HomeMy WebLinkAboutG001 SHEET INDEXEARTH
NOTE:PATTERNS SHOWN REPRESENT CUT
MATERIALS IN PLAN OR SECTION, UNLESS NOTED
OTHERWISE.GRANULAR FILL
CONCRETE, CAST-IN-PLACE
CONCRETE, PRECAST/CAST
STONE
CONCRETE MASONRY UNIT
BRICK MASONRY
STONE: LIMESTONE, GRANITE,
MARBLE OR AS NOTED
METAL: TYPE AS NOTED
METAL: ROLLED SHAPES
WOOD FRAMING / BLOCKING:
CONTINOUS
WOOD SHIM
WOOD/FINISHED,
SHOWN CUT AND ELEVATION
PLYWOOD
PARTICLEBOARD
EIFS
SPRAYED FIREPROOFING
SHOWN ON ROLLED SHAPE
BATT INSULATION: THERMAL OR
ACOUSTICAL, UNO
RIGID INSULATION: THERMAL,
ACOUSTICAL, OR SAFING
SHEATHING: GYPSUM, OR AS
NOTED
GYPSUM WALL BOARD
TILE: CERAMIC, QUARRY, UNO
RESINOUS FLOORING: TERRAZO,
TROWEL-ON, UNO
ACOUSTICAL CEILING TILE
GRATING (PLAN)
INSULATED GLASS:
(SMALL SCALE)
GRATING (SECTION)
MEMBRANE: WATERPROOF,
ROOF, DAMPPROOFING
AIR BARRIER SYSTEM
INSULATED GLASS:
(DETAIL)
TERRA COTTA, STRUCTURAL CLAY
TILE
CARPET, CARPET TILE (DETAIL)
SAND, GROUT
AS NOTED
GLASS FIBER REINFORCED
CONCRETE SIDING OR TRIM
WOOD/ENGINEERED: GLUE
LAMINATED
PLASTER ON METAL LATH
WOOD FLOOR, WOOD SHINGLES,
OR SIDING
ENLARGED DRAWING REFERENCE
ELEVATION DATUM REFERENCE
NORTH ARROW
DRAWING NUMBER
SHEET NUMBER
BUILDING SECTION CUT REFERENCE
SF27
101
A101
1
SIM
1
1
W3
N
1
KEYED NOTE
REVISION REFERENCE
STOREFRONT/CURTAINWALL/WINDOW TAG
DOOR TAG
ROOM NAME AND NUMBER
COLUMN GRID NEW
A
DRAWING NUMBER
SHEET NUMBER
WALL SECTION CUT REFERENCE
DRAWING NUMBER
SHEET NUMBER
EXTERIOR ELEVATION REFERENCE
WALL TYPE REFERENCE (REFERENCE
INTERIOR PARTITION LEGEND)
COLUMN GRID EXISTING
1 EQUIPMENT TAG
X
XX
X
XX
1 Ref
XX
Room
101
A. SEE SHEET G001 FOR GRAPHIC SYMBOL LEGEND.
B. SEE SHEET A000 FOR GENERAL PARTITION NOTES.
C. SEE SHEET A701 FOR GENERAL FINISH NOTES
D. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.
E. ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUD FRAMING, FINISHED FACE OF
EXISTING WALL SURFACE, OR FACE OF CONCRETE / MASONRY UNITS UNLESS NOTED
OTHERWISE.
F. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE
RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND
SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS,
SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR SHALL
FURNISH ALL NECESSARY PERMITS.
G. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF
THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS
(DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.) INDICATE THE GENERAL SCOPE OF THE
PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE
BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL,
MECHANICAL, AND ELECTRICAL SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT
INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED
FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE
CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS,
THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER
EXECUTION AND COMPLETION OF THEIR WORK. CONTRACTORS SHALL FOLLOW AND
OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND
HAZARDOUS WASTE LAWS, ETC.
H. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN EACH BUILDING COMPONENT
LOCATION. BRING ANY DISCREPANCIES TO THE ARCHITECT'S ATTENTION IN WRITING
IMMEDIATELY.
I. BUILDING FIRST FLOOR IS REFERENCE ELEVATION 100'-0". REFERENCE CIVIL DRAWINGS
FOR U.S.G.S. ELEVATION.
J. ALL WORK SHALL BE PERFORMED IN A SKILLED WORKMANSHIP TYPE AND MANNER
ACCEPTABLE TO THE ARCHITECT AND OWNER.
K. CAULK INTERSECTION BETWEEN DIFFERENT MATERIALS.
L. CAULK TOILET FIXTURES AND COUNTERTOP SPLASHES TO FINISH SURFACE IN
ACCORDANCE WITH SEALANT SCHEDULE IN SPECIFICATIONS.
M. EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO BIDDING OR BEGINNING OF
WORK. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ARCHITECT'S
ATTENTION IN WRITING IMMEDIATELY.
N. COVER ALL RETURN AIR AND EXHAUST GRILLES WITH FILTER MEDIA FOR DURATION OF
JOB AND CHANGE REGULARLY.
O. THE MECHANICAL, ELECTRICAL AND PLUMBING SCOPE INDICATED ON THE
CONSTRUCTION DOCUMENTS IS INTENDED TO DEPICT GENERAL DESIGN INTENT ONLY.
ACTUAL WORK IS TO BE DESIGNED, PERMITTED AND EXECUTED BY A QUALIFIED
DESIGN-BUILD CONTRACTOR UNDER THE SUPERVISION OF THE GENERAL
CONTRACTOR. THE RESPONSIBLE CONTRACTOR SHALL FOLLOW AND OBEY ALL
FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY REGULATIONS AND HAZARDOUS
WASTE LAWS, ETC.
Project Number
CERTIFIED BY
ISSUANCE INDEX
DATE:
PROJECT PHASE:5/21/2021 8:30:51 AMG001
SHEET INDEX
2021.00173
05/20/2021
CONSTRUCTION DOCUMENTS
ARTISTIC COMPOSITE
PALLETS -PHASE 2
4518 WEST 99TH
STREET CARMEL, IN
46032
ORIG ORIGINAL
P
PERM PERMANENT
PH PHASE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTIC
PNL PANEL
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARATION
PROJ PROJECT
PT PRESERVATIVE
TREATED
PTD PAINTED
PTN PARTITION
Q
QT QUARRY TILE
R
R RADIUS
RD ROOF DRAIN
REC RECESSED
RECPT RECEPTACLE
REF REFER(ENCE)
REINF REINFORCE(D)(ING)(M
ENT)
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNOT
S
SAN SANITARY
SCW SOLID CORE WOOD
SF SQUARE FOOT
SPKLR SPRINKLER
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR or ST STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMBOL
SYS SYSTEM
T
T&G TONGUE AND
GROOVE
T/ TOP OF
TEL TELEPHONE
TEMP TEMPORARY
THRES THRESHOLD
TOT TOTAL
TYP TYPICAL
U
UNIF UNIFORM
UNO UNLESS NOTED
OTHERWISE
UR URINAL
V
VB VINYL BASE
VCT VINYL COMPOSITION
TILE
VERT VERTICAL
VIN VINYL
VT VINYL TILE
VWC VINYL WALL
COVERING
W
W/W WALL TO WALL
WC WATER CLOSET
WD WOOD
WDW WINDOW
WH WALL HUNG
WT WEIGHT
G
GALV GALVANIZED
GLZ GLAZING
GUT GUTTER
GYP BD/GWB GYPSUM BOARD
H
HC HANDICAP(PED)
HCW HOLLOW CORE WOOD
HDWE/HDW HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING,
VENTILATION, AIR
CONDITIONING
I
ICF INSULATED
CONCRETE FORM
ID INSIDE DIAMETER
IF INSIDE FACE
INCAND INCANDESCENT
INDIC INDICATE
INSTL INSTALL(ATION)
INSUL INSULATION
INT INTERIOR
J
JST JOIST
JT JOINT
L
LAV LAVATORY
LD BRG LOAD BEARING
LF LINEAR FOOT
LTG LIGHTING
LTWT LIGHTWEIGHT
LVR LOUVER
M
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDICINE (MEDICAL)
MET METAL
MFG MANUFACTURER (ING)
MIN MINIMUM
MISC MISCELLANEOUS
MLWK MILLWORK
MO MASONRY OPENING
MTD MOUNTED
MTG MOUNTING
MULL MULLION
MULT MULTIPLE
N
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O
O/O OUT TO OUT
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFCI OWNER FURNISHED -
CONTRACTOR
INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPT OPTIONAL
ORD OVERFLOW ROOF
DRAIN
A
A/E ARCHITECT/ENGINEER
ACOUS ACOUSTICAL
ACT ACOUSTICAL CEILING
TILE
ADA AMERICAN'S WITH
DISABILITIES ACT
ADD ADDENDUM
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
ARCH ARCHITECT (URAL)
B
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
C
C/C CENTER TO CENTER
CAB CABINET
CB CORNER BEAD
CER CERAMIC
CF CUBIC FOOT
CFCI CONTRACTOR
FURNISHED /
CONTRACTOR
INSTALLED
CHAN CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CMU CONCRETE MASONRY
UNIT
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUOUS
CP/CPT CARPET
D
DEMO DEMOLITION (ISH)
DF DRINKING FOUNTAIN
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DO DOOR OPENING
DS DOWNSPOUT
DWG DRAWING
E
EJ EXPANSION JOINT
ELEC ELECTRICAL
(ELEVATOR)
ELEV ELEVATION
ENCL ENCLOSURE
ENGR ENGINEER
EQUIP EQUIPMENT
EWC ELECTRICAL WATER
COOLER
EXST EXISTING
F
F/F FACE TO FACE
FDN FOUNDATION
FE FIRE EXTINGUISHER
FHC FIRE HOSE CABINET
FIN FINISH
FIN FL FINISHED FLOOR
FLR (FLRG) FLOOR(ING)
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RATING
FT FIRE TREATED
FTG FOOTING
FURN FURNITURE
FURR FURRING
ABBREVIATIONS SHEET INDEX
SHEET NUMBER SHEET NAME
GENERAL
G000 COVER SHEET
G001 SHEET INDEX
G101 FIRST FLOOR LIFE SAFETY PLAN
G102 SECOND FLOOR LIFE SAFETY PLAN
STRUCTURAL
S001 ABBREVIATIONS AND SYMBOLS
S002 GENERAL NOTES
S003 GENERAL NOTES
S004 LOAD MAPS
S101 DEMOLITION AND FOUNDATION PLANS
S102 MEZZANINE AND ROOF FRAMING PLANS
S301 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS
S302 FOUNDATION SCHEDULES, SECTIONS, AND DETAILS
S401 CMU SCHEDULES, SECTIONS AND DETAILS
S501 STEEL SCHEDULES, SECTIONS, AND DETAILS
S502 STEEL SCHEDULES, SECTIONS, AND DETAILS
S503 STEEL COLUMN SCHEDULE AND BASE PLATE DETAILS
S504 BRACED FRAME ELEVATIONS AND DETAILS
ARCHITECTURAL DEMOLITION
D101 FIRST FLOOR DEMOLITION PLAN
D102 SECOND FLOOR DEMOLITION PLAN
ARCHITECTURAL
A000 WALL TYPES
A101 FIRST FLOOR ARCHITECTURAL PLAN
A102 SECOND FLOOR ARCHITECTURAL PLAN
A121 FIRST FLOOR REFLECTED CEILING PLAN
A122 SECOND FLOOR REFLECTED CEILING PLAN
A401 ENLARGED PLANS AND ELEVATIONS
A402 CASEWORK SECTIONS
A601 DOOR SCHEDULES
A701 FIRST FLOOR FINISH PLAN
A702 SECOND FLOOR FINISH PLAN
A721 ROOM FINISH SCHEDULE AND FINISH DETAILS
MECHANICAL
M100 HVAC PLANS
PLUMBING
P1 PLUMBING RISER DIAGRAMS
P2 PLUMBING RISER DIAGRAMS
ELECTRICAL
E-000 ELECTRICAL SYMBOLS & LEGEND
E-101 FIRST FLOOR POWER AND SYSTEMS
E-102 SECOND FLOOR POWER AND SYSTEMS
E-121 FIRST FLOOR LIGHTING
E-122 SECOND FLOOR LIGHTING
E-500 PANEL SCHEDULES
MATERIALS LEGEND GRAPHIC LEGEND
GENERAL NOTES
REVISION SCHEDULE
NO. DESCRIPTION DATE
06/08/21