HomeMy WebLinkAboutA002 - Accessability Guidlines8"MIN.9"MIN.
11"27" MIN.34" MAX.30" MIN.25" MAX.
NOTES:
1. HOT WATER & DRAIN PIPES UNDER THE LAVATORY SHALL BE INSULATED OR CONFIGURED TO PROTECT AGAINST
CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE LAVATORY.
2. FAUCETS SHALL BE LEVER OPERATED, PUSH TYPE, OR ELECTRONICALLY CONTROLLED MECHANISMS. SELF-CLOSING
VALVES SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS.
3. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE NO HIGHER THAN 40" A.F.F.
CLEAR FLOOR SPACE17" MIN.48" MIN.30" MIN.34" MAX.PROTECTED PIPING W/ CASWORK
OF INSULATED PIPE COVER19" MAX.8" MIN. TO REFLECTIVE SURFACE40" MAX.11" MIN. 6"29" MAX.MIN.9"MIRROR
17" MIN.
19" MAX.40" MAX.NOTE: SEE SPECIFICATIONS FOR
ADDITIONAL MOUNTING HEIGHTS.
TELEPHONE MIRROR
TO BOTTOM OFREFLECTINGSURFACEDIAPER DISPENSER OR
SANITARY NAPKIN
DISPENSER
SOAP
DISPENSER
FIRE
EXTINGUISHER
CABINET (MAX.
4" PROJECTION)48" MAX.27" MIN.*SEE GUIDELINES FOR MOUNTING
HEIGHTS AT GRAB BARS.
NOTE: MOUNT ALL NON-HANDICAP ACCESSORIES
ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.WHEELCHAIRACCESSIBLEELECTRIC
WATER COOLER
34" MAX.SURFACE33" TO CHANGINGSTANDING HGT.38" - 43"GRAB BAR
33" - 36"ELECTRIC HAND
DRYER
SANITARY
NAPKIN
DISPOSAL*
WASTE RECEPTACLE /
PAPER TOWEL DISPENSER
S T
E
15" MIN.TO OPERABLE PARTS44" - 48"TO OPERABLE PARTS48".E 46" MAX.THERMOSTAT
SWITCH
ELEC. OUTLET
ABOVE 25"
DEEP
COUNTER
BABY CHANGING
STATION
TRANSFER
SIDE
FLUSH VALVE
ON OPEN SIDE
33" - 36" 17" - 19"24" MIN. 12" MIN.
36" MIN.
16" - 18"33" - 36"MAX.
12"
MIN.
42"
54" MIN.18" MIN. 39" - 41" 39"-41"17" - 19"AREA OF
REFUGE
5' - 0" TO CENTER OF SIGNNOTE:
ALL SIGNAGE SHALL BE INSTALLED ON THE WALL
ADJACENT TO THE LATCH SIDE OF THE DOOR
EXCEPT SIGNS W/ TACTILE CHARACTERS ON
PUSH SIDE OF DOORS WITH CLOSERS.
PICTOGRAM SIGNS SHALL BE A MIN. OF 6"
HEIGHT. SEE SECTION 703 OF THE ADA.
TRANSFER
SIDE
FLUSH VALVE
ON OPEN SIDE
33" - 36"17" - 19"24" MIN. 12" MIN.
36" MIN.
16" - 18"33" - 36"MAX.
12"
MIN.
42"
54" MIN.18" MIN.39" - 41" 39"-41"17" - 19"NOTE:
CONTROLS & OPERATING MECHANISMS SHALL BE OPERABLE W/ ONE HAND & SHALL NOT REQ. TIGHT
GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL
BE NO GREATER THAN 5 LBF (22.2 N) FAUCETS LEVER-OPERATED, PUSH-TYPE & ELECTRONICALLY SHALL
COMPLY WITH 4.27.4 CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. IF SELF-CLOSING
VALVES ARE USED THE FAUCET SHALL REMAIN OPEN FOR AT LEAST 10 SECONDS.
3' - 0" 6" 2' - 10"REAR GRAB BAR
3' - 6" 1' - 0"2' - 10"SIDE GRAB BAR 1 2A VERTICAL GRAB BAR2B
GRAB BAR 2B
GRAB BAR 2A
3' - 4" 1' - 6"3' - 3"
TYP. & HC
ROLL TOILET
PAPER HOLDER
(RTPH)
3
FRONT OF
TOILET
RTPH
7" 1' - 7"2' - 6"TYP. & HC SANITARY
NAPKIN DISPOSAL
(SND)
4 2' - 6"SND
HC
TOILET SEAT COVER
DISPENSER (TSCD)
5 4' - 0" TSCD
MAX.
PROTRUSION 4"
TYP. & HC
SOAP DISPENSER
(SD)
6 3' - 6"SD
PAPER TOWEL
DISPENSER
(PTD)
7 4' - 0" PTD
MAX.
PROTRUSION 4"
T.O. DISPENSER
CONTROL60" MIN.18"
FRONT APPROACH, PULL SIDE 48" MIN.12"
MIN.*
NOTE:
* IF BOTH CLOSER AND
LATCH ARE PROVIDED YX
HINGE APPROACH, PUSH SIDE
NOTE:
X = 36" MIN. IF Y = 60";
X = 42" MIN. IF Y = 54"48" MIN.*24" MIN.
NOTE:
* 54" MIN. IF CLOSER
IS PROVIDED
42" MIN.**12"
MIN.*
NOTE:
* IF BOTH CLOSER AND
LATCH ARE PROVIDED.
** 48" MIN. IF BOTH CLOSER
AND LATCH PROVIDED 42" MIN.*24"
MIN.
22"
MIN.
NOTE:
* 48" MIN. IF CLOSER
IS PROVIDED
HINGE APPROACH, PULL SIDE
FRONT APPROACH, PUSH SIDE LATCH APPROACH, PUSH SIDE
LATCH APPROACH, PULL SIDE
1 1/2"1 1/2"
2X6 ANCHORING BACK
PLATE SECURE 2X6 TO
3-5/8" MTL. STUDS OR 2X
WD. FRAMED STUDS
SCREW
1-1/2" O.D. S.S. GRAB BAR - SEE
RESTROOM FIXTURE
ACCESSORIES SPECIFICATION FOR
MFG. & MODEL NUMBER
METAL WALL FLANGE
NOTE:
INSTALLATION MUST WITHSTAND
300 LBS. DOWNWARD PULL.
VERTICAL SECTION
PLAN VIEW
1-1/2" O.D. S.S. GRAB BAR - SEE
RESTROOM FIXTURE
ACCESSORIES SPECIFICATION
FOR MFG. & MODEL NUMBER
SCREW
METAL WALL FLANGE
2X6 ANCHORING BACK PLATE
SECURE 2X6 TO 3-5/8" MTL. STUDS
OR 2X WD. FRAMED STUDS
60" MIN.56" MIN.OTHER FIXTURES
NOT ALLOWED
WITHIN THIS AREA www.studio3design.net
Phone: (317) 595.1000
8604 Allisonville Road, Suite 330
Indianapolis, IN 46250
A
B
C
D
E
1 2 3 4 5 6 7
A
B
C
D
E
THESE DRAWINGS ARE THE PROPERTY
OF STUDIO 3 DESIGN, INC. ALL RIGHTS
RESERVED
PROJECT NUMBER:
DATE:
CERTIFICATION:
SHEET DESCRIPTION:
SHEET NUMBER:
REVISION SCHEDULE:
1 2 3 4 5 6 7
21019 IUH SPRINGMILLGI CLINIC RENOVATION: PHASE IApril 9, 2021
ACCESSIBILITY
GUIDELINES 10300 N. ILLINOIS ST.INDIANAPOLIS, IN 462901/2" = 1'-0"A002
ADA KNEE & TOE CLEARANCE16A
1/2" = 1'-0"A002
ADA LAVATORY11E
12" = 1'-0"A002
ADA MOUNTING HEIGHTS4D
1/2" = 1'-0"A002
ADA REAR WALL GRAB BARS @
TOILET12D
1/2" = 1'-0" A002
ADA SIDE WALL GRAB BARS @
TOILET1 1D
3/4" = 1'-0"A002
ADA SIGNAGE16C1/2" = 1'-0"A002
ADA TOILET FIXTURES11C
1/2" = 1'-0" A002
ADA WASHROOM ACCESSORIES13E
12" = 1'-0"A002
ADA APPROACH LEGEND4C
1 1/2" = 1'-0" A002
ADA GRAB BAR - PLAN/SECTION1 4A
1/4" = 1'-0" A002
TOILET FIXTURE CLEARANCE 2A
# Revision Description
Date
Issued
06/08/21