 HUBLESS, CAST-IRON SOIL PIPE AND FITTINGS A. PIPE AND FITTINGS: ASTM A 888 OR CISPI 301. B. CISPI, HUBLESS-PIPING COUPLINGS: 1. STANDARDS: ASTM C 1277 AND CISPI 310. 2. DESCRIPTION: STAINLESS-STEEL CORRUGATED SHIELD WITH STAINLESS-STEEL BANDS AND TIGHTENING DEVICES; AND ASTM C 564, RUBBER SLEEVE WITH INTEGRAL, CENTER PIPE STOP. 2.4 PVC PIPE AND FITTINGS A. SOLID-WALL PVC PIPE: ASTM D 2665, DRAIN, WASTE, AND VENT. B. CELLULAR-CORE PVC PIPE: ASTM F 891, SCHEDULE 40. C. PVC SOCKET FITTINGS: ASTM D 2665, MADE TO ASTM D 3311, DRAIN, WASTE, AND VENT PATTERNS AND TO FIT SCHEDULE 40 PIPE. D. ADHESIVE PRIMER: ASTM F 656. 2.5 ENCASEMENT FOR UNDERGROUND METAL PIPING A. STANDARD: ASTM A 674 OR AWWA C105/A 21.5. PART 3 -EXECUTION 3.1 EARTH MOVING A. COMPLY WITH REQUIREMENTS FOR EXCAVATING, TRENCHING, AND BACKFILLING SPECIFIED IN DIVISION 31 SECTION "EARTH MOVING." 3.3 JOINT CONSTRUCTION A. JOIN HUBLESS, CAST-IRON SOIL PIPING ACCORDING TO CISPI 310 AND CISPI'S "CAST IRON SOIL PIPE AND FITTINGS HANDBOOK" FOR HUBLESS-PIPING COUPLING JOINTS. C. PLASTIC, NONPRESSURE-PIPING, SOLVENT-CEMENT JOINTS: CLEAN AND DRY JOINING SURFACES. JOIN PIPE AND FITTINGS ACCORDING TO THE FOLLOWING: 1. COMPLY WITH ASTM F 402 FOR SAFE-HANDLING PRACTICE OF CLEANERS, PRIMERS, AND SOLVENT CEMENTS. 2. PVC PIPING: JOIN ACCORDING TO ASTM D 2855 AND ASTM D 2665 APPENDIXES. 3.4 HANGER AND SUPPORT INSTALLATION A. COMPLY WITH REQUIREMENTS FOR PIPE HANGER AND SUPPORT DEVICES AND INSTALLATION SPECIFIED IN DIVISION 22 SECTION "HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT." 1. INSTALL CARBON-STEEL PIPE HANGERS FOR HORIZONTAL PIPING IN NONCORROSIVE ENVIRONMENTS. 2. INSTALL CARBON-STEEL PIPE SUPPORT CLAMPS FOR VERTICAL PIPING IN NONCORROSIVE ENVIRONMENTS. 3. VERTICAL PIPING: MSS TYPE 8 OR TYPE 42, CLAMPS. 4. INSTALL INDIVIDUAL, STRAIGHT, HORIZONTAL PIPING RUNS: A. 100 FEET AND LESS: MSS TYPE 1, ADJUSTABLE, STEEL CLEVIS HANGERS. B. LONGER THAN 100 FEET: MSS TYPE 43, ADJUSTABLE ROLLER HANGERS. B. SUPPORT VERTICAL PIPING AND TUBING AT BASE AND AT EACH FLOOR. C. ROD DIAMETER MAY BE REDUCED ONE SIZE FOR DOUBLE-ROD HANGERS, WITH 3/8-INCH MINIMUM RODS. B. INSTALL HANGERS FOR CAST-IRON SOIL PIPING WITH THE FOLLOWING MAXIMUM HORIZONTAL SPACING AND MINIMUM ROD DIAMETERS: 1. NPS 1-1/2 AND NPS 2: 60 INCHES WITH 3/8-INCH ROD. 2. NPS 3: 60 INCHES WITH 1/2-INCH ROD. 3. NPS 4 AND NPS 5: 60 INCHES WITH 5/8-INCH ROD. C. INSTALL SUPPORTS FOR VERTICAL CAST-IRON SOIL PIPING EVERY 15 FEET. D. INSTALL HANGERS FOR PVC PIPING WITH THE FOLLOWING MAXIMUM HORIZONTAL SPACING AND MINIMUM ROD DIAMETERS: 1. NPS 1-1/2 AND NPS 2: 48 INCHES WITH 3/8-INCH ROD. 2. NPS 3: 48 INCHES WITH 1/2-INCH ROD. 3. NPS 4: 48 INCHES WITH 5/8-INCH ROD. E. INSTALL SUPPORTS FOR VERTICAL PVC PIPING EVERY 48 INCHES. F. SUPPORT PIPING AND TUBING NOT LISTED ABOVE ACCORDING TO MSS SP-69 AND MANUFACTURER'S WRITTEN INSTRUCTIONS. 3.5 CONNECTIONS A CONNECT DRAINAGE AND VENT PIPING TO THE FOLLOWING: 1. PLUMBING FIXTURES: CONNECT DRAINAGE PIPING IN SIZES INDICATED, BUT NOT SMALLER THAN REQUIRED BY PLUMBING CODE. 2. PLUMBING FIXTURES AND EQUIPMENT: CONNECT ATMOSPHERIC VENT PIPING IN SIZES INDICATED, BUT NOT SMALLER THAN REQUIRED BY AUTHORITIES HAVING JURISDICTION. 3. PLUMBING SPECIALTIES: CONNECT DRAINAGE AND VENT PIPING IN SIZES INDICATED, BUT NOT SMALLER THAN REQUIRED BY PLUMBING CODE. 4. INSTALL TEST TEES (WALL CLEANOUTS) IN CONDUCTORS NEAR FLOOR AND FLOOR CLEANOUTS WITH COVER FLUSH WITH FLOOR. 3.6 IDENTIFICATION A. IDENTIFY EXPOSED SANITARY WASTE AND VENT PIPING. COMPLY WITH REQUIREMENTS FOR IDENTIFICATION SPECIFIED IN DIVISION 22 SECTION "IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT." 3.2 FIELD QUALITY CONTROL A. PERFORM TESTS AND INSPECTIONS PER NFPA, STATE AND LOCAL REQUIRMENTS. 3.3 SPRINKLER SCHEDULE A. USE SPRINKLER TYPES PER NFPA REQUIREMENTS. B. PROVIDE SPRINKLER TYPES IN SUBPARAGRAPHS BELOW WITH FINISHES INDICATED. 1. CONCEALED SPRINKLERS: ROUGH BRASS, WITH FACTORY-PAINTED COVER PLATE TO MATCH THE ADJACENT SURFACE, REFER TO THE ARCHITECTURAL AND OR INTERIOR FINISH PLANS. 2. FLUSH SPRINKLERS: BRIGHT CHROME, WITH PAINTED WHITE ESCUTCHEON. 3. RECESSED SPRINKLERS: BRIGHT CHROME, WITH BRIGHT CHROME ESCUTCHEON. 4. UPRIGHT, PENDENT AND SIDEWALL SPRINKLERS: CHROME PLATED IN FINISHED SPACES EXPOSED TO VIEW; ROUGH BRONZE IN UNFINISHED SPACES NOT EXPOSED TO VIEW; WAX COATED WHERE EXPOSED TO ACIDS, CHEMICALS, OR OTHER CORROSIVE FUMES. B. USE SPRINKLER TYPES IN SUBPARAGRAPHS BELOW FOR THE FOLLOWING APPLICATIONS: 1. ROOMS WITHOUT CEILINGS: UPRIGHT SPRINKLERS. 2. ROOMS WITH SUSPENDED CEILINGS: CONCEALED SPRINKLERS. 3. WALL MOUNTING: SIDEWALL SPRINKLERS. 4. SPACES SUBJECT TO FREEZING: SIDEWALL, DRY SPRINKLERS. 5. SPECIAL APPLICATIONS: EXTENDED-COVERAGE, FLOW-CONTROL, AND QUICK- RESPONSE SPRINKLERS WHERE INDICATED. www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Plumbing Specifications and Schedules P00310300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 A. ALL CONTRACT DOCUMENTS (SPECIFICATIONS AND DRAWINGS) ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION TO OBTAIN COMPLETE CONSTRUCTION INFORMATION. ALL CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS OR ENGINEERS ATTENTION IN ORDER TO ALLOW A CLARIFICATION TO BE ISSUED. ANY WORK COMPLETED WITHOUT THE CLARIFYING INFORMATION IS AT THE CONTRACTORS FINANCIAL RISK. B. THE CONTRACTOR SHALL PROVIDE AND FURNISH ALL MATERIALS AND ACCESSORIES TO CREATE A FULLY OPERATIONAL, CODE COMPLIANT AND TESTED SYSTEM. ALL MATERIALS AND ACCESSORIES REQUIRED TO CREATE THE FULLY OPERATIONAL SYSTEM SHALL BE INCLUDED IN THE COST OF THIS PROJECT. C. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR MAY AT THEIR OPTION MODIFY THE PIPE ROUTING IN ORDER TO CREATE A SYSTEM THAT MEETS THE INTENT OF THIS SET OF CONSTRUCTION DOCUMENTS. D. THE CONTRACTOR SHALL INCLUDE ALL ITEMS THAT ARE REQUIRED TO ENSURE THAT THE ENTIRE SYSTEM IS FUNCTIONING IN COMPLIANCE WITH THE APPLICABLE CODES, AND MANUFACTURES INSTALLATION RECOMMENDATIONS AND OR REQUIREMENTS. E. ALL CUTTING, DRILLING AND PATCHING OF WALLS, FLOORS AND/OR STRUCTURAL MEMBERS FOR THE INSTALLATION OF THE PLUMBING AND FIRE PROTECTION SYSTEMS SHALL BE PROVIDED AS PART OF THE SCOPE OF THIS PROJECT. F. STRUCTURAL COMPONENTS SHALL NOT BE CUT, DRILLED OR MODIFIED IN ANY WAY WITHOUT THE STRUCTURAL ENGINEERS REVIEW AND PRIOR WRITTEN APPROVAL. G. PROVIDE FIRE STOPPING WHERE PIPES PENETRATE FIRE RATED FLOORS AND WALLS. FIRE STOPPING MATERIALS AND METHODS SHALL BE PER LOCAL AND STATE CODES AND REQUIREMENTS. H. ALL PLUMBING SYSTEMS SHALL BE INSTALLED PER THE CURRENT PLUMBING CODE FOR THE LOCATION OF THE WORK BEING INSTALLED. I. ALL PLUMBING EQUIPMENT, PIPING, FIXTURES, AND PIPE ACCESSORIES SHALL BE NSF 61, ANNEX G COMPLIANT. J. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM SHALL COMPLY WITH A 25/50 FLAME SMOKE RATING. ANY EXISTING PIPING DISCOVERED WITHIN A RETURN AIR PLENUM THAT DOES NOT COMPLY WITH THIS REQUIREMENT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR FURTHER CLARIFICATION. K. ALL EXTERIOR WALL PENETRATIONS SHALL BE SEALED WATER AND WEATHER TIGHT BY THE APPROPRIATE TRADE COMPETENT IN COMPLETING THIS WORK. THE COST OF THIS WORK SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. L. DO NOT ATTACH ANY CONSTRUCTION TO THE ROOF DECK JOIST BRIDGING, JOIST CROSS BRACING, PIPING, CONDUIT, DUCTWORK OR ANY OTHER NON-STRUCTURAL ITEM. M. DO NOT WELD OR DRILL INTO STRUCTURAL STEEL OR JOIST; INSTEAD USE CLAMPS, TIE WIRE, THRU-BOLTS WITH WASHERS N. DO NOT USE ANY PVC, PLASTIC, ETC. IN PLENUM OR DEMISING WALLS UNLESS FIRE WRAPPED. ALL WOOD BLOCKING AND NAILERS, CONCEALED OR NOT SHALL BE FIRE RETARDANT TREATED. O. DO NOT PENETRATE BUILDING WALLS FOR ANY DUCTING OR VENTING; ROUTE THROUGH ROOF USING LANDLORDS ROOFING CONTRACTOR. P. VENT THROUGH ROOF INSTALLATION; ALL ROOFING WORK SHALL BE COMPLETED BY THE LANDLORDS ROOFING CONTRACTOR. THE COST SHALL BE INCLUDED IN THE SCOPE OF THIS PROJECT. Q. PIPING BELOW GROUND SHALL BE SERVICE-WEIGHT CAST IRON OR SCHEDULE 40 PVC. NO-HUB PIPING OR FERNCO CONNECTIONS ARE NOT PERMITTED BELOW GRADE. R. DOMESTIC WATER PIPING ABOVE GRADE SHALL BE TYPE "L" WATER TUBE. S. ALL PIPING SHALL BE PROPERLY SUSPENDED BY THE STRUCTURE PER THE LOCAL CODES. T. ALL PIPING INSULATED SHALL BE WITH PLENUM RATED MATERIALS. U. FLOOR DRAINS SHALL BE PROVIDED WITH TRAP PRIMERS. TRAP PRIMER PIPES SHALL BE FIELD ROUTED AND FIELD INSTALLED. V. ALL SHUT-DOWN OF UTILITIES AND FIRE PROTECTION SYSTEMS SHALL BE ARRANGED WITH NO LESS THAN SEVEN (7) DAYS NOTICE TO THE LANDLORD. WORK MAY NOT COMMENCE UNLESS WRITTEN APPROVAL IS PROVIDED BY THE OWNER. W. ALL DOMESTIC WATER BRANCH PIPES SERVING FIXTURES OR EQUIPMENT WITH FAST ACTING OR ELECTRONIC VALVES SHALL BE PROVIDED WATER HAMMER ARRESTORS. X. ALL BRANCH PIPES FROM DOMESTIC WATER MAINS SHALL BE PROVIDED QUARTER TURN FULL PORT BALL VALVES ON THE BRANCH PIPE JUST ADJACENT TO THE MAIN. Y. CONTRACTOR SHALL CAMERA INSPECT AND LOCATE ALL SANITARY PIPE LOCATED BELOW SLAB, ADVISE OWNER OF ANY DEFECTS PRIOR TO STARING ANY WORK. ALL CAMERA INSPECTION AND LOCATING SHALL BE COMPLETED PRIOR TO INSTALLATION OF ANY PIPE. CONTRACTOR MAY MODIFY ROUTING OF PIPE, KEEP AS-BUILT DOCUMENTS THROUGHOUT THE ENTIRE PROJECT. Z. CONTRACTOR SHALL REMOVE ONLY WASTE VENT, HOT AND COLD WATER PIPE AS REQUIRED (BACK TO MAINS) TO ACCOMMODATE THE NEW FLOOR PLANS. ALL EXISTING SANITARY AND WASTE PIPE SERVING THE FLOOR ABOVE SHALL BE LEFT IN PLACE. THE CONTRACTOR SHALL FIELD MODIFY ANY EXISTING SANITARY PIPE AS REQUIRED TO ACCOMMODATE THE NEW FLOOR PLANS. GENERAL NOTES (REQUIRED TO COMPLETE THE SCOPE OF WORK)2 E.5 F F.9 G.1 .9 3 3 3 3 4 4 4 5 2 E.5 F F.9 G.1 .9 2 1 16 2 2 1 2 6 6 6 8 9 2 13 13 13 13 2 9 15 2 E.5 F F.9 G.1 .9 Standard 3" S 3" S 2" V 2" V 2" S 2" S 10 2" S2" S 2" S 14 2 E.5 F F.9 G.1 .9 1 1/2" DCW 1/2" DHW 3/4" DCW 2" V 1/2" DCW 1/2" DCW 1/2" DHW 1/2" DCW WC-1 2" V 2" V 11 11 12 12 1/2" DHW WAITING 001RECEPTION 003 OFFICE 002 MD NURSE 004 EXAM 1 007 EXAM 2 008 EXAM 3 009 EXAM 4 011 PATIENT RR 006 STORAGE 010 WORK ALCOVE 012 W&M 005 7 7 7 7 17 2" S 2" S 2" S 2" V 2" V 2" V 2" S 2" V 2" V WC-1 2" V 2" V 3" S 2" V 3" S www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 First Floor Plumbing Plans P10110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290PLAN NOTES 1 REMOVE EXISTING PLUMBING FIXTURE COMPLETE. REMOVE ALL ROUGH-IN PIPING AND ASSOCIATED ACCESSORIES COMPLETE. INCLUDING SANITARY WASTE AND VENT AND DOMESTIC WATER RISERS. 2 PLUMBING CONTRACTOR SHALL REMOVE AND SALVAGE THE EXISTING PLUMBING FIXTURE AND FACUET TO BE REINSTALLED IN NEW CASEWORK IN THE NEW EXAM ROOMS. 3 REMOVE SANITARY PIPE THROUGH FLOOR JUST BELOW SLAB AND PLUG. 4 REMOVE SECTION OF SANITARY PIPE AND PLUG BOTH ENDS. 5 CUT AND CAP EXISTING SANITARY PIPE. 6 CUT AND CAP EXISTING DHW & DCW PIPING. 7 PLUMBING CONTRACTOR SHALL SELECT FROM THE SALVAGED FIXTURES AND FAUCETS WHICH ONES ARE OF THE BETTER CONDITION AND REINSTALL AT THIS LOCATION. ANY FIXTURES AND FAUCETS NOT REUSED MAY BE DISCARDED AT THE END OF THE PROJECT. MODIFY EXISTING PLUMBING ROUGHINS AS NEEDED TO ACCOMMODATE REINSTALLED PLUMBING FIXTURES. 8 CUT AND CAP EXISTING VENT PIPE. 9 CUT EXISTING VENT PIPE AND PREP FOR RECONNECTION. 10 CONNECT 3" S TO EXISTING SANITARY PIPING. 11 CONNECT 2" V TO EXISTING VENT PIPING. 12 CONNECT 1/2" DHW & DCW PIPING TO EXISTING DWH & DCW. 13 EXISTING AREA ALREADY HAS A SPRINKLER SYSTEM IN PLACE. FP CONTRACTOR SHALL RELOCATE MAINS OR BRANCH PIPING TO ACCOMMODATE NEW ARCHITECHTURAL FLOOR PLAN AND CEILING GRID. FP CONTRACTOR SHALL PROVIDE COMPLETE AND OPERATIONAL SYSTEM PER NFPA REQUIREMENTS. 14 CONNECT 2" S TO EXISTING SANITARY PIPING. 15 CUT EXISTING 2" S PIPE AND PREP FOR RECONNECTION. PLUMBING CONTRACTOR SHALL VERIFY WHAT THIS LINE IS SERVING AND RECONNECT TO THE SANITARY WASTE AND VENT SYSTEM AS REQUIRED. 16 PLUMBING CONTRACTOR SHALL REMOVE AND SALVAGE THE EXISTING PLUMBING FIXTURE AND FACUET TO BE REINSTALLED. 17 REINSTALL SALVAGED LAVATORY AT THIS LOCATION. INSTALL WALL HUNG LAVATORY AT ADA HEIGHT WITH OFFSET TRAP TO ALLOW FOR ADA CLEARANCE UNDERNEATH THE FIXTURE. PROVIDE PROTECTIVE SHIELDING GUARDS TO COVER HOT AND COLD WATER SUPPLIES AND TRAP AND DRAIN PIPING. 1/8" = 1'-0"1 Level Foundation Demolition Plan 1/8" = 1'-0"2 First Floor Plumbing Demolition Plan 1/8" = 1'-0"3 Level Foundation Sanitary Plan 1/8" = 1'-0"4 First Floor Plumbing Plan 5 SANITARY RISER DIAGRAM -GI CLINIC # Revision Description Date Issued 06/08/21 A or AMP AC A/C ACP ACU ADD ADJ AF AFC AFF AFG AHU AIC AL AM AMB APPROX. ARCH ATS AUTO AVG BC BKR BHP BL BLDG BR BTM C ºC CAB CB or C/B C/C CCTV CKT CL CLG COL COMM COMP CONC CONST CONT CONTR CR CT CU DB DC DEPT DF DIST DM DO DRS DWG EC EF ELEC ELEV ELV EMER ENCL EP EQUIP EWC EX EXH EXP EXT ºF FA FAAP FACP FC FCU FFC FFS FHC FIN FIXT FL FLUOR FLEX-CONN FPC FSS FTG FVR FV FVNR G or GND GALV GC GEN GFCI GFI GFP HGT HH HID HO HOA HORZ HP HPS HTR HV AMPERE ALTERNATING CURRENT AIR CONDITIONING ACCESS PANEL AIR CONDITIONING UNIT ADDITION ADJUSTABLE AMPERE FRAME ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALUMINUM AMMETER AMBIENT APPROXIMATELY ARCHITECT AUTOMATIC TRANSFER SWITCH AUTOMATIC AVERGE BARE COPPER BREAKER BRAKE HORSEPOWER BUILDING LINE BUILDING BRANCH BOTTOM CONDUIT DEGREES CELSIUS CABINET CIRCUIT BREAKER CENTER TO CENTER CLOSED CIRCUIT TELEVISION CIRCUIT CENTER LINE CEILING COLUMN COMMUNICATION COMPRESSOR CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CRITICAL CURRENT TRANSFORMER COPPER DIRECT BURIAL DIRECT CURRENT DEPARTMENT DRINKING FOUNTAIN DISTRIBUTION DEMAND METER DRAWOUT DOCTORS DRAWING ELECTRICAL CONTRACTOR EXHAUST FAN ELECTRIC ELEVATOR ELEVATION EMERGENCY ENCLOSURE ELECTRIC PNEUMATIC EQUIPMENT ELECTRIC WATER COOLER EXPLOSIONPROOF EXHAUST EXPANSION EXTERIOR DEGREES FAHRENHEIT FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FLAT CABLE FAN COIL UNIT FOOD FACILITY CONTRACTOR FOOD FACILITY SUPPLIER FIRE HOSE CABINET FINISH FIXTURE FLOOR FLUORESCENT FLEXIBLE CONNECTION FIRE PROTECTION CONTRACTOR FUSED SAFETY SWITCH FOOTING FILMVIEWER FULL VOLTAGE FULL VOLTAGE NON REVERSING GROUND GALVANIZED GENERAL CONTRACTOR GENERATOR GROUND FAULT CKT. INTERRUPTER GROUND FAULT INTERRUPTER GROUND FAULT PROTECTION HEIGHT HANDHOLE HIGH INTENSITY DISCHARGE HAND OPERATED HAND-OFF-AUTOMATIC HORIZONTAL HORSEPOWER HIGH PRESSURE SODIUM HEATER HIGH VOLTAGE HZ IC ID INCAN INCL ISG JB JT KEC KT KVA KVAR KW LAB LB LF LOC LS LT LTG LV MATV MAX MC MCB MCC MDP MECH MH MIN MISC MLO MTD MTG HT MU OD OFCI OFOI OPNG OPP OR P PB PBOX PE PF PH or Ø PV PNL PL PREFAB PRES PT PTS PW PWR RACU RAD RECEPT REF or REFR REINF RGIP RM RPM SA SC SG SHT SIG SN SPEC SQ SS SSSS STD STN STR SUSP SW SWBD SWGR TCC TELE TEMP TMH TV TYP UC U/C UH UV V VAC VB VC VEL VFD VM VOL VP VSD/VFC W/ W/O WTR WP WT XFMR Z HERTZ INTERCOMMUNICATION INSIDE DIAMETER INCANDESCENT INCLUDE ISOLATED GROUND SURGE GUARD JUNCTION BOX JOINT KITCHEN EQUIPMENT CONTRACTOR KITCHENETTE KILOVOLT AMPERE KILOVOLT AMPERE REACTIVE KILOWATT LABORATORY POUND LINEAR FEET LOCATION LIFE SAFETY LIGHT LIGHTING LOW VOLTAGE MASTER ANTENNA TELEVISION MAXIMUM MECHANICAL CONTRACTOR MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION PANEL MECHANICAL MANHOLE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOUNTING HEIGHT MEDICINE UNIT OUTSIDE DIAMETER OWNER FURNISHED-CONTRACTOR INSTALLED OWNER FURNISHED-OWNER INSTALLED OPENING OPPOSITE OPERATING ROOM POLE PUSHBUTTON PULL BOX PNEUMATIC ELECTRIC CONVERTER POWER FACTOR PHASE POST INDICATOR VALVE PANELBOARD PILOT LIGHT PREFABRICATED PRESSURE PNEUMATIC TUBE PNEUMATIC TUBE STATION PART WINDING POWER ROOM AIR CONDITIONING UNIT RADIATION RECEPTACLE REFRIGERATOR REINFORCED REMOTE GROUND INDICATING PANEL ROOM REVOLUTIONS PER MINUTE SUPPLY AIR SHORT CIRCUIT SURGE GUARD PROTECTION SHEET SIGNAL SOLID NEUTRAL SPECIFICATIONS SQUARE SAFETY SWITCH SOLID STATE SOFT START STANDARD STATION STRUCTURAL SUSPENDED SWITCH SWITCHBOARD SWITCHGEAR TEMPERATURE CONTROL CONTRACTOR TELECOMMUNICATION TEMPERATURE TOP OF MANHOLE TELEVISION TYPICAL UNDER CARPET UNDER CABINET or UNDER COUNTER UNIT HEATER UNIT VENTILATOR VOLT VACUUM VACUUM BREAKER VACUUM CLEANING VELOCITY VARIABLE FREQUENCY DRIVE VOLTMETER VOLUME VAPORPROOF VARIABLE SPEED DRIVE/CONTROLLER WITH WITHOUT WATER WEATHERPROOF WEIGHT TRANSFORMER IMPEDANCE ELECTRICAL ABBREVIATIONS M FIRE ALARM SYSTEM SYMBOL DESCRIPTION MANUAL SENDING STATION PIV POST INDICATOR VALVE SD CEILING SMOKE DETECTOR TS SPRINKLER SYSTEM TAMPER SWITCH FS SPRINKLER SYSTEM FLOW SWITCH SD WALL SMOKE DETECTOR SD WALL SMOKE DETECTOR WITH SOUNDER BASE SD CEILING SMOKE DETECTOR WITH SOUNDER BASE DD AUTOMATIC DUCT DETECTOR ("X" DENOTES AS FOLLOWS) RT REMOTE DETECTOR TEST STATION RI REMOTE DETECTOR INDICATOR STATION AR FIRE ALARM ADDRESSABLE RELAY X NONE -PHOTOELECTRIC TYPE S - SUPPLY R -RETURN DR DOOR RELEASE DU DOOR UNLOCK J FIREMANS JACK HD HEAT DETECTOR FD FLAME DETECTOR BD BEAM DETECTOR H WALL HORN ONLY H WALL HORN STROBE CEILING HORN ONLY CEILING HORN STROBE H H S WALL SPEAKER ONLY S WALL SPEAKER STROBE CEILING SPEAKER STROBES V WALL VISUAL ONLY CEILING VISUAL ONLYV FACP FIRE ALARM CONTROL PANEL FAAP FIRE ALARM ANNUNCIATOR PANEL ALL SYMBOLS AND ABBREVIATIONS MAY NOT BE USED ON THIS PROJECT3 ST -20 AMP, 125VAC, SAFETY TYPE S -20 AMP, 125VAC, SURGE GUARD PROTECTION TYPE WP - 20 AMP, 125VAC, WEATHERPROOF TYPE HM - 20 AMP, 125VAC, HORIZONTAL MOUNT TYPE IG -20 AMP, 125VAC, ISOLATED GROUND TYPE NONE -20 AMP, 125VAC ELECTRICAL RECEPTACLES DUPLEX RECEPTACLE -NORMAL POWER CIRCUIT DESCRIPTIONSYMBOL DUPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT DUPLEX GFCI RECEPTACLE -NORMAL POWER CIRCUIT DUPLEX GFCI RECEPTACLE -EMERGENCY POWER CIRCUIT QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT QUADRAPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT QUADRAPLEX GFCI RECEPTACLE -NORMAL POWER CIRCUIT QUADRAPLEX GFCI RECEPTACLE -EMERGENCY POWER CIRCUIT SIMPLEX RECEPTACLE -NORMAL POWER CIRCUIT SIMPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT SPECIAL RECEPTACLE -NORMAL POWER CIRCUIT SPECIAL RECEPTACLE -EMERGENCY POWER CIRCUIT DUPLEX RECEPTACLE -TOP SWITCHED "X" DENOTES AS FOLLOWS: CEILING DUPLEX RECEPTACLE -NORMAL POWER CIRCUIT CEILING DUPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT CEILING QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT CEILING QUADRAPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT FLOOR BOX DUPLEX RECEPTACLE -NORMAL POWER CIRCUIT FLOOR BOX DUPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT FLOOR BOX QUADRAPLEX RECEPTACLE -NORMAL POWER CIRCUIT FLOOR BOX QUADRAPLEX RECEPTACLE -EMERGENCY POWER CIRCUIT FLOOR BOX POWER AND TELECOM FLOOR BOX BLANK MULTI-OUTLET ASSEMBLY (POWER AND/OR TELECOM) ELECTRICAL SWITCHES DESCRIPTIONSYMBOL TOGGLE SWITCH - 20 AMP, 120/277VAC TOGGLE SWITCH -3 WAY 4 TOGGLE SWITCH -4 WAY K TOGGLE SWITCH - KEY OPERATED T TOGGLE SWITCH - HORSE POWER RATED MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION P TOGGLE SWITCH -PILOT LIGHT D DIMMER SWITCH -20 AMP, 120/277VAC D DIMMER SWITCH -3 WAY3 4D DIMMER SWITCH -4 WAY OC1 WALL OCCUPANCY SENSOR - 1 BUTTON CONTROL OC2 WALL OCCUPANCY SENSOR - 2 BUTTON CONTROL OC3 WALL OCCUPANCY SENSOR -DUAL RELAY FOR EXHAUST FAN CONTROL OC CEILING OCCUPANCY SENSOR VS1 WALL VACANCY SENSOR -1 BUTTON CONTROL VS2 WALL VACANCY SENSOR -2 BUTTON CONTROL LC LOW VOLTAGE LIGHTING CONTROLLER T 0 -3 HOUR TIMER SWITCH -20 AMP, 120/277VAC INFORMATION SYSTEMS DESCRIPTIONSYMBOL VOICE AND DATA ONLY OUTLET WAP -WIRELESS ACCESS POINT FLOOR BOX -VOICE AND DATA CEILING -VOICE AND DATA TELECOMMUNICATIONS EQUIPMENT RACK X R -ROUGH-IN ONLY # -QUANTITY OF JACK(S) AND CABLE(S) "X" DENOTES AS FOLLOWS: LIGHTING DESCRIPTION NO SHADING INDICATES NORMAL POWER SYMBOL 24" x 24" LIGHTING FIXTURE 12" x 48" LIGHTING FIXTURE HALF SHADED INDICATES LIFE SAFETY POWER FULL SHADED INDICATES EMERGENCY POWER 12" x 96" LIGHTING FIXTURE 6" x 96" LIGHTING FIXTURE 6" x 48" LIGHTING FIXTURE 6" x 36" LIGHTING FIXTURE 6" x 24" LIGHTING FIXTURE 8" DOWNLIGHT 6" DOWNLIGHT 4" DOWNLIGHT WALL MOUNTED LIGHT CEILING EXIT LIGHT (DUAL FACED) CEILING EXIT LIGHT (SINGLE FACE) WALL EXIT LIGHT EXIT LIGHT DIRECTIONAL ARROWS WALL EMERGENCY BATTERY LIGHT WALL EXIT WITH EMERGENCY LIGHTS CEILING EMERGENCY BATTERY LIGHT WALL EXIT WITH INTERIOR AND EXTERIOR EMERGENCY LIGHTS EXTERIOR POLE LIGHT (ONE HEAD) EXTERIOR POLE LIGHT (TWO HEADS) EXTERIOR POLE LIGHT (THREE HEADS) EXTERIOR POLE LIGHT (FOUR HEADS) EXTERIOR POLE LIGHT (TOP MOUNT) EXTERIOR BOLLARD NEUTRAL GROUND RACEWAY SYSTEM DESCRIPTION PHASE CONDUCTORS SYMBOL LIGHT/SCREENED SOLID OR DASHED LINES INDICATE EXISTING TO REMAIN HEAVY CONTINUOUS LINES INDICATE NEW WORK LINE SYMBOLS HEAVY DASHED LINES INDICATE EXISTING TO BE REMOVED J JUNCTION OR PULL BOX PUSHBUTTON OR PUSH PLATE PAD MOUNTED TRANSFORMER BRANCH PANELBOARD -SURFACE MOUNT COMBINATION MOTOR CONTROLLER / DISCONNECT DISCONNECT SWITCH - NON-FUSED MOTOR CONTROLLER DISCONNECT SWITCH - FUSED MOTOR ("X" DENOTES HORSEPOWER) GROUND CONNECTION ELECTRIC THERMOSTATT DESCRIPTION MOLDED CASE CIRCUIT BREAKER ELECTRICAL EQUIPMENT SYMBOL GROUND POINT GROUND ROD X PC PHOTO CELL SUSPENDED TRANSFORMER DISTRIBUTION PANELBOARD BRANCH PANELBOARD -RECESSED MOUNT AUTOMATIC TRANSFER SWITCHN E L TELECOM TERMINAL BOARD GROUND BAR GENERATOR TV AV TV SYSTEM OUTLET AUDIO/VISUAL CONTROLLER CLOCK SYSTEM OUTLETC M M MICROPHONE INPUT RECEPTACLE -WALL MOUNTED SPEAKER -WALL MOUNTED SPEAKER -CEILING MOUNTED VOLUME CONTROL MICROPHONE INPUT RECEPTACLE -CEILING MOUNTED S S V M D S E P CB CP L Z W R A N NC IC X MTV CCTV DR ES IC MI ML CR MD DC PB K BS DS SM SS DE PC PC P IR RF CL WL 2X NURSE ASSIST NURSE ASSIST/CODE BLUE DOOR SECURITY SYSTEM SYMBOL DESCRIPTION DOOR BUZZER SECURITY DOOR ALARM MAGNETIC LOCK CCTV MONITOR OUTLET ELECTRIC DOOR OPENER ELECTRIC DOOR STRIKE INTERCOM UNIT FLUSH MTD. MASTER INTERCOM AND DIRECTORY UNIT MOTION DETECTOR CCTV COAXIAL CABLE OUTLET AND POWER OUTLET SECURITY CARD READER SECURITY CONTROL PANEL SECURITY DOOR CONTACTS SECURITY EXIT PUSH BUTTON SECURITY KEYPAD BIOSCAN ACCESS PAD CAMERA DUTY STATION DESCRIPTION MASTER STATION STAFF STATION STAFF LOCATOR STATION CODE BLUE STATION SYMBOL ROOM READY INDICATOR REMOTE ANNUNCIATOR NURSE STATION INPUT JACK BED CONTROL CABLE/INTERCONNECT JACK NURSE CALL SYSTEM PATIENT STATION -SINGLE OUTLET EMERGENCY/BATH STATION ZONE LIGHT WALL MOUNTED DOME LIGHT CODE PINK STATION NURSE AUXILIARY JACK TELEMETRY ANTENNA LOCATION CEILING MOUNTED DOME LIGHT SECURITY DUTY STATION SECURITY STAFF STATION SECURITY MONITOR SECURITY DOOR EGRESS PULL CORD PULL CORD WITH ALARMA PATIENT STATION -SINGLE OUTLET WITH CODE / STAFF ASSIST BUTTONE TRACKING SENSOR (IR) TRACKING SENSOR (RF) DOUBLE NURSE AUXILIARY JACK NAC FIRE ALARM NOTIFICATION APPLIANCE CONTROL PANEL WAP X X RECEPTACLE ABOVE COUNTERTOP AT +2" ABOVE BACKSPLASH TO BOTTOM OF DEVICE. COORDINATE WITH CASEWORK TO BE INSTALLED. RECEPTACLE INSTALLED BELOW COUNTERTOP AT +18" A.F.F. COORDINATE WITH CASEWORK TO BE INSTALLED. X RECEPTACLE LEGEND DESCRIPTIONABBREVIATION ABBREVIATION DESCRIPTION FXX FEEDER SIZE. (REFER TO FEEDER SCHEDULE FOR ADDITIONAL INFORMATION (APPLY TO ALL ELECTRICAL SHEETS) 1. PROVIDE SUPPORT WIRES FOR ALL LIGHT FIXTURES. 2. COORDINATE INSTALLATION OF LIGHT FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN, HVAC EQUIPMENT, DUCTWORK, PIPING AND SUPPORTS. 3. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS AT THE PROJECT SITE BEFORE SUBMITTING COST PROPOSAL. 4. ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS TO FAMILIARIZE HIMSELF WITH EXTENT OF REMODELING / ALTERATION WORK. 5. ALL WORK SHALL CONFORM TO OR EXCEED THE MINIMUM REQUIREMENTS OF THE CURRENT ANSI / NFPA 70 WITH STATE AMENDMENTS, ENERGY CODE, ANSI / IEEE C2 AND ALL FEDERAL, STATE, LOCAL AND MUNICIPAL CODES AND ORDINANCES. THE ELECTRICAL SUBCONTRACTOR SHALL COMPLY WITH THE DIRECTIONS OF ALL AUTHORITIES HAVING JURISDICTION. 6. INSTALL WORK USING PROCEDURES DEFINES IN NECA STANDARDS OF INSTALLATION. ALL WORK SHALL PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. 7. REFER TO THE ARCHITECTURAL DRAWINGS FOR CEILING WORK BY THE GENERAL CONTRACTOR. COORDINATE ALL ELECTRICAL WORK. 8. THE ELECTRICAL SUBCONTRACTOR SHALL PROVIDE ALL FLOOR, WALL, AND CEILING PENETRATIONS TO COMPLETE HIS / HER WORK. PROVIDE PROPER FIRE SAFEING FOR ALL PENETRATIONS MADE. PROVIDE APPROPRIATE SEALANT (I.E. FIRESAFEING) TO MAINTAIN CONSTRUCTION INTEGRITY FOR ANY PENETRATIONS THROUGH FLOORS, STRUCTURAL CEILING, AND FIRE WALLS. 9. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER TRADES TO ENSURE EFFECTIVE AND EFFICIENT OVERALL INSTALLATION. 10. COORDINATE ALL ELECTRICAL SYSTEM DOWNTIME WITH THE OWNER AND OTHER TRADES. IT IS MANDATORY THAT THE EXISTING BUILDING REMAIN IN CONTINUOUS AND NON-INTERRUPTED OPERATION DURING THE REMODELING / ALTERING OF THE EXISTING BUILDING. THE SPECIFIC AREA(S) BEING REMODELED / ALTERED AT ANY TIME ARE OBVIOUSLY EXCLUSIVE OF THE STATEMENT. SERVICES TO EXISTING BUILDING SHALL BE KEPT ON CONTINUOUS OPERATION INCLUDING POWER, FIRE ALARM, LIGHTING, TELEPHONE, ETC. DOWNTIME OF THESE SYSTEMS SHALL BE MINIMIZED. WEEKEND AND AFTER HOURS WORK MAY BE REQUIRED TO PREVENT OR MINIMIZE INTERFERENCE WITH OWNERS OPERATION. 11. CONTRACTOR SHALL WORK CLOSELY WITH THE OWNER TO IDENTIFY ALL SYSTEMS WIRING, DEVICES, ETC. THAT MUST REMAIN OPERATIONAL DURING CONSTRUCTION. COORDINATE ALL DEMOLITION WITH THE OWNER PRIOR TO ANY DEMOLITION WORK. 12. THE LOCATION OF NEW RECEPTACLES, PHONE / DATA JACKS, AND ROOM EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. FINAL LOCATIONS WILL BE DETERMINED WITH THE ARCHITECT DURING THE CONSTRUCTION PHASE. 13. IN REMODELED / ALTERED AREA ANY FEEDERS, CONDUITS, BRANCH CIRCUITS, SIGNAL AND TELEPHONE CIRCUITS, ETC. PASSING THROUGHOUT THE REMODELED / ALTERED AREAS TO SERVE (OR BE SERVED FROM EXISTING ADJACENT, REMOTE, OR SURROUNDING THAT ARE TO REMAIN) SHALL BE RETAINED AND KEPT OPERATIONS AND SHALL BE REROUTED IN ALL CASES WHERE THEY INTERFERE WITH ANY NEW WORK OR USAGE TO BE ACCOMPLISHED IN THE REMODELED / ALTERED AREA. 14. WHERE DEVICES ARE OMITTED FROM PRESENT BRANCH CIRCUITS, THE REMAINING DEVICE SHALL BE REWIRED. IF NEEDED AND AS REQUIRED, TO REMAIN IN THEIR RESPECTIVE CIRCUITS AND IN OPERATING CONDITION. 15. ALL NEW EQUIPMENT SHALL BE SUBMITTED FOR APPROVAL PRIOR TO ORDERING. 16. PHYSICAL SIZES AND LOCATIONS OF ALL MECHANICAL EQUIPMENT SHOWN ON THESE DRAWINGS ARE APPROXIMATE. COORDINATE ELECTRICAL WORK FOR THIS EQUIPMENT WITH THE OTHER TRADES. 17. ALL BRANCH CIRCUITS SHALL UTILIZE SEPARATE INDEPENDENT NEUTRAL CONDUCTORS. DO NOT COMBINE NEUTRAL CONDUCTORS. 18. ALL FEEDER NEUTRAL / GROUNDED CONDUCTORS SHALL BE CONSIDERED CURRENT CARRYING. DERATE MULTIPLE CONDUCTORS IN A RACEWAY ACCORDINGLY WITH NEC TABLES. 19. INSTALL ALL CONDUITS, RACEWAYS, AND CABLE TRAY FOR MAXIMUM HEAD CLEARANCE IN MECHANICAL AREAS. 20. ALL DEVICES SHOWN ON THESE DRAWINGS TO BE REMOVED SHALL BE REMOVED COMPLETE INCLUDING ALL ASSOCIATED CONDUIT AND WIRING BACK TO SOURCE UNLESS OTHERWISE NOTED. ALL CIRCUIT BREAKERS OR EQUIPMENT MADE SPARE BY THE DEMOLITION SHALL BE TURNED OFF AND MARKED SPARE. IT IS THE INTENT THAT ALL EXISTING ELECTRICAL DEVICES, CONDUIT, WIRING, ETC. IN THIS SPACE THAT ARE NOT REUSED AND ARE ABANDONED SHALL BE REMOVED COMPLETE. CONTRACTOR SHALL FIELD VERIFY EXACT REQUIREMENTS. NOT ALL DEVICES ARE SHOWN ON THIS DRAWING. 21. ALL DEVICES AND LIGHT FIXTURES SHOWN TO BE REMOVED FROM EXISTING BLOCK WALLS THAT ARE NOT REUSED SHALL HAVE BLANK COVERS INSTALLED. 22. ALL DEVICES SHOWN TO BE REMOVED FROM EXISTING WALLS THAT REMAIN SHALL HAVE DEVICES AND ASSOCIATED CONDUIT REMOVED AND WALL SHALL BE PATCHED. 23. REFER TO MECHANICAL DEMOLITION PLANS FOR ALL EQUIPMENT THAT IS TO BE REMOVED. REMOVE ALL ASSOCIATED CONDUIT AND WIRING TO THESE DEVICES. 24. TELEVISION SYSTEM: REMOVE ALL TELEVISION SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER TELEVISION WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 25. TELEPHONE / DATA SYSTEM: REMOVE ALL TELEPHONE / DATA SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER TELEPHONE / DATA WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 26. CCTV SYSTEM: REMOVE ALL CCTV SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER CCTV WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 27. NURSE CALL SYSTEM: REMOVE ALL NURSE CALL SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER NURSE CALL WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 28. FIRE ALARM SYSTEM: REMOVE ALL FIRE ALARM SYSTEM DEVICES AND WIRING IN AREAS OF DEMOLITION THAT ARE INSTALLED IN WALLS OR CEILINGS. ALL OTHER FIRE ALARM WIRING, EQUIPMENT AND DEVICES SHALL REMAIN. COORDINATE REMOVAL OF THIS SYSTEM AND ITS COMPONENTS WITH THE OWNER PRIOR TO WORK. 29. ALL LIGHT FIXTURES SHOWN WITH EMERGENCY BATTERY BALLASTS SHALL HAVE UNSWITCHED "HOT" WIRE INSTALLED TO BALLAST. 30. NEW DEVICES SHOWN TO BE INSTALLED ON EXISTING DRYWALL WALLS SHALL BE INSTALLED FLUSH IN WALL WITH CONDUIT AND WIRING CONCEALED. CUT AND PATCH EXISTING WALLS AS REQUIRED. 31. NEW DEVICES SHOWN TO BE INSTALLED ON EXISTING BLOCK WALLS SHALL BE INSTALLED SURFACE MOUNTED AND IN SURFACE MOUNTED WIREMOLD PAINTED TO MATCH WALL. 32. WIRING SHALL BE INSTALLED ABOVE ACCESSIBLE CEILINGS AND IN DRYWALL WALLS WHERE POSSIBLE. 33. WIRING THAT IS TO BE INSTALLED IN AREAS WHERE THERE ARE NO CEILINGS SHALL BE INSTALLED EXPOSED. CABLING SHALL BE INSTALLED NEATLY AND AT RIGHT ANGLES TO STRUCTURE. WIRING SHALL BE INDEPENDENTLY SUPPORTED AS REQUIRED. WIRING SHALL NOT LAY OVER OTHER TRADES. 34. NEW DEVICES SHALL MATCH EXISTING DEVICES AND COVERPLATES. 35. WHERE OCCUPANCY SENSORS ARE INDICATED ON PLANS, THE ENTIRE ROOM SHALL BE COVERED. MANUFACTURER IS RESPONSIBLE FOR SENSOR LAYOUT. ADDITIONAL SENSORS REQUIRED DUE TO LACK OF COVERAGE SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. PROVIDE QUANTITY AS REQUIRED. CEILING AND WALL MOUNTED SENSORS SHALL BE DUAL TECHNOLOGY TYPE. SENSORS SHALL INCLUDE ALL POWER SUPPLIES AND RELAYS NECESSARY TO CONTROL LIGHT FIXTURES IN ROOM / AREA. SENSORS SHALL OPERATE IN "VACANCY" MODE -MANUAL ON / AUTO OFF. TYPE OC SQUARE - INDICATES A WALL MOUNTED SINGLE CIRCUIT SENSOR WITH 1 SWITCH, TYPE ROUND OC INDICATES A CEILING MOUNTED SENSOR. PROVIDE A SET OF AUXILIARY CONTACTS ON ALL WALL AND CEILING MOUNTED OCCUPANCY SENSORS FOR SENSOR STATUS FOR TEMPERATURE CONTROL. 36. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN DEMOLITION, REMOVAL, CAPPING, STORING, ABANDONING, DISCONNECTION, RELOCATING AND RECONNECTION OF EXISTING ELECTRICAL EQUIPMENT AND MATERIAL. ALL CUTTING, PATCHING, REPAIRING, REPLACEMENT AND REFINISHING, SHALL MATCH THE EXISTING CONSTRUCTION AS NEARLY AS POSSIBLE. 37. ALL WIRING (POWER, LIGHTING) NOT REUSED FOR REMODELING AREAS SHALL BE COMPLETELY REMOVED BACK TO ASSOCIATED PANELS. 38. THE OWNER SHALL HAVE THE FIRST CHOICE TO ACCEPT EXISTING DEVICES BEING REMOVED. 39. REMOVE ALL ABANDONED CONDUITS, BOXES AND WIRING WITHIN PROJECT AREA. 40. FIRE ALARM SYSTEM SHALL BE MAINTAINED DURING PROJECT. 41. CEILING MOUNTED DEVICES TO REMAIN SHALL BE SUPPORTED FROM STRUCTURE DURING CONSTRUCTION AND REINSTALLED IN NEW CEILING. 42. ARRANGEMENTS SHALL BE MADE WITH OWNER REPRESENTATIVE TO COORDINATE FIRE ALARM SYSTEM OUTAGE. 43. CONTRACTOR SHALL PROTECT EXISTING CABLES DURING ALL PHASES OF CONSTRUCTION. 44. ALL DEVICES (EXIT SIGNS, FIRE ALARM, LIGHTING, ETC) THAT ARE TAKEN OUT OF SERVICE AND NOT REUSED SHALL BE RETURNED TO THE OWNER. 45. ALL RECEPTACLES SHALL BE HOSPITAL GRADE AND SAFETY / TAMPERPROOF TYPE. SCP GENERAL NOTES 24" x 48" LIGHTING FIXTURE 12" x 36" LIGHTING FIXTURE 12" x 24" LIGHTING FIXTURE 12" x 12" LIGHTING FIXTURE www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Electrical Symbols and General Notes E00110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 26 05 00 -BASIC MATERIALS AND METHODS 1. UTILITIES: 1.1. CONTRACTOR TO COORDINATE POWER, TELEPHONE, AND TELEVISION (CABLE) SERVICE REQUIREMENTS WITH LOCAL UTILITIES PRIOR TO SUBMIITING BID PROPOSAL. 2. SHOP DRAWINGS: 2.1. SUBMIT SHOP DRAWINGS TO INCLUDE MANUFACTURER CURRENT SPECIFICATION AND LITERATURE, HIGHLIGHTED WITH OPTIONS PROVIDED AS PART OF THIS PROJECT. PROVIDED SHOP DRAWINGS FOR WIRING DEVICES, STARTERS, CIRCUIT BREAKERS, LIGHTS, LAMPS, ELECTRONIC BALLAST, PANEL BOARDS, AUTOMATIC TRANSFER SWITCH, AND FIRE ALARM. 3. ALL ELECTRICAL CONNECTORS, LUGS, BREAKERS, EQUIPMENT, ETC., SHALL BE RATED A MINIMUM OF 75 DEGREES C. 26 05 19 -LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES 1. 600 VOLTS, 98% CONDUCTIVITY, STRANDED COPPER, CLASS B, THHN/THWN INSULATION EXCEPT FOR WIRING #10 AWG AND SMALLER SHALL BE SOLID COPPER. NO ALUMINUM WIRING WILL BE ALLOWED. 26 05 33 -RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS 2. ALL INDOOR CONDUIT SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SHALL BE A MINIMUM 3/4" UNLESS OTHERWISE NOTED. UTILIZE COMPRESSION TYPE FITTINGS. USE FOR EQUIPMENT CONNECTION, FEEDERS AND BRANCH CIRCUIT WIRING. ALL CONDUIT INSTALLED ABOVE GRADE OUTSIDE OF THE BUILDING SHALL BE RIGID STEEL. ALL CONDUIT INSTALLED UNDERGROUND SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE NOTED. NO PVC CONDUIT SHALL BE USED ABOVE THE FLOOR SLAB OR EXPOSED OUTSIDE THE BUILDING. 3. 26 27 26 -WIRING DEVICES 1. RECEPTACLES: NEMA 5-20R, DUPLEX, 20 AMP, 125 VAC, GROUNDING TYPE, HOSPITAL GRADE, COLOR TO MATCH EXISTING WITH FULL METAL STRAP. HUBBELL HBL8300GY OR EQUAL. MOUNT AT 18" A.F.F. UNLESS NOTED OTHERWISE. 2. DIMMER: FLUORESCENT DIMMER SHALL BE 1500 WATTS, THIN PROFILE, SIMILAR TO LUTRON NOVA-T SERIES. 3. GFCI TYPE RECEPTACLE: NEMA 5-20R GFI, DUPLEX, 20 AMP, 125 VAC, GROUNDING TYPE, HOSPITAL GRADE, 5 MILLIAMP SENSITIVITY TRIP TYPE. HUBBELL GFR8300SGGY OR EQUAL. 4. TOGGLE SWITCHES: 20 AMP, 120 VAC RATED, QUIET TYPE, SPECIFICATION GRADE SPST, 3-WAY, OR 4-WAY TYPE AS INDICATED ON THE DRAWINGS. HUBBELL 1221-I OR EQUAL. 5. COVER PLATES: INDOOR PLATES SHALL BE NYLONE TYPE TO MATCH THE EXISTING. WEATHERPROOF PLATES SHALL BE CAST ALUMINUM GASKETED, RAINTIGHT WHILE-IN-USE TYPE. 26 05 26 -GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 1. GROUNDING AND BONDING SYSTEM SHALL MEET REQUIREMENTS OF NEC ARTICLE 250H. BOND WATER PIPE, BUILDING STRUCTURE, AND GROUND ROD WITH BARE COPPER WIRE. GROUND ROD TO BE COPPER CLAD 3/ 4"D X 10'L. CONNECT BARE COPPER CABLE TO MAIN SERVICE DISTRIBUTION BUS. 26 24 16 -PANELBOARDS 1. DISTRIBUTION: 1.1. MAIN BUS, NEUTRAL AND GROUND BAR SHALL BE 98% COPPER, NEMA-1 CABINET, GRAY PAINT, NAME PLATE, U.L. LISTED. LISTED TO USE AS SERVICE ENTRANCE. AIC RATING TO BE 42,000 AMPS UNLESS OTHERWISE INDICATED. PANEL TO BE SIMILAR TO SQUARE "D" I- LINE, G.E. SPECTRA, CUTLER HAMMER PRL4, SIEMENS S5. 26 09 23 -LIGHTING CONTROL DEVICES 1. WALL MOUNTED SINGLE-CIRCUIT OCCUPANCY SENSORS: DUAL TECHNOLOGY TYPE. WATTSTOPEER/LEGRAND PW-203-I OR EQUIVALENT AS MANUFACTURED BY HUBBELL, SENSOR SWITCH, COOPER CONTROLS, OR PHILIPS. 2. 26 22 00 -LOW-VOLTAGE DRY TYPE TRANSFORMERS 1. TRANSFORMER HOUSING SHALL BE ENCLOSED IN VENTILATED, DRIP-PROOF CODE GAUGE STEEL HOUSING, REMOVABLE ACCESS PANELS, RODENT BARRIERS ON OPENING, PHOSPHATIZED, AND FINISH WITH CORROSION INHIBITING UNDERCOAT AND ANSI GRAY FINISH. 2. CORE AND COIL ASSEMBLY SHALL BE CONSTRUCTED OF CONTINUOUS COPPER WINDING, HIGH GRADE, NON-AGING, GRAIN ORIENTED SILICON STEEL CORE, COMPLETELY ISOLATED FROM THE ENCLOSURE USING VIBRATION ABSORBING MOUNT, FLEXIBLE GROUNDING STRAP. 3. TWO 2-1/ 2% FCAN AND FOUR 2-1/ 2% FCBN TAPS. 4. INSULATION SHALL BE 600 VAC, DRY TYPE, AIR COOLED, 150° C. RISE, 220° C INSULATION CLASS. 5. NOISE LEVEL SHALL BE LESS THAN ANSI STANDARD. 6. DRY TYPE TRANSFORMER SHALL BE SIMILAR TO SQUARE "D" WATCHDOG SERIES, GE QL SERIES, CUTLER-HAMMER D33/DT3 SERIES, AND SIEMENS EQUIVALENT. 26 51 00 -LIGHTING FIXTURES AND ACCESSORIES 1. LIGHTING: 1.1. FIXTURES AND ACCESSORIES SHALL BE U.L. LISTED AND LABELED. 1.2. FIXTURES SHALL BE CODE GAUGE STEEL WITH 85% REFLECTANCE BAKED ENAMEL FINISH, 660 WATTS RATED LAMP HOLDER, BALLAST SHALL BE HIGH FREQUENCY 10% THD ELECTRONIC TYPE, LENSES SHALL BE 100% VIRGIN ACRYLIC MATERIALS KSH-12, CLEAR. 1.3. OUTDOOR FIXTURE SHALL INCLUDE WEATHERPROOF HOUSING, WET/DAMP LABEL, AND -20°F COLD TEMPERATURE BALLAST/DRIVER 1.4. LED FIXTURES: 1.5.1. FLUORESCENT BALLAST SHALL BE HIGH FREQUENCY TYPE, OPERATING LAMPS WITH LESS THAN 2% LAMP FLICKER. POWER FACTOR TO BE GREATER THAN 95% AND TOTAL HARMONIC DISTORTION LESS THAN 10%. BALLASTS TO BE NON-PCB, COMPLY WITH EMI AND RFI LIMITS SET BY THE FCC PART 18, "A" SOUND RATING, AND MEET ANSI AND U.L. STANDARDS, CLASS, TYPE 1 OUTDOOR. BALLAST SHALL CARRY MINIMUM 5 YEAR WARRANTY. BALLASTS TO BE MULTIVOLT TO OPERATE ON 120 VAC OR 277 VAC. 1.6.1. HID FIXTURES SHALL BE LISTED AND LABELED TO COMPLY WITH THERMAL PROTECTION, 600 VAC RATED LAMP HOLDER. 2. LAMPS/LIGHT SOURCE: 2.2. FLUORESCENT LAMPS SHALL BE LOW-MERCURY T8, TCLP-COMPLIANT, 3500°K WITH MINIMUM CRI OF 84 UNLESS OTHERWISE INDICATED. 2.3. COMPACT FLUORESCENT LAMPS SHALL BE LOW-MERCURY QUAD OR TRIPLE TUBE AS INDICATED, TCLP-COMPLIANT, 3500°K WITH MINIMUM CRI OF 84 UNLESS OTHERWISE INDICATED. 2.4. INTERIOR HID LAMPS SHALL BE PHOSPHOR COATED, 4000°K WITH SELF-EXTINGUISHING SAFETY ARC TUBE AND A MINIMUM CRI OF 70 AND UNLESS OTHERWISE INDICATED. MAIN BUS, NEUTRAL BUS, AND GROUND BAR SHALL BE 98% COPPER, NEMA-1 CABINET, GRAY PAINT, NAME PLATE, BOLT-ON BREAKERS, DOOR AND TRIM WITH DOOR-IN-DOOR CONSTRUCTION, U.L. LISTED. AIC RATING TO BE 22,000 AMPS UNLESS OTHERWISE INDICATED. PANEL DIRECTORY. PANEL TO BE SIMILAR TO CUTLER-HAMMER PRL-1, SQUARE "D" NQ, G.E. AQ, SIEMENS S1. 2. 2.1. BRANCH PANEL: 2. ALL PANELBOARD FEEDERS AND BRANCH CIRCUIT WIRING SHALL BE INSTALLED IN CONDUIT. 3. ALL BRANCH CIRCUITS SHALL HAVE DEDICATED NEUTRALS CONDUCTORS PER CIRCUIT. SHARED NEUTRAL CONDUCTORS WILL NOT BE ALLOWED. 2. PROVIDE SEPARATE INSULATED GREEN GROUND WIRE WITH EACH BRANCH CIRCUIT AS THE EQUIPMENT GROUNDING MEANS FOR ALL ELECTRICAL DEVICES AND EQUIPMENT. PROVIDE NAME PLATE LABEL (IDENTIFICATION) ON SERVICE EQUIPMENT, SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES AND SIMILAR EQUIPMENT TO INCLUDE ENGRAVED PLASTIC LABEL IDENTIFYING THE EQUIPMENT AND WHERE IT IS FED FROM. ALL BRANCH DEVICES IN SWITCHBOARDS SHALL HAVE AN ENGRAVED PLASTIC LABEL. ALL PANELBOARDS SHALL INCLUDE A TYPEWRITTEN DIRECTORY. PROVIDE LABEL TO IDENTIFY CIRCUIT NUMBERS AT JUNCTION BOXES AND DEVICE BOXES USING BLACK MARKER FOR NORMAL CIRCUITS AND RED MARKER FOR EMERGENCY CIRCUITS. 26 05 53 -IDENTIFICATION FOR ELECTRICAL SYSTEMS 1. 2. ALL SWITCHES AND RECEPTACLES SHALL HAVE CIRCUIT NUMBERS TYPEWRITTEN ON THE FRONT FACE OF THEIR COVERPLATES USING SELF-ADHESIVE, THERMAL PRINTED LABELS. CLEAN FACEPLATES BEFORE APPLYING LABELS. 3. WHERE MULTIPLE SWITCHES ARE GANGED TOGETHER THE SWITCHES SHALL BE IDENTIFIED AS TO WHAT EACH CONTROLS.4. ALL CONDUIT INSTALLED ABOVE GRADE OUTSIDE OF THE BUILDING SHALL BE RIGID STEEL. 26 28 13 -FUSES 1. FUSES SHALL HAVE 200,000 RMS SYMMETRICAL AMPERES INTERRUPTING CAPACITY AT 600 VAC OR LESS, CURRENT LIMITING TYPE, TIME DELAY CHARACTERISTICS, REJECTION FEATURE. CEILING MOUNTED OCCUPANCY SENSORS: DUAL TECHNOLOGY TYPE. 360 DEGREE COVERAGE. HUBBELL OMNIDT TYPE OR EQUIVALENT AS MANUFACTURED BY WATTSTOPPER, SENSOR SWITCH, COOPER CONTROLS, OR PHILIPS. 26 01 00 -GENERAL PROVISIONS 1. WORK CONSISTS OF FURNISHING LABOR, MATERIALS, EQUIPMENT, AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWN IN THE CONTRACT DOCUMENTS AND SPECIFIED IN DIVISIONS 26, 27 AND 28 GENERAL ELECTRICAL SPECIFICATIONS -APPLY TO ALL ELECTRICAL SHEETS 2. INCLUDE ALL PARTS AND LABOR, WHICH ARE INCIDENTAL AND NECESSARY, FOR A COMPLETE OPERABLE INSTALLATION EVEN THOUGH NOT SPECIFICALLY MENTIONED IN THE CONTRACT DOCUMENTS. SUCH ITEMS INCLUDE NUTS, BOLTS, ANCHORS, BRACKETS, SLEEVES, OFFSETS IN CONDUIT, FITTINGS, RELAYS, ETC. 4. OBTAIN ALL TEMPORARY AND PERMANENT PERMITS AND LICENSES REQUIRED IN CONNECTION WITH THE WORK OF DIVISIONS 26, 27 AND 28. PAY ALL FEES AND EXPENSES REQUIRED FOR SUCH PERMITS AND LICENSES. 3. ARRANGE WITH THE OWNER OR LANDLORD TO PROVIDE TEMPORARY AND PERMANENT UTILITY SERVICES AS REQUIRED AND COORDINATE THEIR INSTALLATION WITH CONSTRUCTION PROGRESS OF THIS PROJECT. PAY ALL FEES AND COSTS CHARGED BY UTILITY COMPANIES FOR UTILITY SERVICES. 5. REQUEST INSPECTIONS AS REQUIRED BY REGULATING AGENCIES AND/OR REGULATORS. PAY ALL CHARGES FOR INSPECTIONS BY REGULATING AGENCIES OF INSTALLATIONS OF PLANS AND SPECIFICATIONS 6. INCLUDE STATE AND LOCAL SALES TAXES IN THE BID. KEEP ACCURATE RECORDS OF THESE TAXES AND FURNISH SUCH RECORDS TO THE OWNER, TENANT, OR LANDLORD UPON REQUEST 7. MEET OR EXCEED ALL CURRENT APPLICABLE CODES, ORDINANCES, AND REGULATIONS FOR ALL INSTALLATIONS. PROMPTLY NOTIFY THE ENGINEER, IN WRITING, IF THE CONTRACT DOCUMENTS APPEAR TO CONFLICT WITH GOVERNING CODES AND REGULATIONS. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND COSTS FOR CORRECTING NON-COMPLYING WORK INSTALLED WITHOUT NOTIFYING THE ENGINEER 8. HIGHER QUALITY OF WORKMANSHIP AND MATERIALS INDICATED IN THE CONTRACT DOCUMENTS TAKES PRECEDENCE OVER THAT ALLOWED IN REFERENCED CODES AND STANDARDS. 9. THE TERMS DEFINED BELOW APPLY TO ALL WORK INCLUDED IN DIVISIONS 26, 27 AND 28. 9.1. THE TERM 'WORK' MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS AND INCLUDES ALL OTHER LABOR, MATERIALS, EQUIPMENT, AND SERVICES PROVIDED OR TO BE PROVIDED BY THE CONTRACTOR TO FULFILL THE CONTRACTOR'S CONTRACTUAL OBLIGATIONS. 9.2. FURNISH -TO OBTAIN IN NEW CONDITION READY FOR INSTALLATION INTO THE WORK. 9.3. INSTALL -TO STORE, SET IN PLACE, CONNECT AND PLACE INTO OPERATION IN THE THE WORK. 9.4. PROVIDE -TO FURNISH AND INSTALL. 9.5. CONNECT -TO BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENT INCLUDING NECESSARY SWITCHES, OUTLETS, BOXES, TERMINATIONS, ETC. 9.6. CONDUIT -INCLUDES IN ADDITION TO CONDUIT, ALL FITTINGS, PULL BOXES, HANGERS, AND OTHER SUPPORTS AND ACCESSORIES RELATED TO SUCH CONDUIT. 9.7. CONCEALED -HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, HUNG CEILINGS, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES, OR BURIED. 9.8. EXPOSED -NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. 4. WORKING SPACE AROUND ELECTRICAL EQUIPMENT TO BE MARKED OFF IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES, FIRE CODES, AND OTHER APPLICABLE CODES. 1. ENCASE ALL CONDUCTORS IN A CONTINUOUS RACEWAY SYSTEM. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED BY THE NATIONAL ELECTRICAL CODE (NEC). SIZE ALL RACEWAYS PER THE NEC WITH OVERSIZE CONDUITS AS INDICATED. PROVIDE A MINIMUM 3/4-INCH CONDUIT. 4. ALL CONDUIT INSTALLED UNDERGROUND SHALL BE SCHEDULE 40 PVC UNLESS OTHERWISE NOTED. PROVIDE COATED RIGID STEEL ELBOWS FOR ALL UNDERGROUND ELBOWS USED WITH PVC RACEWAY. NO PVC CONDUIT SHALL BE USED ABOVE THE FLOOR SLAB OR EXPOSED OUTSIDE THE BUILDING. 5. PROVIDE RIGID STEEL OR CONCRETE-ENCASED PVC CONDUIT FOR SERVICE ENTRANCE CONDUCTORS. 6. PROVIDE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO TRANSFORMERS, MOTORS, AND OTHER EQUIPMENT THAT VIBRATE. PROVIDE LIQUIDTIGHT CONDUIT FOR ALL CONNECTIONS IN DAMP OR WET LOCATIONS. PROVIDE GROUNDING TYPE FITTINGS AND GROUNDING CONDUCTOR INSIDE ALL FLEXIBLE CONDUITS. ADJUST CONDUIT SIZE AS REQUIRED. 7. PROVIDE EXPANSION FITTINGS WHERE RACEWAY CROSSES BUILDING EXPANSION JOINTS. 8. RUN ALL EXPOSED CONDUIT IN A NEAT, WORKMANLIKE MANNER PARALLEL TO THE BUILDING LINES, TIGHT TO THE WALL AND CEILING SURFACES, AND FIRMLY SUPPORTED WITH CONDUIT CLAMPS OR HANGERS. PROVIDE TWO-HOLE MOUNTING STRAPS, MINIMUM OF THREE FEET ON CENTER FOR ALL SURFACE CONDUIT MOUNTED ON WALLS LESS THAN SIX FEET ABOVE FINISHED FLOOR. PLACE CONDUITS AT LEAST 8 INCHES AWAY FROM ALL HOT PIPING AND SURFACES INCLUDING DOMESTIC HOT WATER LINES. 9. PROVIDE GALVANIZED CODE GAUGE STEEL JUNCTION AND PULL BOXES WITH SCREW-ON COVERS OF TYPE, SHAPE, AND SIZE REQUIRED TO SUIT EACH INSTALLATION. PROVIDE GASKETING IN DAMP AND DUSTY LOCATIONS. PROVIDE CAST BOXES IN WEATHERPROOF, VAPORTIGHT, AND EXPOLOSION-PROOF ENVIRONMENTS. 10. BOXES TO BE GLAVANIZED STEEL, MINIMUM OF 4" SQUARE WITH ONE-GANG OR TWO-GANG PLASTER RING AS REQUIRED. MINIMUM DEPTH OF 3-1/ 2" DEEP BOXES WHERE INSTALLED IN MASONRY WALLS; MINIMUM DEPTH OF 2-1 /8" ALL OTHER LOCATIONS. 11. MOUNT OUTLET BOXES IN EXPOSED MASONRY WALLS WITH THE BOTTOM OF THE BOX ON THE TOP OF THE MORTAR JOINT AND THE CENTER-LINE OF THE BOX EITHER ON THE MORTAR JOINT OR ON THE CENTER-LINE OF THE MASONRY UNIT. PLUMB AND ACCURATELY ALIGN ALL WALL OUTLETS IN ROWS. MOUNT CEILING BOXES SYMMETRICALLY WITH WALLS, BEAMS, AND/OR TILES. MOUNTING HEIGHTS INDICATED ON THE DRAWINGS ARE FROM THE CENTER OF THE OUTLET BOX TO THE FINISHED FLOOR DIRECTLY BELOW THE OUTLET UNLESS NOTED OTHERWISE. EXTERIOR HEIGHTS ARE FROM INSIDE ADJACENT DOOR, OR IF NO DOOR, FROM THE FIRST FLOOR ABOVE GRADE, UNLESS NOTED OTHERWISE. 12. COORDINATE THE LOCATIONS OF ALL OUTLETS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS BEFORE INSTALLATION. COORDINATE ALL DOOR SWINGS IN THE FIELD BEFORE LOCATING SWITCHES. 10. THE DRAWINGS AND SPECIFICATIONS CONSTITUTE THE CONTRACT DOCUMENTS. ANY ITEM NOTED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS IS INCLUDED IN THE CONTRACT DOCUMENTS. 11. ALL ELECTRICAL DETAILS AND DRAWINGS ARE DIAGRAMMATIC, UNLESS SPECIFICALLY NOTED OTHERWISE. FIELD VERIFY ALL DIMENSIONS AND NOTIFY THE ENGINEER OF ANY CONFLICTS OR DISCREPANCIES, IN WRITING, PRIOR TO INSTALLATION. 12. INITIATE, MAINTAIN, AND SUPERVISE ALL SAFETY PRECAUTIONS REQUIRED WITH THIS WORK IN ACCORDANCE WITH THE REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) AND OTHER GOVERNING AGENCIES. 13. DO NOT REMOVE OR DISTURB ANY ASBESTOS CONTAINING MATERIALS FROM THE PROJECT. IMMEDIATELY STOP WORK AND NOTIFY THE OWNER, TENANT, OR LANDLORD IF ASBESTOS CONTAINING MATERIALS ARE SUSPECTED. 14. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED, EXAMINE THE SITE OF THE PROPOSED WORK AND BECOME THOROUGHLY FAMILIAR WITH THE EXISTING CONDITIONS AND LIMITATIONS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDINGS AS TO THE AMOUNT OF WORK INVOLVED NOR BIDDERS LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHICH COULD HAVE BEEN DISCOVERED OR REASONABLY ANTICIPATED PRIOR TO BIDDING. 15. CONDUITS, PIPES, DUCTS, LIGHTS, DEVICES, SPEAKERS, ETC., SHOWN ON THE DRAWINGS AS EXISTING HAVE BEEN BASED ON EXISTING PLANS AND MAY NOT BE INSTALLED AS ORIGINALLY SHOWN. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE, LOCATION, AND CONDITION OF SUCH FACILITIES PRIOR TO SUBMITTING AS BID. 16. CONSULT THE DRAWINGS AND SPECIFICATIONS OF MECHANICAL AND OTHER TRADES FOR CORRELATING INFORMATION AND LAYOUT WORK SO THAT THE ELECTRICAL WORK WILL COORDINATE WITH OTHER TRADES. VERIFY DIMENSIONS AND CONDITIONS (I.E. FINISHED CEILING HEIGHTS, FOOTING AND FOUNDATION ELEVATIONS, BEAM DEPTHS, ETC.) WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS THAT CANNOT BE RESOLVED, IN THE FIELD, BY AFFECTED TRADES. REPLACEMENT OF WORK DUE TO LACK OF COORDINATION AND FAILURE TO VERIFY EXISTING CONDITIONS WILL BE COMPLETED AT NO COST TO THE OWNER, TENANT, OR LANDLORD. 17. INSTALL ALL CONDUITS, CABLE TRAY, BUS DUCT, EQUIPMENT, ETC., ALLOWING PROPER CODE AND MAINTENANCE CLEARANCES AND TO AVOID BLOCKING PASSAGEWAYS AND ACCESS PANELS. 18. WHERE WORK MUST BE REPLACED DUE TO THE FAILURE OF THE CONTRACTOR TO VERIFY THE CONDITIONS EXISTING ON THE PROJECT, SUCH REPLACEMENT MUST BE ACCOMPLISHED AT NO COST TO THE TENANT OR LANDLORD. THIS APPLIES TO SHOP FABRICATED WORK AS WELL AS TO WORK FABRICATED IN PLACE. 19. THROUGHOUT THE COURSE OF THE WORK, MINOR CHANGES AND ADJUSTMENTS TO THE INSTALLATION MY BE REQUESTED BY THE ENGINEER. THE CONTRACTOR SHALL MAKE ADJUSTMENTS WITHOUT ADDITIONAL COST TO THE TENANT OR LANDLORD, WHERE SUCH ADJUSTMENTS ARE NECESSARY TO THE PROPER INSTALLATION AND OPERATION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. THIS DOES NOT INCLUDED WORK ALREADY COMPLETED. 20. OBTAIN EXACT LOCATION OF CONNECTION TO EQUIPMENT FURNISHED BY OTHERS FROM THE PERSON FURNISHING THE EQUIPMENT. 21. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER ONE IS AS BINDING AS IF CALLED FOR IN BOTH. 22. PROVIDE THE BETTER QUALITY, GREATER QUANTITY, OR HIGHER COST FOR AN ITEM OR ARRANGEMENT WHERE A DISAGREEMENT EXISTS IN THE DRAWING AND SPECIFICATIONS. 23. GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS, AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR AFTER THE FINAL COMPLETION OF THE WORK. 24. DEFECTS OF ANY KIND DUE TO THE FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED GUARANTEE PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE TENANT AND ARCHITECT AND ENGINEER. INCLUDE DAMAGE TO THE FINISH OR THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS. 25. REPLACE ALL RECEPTACLES, SWITCHES, COVERPLATES, ETC., DAMAGED BY ANY CONTRACTOR DURING THE COURSE OF CONSTRUCTION. 26. MATERIALS FURNISHED FOR THE TEMPORARY LIGHTING AND POWER SYSTEM REMAIN THE CONTRACTOR'S PROPERTY. REMOVE WHEN THERE IS NO LONGER ANY NEED FOR TEMPORARY LIGHTING AND POWER. 27. COORDINATE/SCHEDULE ALL WORK WITH THE OWNER, TENANT, OR LANDLORD TO MINIMIZE ANY DISRUPTIONS. CONFINE ALL INTERRUPTIONS TO THE SMALLEST POSSIBLE AREA. PROVIDE TEMPORARY CONNECTIONS IF REQUIRED TO PROVIDE CONTINUITY OF SERVICE. 28. INSPECT ALL AREAS AFFECTED BY THE INTERRUPTIONS AND RETURN ALL AUTOMATICALLY CONTROLLED EQUIPMENT, ELECTRICALLY OPERATED EQUIPMENT TO THE SAME OPERATING CONDITION PRIOR TO THE INTERRUPTION. 29. NO FIRE ALARM SYSTEMS ARE TO REMAIN INACTIVE AT THE END OF THE WORK DAY. ASSURE THAT THE FIRE ALARM SYSTEM IS OPERATIONAL AT THE END OF EACH WORK DAY. COORDINATE WITH THE OWNER OR LANDLORD. 30. DO NOT DISTURB NORMAL USE OF THE FACILITY, EXCEPT WITH THE IMMEDIATE CONSTRUCTION AREA. KEEP WALKS, DRIVEWAYS, ENTRANCES, ETC., FREE AND CLEAR OF EQUIPMENT, MATERIALS, AND DEBRIS. 31. STORE ALL EQUIPMENT AND MATERIALS IN A PLACE AND MANNER THAT MINIMIZES CONGESTION AND IS APPROVED BY THE OWNER, TENANT, AND LANDLORD. 32. PROVIDE NEW MATERIAL AND EQUIPMENT, UNLESS NOTED OTHERWISE. PROTECT EQUIPMENT AND MATERIAL FROM DAMAGE, DIRT, AND THE WEATHER. 33. PROVIDE THE HIGHEST QUALITY WORKMANSHIP, AND PERFORM ALL WORK ONLY BY SKILLED MECHANICS. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS, AND CURRENT NECA STANDARDS. 34. THE OWNER, TENANT, AND LANDLORD RESERVES THE RIGHT TO REJECT MATERIAL, EQUIPMENT, OR WORKMANSHIP NOT IN ACCORDANCE WITH THE SPECIFICATIONS, BEFORE OR AFTER INSTALLATION. 35. PERFORM ALL CUTTING AND PATCHING NECESSARY TO WORK, UNLESS SPECIFICALLY DELEGATED TO THE GENERAL CONTRACTOR. OBTAIN SPECIAL PERMISSION FROM THE OWNER OR LANDLORD BEFORE CUTTING STRUCTURAL MEMBERS OR FINISHED MATERIAL. PERFORM ALL PATCHING IN SUCH AS MANNER AS TO LEAVE NO VISIBLE TRACE AND RETURN THE AREA AFFECTED TO THE CONDITION OF UNDISTURBED WORK. PERFORM ALL PATCHING BY WORKS EXPERIENCED, SKILLED, AND LICENSED FOR THE PARTICULARLY TYPE OF WORK INVOLVED. INFERIOR WORK WILL NOT BE ACCEPTED. 36. PATCH ALL HOLES LEFT AS A RESULT OF DEMOLITION OF ELECTRICAL EQUIPMENT AND DEVICES. 37. PREVENT THE SPREAD OF DUST, DEBRIS, AND OTHER MATERIAL INTO ADJACENT AREAS. 38. REPLACE ALL CEILING TILES DAMAGED DURING INSTALLATION OF THE WORK WITH NEW TILE MATCHING THE EXISTING. 39. REFINISH ALL ELECTRICAL EQUIPMENT DAMAGED DURING SHIPPING AND/OR INSTALLATION TO ITS ORIGINAL CONDITION. REMOVE ALL RUST, PRIME, AND PAINT PER MANUFACTURER'S RECOMMENDATIONS FOR FINISH EQUAL TO ORIGINAL. 40. PAINT ALL NEW RACEWAY SYSTEMS IN EXPOSED FINISHED AREAS. 41. AFTER TESTS HAVE BEEN MADE AND ACCEPTED, CLEAN LIGHT FIXTURES, PANELS, AND OTHER EQUIPMENT INSTALLED BY THE CONTRACTOR, LEAVING THE ENTIRE WORK AREA IN A CLEAN AND COMPLETE WORKING ORDER. 42. OPERATE EQUIPMENT AND SYSTEMS IN ALL THEIR OPERATING MODES TO VERIFY PROPER OPERATION PRIOR TO FINAL INSPECTION AND OWNER INSTRUCTIONS. NOTIFY THE ENGINEER, IN WRITING, THAT ALL SYSTEMS HAVE BEEN TESTED AND ARE FUNCTIONING AND OPERATING PROPERLY. 43. INCLUDE DOCUMENTATION OF INSTRUCTIONS IN THE OPERATION AND MAINTENANCE MANUALS. 44. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ELECTRICAL EQUIPMENT OR MATERIALS UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. KEEP ALL EQUIPMENT AND MATERIALS CLEAN UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE OWNER, TENANT, AND/OR LANDLORD. 45. ROOF PENETRATIONS: COORDINIATE WITH THE OWNER, TENANT, AND/OR LANDLORD. 46. MECHANICAL SUBSTITUTIONS: INVOICE MECHANICAL CONTRACTOR, NOT TENANT, FOR COSTS INCLUDED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED ON PLANS. 6. PROVIDE ALL SWITCH AND RECEPTACLE WIRING DEVICES FROM A SINGLE MANUFACTURER. PROVIDE ALL DIMMERS FROM A SINGLE MANUFACTURER. 2. ACCEPTABLE MANUFACTURERS: BUSSMAN, MERSEN, LITTELFUSE, OR PRE-APPROVED EQUAL. 3. ALL FUSES FOR MAIN, FEEDER, AND BRANCH CIRCUITS SHALL BE BY THE SAME MANUFACTURER IN ORDER TO RETAIN SELECTIVITY AND ELECTRICAL COORDINATION AS DESIGNED. 4. APPLY FUSE MANUFACTURER'S AMBIENT TEMPERATURE ADJUSTMENT FACTORS TO FUSE RATINGS WHERE AMBIENT TEMPERATURES TO WHICH FUSES ARE DIRECTLY EXPOSED ARE LESS THAN 40 DEGREES f OR GREATER THAN 100 DEGREES 4. 1.6.2. HID BALLAST SHALL BE PULSE-START, CONSTANT WATTAGE SECONDARY SINGLE LAMP TYPE, 90% POWER FACTOR, BUILT-IN THERMAL PROTECTION 10% VOLTAGE/WATTAGE REGULATOR, DUAL VOLTAGE, INCLUDE CORE AND COIL, CAPACITOR, IGNITER, ETC., IN A SINGLE PACKAGE. 1.5. FLUORESCENT FXITURES: 1.6. HIGH INTENSITY DISCHARGE (HID) FIXTURES: 1.4.1. LED ENGINE PACKAGE SHALL BE RATED FOR A MINIMUM OPERATIONAL LIFE OF 50,000 HOURS FOR 40 DEGREES C. AMBIENT TEMPERATURE UNLESS OTHERWISE INDICATED.. 1.4.2. RATED OPERATING TEMEPERATURE RANGE OF -30 DEGREES C TO +40 DEGREES C. 1.4.3. PHOTOMETRY TO BE COMPLIANT WITH IESNA-LEM-79 AND CONDUCTED AT 35 DEGREES C. AMBIENT TEMPERATURE. 1.4.4. DRIVER TO BE U.L. LISTED, HAVE CLASS "A" SOUND RATING, AND PROVIDE FLICKER-FREE PERFORMANCE, POWER FACTOR OF 0.90 OR GREATER, TOTAL HARMONIC DISTORTION (CURRENT AND VOLTAGE) NOT TO EXCEED 20%, AND INTEGRAL SURGE SUPPRESSION. 2.1. LED SOURCES SHALL BE 3500°K WITH MINIMUM CRI OF 80 UNLESS OTHERWISE INDICATED 2.5. EXTERIOR HID LAMPS SHALL BE CLEAR ENVELOPE, 4000°K WITH SELF-EXTINGUISHING SAFETY ARC TUBE AND A MINIMUM CRI OF 65 UNLESS OTHERWISE INDICATED. 2.6. INCANDESCENT LAMPS SHALL BE EXTENDED LIFE TYPE UNLESS OTHERWISE INDICATED. 27 05 00 -COMMON WORK RESULTS FOR COMMUNICATIONS SYSTEMS 1. PROVIDE SLEEVES FOR SYSTEM WIRING AND CABLING PENETRATIONS THROUGH WALLS, FLOORS, AND CEILINGS. USE PIPE SLEEVES UNLESS PENETRATION ARRANGEMENT REQUIRES RECTANGULAR SLEEVE OPENING. EXTEND SLEEVES INSTALLED IN FLOORS TO 2 INCHES ABOVE FINISHED FLOOR LEVEL. SEAL ANNULAR SPACE BETWEEN SLEEVE AND PATHWAY OR CABLE WITH JOINT SEALANT APPROPRIATE FOR SIZE, DEPTH, AND LOCATION OF JOINT. FIRESTOP ALL FIRE RATED ASSEMBLY PENETRATIONS. 2. GIVE RIGHT-OF-WAY TO PIPING SYSTEMS INSTALLED THAT REQUIRE SLOPE. 27 15 00 -COMMUNICATIONS HORIZONTAL CABLING 1. ALL SYSTEM BACKBOARDS, PATHWAYS, HARDWARE, CONNECTORS, JACKS, AND CABLING SHALL BE IN ACCORDANCE I.U. HEALTH TELECOM STANDARDS. 2. INSTALL ALL TELECOMMUNICATIONS SYSTEM EQUIPMENT, HARDWARE, AND CABLING IN ACCORDANCE I.U. HEALTH TELECOM STANDARDS. 27 60 00 -COMMUNICATIONS SYSTEMS ROUGH-IN REQUIREMENTS 1. SYSTEM OUTLET BOXES TOTAL DEPTH, WITH PLASTER RING, TO BE A MINIMUM OF 2 5/8" DEEP . 2. RACEWAYS TO BE EMT WITH CONDUIT BUSHING AT BOTH ENDS. MINIMUM SIZES SHALL BE AS FOLLOWS: COMMUNICATIONS HORIZONTAL CABLING: 1" TRADE SIZE.2.1 ACCESS CONTROL SYSTEMS: 3/4" TRADE SIZE.2.2 CATV AND VIDEO SURVEILLANCE SYSTEMS: 3/4" TRADE SIZE.2.3 28 05 00 -COMMON WORK RESULTS FOR ELECTRONIC SAFETY AND SECURITY SYSTEMS 1. PROVIDE SLEEVES FOR SYSTEM WIRING AND CABLING PENETRATIONS THROUGH WALLS, FLOORS, AND CEILINGS. USE PIPE SLEEVES UNLESS PENETRATION ARRANGEMENT REQUIRES RECTANGULAR SLEEVE OPENING. EXTEND SLEEVES INSTALLED IN FLOORS TO 2 INCHES ABOVE FINISHED FLOOR LEVEL. SEAL ANNULAR SPACE BETWEEN SLEEVE AND PATHWAY OR CABLE WITH JOINT SEALANT APPROPRIATE FOR SIZE, DEPTH, AND LOCATOIN OF JOINT. FIRESTOP ALL FIRE RATED ASSEMBLY PENETRATIONS. 2. GIVE RIGH-OF-WAY TO PIPING SYSTEMS INSTALLED THAT REQUIRE SLOPE. 28 31 00 -FIRE ALARM SYSTEM 1. EXTEND/MODIFY THE EXISTING FIRE ALARM SYSTEM AS INDICATED FOR THE INDICATED RENOVATION WORK. MAINTAIN AND EXTEND ALL FEATURES AND FUNCTIONS OF THE EXISTING SYSTEM FOR THE NEW WORK. INSTALLER SHALL BE AUTHORIZED TO PERFORM THE WORK BY THE EXISTING FIRE ALARM SYSTEM MANUFACTURER. 3.1. NOTIFY THE LOCAL FIRE MARSHAL PRIOR TO ANY DISRUPTION OF THE SYSTEM. 2. ALL NEW SYSTEM EQUIPMENT AND WIRING SHALL BE COMPATIBLE WITH THE EXISTING SYSTEM AND SHALL BE APPROVED FOR USE WITH THE EXISTING SYSTEM BY THE MANUFACTURER OF EXISTING SYSTEM. 3. KEEP THE EXISTING FIRE ALAM SYSTEM OPERATIONAL AT ALL TIMES DURING THE WORK, EXCEPT FOR APPROVED SHUTDOWNS REQUIRE FOR THE INDICATED WORK. 3.2. MAKE ALL SYSTEM CHANGES OR SHUTDOWNS SO AS TO PROVIDE MINIMUM INTERFERENCE TO THE OPERATION OF THE FACILITY. NOTIFY THE OWNER, TENANT, AND/OR LANDLORD NOT LESS THAN 24 HOURS IN ADVANCE OF A SHUTDOWN/CHANGEOVER, AND OBTAIN APPROVAL FROM THE OWNER, TENANT, AND/OR LANDLORD. 4. INSTALL ALL SYSTEM WIRING AND CABLING IN CONDUIT OR FIRE ALAM ARMORED CABLE. MINIMUM OF #14 THHN WIRES. 5. GIVE RIGHT-OF-WAY TO PIPING SYSTEMS INSTALLED THAT REQUIRE SLOPE. 7. COLOR: DEVICES AND COVERPLATES SHALL MATCH EXISTING COLOR FOR NORMAL AND EMERGENCY. www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Electrical Specifications E00210300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290# Revision Description Date Issued 06/08/21 M H CR +4'WH HEE VMM EEEEWAP TV WLWLWL WL WLWL WLJJ E D DD DD D D OCOC OC OC OC OC OC OC OC OC OC H HWAP42 2 2 2 VVV V VVV4 44 4 2S S S S 1 2 E.5 F G F.9 G.1 .9 NL 2 1 F G F.9 G.1 .9 2 TYP. 1 1 E.5 1 2 E.5 F G F.9 G.1 .9 X-RAY VIEWER X-RAY VIEWER 21 F G F.9 G.1 .9 3 TYP. 1 TYP. 1 TYP. 1 TYP. E.5 1 2 E E.5 F G F.9 G.1 .9 21 F G F.9 G.1 .9 L1 4 L1 4 L1 4 L1 4 L1 4 L1 4 L1 4 L1 4 L2 4 L2 4 L2 4 L2 4 L2 5 L2 4 L2 4 L2 5 L2 4 L1 4 L1 4 L1 4 L1 4 L1 4 NL NL 5 L2 4 E E.5 NL L3 L3 L3 L3 L3 L3 L3 4 L3 L3 L3 4 L3 4 L3 L3 4 4444 4 4 4 4 4 L3 WAITING 001 OFFICE 002 RECEPTION 003 MD NURSE 004 W&M 005 PATIENT RR 006 EXAM 4 011 EXAM 1 007 EXAM 2 008 EXAM 3 009 WORK ALCOVE 012 STORAGE 010 1 2 E.5 F G F.9 G.1 .9 21 F G F.9 G.1 .9 7TYP. 6 TYP. 8 TYP.29 E.5 OFFICE 002 RECEPTION 003 WAITING 001 MD NURSE 004 W&M 005 PATIENT RR 006 STORAGE 010 EXAM 4 011 WORK ALCOVE 012 EXAM 3 009 EXAM 2 008 EXAM 1 007 10 10 10 10 11 NORTH www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IKEY PLAN -NOT TO SCALE AREA OF WORK April 9, 2021 First Floor Electrical Plans E10110300 N. ILLINOIS ST.INDIANAPOLIS, IN 462901/8" = 1'-0"1 First Floor Lighting Demolition Plan 1/8" = 1'-0"2 First Floor Power and Systems Demolition Plan 1/8" = 1'-0"3 First Floor Lighting Plan 1/8" = 1'-0"4 First Floor Power and Systems Plan PLAN NOTES 1 EXISTING TO REMAIN. 2 DISCONNECT AND REMOVE ALL LIGHT FIXTURES AND ASSOCIATED DEVICES SHOWN AS DASHED. REMOVE BACK TO SOURCE OR NEAREST JUNCTION BOX TO REMAIN. 3 DISCONNECT AND REMOVE ALL ELECTRICAL DEVICES SHOWN AS DASHED, INCLUDING BUT NOT LIMITED TO RECEPTACLES, FIRE ALARM DEVICES, NURSE CALL, DATA, ETC. REMOVE BACK TO SOURCE OR NEAREST JUNCTION BOX TO REMAIN. 4 CONNECT NEW NORMAL POWER LIGHT FIXTURES IN THIS ROOM / AREA TO EXISTING 277V, 20A, 1P NORMAL POWER CIRCUIT THAT WAS MAINTAINED DURING DEMOLITION. MAINTAIN EXISTING LIGHTING CONTROL. EXTEND / MODIFY EXISTING WIRING / CONDUIT AS REQUIRED. 5 CONNECT NEW LIFE SAFETY POWER LIGHT FIXTURES IN THIS ROOM / AREA TO EXISTING 277V, 20A, 1P LIFE SAFETY POWER CIRCUIT THAT WAS MAINTAINED DURING DEMOLITION. MAINTAIN EXISTING LIGHTING CONTROL. EXTEND / MODIFY EXISTING WIRING / CONDUIT AS REQUIRED. 6 TELECOM RECEPTACLE LOCATION. PROVIDE BACK BOX AND CONDUIT AS REQUIRED. REFER TO DETAILS FOR ADDITIONAL INFORMATION. 7 CONNECT NEW NORMAL POWER RECEPTACLE TO EXISTING 120V, 20A, 1P NORMAL CIRCUIT THAT WAS MAINTAINED DURING DEMOLITION. EXTEND / MODIFY EXISTING WIRING / CONDUIT AS REQUIRED. 8 CONNECT FIRE ALARM DEVICE SHOWN RETAINED FROM LAB DEMOLITION. CONNECT FIRE ALARM DEVICE TO EXISTING FIRE ALARM SYSTEM COMPLETE. PROVIDE MODIFICATION TO EXISTING SYSTEM INCLUDING BUT NOT LIMITED TO PROGRAMMING, NAC PANELS AND POWER TO NAC PANELS. 9 PROVIDE DEDICATED CIRCUIT. 10 WHITE NOISE EMITTER. CONNECT TO HEADEND EQUIPMENT COMPLETE. 11 WHITE NOISE HEADEND EQUIPMENT. CONNECT TO RECEPTACLE IN STORAGE. # Revision Description Date Issued 06/08/21 FACE PLATE CONFIGURATION DATA ONLY (1) 1-1/4" EMT CONDUIT WITH NYLON BUSHING STUBBED TO ACCESSIBLE CEILING 4-11/16" x 4-11/16" SQUARE BOX 2-7/8" DEEP 5-8 DATA OUTLETS 4-11/16" x 4-11/16" SQUARE BOX 2-7/8" DEEP 2-GANG TILE RING 1/2" DEEP (2) 1-1/4" EMT CONDUITS WITH NYLON BUSHING STUBBED TO ACCESSIBLE CEILING 1-4 DATA OUTLETS 1/2" DEEP TILE RING M C FFRDRA ST V A A R SF F EXISTING FIRE ALARM CONTROL PANEL TYPICAL FOR EACH FLOOR 120V FIRE ALARM POWER PROVIDE SIGNAL EXPANDER/AMPLIFIER POWER SUPPLY ON EACH FLOOR FOR SIGNAL DEVICES. LOCATE EQUIPMENT IN ELECTRICAL ROOM. PROVIDE SPARE CAPACITY TO ADD (2) SIGNAL DEVICES (TYP. OF EACH SIGNAL CIRCUIT) ADDRESSABLE RELAY FOR CONTROL PROVIDE ONE AT EACH AHU SUPPLY AND RETURN FAN STARTERS, AT EACH FIRE/SMOKE DAMPER AND AT EACH DOOR HOLD RELEASE DEVICE PROVIDE SPARE CAPACITY TO ADD 20% FUTURE DEVICES ON EACH INITIATION LOOP TYPICAL FIRE/SMOKE DAMPER TYPICAL DOOR HOLD/RELEASE DEVICE TYPICAL HVAC UNIT STARTER PROVIDE CONTROL WIRING IN CONDUIT AS REQUIRED TO OTHER DEVICES SEE FLOOR PLANS NOTES: 1. ALL FIRE ALARM SYSTEM WIRING SHALL BE INSTALLED IN CONDUIT COMPLETE. 2. REFER TO FLOOR PLANS FOR DEVICE LOCATIONS AND QUANTITIES. 3. EXISTING FIRE ALARM PANEL WORK SHALL INCLUDE ALL NEW CARDS, EQUIPMENT AND PROGRAMMING NECESSARY TO SUPPORT THE NEW DEVICES AS INDICATED. 4. LABEL ALL FIRE ALARM DEVICES AS DIRECTED BY THE OWNER WITH EXTERNAL TAGS AND LABELS ON DEVICE bASES. TYPICAL SMOKE DETECTOR WITH SOUNDER BASE ELECTRICAL 1012 SUPPORT STRUCTURE NOTE: FOR STEEL STRUCTURAL SYSTEM COMBINATION BEAM CLAMP AND CONDUIT HANGER OR EQUIVALENT CADDY SCREW GUN BRACKET NOTE: FOR METAL STUD WALL CONSTRUCTION ONLY. 4" SQUARE BOX METAL STUDS CONDUIT BOX MOUNTING BRACKET REFER TO DETAIL ON THIS SHEET FOR ADDITIONAL INFORMATION. LOCATED AS SHOWN ON DRAWINGS. CAT 6A CABLE 1-1/4" CONDUIT TO CABLE TRAY. TERMINATE CONDUITS WITH BUSHING. (TYPICAL) FIRST FLOOR NOTES: 1. SUPPORTS FOR CABLE SHALL BE INDEPENDENTLY SUPPORTED. CABLE SHALL NOT LAY OVER CONDUIT, DUCTWORK, PIPING,STRUCTURAL SUPPORT MEMBERS, ETC. CABLE SHALL BE NEATLY INSTALLED AT RIGHT ANGLES TO THE BUILDING LINES. ENGINEER WILL REQUIRE CABLE TO BE REMOVED AND REINSTALLED IF IT IS NOT INSTALLED IN AN ACCEPTABLE MANNER. 2. REFER TO FLOOR PLANS FOR DEVICE LOCATIONS AND QUANTITY. 3. PROVIDE PLENUM RATED WIRE / CABLE AS REQUIRED. 4. PROVIDE ALL REQUIRED EQUIPMENT AND MODIFICATIONS REQUIRED FOR A COMPLETE SYSTEM PER NEW DEVICE QUANTITIES AND LOCATIONS. EXISTING DATA RACK NUMBER INDICATES QUANTITY OF CABLES TO BE INSTALLED 2 EXISTING CABLE TRAY TELECOMMUNICATIONS CABLE TO BE TERMINATED AT IDF BY CONTRACTOR. TELECOM EQUIPMENT PROVIDED BY OWNER AS REQUIRED. 1 WAP COMPUTER 1006 SUPPORT CONNECTED TO STRUCTURE ABOVE 12 GAUGE HANGER WIRE OR CHAIN FOR FIXTURE LAY-IN CEILING LAY-IN CEILING JUNCTION BOX W/#12 WIRE (6' MAX.) FLEXIBLE CONDUIT LAY-IN CEILING LAY-IN CEILING SEISMIC CLIP www.studio3design.net Phone: (317) 595.1000 8604 Allisonville Road, Suite 330 Indianapolis, IN 46250 A B C D E 1 2 3 4 5 6 7 A B C D E THESE DRAWINGS ARE THE PROPERTY OF STUDIO 3 DESIGN, INC. ALL RIGHTS RESERVED PROJECT NUMBER: DATE: CERTIFICATION: SHEET DESCRIPTION: SHEET NUMBER: REVISION SCHEDULE: 1 2 3 4 5 6 7 21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021 Electrical Schedules and Details E80110300 N. ILLINOIS ST.INDIANAPOLIS, IN 46290LIGHT FIXTURE SCHEDULE - SUITE 1200 FIXTURE TYPE FIXTURE NAME DESCRIPTION VOLTAGE WATTAGE LAMP LUMENS COLOR TEMPERATURE ACCEPTABLE MANUFACTURERS L1 FLAT PANEL 2' X 4' LED FLAT PANEL, WHITE HOUSING, WHITE FROSTED LENS, 0-10V DIMMING 277 V 61 W LED 6000 3500K LITHONIA EPANL, METALUX 24FP, COLUMBIA CFP, OR APPROVED EQUAL L2 FLAT PANEL 2' X 2' LED FLAT PANEL, WHITE HOUSING, WHITE FROSTED LENS, 0-10V DIMMING 277 V 41 W LED 4000 3500K LITHONIA EPANL, METALUX 24FP, COLUMBIA CFP, OR APPROVED EQUAL L3 DOWNLIGHT 8" APERTURE X 8" HIGH OPEN DOWNLIGHT, LOW IRIDESCENT SEMI SPECULAR CLEAR ALUMINUM RELFECTOR, SELF TRIM WITH WHITE FLANGE. 0-10V DIMMING DRIVER (1%-100%).277 V 28 W LED 1800 3500K LITHONIA - LDN4 ELITE LIGHTING - HH4 HALO - HC4 PRESCOLITE - LF4LED NO SCALE1FLUSH MOUNTED DATA OUTLET NO SCALE2FIRE ALARM SYSTEM SCHEMATIC NO SCALE32" AND SMALLER CONDUIT SUPPORT DETAIL NO SCALE4WALL BOX INSTALLATION DETAIL NO SCALE5TELECOM SYSTEM DETAIL NO SCALE6LAY IN LIGHT FIXTURE DETAIL # Revision Description Date Issued 06/08/21