Loading...
HomeMy WebLinkAboutG001 SHEET INDEXEARTH NOTE:PATTERNS SHOWN REPRESENT CUT MATERIALS IN PLAN OR SECTION, UNLESS NOTED OTHERWISE.GRANULAR FILL CONCRETE, CAST-IN-PLACE CONCRETE, PRECAST/CAST STONE CONCRETE MASONRY UNIT BRICK MASONRY STONE: LIMESTONE, GRANITE, MARBLE OR AS NOTED METAL: TYPE AS NOTED METAL: ROLLED SHAPES WOOD FRAMING / BLOCKING: CONTINOUS WOOD SHIM WOOD/FINISHED, SHOWN CUT AND ELEVATION PLYWOOD PARTICLEBOARD EIFS SPRAYED FIREPROOFING SHOWN ON ROLLED SHAPE BATT INSULATION: THERMAL OR ACOUSTICAL, UNO RIGID INSULATION: THERMAL, ACOUSTICAL, OR SAFING SHEATHING: GYPSUM, OR AS NOTED GYPSUM WALL BOARD TILE: CERAMIC, QUARRY, UNO RESINOUS FLOORING: TERRAZO, TROWEL-ON, UNO ACOUSTICAL CEILING TILE GRATING (PLAN) INSULATED GLASS: (SMALL SCALE) GRATING (SECTION) MEMBRANE: WATERPROOF, ROOF, DAMPPROOFING AIR BARRIER SYSTEM INSULATED GLASS: (DETAIL) TERRA COTTA, STRUCTURAL CLAY TILE CARPET, CARPET TILE (DETAIL) SAND, GROUT AS NOTED GLASS FIBER REINFORCED CONCRETE SIDING OR TRIM WOOD/ENGINEERED: GLUE LAMINATED PLASTER ON METAL LATH WOOD FLOOR, WOOD SHINGLES, OR SIDING ENLARGED DRAWING REFERENCE ELEVATION DATUM REFERENCE NORTH ARROW DRAWING NUMBER SHEET NUMBER BUILDING SECTION CUT REFERENCE SF27 101 A101 1 SIM 1 1 W3 N 1 KEYED NOTE REVISION REFERENCE STOREFRONT/CURTAINWALL/WINDOW TAG DOOR TAG ROOM NAME AND NUMBER COLUMN GRID NEW A DRAWING NUMBER SHEET NUMBER WALL SECTION CUT REFERENCE DRAWING NUMBER SHEET NUMBER EXTERIOR ELEVATION REFERENCE WALL TYPE REFERENCE (REFERENCE INTERIOR PARTITION LEGEND) COLUMN GRID EXISTING 1 EQUIPMENT TAG X XX X XX 1 Ref XX Room 101 A. SEE SHEET G001 FOR GRAPHIC SYMBOL LEGEND. B. SEE SHEET A000 FOR GENERAL PARTITION NOTES. C. SEE SHEET A701 FOR GENERAL FINISH NOTES D. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION. E. ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING, FINISHED FACE OF EXISTING WALL SURFACE, OR FACE OF CONCRETE / MASONRY UNITS UNLESS NOTED OTHERWISE. F. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR SHALL FURNISH ALL NECESSARY PERMITS. G. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS (DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.) INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THEIR WORK. CONTRACTORS SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS WASTE LAWS, ETC. H. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING COMPONENT LOCATION. BRING ANY DISCREPANCIES TO THE ARCHITECT'S ATTENTION IN WRITING IMMEDIATELY. I. BUILDING FIRST FLOOR IS REFERENCE ELEVATION 100'-0". REFERENCE CIVIL DRAWINGS FOR U.S.G.S. ELEVATION. J. ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE AND MANNER ACCEPTABLE TO THE ARCHITECT AND OWNER. K. CAULK INTERSECTION BETWEEN DIFFERENT MATERIALS. L. CAULK TOILET FIXTURES AND COUNTERTOP SPLASHES TO FINISH SURFACE IN ACCORDANCE WITH SEALANT SCHEDULE IN SPECIFICATIONS. M. EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO BIDDING OR BEGINNING OF WORK. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IN WRITING IMMEDIATELY. N. COVER ALL RETURN AIR AND EXHAUST GRILLES WITH FILTER MEDIA FOR DURATION OF JOB AND CHANGE REGULARLY. O. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPE INDICATED ON THE CONSTRUCTION DOCUMENTS IS INTENDED TO DEPICT GENERAL DESIGN INTENT ONLY. ACTUAL WORK IS TO BE DESIGNED, PERMITTED AND EXECUTED BY A QUALIFIED DESIGN-BUILD CONTRACTOR UNDER THE SUPERVISION OF THE GENERAL CONTRACTOR. THE RESPONSIBLE CONTRACTOR SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS WASTE LAWS, ETC. Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE:5/21/2021 8:30:51 AMG001 SHEET INDEX 2021.00173 05/20/2021 CONSTRUCTION DOCUMENTS ARTISTIC COMPOSITE PALLETS -PHASE 2 4518 WEST 99TH STREET CARMEL, IN 46032 ORIG ORIGINAL P PERM PERMANENT PH PHASE PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTIC PNL PANEL PREFAB PREFABRICATED PREFIN PREFINISHED PRELIM PRELIMINARY PREP PREPARATION PROJ PROJECT PT PRESERVATIVE TREATED PTD PAINTED PTN PARTITION Q QT QUARRY TILE R R RADIUS RD ROOF DRAIN REC RECESSED RECPT RECEPTACLE REF REFER(ENCE) REINF REINFORCE(D)(ING)(M ENT) REQD REQUIRED RESIL RESILIENT RM ROOM RO ROUGH OPENING RTU ROOF TOP UNOT S SAN SANITARY SCW SOLID CORE WOOD SF SQUARE FOOT SPKLR SPRINKLER SS STAINLESS STEEL STD STANDARD STL STEEL STOR or ST STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SYM SYMBOL SYS SYSTEM T T&G TONGUE AND GROOVE T/ TOP OF TEL TELEPHONE TEMP TEMPORARY THRES THRESHOLD TOT TOTAL TYP TYPICAL U UNIF UNIFORM UNO UNLESS NOTED OTHERWISE UR URINAL V VB VINYL BASE VCT VINYL COMPOSITION TILE VERT VERTICAL VIN VINYL VT VINYL TILE VWC VINYL WALL COVERING W W/W WALL TO WALL WC WATER CLOSET WD WOOD WDW WINDOW WH WALL HUNG WT WEIGHT G GALV GALVANIZED GLZ GLAZING GUT GUTTER GYP BD/GWB GYPSUM BOARD H HC HANDICAP(PED) HCW HOLLOW CORE WOOD HDWE/HDW HARDWARE HM HOLLOW METAL HMD HOLLOW METAL DOOR HORIZ HORIZONTAL HT HEIGHT HVAC HEATING, VENTILATION, AIR CONDITIONING I ICF INSULATED CONCRETE FORM ID INSIDE DIAMETER IF INSIDE FACE INCAND INCANDESCENT INDIC INDICATE INSTL INSTALL(ATION) INSUL INSULATION INT INTERIOR J JST JOIST JT JOINT L LAV LAVATORY LD BRG LOAD BEARING LF LINEAR FOOT LTG LIGHTING LTWT LIGHTWEIGHT LVR LOUVER M MAS MASONRY MATL MATERIAL MAX MAXIMUM MECH MECHANICAL MED MEDICINE (MEDICAL) MET METAL MFG MANUFACTURER (ING) MIN MINIMUM MISC MISCELLANEOUS MLWK MILLWORK MO MASONRY OPENING MTD MOUNTED MTG MOUNTING MULL MULLION MULT MULTIPLE N N/A NOT APPLICABLE NIC NOT IN CONTRACT NOM NOMINAL NTS NOT TO SCALE O O/O OUT TO OUT OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFCI OWNER FURNISHED - CONTRACTOR INSTALLED OH OVERHEAD OPNG OPENING OPP OPPOSITE OPT OPTIONAL ORD OVERFLOW ROOF DRAIN A A/E ARCHITECT/ENGINEER ACOUS ACOUSTICAL ACT ACOUSTICAL CEILING TILE ADA AMERICAN'S WITH DISABILITIES ACT ADD ADDENDUM ADJ ADJACENT AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED ARCH ARCHITECT (URAL) B BLDG BUILDING BLK BLOCK BLKG BLOCKING BM BEAM BOT BOTTOM BRG BEARING C C/C CENTER TO CENTER CAB CABINET CB CORNER BEAD CER CERAMIC CF CUBIC FOOT CFCI CONTRACTOR FURNISHED / CONTRACTOR INSTALLED CHAN CHANNEL CJ CONTROL JOINT CL CENTER LINE CLG CEILING CMU CONCRETE MASONRY UNIT CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS CP/CPT CARPET D DEMO DEMOLITION (ISH) DF DRINKING FOUNTAIN DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DO DOOR OPENING DS DOWNSPOUT DWG DRAWING E EJ EXPANSION JOINT ELEC ELECTRICAL (ELEVATOR) ELEV ELEVATION ENCL ENCLOSURE ENGR ENGINEER EQUIP EQUIPMENT EWC ELECTRICAL WATER COOLER EXST EXISTING F F/F FACE TO FACE FDN FOUNDATION FE FIRE EXTINGUISHER FHC FIRE HOSE CABINET FIN FINISH FIN FL FINISHED FLOOR FLR (FLRG) FLOOR(ING) FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RATING FT FIRE TREATED FTG FOOTING FURN FURNITURE FURR FURRING ABBREVIATIONS SHEET INDEX SHEET NUMBER SHEET NAME GENERAL G000 COVER SHEET G001 SHEET INDEX G101 FIRST FLOOR LIFE SAFETY PLAN G102 SECOND FLOOR LIFE SAFETY PLAN STRUCTURAL S001 ABBREVIATIONS AND SYMBOLS S002 GENERAL NOTES S003 GENERAL NOTES S004 LOAD MAPS S101 DEMOLITION AND FOUNDATION PLANS S102 MEZZANINE AND ROOF FRAMING PLANS S301 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS S302 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS S401 CMU SCHEDULES, SECTIONS AND DETAILS S501 STEEL SCHEDULES, SECTIONS, AND DETAILS S502 STEEL SCHEDULES, SECTIONS, AND DETAILS S503 STEEL COLUMN SCHEDULE AND BASE PLATE DETAILS S504 BRACED FRAME ELEVATIONS AND DETAILS ARCHITECTURAL DEMOLITION D101 FIRST FLOOR DEMOLITION PLAN D102 SECOND FLOOR DEMOLITION PLAN ARCHITECTURAL A000 WALL TYPES A101 FIRST FLOOR ARCHITECTURAL PLAN A102 SECOND FLOOR ARCHITECTURAL PLAN A121 FIRST FLOOR REFLECTED CEILING PLAN A122 SECOND FLOOR REFLECTED CEILING PLAN A401 ENLARGED PLANS AND ELEVATIONS A402 CASEWORK SECTIONS A601 DOOR SCHEDULES A701 FIRST FLOOR FINISH PLAN A702 SECOND FLOOR FINISH PLAN A721 ROOM FINISH SCHEDULE AND FINISH DETAILS MECHANICAL M100 HVAC PLANS PLUMBING P1 PLUMBING RISER DIAGRAMS P2 PLUMBING RISER DIAGRAMS ELECTRICAL E-000 ELECTRICAL SYMBOLS & LEGEND E-101 FIRST FLOOR POWER AND SYSTEMS E-102 SECOND FLOOR POWER AND SYSTEMS E-121 FIRST FLOOR LIGHTING E-122 SECOND FLOOR LIGHTING E-500 PANEL SCHEDULES MATERIALS LEGEND GRAPHIC LEGEND GENERAL NOTES REVISION SCHEDULE NO. DESCRIPTION DATE 06/08/21